The PG100 intelligent pH (ORP) controller is used in conjunction with pH composite electrodes and pH transmitters to form an industrial pH detection system; Used in conjunction with ORP composite electrodes and ORP transmitters to form an industrial ORP detection system.
The PG100 intelligent pH (ORP) controller can choose between pH working mode or ORP working mode.
Independent two-way alarm output and one-way switch output.
The positive and negative effects of alarm and control can be selected separately.
Output signal: 0~10 V or 4~20 mA
One or two point automatic standard pH value.
Dual row LED display simultaneously.
Digital filtering can automatically remove signal interference and measurement noise, making the instrument more stable.
| Product Name and Model |
PG-100 Intelligent Digital PH (ORP) Controller |
| input signal |
0—5V.DC. 1~5V.DC. 1—100mA.DC. 4—20mA.DC |
| measurement range |
0~14.00pH.±1500mV |
| resolution |
0.01PH 1mV |
| accuracy |
PH: ± 0.05PH ± 1 word, mV: ± 0.5% FS ± 1 word |
| Display |
Double row digital display, capable of simultaneously displaying measured values, set values, or output quantities |
| alarm function |
Two way alarm output, can be set as upper limit alarm or lower limit alarm at will. The insensitive area can be adjusted at will |
| control function |
One way switch control strip, with optional positive and negative effects, and adjustable insensitive areas |
| Control action |
ON/OFF control |
| Correction function |
2-point automatic calibration (pH 4., 6.86, or pH 4.0, 9.18, or 6.86, 9.18 optional) |
| transmitter output |
0~10MA、DC, Or 4-20mA.DC |
| digital filtering |
Automatically remove signal interference and measurement noise, resulting in better instrument stability |
| power supply |
90—250V. AC |
| Overall dimensions |
92 x 92 x100mm |