| Product name: | UTD3025C Digital Storage Oscilloscope | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- oscilloscope | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
Technical specifications of UTD3025C digital storage oscilloscope
| Basic functions | technical indicators | |
| channel | two | |
| bandwidth | 25MHz | |
| sampling method | ||
| Real time sampling | 250MS/s | |
| Waveform capture rate | 2000wfs/s | |
| input | ||
| Input coupling | DC, AC, Ground (DC, AC, GND) | |
| input impedance | 1 ± 2% Μ Ω, parallel with 30 ± 3pF | |
| Probe attenuation coefficient setting | 1X,10X,100X,1000X | |
| Maximum input voltage | 400V (DC+AC peak, 1 Μ Ω input impedance) (10:1 probe attenuation) | |
| Isolation between channels | Better than 40:1 | |
| Inter channel time delay (typical) | 150ps | |
| level | ||
| Waveform interpolation | sin(x)/x | |
| Recording and Storage | Storage depth: 1M sampling points | |
| Scanning range (S/div) | 20ns/div ~ 50s/div, 1-2-5 base (60MHz \ 80MHz \ 100MHz) | |
| Sampling rate and delay time accuracy | ± 50ppm (any time interval ≥ 1ms) | |
| Time interval (△ T) measurement accuracy (full bandwidth) | Single time: ± (1 sampling interval+50ppm x reading+0.6ns)>16 average values: ± (1 sampling interval+50ppm x reading+0.4ns) | |
| vertical | ||
| Analog to Digital Converter (A/D) | 8-bit resolution, simultaneous sampling of two channels | |
| Deflection coefficient | 2mV/div~10V/div (at input BNC) | |
| Displacement range | ±10div | |
| Simulate bandwidth | 25MHz | |
| Low frequency response (AC coupling, -3dB) | ≤ 10Hz (on BNC) | |
| Rise time (typical on BNC) | ≤14ns | |
| DC gain accuracy | 2mv/div, ± 4% at 5mv/div (sampling or average sampling method); When 10mv/div~10v/div: ± 3% (sampling or average sampling method) | |
| DC measurement accuracy (average sampling method) | When the vertical displacement is zero and N ≥ 16: ± (4% x reading+0.1div+1mV); Vertical deflection coefficient ≥ 5mV/div; When N ≥ 16: ± [3% x (reading+vertical displacement reading)+(1% x vertical displacement reading)]+0.2div) vertical deflection coefficient from 2mV/div to 200mV/div plus 2mV; vertical deflection coefficient from 500mV/div to 10div plus 50mV | |
| Voltage difference (Δ V) measurement accuracy (average sampling method) | Under the same settings and environmental conditions, after taking the average of ≥ 16 captured waveforms, the voltage difference (Δ V) between any two points on the waveform is ± (3% x reading+0.05div) | |
| trigger | ||
| Trigger sensitivity | ≤1div | |
| Trigger level range | internal | ± 5div from the center of the screen |
| EXT | ±3V | |
| EXT/5 | ±15V | |
| Trigger level accuracy (typical) applies to signals with rise and fall times ≥ 20ns | internal | ± (0.3div × V/div) (within ± 4div from the center of the screen) |
| EXT | ± (6% set value+40mV) | |
| EXT/5 | ± (6% set value+200mV) | |
| Pre triggering capability | Normal mode/scanning mode, pre trigger/delayed trigger, pre trigger depth adjustable | |
| Release range | 100ns-1.5s | |
| Set the voltage level to 50% (typical) | Operation under the condition of input signal frequency ≥ 50Hz | |
| Edge triggered | ||
| edge type | Rising and falling | |
| Pulse width triggering | ||
| trigger mode | (greater than, less than, equal to) positive pulse width, (greater than, less than, equal to) negative pulse width | |
| Pulse width range | 40ns-20s | |
| Video trigger | ||
| Trigger sensitivity (video triggered, typical) | internal | 2div peak to peak value |
| EXT | 400mV | |
| EXT/5 | 2V | |
| Signal format and line/field frequency (video trigger type) | Supports standard NTSC and PAL formats, with a line range of 1-525 (NTSC) and 1-625 (PAL) | |
| Alternating triggering | ||
| CH1 trigger | Edge, pulse width, video | |
| CH2 trigger | Edge, pulse width, video | |
| measurement | ||
| cursor | Manual mode | Voltage difference between cursor (Δ V), time difference between cursor (Δ T), reciprocal of Δ T (Hz) (1/Δ T) |
| tracking mode | Voltage and time values of waveform points | |
| automatic measurement | Measurement of peak to peak value, amplitude, maximum value, minimum value, top value, bottom value, average value, root mean square value, overshoot, overshoot, frequency, cycle, rise time, fall time, positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, delay 1->2 (rise), delay 1->2 (fall) | |
| Mathematical operations | Add, subtract, multiply, divide FFT | |
| Store waveform | 28 sets of waveforms, 28 settings | |
| FFT | Window | Hanning,Hamming,Blackman,Rectangular |
| sampling point | 2×512 points | |
| Lissajous figure | phase difference | ±3 degrees |
| display | ||
| display type | Diagonal 145 mm (5.7 inches) LCD display | |
| Display Resolution (Display) | 320 horizontal x RGB x 240 vertical pixels (color screen) | |
| Display color | colorful | |
| Display contrast | adjustable | |
| Backlight intensity (typical) | 300nit | |
| Display language types | Simplified Chinese, Traditional Chinese, English | |
| Probe compensator output | ||
| Output voltage (typical) | About 3V, peak to peak ≥ 1M Ω load | |
| Frequency (typical) | 1kHz | |
| Interface functionality | ||
| Standard Configuration | 1 USB (D); 1 USB (H); 1 Pass/Tail | |
| Optional accessories | GPIB and LAN | |
| power supply | ||
| power supply voltage | 100-240 ACRMS 45Hz to 440Hz, CAT II | |
| power consumption | Less than 30VA | |
| fuse | F1.5AL 250V | |
| environment | ||
| temperature | Operation: 0 ℃~+40 ℃ | |
| Non operational: -20 ℃ to+60 ℃ | ||
| Cooling method | natural cooling | |
| humidity | +10℃~+30℃:≤95%±5%RH, | |
| +30℃~+40℃:≤75%±5%RH | ||
| height | Operate 3000 meters | |
| Non operational 15000 meters | ||
| Mechanical Specifications | ||
| size | 320mm (width) x 150mm (height) x 292mm (depth) (body size) 430 x 380 x 540 mm (standard packaging size) | |
| Weight (net weight) | fuselage | 4.9kg, without packaging: 6.8kg |
| 2 units including packaging | 14.8 kg (gross weight of standard packaging) | |
| IP protection | IP2X | |
UTD3025C Digital Storage Oscilloscope