F741B Process Multi functional Calibration InstrumentDetailed product description:Column tabs
Features of F741b process multifunctional calibrator:

Calibrate temperature, pressure, voltage, current, resistance, and frequency
A compact, sturdy, and reliable instrument can simultaneously output and measure.
Develop and operate As foundation/As left programs that meet international quality standards. Supports calibration of linear, square root transmitters and one point, two-point limit switches.
Record and archive calibration results
After the user returns the registration card, they will be able to use the latest functions reserved in the machine:
-Transmitter Mode - Barcode Reader
More intelligent and faster

Technical parameters of F741b process multifunctional calibrator:
Temperature, thermocouple, and platinum resistance
Type Measurement accuracy Output accuracy
10Ω Cu(427) 3℃ 1℃
100Ω Pt(3916) 0.3℃ 0.1℃
100Ω Pt(3926) 0.3℃ 0.1℃
100Ω Pt(385) 0.3℃ 0.1℃
200Ω Pt(385) 0.3℃ 0.1℃
500Ω Pt(385) 0.3℃ 0.1℃
1000Ω Pt(385) 0.3℃ 0.1℃
120Ω Ni(672) 0.3℃ 0.1℃
E 0.3℃ 0.2℃
N 0.5℃ 0.3℃
J 0.3℃ 0.2℃
L 0.3℃ 0.2℃
K 0.3℃ 0.3℃
T 0.3℃ 0.3℃
U 0.3℃ 0.3℃
B 0.9℃ 0.8℃
R 1.0℃ 0.9℃
S 0.9℃ 0.9℃
C 0.6℃ 0.6℃

Resolution: In the middle range, the best resolution is 0.1 ℃, except for 10 Ω Cu (427). Excluding the inaccuracy of sensors. When measuring with 2-wire and 3-wire RTDs, add 0.4 ℃. When measuring with a thermocouple, external reference junction compensation is used. If internal reference junction compensation is used, add 0.2 ℃.

measurement Source output
Range accuracy
(% reading+% full scale)
Range accuracy
(% reading+% full scale)
110.000 mV DC 0.025%+0.015% 110.000 mV 0.01% + 0.005%
1.10000V DC 0.025%+0.005% 1.10000V 0.01% + 0.005%
11.0000V DC 0.025%+0.005% 15.0000V 0.01% + 0.005%
110.000V DC 0.05%+0.005%
300.00V DC 0.05%+0.005%
V AC, 20 to 40 Hz 2%+10 counts
V AC, 40 to 500 Hz 0.5%+5
V AC, 500 to 1 kHz 2%+10
V AC, 1 kHz to 5 kHz 10%+20
30.000 mA DC 0.01%+0.015% Source 22.000 mA 0.01% +0.015%
110.00 mA DC 0.01%+0.015% Simulate 22.000 mA 0.02% + 0.03%
11.000Ω 0.05%+50 mΩ 11.000Ω 0.01% + 20 mΩ
110.00Ω 0.05% + 50 mΩ 110.00Ω 0.01% + 40 mΩ
1.1000 kΩ 0.05% + 0.5Ω 1.1000 kΩ 0.02% + 0.5Ω
11.000 kΩ 0.1% + 10Ω 11.000 kΩ 0.03% + 5Ω
1.00 to 109.99 Hz 0.05 Hz 0.00 to 10.99 Hz 0.01 Hz
110.0 to 1099.9 Hz 0.5 Hz 11.00 to 109.99 Hz 0.1 Hz
1.100 to 10.999 kHz 5 Hz 110.0 to 1099.9 Hz 0.1 Hz
11.00 to 50.00 kHz 50 Hz 1.100 to 21.999 kHz 2 Hz
22.000 to 50.000kHz 5 Hz

General indicators:
Data recording: Record voltage, mA, Resistance, frequency, temperature, pressure. 1 to 60 readings per second, with a maximum of 8000 readings per second.  
Ramp: When the output voltage, mA, Frequency, temperature, 4 steps per second; Provide round-trip detection function for voltage and on/off.  
Loop power supply: optional 24V or 28V, maximum 22mA
Environment: Temperature range of 741B/743B index+18 ℃~28 ℃
Operating temperature: -0 ℃~50 ℃ (typical index up to -20 ℃) The index of the pressure module is 0 ℃~50 ℃
Storage temperature: -20 ℃~60 ℃