HomeYour location:HomeSpecial electrical appliancesExplosion-proof sensor → GJT100G(A) High concentration methane sensor
Column tabs 
Product name: GJT100G(A) High concentration methane sensor
specification: GJT100G(A) High concentration methane sensor
  Zoom Zoom in on the image
Category: Special electrical appliances -- Explosion-proof sensor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


GJT100G(A) High concentration methane sensorDetailed product description:Column tabs

The GJT100G (A) high concentration methane sensor (hereinafter referred to as the sensor) is developed to meet the needs of detecting high and low concentration methane in coal mine gas pipelines in China. The sensor can measure and display the methane concentration in the gas pipeline in real time, and generate sound and light alarm signals and power-off signals according to the concentration value, and output RS485 digital signals corresponding to the methane concentration. In addition to being used in conjunction with our KJ70N coal mine monitoring system, sensors can also be independently used in various mining fire detection systems.

Environmental requirements for the use of GJT100G (A) high concentration methane sensor
The sensor should be able to function properly under the following environmental conditions:
a) Environmental temperature: (0~+40) ℃;
b) Humidity: ≤ 98%;
c) Atmospheric pressure: (80-106) kPa;
d) In situations where there is no significant vibration, impact, or water splashing;
e) Wind speed: (0-8) m/s;
f) There is an explosive gas mixture of methane in coal mines, but there is no corrosive gas that can damage insulation.

Main technical specifications of GJT100G (A) high concentration methane sensor

Explosion proof form: intrinsic safety type, explosion-proof mark "Exib I Mb";
Measurement range: (0-100)% CH4;
Measurement error:
Response time: no more than 20 seconds;
Remote control distance: not less than 5m;
Alarm point: Alarm point setting range: The sensor should be able to be set arbitrarily within the range of (0.5-100)% CH4 (factory set to 1% CH4).
Power off point: (0.5-100)% CH4 can be set arbitrarily (factory setting is 1.5% CH4). When the power is turned off and the output is in a high-level state, the current pulled out is 2mA and the voltage is not less than 3V. When the output is in a low-level state, the voltage is less than 0.5V.
Output RS485 signal:
a) Transmission method: RS485
b) Transmission port: 1 channel
c) Transmission rate: 2400bps
d) Peak to peak communication voltage: (2-10) V
Working current: not exceeding 100 mA (note: must be under rated voltage DC 18 V conditions).
Calibration flow rate: 200ml/min.

Technical performance of GJT100G (A) high concentration methane sensor

GJT100G (A) high concentration methane sensor

GJT100G(A) High concentration methane sensor
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference