HomeYour location:Homeinstrumentation and metersPressure gaugepressure sensor → CJ9366 Pressure sensor
Column tabs 
Product name: CJ9366 Pressure sensor
specification: CJ9366 Pressure sensor
  Zoom Zoom in on the image
Category: instrumentation and meters -- pressure sensor
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


CJ9366 Pressure sensorDetailed product description:Column tabs
Characteristics of CJ9366 pressure sensor
Measurement range: 0~6KPa~2MPa
Silicon piezoresistive core HT20 is a sensitive component
High reliability, good stability, small size, lightweight structure
Full 316L stainless steel

Application of CJ9366 pressure sensor
Non corrosive gas and liquid pressure measurement for 316L stainless steel
process control system

Performance parameters of CJ9366 pressure sensor

measurement range

0~10KPa~2MPa

Zero position output

<2 mV

Full range output

DC100±20 mV

Positive overvoltage

2 times full scale

Negative terminal overvoltage

1x full scale or 1MPa (take the minimum value)

Static pressure

≤20MPa

accuracy

± 0.25% (typical) ± 0.5% (maximum)

long-term stability

± 0.3% F.S/year (typical) ± 0.5% F.S/year (maximum)

Pressure interface

M12 × 1 or user selectable

compensation temperature

0℃~70℃

Operating Temperature

-10℃~80℃

Storage temperature

-40℃~100℃

Shell material

Stainless steel 1Cr18Ni9Ti

Diaphragm material

316L

O-ring

fluororubber

cable

polyethylene

insulation resistance

100MΩ,100VDC

Shell protection level

IP65


Selection Tips
To ensure the safe and reliable operation of the sensor, it is recommended to install a three valve group between the measured point and the sensor to ensure that the measured medium is slowly and evenly added to the positive and negative pressure chambers of the differential pressure sensor.
It is recommended to install the small range differential pressure sensor horizontally.
When using, pay attention to whether the range and static pressure resistance of the differential pressure sensor meet the corresponding requirements of the measured differential pressure point.
It is strictly prohibited for the negative pressure chamber to be compressed higher than the positive pressure chamber.
CJ9366 Pressure sensor
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference