HomeYour location:Homeinstrumentation and metersDigital Display InstrumentAdjust control instruments → XMGZ/T series light column/digital display control instrument
Column tabs 
Product name: XMGZ/T series light column/digital display control instrument
specification: XMGZ/T series light column/digital display control instrument
  Zoom Zoom in on the image
Category: instrumentation and meters -- Adjust control instruments
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


XMGZ/T series light column/digital display control instrumentDetailed product description:Column tabs
The XMGZ/T series light column/digital display control instrument can be adapted to various thermocouples, thermistors, Hall transmitters, resistance remote pressure gauges, as well as various flow, pressure, liquid level and other transmitters to provide light column/digital linear and square root indication and control of thermal parameters in two circuits.

Main features and functions of XMGZ/T series light column/digital display control instrument:
1. Through simple software and hardware settings, it is possible to select the setting of functional parameters and control parameters such as division mark, range, decimal point position, and light column display range for each input. All set parameters can be permanently saved and data will not be lost in case of power failure.
2. Each relay control output can be programmed with its own upper limit, upper limit, lower limit, lower limit and other output control functions; The setting of each control value can be set within the full range.
3. Adopting an advanced fully automatic digital calibration system, precision calibration can be conveniently and quickly performed without the need for potentiometer adjustment. This improves the stability and consistency of the instrument.
4. The instrument display consists of a dual four digit digital display and a dual light column display, each displaying the measured values of its respective circuit. The display range of the light column should match the digital display range.
5. It has self diagnostic functions for faults such as over range, wire breakage, resistance breakage, and couple breakage indication.
6. It has isolated analog transmission output signals of 0~10mA, 4~20mA, 0~5V, and 1~5V. The analog transmission values can be programmed freely within their respective full range ranges.
7. It can be equipped with an isolated serial communication interface, and the transmission rate can be freely set through buttons. It can communicate bidirectionally with various devices with input/output communication functions and form a network control system.
8. Each set parameter and debugging parameter can be locked with a password, which can prevent accidental operation.
9. Instrument power supply mode: 220V AC linear power supply, 220V AC switch mode power supply, 24V DC switch mode power supply, or other user specific requirements.  

Type spectrum
Model identification: A-BCD-EFGH-I

project

Instructions

code

Code Description

A

model

XMGZ-

Light column/digital display, transmission output

XMGT-

Light column/digital display, control, transmission output

B

Type

three

Dual circuit light column/digital display, control

four

Dual circuit light column/digital display, transmission, control

C

call the police

Control

Method

0

Single display (without alarm control function)

one

One relay output (or one limit alarm)

two

Two relay outputs (or two limit alarms)

three

Three relay outputs (or three limit alarms)

four

Four relay outputs (or four limit alarms)

D

Input

Signal

Type

1-

(XY)

thermocouple

2-

(XY)

thermal resistor

3-

(XY)

Hall pressure remote transmission (or various mV signal inputs)

4-

(XY)

Resistance remote transmission pressure gauge

5-

(XY)

Standard signal: 0~10mA DC

6-

(XY)

Standard signal: 0~5V DC

7-

(XY)

Standard signal: 4~20mA DC

8-

(XY)

Standard signal: 1-5V DC

9-

(XY)

User specific requirements

E

Simulation

Transmission

output

Signal

Type

0

(XY)

No transmission signal output

one

(XY)

Standard signal: 0~10mA DC

two

(XY)

Standard signal: 4~20mA DC

three

(XY)

Standard signal: 1-5V DC

four

(XY)

Standard signal: 0~5V DC

F

Appearance

structure

M

Horizontal: 160 × 80 × 140 (width × height × depth)

SM

Vertical: 80 × 160 × 140 (width × height × depth)

G

Additional

Function

Missing item is no distribution output

D

Equipped with a 24V DC distribution output or a distribution voltage output as requested by the user

2D

Equipped with two 24V DC distribution outputs or user requested distribution voltage outputs

H

Communication

Method

Missing item is no communication interface

2-

Equipped with RS-232 communication interface

4-

Equipped with RS-485 communication interface

I

Power supply

Method

The missing item is a 220V AC linear power supply

T

220V AC switch power supply

W

24V DC switch power supply


Model example: XMGT-3477-00M2D4-T (i.e. A-BCD-EFGH-I)
Dual input: 4~20mA; four relays control output; Equipped with two 24V DC power distribution channels; Equipped with RS485 communication interface; Switching power supply 220V AC.
XMGZ/T series light column/digital display control instrument
  • Related product tags  Related Products:
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference