FDF-MG series solenoid valveDetailed product description:Column tabs
Overview
FDF-MG solenoid valve is a new type of solenoid valve developed for R410A refrigerant, used in liquid pipelines, suction pipelines, and hot steam pipelines, as well as other fluorides.

characteristic
FDF-MG type solenoid valve is a servo type solenoid valve, suitable for liquid pipelines, suction pipelines, and hot steam pipelines of fluoride refrigerants.
Electromagnetic valves are suitable for refrigeration, freezing, and air conditioning units.
There are various AC and DC voltage coils to choose from.
Suitable for R410A and other HCFCs, HFC refrigerants (except R717) and compatible lubricating oils.
The applicable working fluid temperature is -40 ℃ to+105 ℃, and the highest temperature during defrosting is+130 ℃.
Applicable ambient temperature range: -40 ℃ to+55 ℃.
The maximum working pressure is 45 bar.
Hydraulic resistance strength ≥ 68bar.
UL/CUL certification is available.

FDF-MG series solenoid valve models and parameters Technical data

Model
Model
Takeover method
Form
of Connection
Takeover dimensions
Connection Size
Valve opening pressure difference
Opening diff pressure(bar)
Kv value
Kv Value
mthree/h
Maximum safe working pressure
Max working pressure
(bar)
Overall dimensions
Dimensions(mm)
Rated power type
mm
ODF
in
ODF
minimum
Min
Maximum (water)
Max(liquid)
L
mm
W
mm
H
mm
AC
DC
AC voltage
50/60Hz AC
DC voltage
DC
FDF3G
welded type
six
1/4
0
twenty-eight
twenty-four
zero point two seven
forty-five
one hundred and seventeen
thirty-one
seventy-six
twenty-four
thirty-six
one hundred and ten
two hundred and twenty
twelve
twenty-four
one hundred and ten
two hundred and twenty
ten
3/8
FDF6MG
ten
3/8
zero point zero five
zero point eight
one hundred and twenty-seven
thirty-two
eighty
twelve
1/2
sixteen
5/8
FDF8MG
ten
3/8
one
one hundred and thirty-seven
thirty-eight
eighty-eight
twelve
1/2
one hundred and thirty-seven
sixteen
5/8
one hundred and sixty-two
FDF10MG
twelve
1/2
one point eight
one hundred and thirty-seven
forty-five
eighty-eight
sixteen
5/8
one hundred and sixty-six
FDF15MG
nineteen
3/4
three
one hundred and seventy-four
fifty-two
ninety-six
twenty-two
7/8
FDF20MG
twenty-two
7/8
five
one hundred and ninety
fifty-eight
one hundred and fifteen
twenty-two
7/8 (Extended)
two hundred and thirty
twenty-eight
9/8
two hundred and fifty

Kv value: The flow rate, unit m3/h, and density ρ=1000 kg/m3 of water passing through an electromagnetic valve with a pressure difference of 1 bar
Note: If you need other working characteristics and specifications of products, please contact our company.

Model and Parameters Technical Date

Nominal Liguid Capacity (k) w
Model
Model
Liquid Liguid
Inhalation suction
Hot Steam
R22
R134a
R404A
R507
R407c
R410A
R22
R134a
R404A
R507
R407c
R410A
R22
R134A
R404A
R507
R407c
R410A
FDF3G
six point two
three point nine
three point seven
five point seven
six point four eight
zero point six seven five
zero point five four
zero point four zero
zero point six two
zero point seven zero two
two point nine two
two point three two
one point seven three
two point six six
three point zero two
FDF6MG
eighteen point four
fourteen point seven
eleven
sixteen point eight
nineteen point two
two
one point six
one point two
one point eight four
two point zero eight
eight point six four
six point eight eight
five point one two
seven point eight nine
eight point nine six
FDF8MG
twenty-three
eighteen point four
thirteen point eight
twenty-one
twenty-four
two point five
two
one point five
two point three
two point six
one point eight
eight point six
six point four
nine point eight seven
eleven point two
FDF10MG
forty-three point seven
thirty-five
twenty-six point two
thirty-nine point nine
forty-five point six
four point eight
three point eight five
two point eight eight
three point nine nine
five point zero two
twenty point five four
sixteen point four five
twelve point one five
eighteen point six three
twenty-one point three
FDF15MG
sixty-nine
fifty-five point two
forty-one point four
sixty-three
seventy-two
seven point five nine
six point zero seven
four point five five
six point nine three
seven point nine two
thirty-two point two four
twenty-five point eight
nineteen point three five
twenty-nine point four two
thirty-three point six five
FDF20MG
one hundred and three point five
eighty-two point eight
sixty-two point one
ninety-four point five
one hundred and eight
eleven point three eight
nine point one zero
six point eight three
ten point three nine
eleven point eight eight
forty-eight point three seven
thirty-eight point seven
twenty-nine point zero two
forty-four point one seven
fifty point four eight


The nominal cooling capacity of liquid and suction is: The nominal cooling capacity of hot gas operating conditions are:
Evaporation temperature te=4.4 ℃ Condensation temperature tc=+40 ℃
The liquid temperature in front of the valve is t1=38 ℃, and the pressure drop across the valve is Δ P=0.8bar
By reducing the pressure of R134a Δ P=0.15bar through the solenoid valve, the temperature of the hot steam th=+65 ℃
R22, R404A, R507, R407c, R410A Δ P=0.21bar Liquid refrigerant subcooling Δ tsub=4K

Installation
The solenoid valve should be installed vertically on a horizontal pipeline, and the direction of medium flow should be consistent with the arrow direction indicated by the solenoid valve.  
The input voltage for coil operation must be consistent with the rated voltage indicated on the coil. Never allow the solenoid coil to be removed from the valve when it is powered on, in order to prevent the coil from burning out.  
When welding electromagnetic valve welded pipes with system pipes, the following points must be noted:
Remove the solenoid coil from the valve and wrap it around the valve body with a damp cloth or cotton yarn to protect it from overheating and damaging the valve components during welding.  
Please pay attention to the direction of the welding gun flame during welding.  
It is best to use high silver welding rods for welding.  
The solenoid valve with a manual lever must first rotate the manual lever to open the valve, and then conduct a system air tightness test to avoid damaging the diaphragm.

Installation diagram of FDF-MG series solenoid valve
FDF-MG series solenoid valve appearance and installation dimensions
FDF-MG series solenoid valve dimensions

FDF-MG series solenoid valve