Technical specifications of PA-24 three-phase voltage transmitter
Input load: Voltage transformer PT: ≤ 0.1VA
Overload capacity: can withstand 2 times the rated value (continuous), 10 times the rated value (10s)
Accuracy: AC: ± 0.2%, ± 0.5%
Response time: < 400ms
Output voltage: 0~10Vdc, 0~5VDC (load resistance=input voltage/10mAdc)
Output current: 0~20mAdc, 4~20mAdc (load resistance=10Vdc/output current)
Output ripple: ≤ 0.5% RO
Working environment temperature: 0~50 ℃/less than 80% relative humidity (non condensing state)
Storage environment temperature and humidity: -20~70 ℃/less than 70% relative humidity (non condensing state)
Pressure resistance strength: AC2KVrms/min
Insulation impedance: greater than 100M Ω at DC500V
Electromagnetic compatibility: Complies with GB/T18268 industrial equipment application requirements (equivalent to IEC61326-1)
Power consumption: approximately 2VA
installation dimensions

Selection code

wiring diagram