Product Features
The principle of guided waves is almost not limited by any process conditions. For example, it is not sensitive to dust and steam conditions, and even environments with large amounts of steam do not affect its measurement accuracy
The probe can be truncated, so customers can adjust the length on site according to their range needs, making it very flexible to use.
The advanced design principles determine that its measurement accuracy is not affected by medium fluctuations, density, or changes in dielectric constant (as long as it reaches the specified dielectric constant)
Suitable for working conditions where material hanging may occur, even if a large amount of medium is adsorbed on the probe and container wall, it will not have any impact on the measurement results
Verification can be completed without filling the tank
Two wire and four wire connection methods are available for selection
Can be used for liquid level, material level, and interface measurement
Can provide a bypass design or directly cooperate with glass or magnetic flip column level gauges to form a comprehensive measurement solution
Technical parameters
Process interface:
-20 ℃~+250 ℃ thread installation (thread downward): 1 "or 1.5" (single rod probe, soft cable probe)
(Working temperature) 3/4 "or 1" or 1.5 "coaxial probe
-200 ℃~+400 ℃ thread installation (thread downward): 1.5 inches
Working temperature:
Material:
-Process interface from 20 ℃ to+250 ℃: 316L, Hastelloy C22 (2.4602) and PEEK GF 30
(Working temperature) Coaxial probe, single rod probe: 316L and PEEK GF30 (flexible cable probe)
Coaxial probe (Ø 21.3mm): 316L, Hastelloy C22 (2.4602)
Single rod probe (Ø 6mm): 316L, Hastelloy C22 (2.4602)
Soft cable probe (Ø 4mm): 1.4401 (316)
-Process interface from 200 ℃ to+400 ℃: 316L, Hastelloy C22 (2.4602) and Ceramic (AL2O3)
(Working temperature) Coaxial probe (Ø 43mm): 316L
Single rod probe (Ø 16mm): 316L
Soft cable probe (Ø 6mm): 1.4401 (316)
Shell: PBT plastic, aluminum casting powder coating, 316L
Dielectric constant:>1.4 (coaxial probe),>1.7 (single rod probe, flexible cable probe)
Environmental temperature: -40 ℃~+80 ℃ (without display and adjustment module), -20 ℃~+70 ℃ (with display and adjustment module)
Working pressure: -1 to 40 bar (depending on the type of process interface)
Power supply: 14-36VDC (non explosion proof), 14-30VDC (intrinsic safety), 20-36VDC (explosion-proof)
Output signal: 4-20mA, optional for HART, Profibus PA, and FF buses
Alarm signal: The current is output at a fixed value of 20.5mA, 22mA, or<3.6mA, adjustable
Integral time: 0-999 seconds, adjustable
Resolution: 1.6 µ A
Accuracy: ± 3mm (coaxial probe: -20 ℃~+250 ℃);
± 5mm (coaxial probe: -200 ℃~+400 ℃, single rod probe, flexible cable probe);
Blind spot: coaxial probe: 50mm (top), single pole probe: 150mm (top);
Soft cable probe: 150mm (top)+350mm (bottom)
Load: 250 Ω when U0=20V, 750 Ω when U0=30V, 1000 Ω when U0=36V
Display section: Dot matrix LCD display, 4 buttons, protection level IP20/40, main body made of ABS material, window made of polyester foil lining material
Measurement length: Coaxial probe (Ø 43mm Ø 21.3mm): 0.3m~6m
Single pole probe: (Ø 16mm): 0.5m-6m, single pole probe (Ø 6mm): 0.5m-4m
Soft cable probe: (Ø 6mm): 1m~60m, soft cable probe (Ø 4mm): 1m~32m