HomeYour location:Hometransformer equipmentpower transformerOil immersed transformer → 10KV single-phase distribution transformer
Column tabs 
Product name: 10KV single-phase distribution transformer
specification: 10KV single-phase distribution transformer
  Zoom Zoom in on the image
Category: transformer equipment -- Oil immersed transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


10KV single-phase distribution transformerDetailed product description:Column tabs
Description of 10KV single-phase distribution transformer:

The 10KV single-phase distribution transformer adopts a fully sealed corrugated oil tank structure, and the transformer oil constantly contacts the surrounding air, so the transformer oil will not absorb external moisture, thus not reducing the insulation strength; In addition, due to the inability of oxygen to enter the fuel tank, the aging of insulation materials is avoided, which improves the service life of the product.
10KV single-phase distribution transformers shall comply with the national standards GB1094 "Power Transformers", GB/T6451 "Technical Parameters and Requirements for Three phase Oil immersed Power Transformers", and JB/10317-02 "Technical Parameters and Requirements for Single phase Oil immersed Distribution Transformers".

The D9-M.R-5-100/10 series is a single-phase oil immersed R-type coiled iron core distribution transformer. The single-phase iron core is an R-type single frame double core column rolled structure, with spot welding on the outermost layer without binding. The iron core material is selected from cold-rolled silicon steel sheets such as DQ-133-30 (Type 9), 30ZH120 (Type 11), and 23ZH90 (Type 13). The iron core material used in actual production shall not be lower than the requirements of the drawing. The allowable deviation width for longitudinal cutting of iron core sheets is 0.2mm, and the shear burrs are less than 0.03mm. The iron core is continuously rolled without joints. The width of the R-type iron core ensures that the cross-section of the iron core is circular. After the iron core is rolled, it is vacuum annealed to eliminate stress and reduce losses.

Rated capacity
kVA
Winding connection group
label
Voltage combination
No load current%
No load loss W
load loss
(75℃)W
Short circuit impedance%
High voltage kV
High voltage tap range%
Low voltage kV
five
Ⅱ0
ten
±2×2.5%
2×0.24
four
thirty-five
one hundred and forty-five
three point five
ten
three point five
fifty-five
two hundred and sixty
sixteen
three point two
sixty-five
three hundred and sixty-five
twenty
three
eighty
four hundred and thirty
thirty
two point eight
one hundred
six hundred and twenty-five
forty
two point five
one hundred and twenty-five
seven hundred and seventy-five
fifty
two point three
one hundred and fifty
nine hundred and fifty
sixty-three
two point one
one hundred and eighty
one thousand one hundred and thirty-five
eighty
two
two hundred
one thousand one hundred and forty
one hundred
one point nine
two hundred and forty
one thousand six hundred and fifty

10KV single-phase distribution transformer
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference