Product name: |
BDL Thin type power transmitter
|
|
specification: |
|

Zoom in on the image |
|
Category: |
instrumentation and meters
-- SENECA Transducers |
|
Price: |
factory price |
|
Brand: |
Shanghai |
|
Place of Origin: |
China |
|
Available Quantity: |
batch |
|
delivery cycle: |
Spot goods (or inquire by telephone) |
|
| |
Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058 |
91way@163.com
13901609058(Wechat) |
|
|
|
BDL Thin type power transmitterDetailed product description:

characteristic
Usage: BDL thin electric quantity transmitter is a device that isolates and converts current and voltage parameters in the power grid into linear DC analog signals.
Measurement: single-phase, three-phase AC current/voltage
Accuracy: AC ± 0.2% RO
Output: Analog signals such as 0~20mAdc, 4~20mAdc, 0~10Vdc, 0~5VDC, etc
Detailed description of BDL thin power transmitter:
Technical parameters
AC input: Voltage: 100V, 150V, 220V, 380V, 600V Current: 1A, 5A
Input load: Voltage transformer PT: ≤ 0.1VA Current transformer CT: ≤ 0.2VA
Allowable overload: voltage multiplied by 2 times the nominal value continuously; Current multiplied by 2 times the nominal value continuously; Current multiplied by 10 times the nominal value for 10 seconds
Accuracy: ≤± 0.2% RO
Response time: ≤ 400ms
Output voltage: 0~10Vdc, 0~5VDC (load resistance=input voltage/10mADC)
Output current: 0~20mAdc, 4~20mAdc (load resistance=10Vdc/output current)
Output ripple: ≤ 0.5% RO peak to peak value
Working environment temperature and humidity: 0~50 ℃/less than 80% relative humidity (non condensing state)
Storage environment temperature and humidity: -20~70 ℃/less than 70% relative humidity (non condensing state)
Use power supply; AC220 ± 10%, 50Hz can be customized with special specifications (DC12V, 24V, 48V, 110V, 220V ± 20%)
Isolation: Input/Output/Power/Enclosure
Power consumption: DC about 3W, AC about 4VA
Shell material: ABS fireproof material
Pressure resistance strength: AC2KVrms/min
Insulation impedance: greater than 100M Ω at DC500V
Dimensions: Single phase 120 (L) × 23 (W) × 92 (H) mm, three-phase 119 (L) × 109 (W) × 75 (H) mm
Installation method: 35mm standard guide rail, base screw installation
Common specification examples
Model:HAT-12-A5-A1-A2 ;
Class: ±0.2%
Input: 1P2W, 5Aac, 50Hz;
Output:4~20mAdc
Aux.power:AC220V
Description: This model is a single-phase current transmitter with a 5Aac current transformer (CT) ratio current signal input and an output of 4-20mAdc. The working power supply is AC220

Related Products: