| Product name: | FDF-M type solenoid valve | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- solenoid valve | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Model
Model |
connection size
Connection size |
connection method
Form of connect |
Valve opening pressure difference (bar)
Opening diff pressure |
Flow rate (water)
Flow rate Kv(m3/h) |
working medium
Available
medium |
Medium temperature ℃
Temperature of media |
Type of power supply
Rated power |
Overall dimensions
Dimensions (mm) | |||||||
|
Normally closed (NC) |
Normally open (NO) | ||||||||||||||
|
In |
mm |
AC |
DC |
long |
wide |
high |
long |
wide |
high | ||||||
|
FDF3BJ |
1/4 |
six |
Welding
ODF |
normally closed
Communication: 0.05-21
DC: 0.05-17
Normally Open
Communication: 0.05-18
DC: 0.05-15
|
zero point two seven |
CFC
HCFC
HFC
air
clean water
Oil with viscosity ≤ 4 ° E |
-25—105 |
twenty-four
thirty-six
one hundred and ten
two hundred and twenty |
twelve
twenty-four
one hundred and ten
two hundred and twenty |
one hundred and seventeen |
thirty-one |
seventy-six |
|||
|
5/16 |
eight | ||||||||||||||
|
3/8 |
ten | ||||||||||||||
|
FDF6MJ |
5/16 |
eight |
zero point four |
one hundred and twenty-seven |
forty-five |
eighty-eight |
one hundred and twenty-seven |
forty-five |
ninety-three | ||||||
|
FDF8MJ |
3/8 |
ten |
zero point eight | ||||||||||||
|
1/2 |
twelve |
zero point eight | |||||||||||||
|
FDF10MJ |
1/2 |
twelve |
one point nine |
one hundred and fifty-one |
forty-five |
eighty-six |
one hundred and fifty-one |
forty-five |
ninety-one | ||||||
|
5/8 |
sixteen |
one point nine | |||||||||||||
|
FDF13MJ |
5/8 |
sixteen |
three |
one hundred and seventy-four |
fifty-two |
ninety-eight |
one hundred and seventy-four |
fifty-two |
one hundred and fifteen | ||||||
|
3/4 |
nineteen |
three | |||||||||||||
|
7/8 |
twenty-two |
three | |||||||||||||
|
FDF16M1 |
3/4 |
nineteen |
four point five |
one hundred and ninety |
fifty-eight |
ninety-eight |
one hundred and ninety |
fifty-eight |
one hundred and fifteen | ||||||
|
FDF19M1 |
7/8 |
twenty-two |
four point five | ||||||||||||
|
FDF19M2 |
7/8 |
twenty-two |
five |
two hundred and thirty |
seventy-two |
one hundred and eight |
two hundred and thirty |
seventy-two |
one hundred and twenty-five | ||||||
|
FDF19M3 |
11/8 |
thirty-five |
six |
two hundred and fifty |
seventy-two |
one hundred and eight |
two hundred and fifty |
seventy-two |
one hundred and twenty-five | ||||||
|
FDF19M4 |
9/8 |
twenty-eight |
six | ||||||||||||
|
FDF25MJ |
9/8 |
twenty-eight |
nine point eight |
two hundred and thirty-six |
seventy-two |
one hundred and sixteen |
two hundred and thirty-six |
seventy-two |
one hundred and thirty-three | ||||||
|
11/8 |
thirty-five |
nine point eight | |||||||||||||
|
FDF32MJ |
11/8 |
thirty-five |
fifteen |
two hundred and eighty-one |
eighty-six |
one hundred and thirty |
two hundred and eighty-one |
eighty-six |
one hundred and forty-seven | ||||||
|
13/8 |
forty-two |
fifteen | |||||||||||||
|
FDF40M |
13/8 |
forty-two |
normally closed
Communication: 0.3-21
DC: 0.3-17
Normally Open
Communication: 0.3-18
DC: 0.3-15
|
twenty-five
|
three hundred and twenty-two |
one hundred and twenty-six |
one hundred and fifty-eight |
three hundred and twenty-two |
one hundred and twenty-six |
one hundred and seventy-one | |||||
|
17/8 |
fifty-four | ||||||||||||||
|
FDF25MA |
thirty-three |
flange
Flange
|
normally closed
Communication: 0.05-21
DC: 0.05-17
Normally Open
Communication: 0.05-18
DC: 0.05-15
|
nine point eight |
one hundred and fifty-two |
one hundred and twelve |
one hundred and sixty-five |
one hundred and fifty-two |
one hundred and twelve |
one hundred and eighty-two | |||||
|
FDF25MF |
thirty-three |
nine point eight |
one hundred and sixty-two |
eighty-six |
one hundred and seventy-five |
one hundred and sixty-two |
eighty-six |
one hundred and ninety-two | |||||||
|
FDF32MA |
thirty-eight point eight |
fifteen |
one hundred and sixty-two |
one hundred and twelve |
one hundred and seventy-five |
one hundred and sixty-two |
one hundred and twelve |
one hundred and ninety-two | |||||||
|
FDF32MF |
thirty-eight point eight |
fifteen |
one hundred and fifty-six |
eighty-six |
one hundred and seventy-eight |
one hundred and fifty-six |
eighty-six |
one hundred and ninety-five | |||||||
|
FDF3B |
six |
thread
SAE
|
zero point two seven |
sixty |
thirty-one |
seventy-six |
|||||||||
|
FDF6MB |
eight |
zero point four |
eighty-five |
forty-five |
eighty-five |
eighty-five |
forty-five |
ninety | |||||||
|
FDF8MB |
ten |
zero point four | |||||||||||||
|
FDF10MBJ |
twelve |
zero point eight |
eighty-seven |
forty-five |
eighty-five |
eighty-seven |
forty-five |
ninety | |||||||
|
FDF13MBJ |
sixteen |
one point nine |
one hundred and seven |
fifty-two |
ninety-eight |
one hundred and seven |
fifty-two |
one hundred and fifteen | |||||||
|
FDF16MBJ |
nineteen |
four point five |
one hundred and twenty-eight |
seventy-two |
one hundred and eight |
one hundred and twenty-eight |
seventy-two |
one hundred and twenty-five | |||||||
|
FDF19MBJ |
twenty-two |
six |
one hundred and twenty-eight |
seventy-two |
one hundred and eight |
one hundred and twenty-eight |
seventy-two |
one hundred and twenty-five | |||||||
|
FDF2Z |
ODM5/8 |
Right angle welding
Right-angle welding |
Communication: 0-25
|
zero point one six |
sixty-three point five |
thirty |
one hundred and thirty-two |
||||||||
|
FDF3Z |
ODM5/8 |
zero point two seven |
sixty-three point five |
thirty |
eighty-five |
||||||||||
Note: "E" after the model indicates a manual lever, "F" indicates a flange, "A" indicates a waist flange, "J" indicates an improved version, "B" indicates a threaded connection, "K" indicates a normally open solenoid valve, and "Z" indicates a right angle.
Note: If you need other working characteristics and specifications of products, please contact our company.
The Kv value is the water flow rate when the valve passes through a pressure drop of 1 bar before and after a pressure of ρ=1000kg/m3.
The nominal cooling capacity of liquid and suction is: The nominal cooling capacity of hot gas operating conditions are:
Evaporation temperature te=-10 ℃ Condensation temperature tc=+40 ℃ Liquid refrigerant subcooling degree Δ tsub=4K
The temperature of the liquid in front of the valve is t1=+25 ℃, and the pressure drop across the valve is Δ P=0.8bar
After the pressure drop of the solenoid valve Δ P=0.15 bar, the temperature of the hot steam th=+65 ℃