| Product name: | XMF series intelligent flow accumulation control instrument | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Flow integrator | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
project |
Instructions |
code |
Code Description |
|
A |
model |
XMF- |
Intelligent flow accumulation control instrument |
|
B |
output effect |
one |
Single display |
|
two |
Single display with analog transmission output | ||
|
C |
Control Function |
0 |
Single display (no alarm) |
|
one |
Binary (upper or lower limit) | ||
|
two |
Three position control (upper limit, lower limit) | ||
|
D |
Compensation Function |
0 |
Uncompensated input |
|
1- |
Compensated input | ||
|
2- |
Overheated steam with temperature and pressure compensation input - lookup table method | ||
|
3- |
Saturated steam with pressure compensation input - lookup table method | ||
|
4- |
User specific curve compensation input table lookup method | ||
|
E |
traffic signal input type |
one |
Standard signal: 0~10mA DC |
|
two |
Standard signal: 0~5V DC | ||
|
three |
Standard signal: 4~20mA DC | ||
|
four |
Standard signal: 1~5V DC | ||
|
five |
Pulse: 0~5KHz | ||
|
six |
User specific | ||
|
seven |
Pulse collector open circuit (0~5KHz) | ||
|
F |
temperature compensation input type |
0 |
No temperature compensation |
|
one |
Thermocouple type (E, K) | ||
|
two |
Thermal resistance type (Pt100) | ||
|
G |
pressure compensation input type |
0 |
No pressure compensation |
|
1- |
Standard signal: 0~10mA DC | ||
|
2- |
Standard signal: 0~5V DC | ||
|
3- |
Standard signal: 4~20mA DC | ||
|
4- |
Standard signal: 1~5V DC | ||
|
H |
output Signal |
0 |
Uncontrolled output |
|
one |
Standard signal: 0~10mA DC | ||
|
two |
Standard signal: 4~20mA DC | ||
|
three |
Standard signal: 1~5V DC | ||
|
four |
Standard signal: 0~5V DC | ||
|
five |
SCR - Zero crossing trigger pulse | ||
|
six |
SSR Solid State Relay | ||
|
I |
Communication Method |
0 |
No communication interface |
|
2- |
Equipped with RS-232 communication interface | ||
|
4- |
Equipped with RS-485 communication interface | ||
|
J |
First alarm Method |
N |
No alarm (can be omitted) |
|
H |
upper limit alarm | ||
|
L |
Lower limit alarm | ||
|
B |
Flow quantification to control - automatic start | ||
|
C |
Flow Quantitative Process Control - Automatic Start | ||
|
D |
Flow quantification to control - automatic reset | ||
|
K |
Second alarm Method |
N- |
No alarm (can be omitted) |
|
H- |
upper limit alarm | ||
|
L- |
Lower limit alarm | ||
|
B- |
Quantitative flow to control - manual start | ||
|
C- |
Quantitative flow process control - manual activation required | ||
|
L |
Appearance structure |
SM |
Vertical table: 80 × 160 × 140 (width × height × depth) |
|
M |
Horizontal chart: 160 × 80 × 140 (width × height × depth) | ||
|
F |
Square table: 96 × 96 × 100 (width × height × depth) |