HomeYour location:HomeSpecial electrical appliancesExplosion-proof sensor → GKD36V Mining explosion-proof and intrinsic safety feeding state sensor
Column tabs 
Product name: GKD36V Mining explosion-proof and intrinsic safety feeding state sensor
specification: GKD36V Mining explosion-proof and intrinsic safety feeding state sensor
  Zoom Zoom in on the image
Category: Special electrical appliances -- Explosion-proof sensor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


GKD36V Mining explosion-proof and intrinsic safety feeding state sensorDetailed product description:Column tabs
GKD36V mining explosion-proof and intrinsic safety feeding state sensor (hereinafter referred to as the sensor) is a type of mining explosion-proof and intrinsic safety protection equipment. Sensors can be used in conjunction with other related devices, with a power supply function that can monitor whether the disconnected device continues to work after a power outage.

Environmental Requirements for GKD36V Mining Explosion proof and Intrinsic Safety Feed State Sensor
The environmental conditions required for equipment use are as follows:
a) Environmental temperature: 0 ℃~40 ℃;
b) Humidity: ≤ 95%;
c) Atmospheric pressure: 80kPa~110kPa;
d) In Class I situations where there is a methane explosive gas mixture underground in coal mines, but there is no corrosive gas that damages insulation;
e) In situations where there is no significant vibration or impact.

Main technical specifications of GKD36V mining explosion-proof and intrinsic safety feeding state sensor
Supply voltage and current
a) Rated operating voltage: 18V.DC, operating voltage range: (13-24) V.DC;
b) Working current: ≤ 60mA.
Input/output signals
Feed input voltage
The input voltage range for power supply is (36-1140) V.AC.
Output signal 5mA/0mA current signal
a) When the device is powered on, the output current is (5 ± 0.5) mA;
b) When the device loses power, the output current is (0 ± 0.5) mA.
+5mA/-5mA current signal
a) When the device is powered on, the output current is (5 ± 0.5) mA;
b) When the device loses power, the output current is (-5 ± 0.5) mA.
Passive contact signal
a) Contact capacity: DC 24V/0.1A;
b) When the equipment loses power and the normally closed contact is disconnected (cut off), the leakage resistance between the two output terminals should not be less than 100k Ω.
c) When the device is powered, the normally open contact is closed (conductive), and the current injected is 2mA, the voltage between the two output terminals should not exceed 0.5V.
1/5mA current signal
a) When the device is powered on, the output current is (5 ± 0.3) mA;
b) When the device loses power, the output current is (1 ± 0.15) mA.
Signal transmission distance
When using a cable with a single core cross-sectional area of 1.5mm2, the maximum transmission distance between the sensor and associated equipment should not be less than 2km.