The UYZ-50 series capacitor level gauge is suitable for continuous measurement and indication of liquid levels of conductive and non-conductive media and powder materials in various storage tanks and containers during industrial production processes.
The output current of the instrument from 0 to 10mA can be connected to an ammeter or DDZ-II display control instrument. No point in the circuit must be grounded, otherwise an isolator must be used to match the computer input terminal.
Technical Indicators:
Accuracy: Non explosion proof ± 1%
Explosion proof type ± 1.5%
Measurement range: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0m (UYZ-561B model can have four measurement ranges of 3.0, 4.0, 6.0, 10m).
Load resistance: 1.5k Ω
Output signal: 0-10mADC
Power supply: 220VAC (+10%/-15%) 50Hz
Medium pressure: 2.5Mpa
Working environment: Sensor temperature -40~+85 ℃, relative humidity 10~95%
Display instrument temperature 0-45 ℃, relative humidity 10-90%
High and low level alarm fixed-point error: ± 2.5%
Range of high and low alarm set points: any given value within the full range of 0-100%
High and low level alarm contact capacity: 220VAC 3A
Explosion proof type selected explosion-proof barrier model: DFA-3100 detection terminal Zener safety barrier
Explosion proof grade of explosion-proof instrument: ia Ⅱ CT6
Model representation
UYZ-5□□□□
|
50 series code |
□ Measurement electrode form |
□ Medium temperature range |
□ Migration |
□ Explosion proof grade |
|
1) Insulated type
2) Coaxial bare pole type
3) Naked pole type
4) Coaxial insulated type
5) Separate type
6) Insulated rope type |
1) Standard: -40 to+85 ℃
2) High temperature: 85-200 ℃
3) Low temperature: I-100 to -40 ℃
4) Low temperature: II-156 to -100 ℃
5) Low temperature: Ⅲ -200~-156 ℃ |
A) Microcapacitors ranging from 6 to 50pF
B) Medium capacitance 30-1300pF |
iaⅡCT6 |