HomeYour location:Homeinstrumentation and metersSpecialized instruments and metersgas detection → PGM-50 Pump suction five gas detectors
Column tabs 
Product name: PGM-50 Pump suction five gas detectors
specification: PGM-50 Pump suction five gas detectors
  Zoom Zoom in on the image
Category: instrumentation and meters -- gas detection
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


PGM-50 Pump suction five gas detectorsDetailed product description:Column tabs
MultiRAE Plus PGM-50 American RAE pump suction five in one detector (combustible gas/oxygen/toxic gas/VOC organic)
Gas detection: combustible gas/oxygen/two toxic gases/VOC organic gas.  

Product Description: The MultiRAE Plus PGM-50 American RAE pump suction five in one detector is a flexible multi gas detector that can be configured with optional combustible LEL sensors, electrochemical oxygen/toxic gas sensors, and photoionization (PID) sensors. It is currently the only portable instrument on the market that can simultaneously detect combustible gases, toxic gases, and VOC gases.

The main features of PGM-50 pump suction five gas detector are:
• Can simultaneously detect combustible gases, oxygen, toxic gases, and volatile organic compounds.
Small size, light weight, easy to carry, stable and reliable performance, easy to operate and use.
• Automatic backlit display for easy use in dark environments
Built in powerful suction pump, using large capacity lithium and alkaline batteries, with long working time,
High brightness LED and loud sound alarm, high-capacity data acquisition.

Standard configuration: • PGM-50 host with specified sensors • Lithium battery, charger • Rubber protective cover, wristband
• Inlet pipe and water trap filter • Operating manual • Data and software CD • Portable soft bag

Optional accessories:
• Alkaline battery adapter • Calibration gas • Plug in pen type vibration alarm, headphones, thermal printer

Application areas: • Safety testing in gas, petroleum, petrochemical, and metallurgical industries • Safety testing in urban public utilities
• Industrial safety monitoring • Health and epidemic prevention investigation • Fire and environmental safety testing • Hazardous chemical substance testing
Special note: PID sensors must be configured

Technical parameter table of PGM-50 pump suction five gas detectors:

Product Model

MultiRAE Plus PGM-50

sampling method

pump-suction type

Shell material

Engineering plastics, rubber jackets

Protection Rating

IP55, Waterproof and dustproof

Electromagnetic radiation resistance

EMI/RF rating: EMC Directive 89/336/EEC

Operating Temperature

-20℃~45℃

Ambient Humidity

0% to 95% relative humidity (non condensing)

ATEX certification

EEx ia IIC T4

Certification

Class I, Division 1, Group A, B, C, D

display screen

2-line 16 character LCD display with automatic backlight

display language

English+Symbols

Display content

Sensor names (up to five), real-time detection values, highest and lowest values of all detections, TWA/SETL values (excluding oxygen and combustible gas), battery voltage, date and time, temperature

button

1 operation key, 2 function keys

alarm method

90dB@30cm Buzzer, LED flashing

alarm signal

High/low concentration alarm, TWA/SETL alarm (excluding oxygen and combustible gas), low battery level alarm, sensor malfunction alarm, pump blockage alarm

Alarm point setting

Set separate high/low alarm limits, TWA/SETL alarm limits (excluding oxygen and combustible gas)

data storage

Can store 20000 pieces of data (5 channels, with a 1-minute interval of 64 hours)

Sampling interval

Adjustable from 1 to 3600 seconds

data communication

Connect to a computer via RS232 interface for data download

Sampling pump flow rate

150cc/min~250cc/min

battery

4.8V 1100mAh rechargeable lithium-ion battery, alkaline battery box uses 4 AA batteries

Runtime

Can work continuously for 12 hours (depending on the working environment and frequency of use)

Charging time

10 hours

Calibration method

Zero/Extended Calibration

sensor configuration

1 LEL sensor detects combustible gases, 2 EC sensors detect toxic gases, 1 EC sensor detects oxygen, and 1 PID photoionization sensor detects VOCs

size

11.8×7.6×4.8 cm

weight

454g (including battery)


Sensor parameters of PGM-50 pump suction five gas detectors

gas type

Testing Scope

resolution

Response time (T90)

O2 oxygen

0-30%VOL

0.1%

15(S)

LEL combustible gas

0-100%LEL

1%

15(S)

CO Carbon Monoxide

0-500ppm

1ppm

25(S)

H2S hydrogen sulfide

0-100ppm

0.1ppm

30(S)

SO2, sulfur dioxide

0-20ppm

0.1ppm

35(S)

NO nitric oxide

0-250ppm

1ppm

30(S)

NO2 Nitrogen dioxide

0-20ppm

0.1ppm

25(S)

Cl2 chlorine gas

0-10ppm

0.1ppm

60(S)

HCN hydrogen green acid

0-100ppm

1ppm

60(S)

PH3 phosphine

0-5ppm

0.1ppm

60(S)

NH3 ammonia gas

0-50ppm

1ppm

60(S)

VOC organic gas

0-199ppm

0.1ppm

10(S)

VOC organic gas

200-1999ppm

1ppm

10(S)

PGM-50 Pump suction five gas detectors
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference