Negative sequence current transmitterDetailed product description:Column tabs
N3-AND AC negative sequence current transmitter is an instrument that can isolate the negative sequence current signal in the measured three-phase circuit and convert it into a DC voltage or current output proportional to the input negative sequence quantity. It is widely used in three-phase circuits of power systems and is equipped with corresponding indicator instruments or devices to measure negative sequence current. It can operate continuously for a long time.

detailed description:
Reference standards and rules: GB/T 13850-1998
Accuracy level: 0.5 or 0.2
Stability: Complies with GB/T 13850-1998
Input: Input line current: 0-5A or user specified specifications
Input negative sequence current: 0-5A or user specified specifications
Input signal frequency: 50Hz or user specified specifications
Output: Three isolation of input, output, and power supply.
DC4~20mA; RL≤500Ω
Working temperature: 0~+50 ℃
Relative humidity: ≤ 95% without condensation
Response time: < 400ms
Peak output ripple:<0.5%
Working frequency: nominal frequency ± 10%
Output load: constant current output: maximum 10V voltage drop; Constant voltage output: rated 2mA, maximum 5mA output
Output load impact:<0.1% (within the rated load range)
Input load: Current circuit < 0.5VA Voltage circuit < 0.5VA
Auxiliary power supply: rated voltage 80-120% rated frequency 90-110%
Input overload range: current 2 times continuously for 20 times for 1 second; Voltage maximum 2 times continuous
Insulation strength: in accordance with GB/T 13850-1998
Impact test: ANSI C37.90a/1973, DIN IEC 255-4 (5kV 1.2/50 μ s pulse voltage)
Correction amplitude: minimum ± 3% at full scale, minimum ± 1% at zero point
Magnetic field influence: 0.4KA/m magnetic field strength change<0.05%
Storage conditions: Temperature -40~+70 ℃, relative humidity 20-99%, no condensation
Dimensions: 119 (L) × 109 (W) × 75 (H) mm
Installation method: 35 mm DIN rail clamp or fixed with 2 × M4 × 15 screws