AB930-3/6 type winding interturn impulse withstand voltage tester (desktop)
Electric motors, power tools, and other electrical appliances are mainly composed of coil windings. Due to differences in structure, selection of insulation materials, and manufacturing processes, insulation damage may occur to varying degrees between turns during the winding manufacturing process.
This device is designed specifically for the motor manufacturing industry to perform national standard measurement winding turn to turn insulation tests.
AB930-3/6 type winding turn to turn impulse withstand voltage tester (desktop) main features:
1. Meet the relevant technical requirements in national and industry standards
2. High output energy, especially suitable for measuring large capacity motors and transformers
3. It has functions such as switching between forward and reverse tests and switching between windings
4. Using a digital storage oscilloscope
5. Suitable for the detection of coil windings in single/three-phase AC/DC motors, etc
6. Can clearly and quickly locate inter turn short circuits for timely repair
| model |
Test voltage (KV) |
Frequency (HZ) |
Wavefront time (μ s) |
Energy storage capacitor (μ F) |
Applicable motors |
| AB930-3 |
0.3~3 |
twenty-five |
0.1~0.5±30% |
0.033~0.1 |
Below 380V |
| AB930-6 |
0.3~6 |
Below 1100V |