| Product name: | UZZ-02 Heavy hammer level gauge | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Level controller | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
The UZZ-02 heavy hammer level gauge measures a four digit digital display and can provide remote current output.
It has both upper limit alarm and lower limit alarm functions, with high accuracy in alarm setting and simple operation.
The timing range is large and can also be manually measured.
Empty measurement (addition counting) or full measurement (subtraction counting) can be set arbitrarily.
Six indicator lights indicate the operating status.
The working parameters are inputted through the keyboard.
Technical specifications of UZZ-02 heavy hammer level gauge
Measurement range: up to 60m
Measurement accuracy: ± 1% ± 2 of the displayed number;
Display ± 1.5% ± 2 numbers
Detection speed: 6-8m/min (single-phase power supply type)
Detection strip: stainless steel strip
Heavy hammer: galvanized iron chain, weighing approximately 5kg
Number display: four digits, including two decimal places, in meters
Remote transmission output: 0-10mADC, load 0-1k Ω
4~20mADC, Load 0-500 Ω
Timing range: 0.5min to 83.3h
Upper limit alarm: Full range setting, contact capacity: 220VAC, 1A (resistive load)
Lower limit alarm: Full range setting, contact capacity: 220VAC, 1A (resistive load)
Environmental temperature: Sensor: -25 to+55 ℃
Control display table: 0~+45 ℃
Medium temperature: -25 to+70 ℃; 5~200℃
Power supply: Sensor: three-phase 380V, 50Hz; Single phase 220V, 50Hz
Control display table: 220V, 50Hz
Transmission distance between sensors and control display tables: maximum 1.5km
Connecting cable: It is recommended to use RVVP10 × 12/0.15 ten core PVC insulated sheathed wire
schematic diagram
Installation Diagram