Main specifications of NES-150-24 single output switching power supply
DC output: 24V, 0~6.5A
AC input voltage range... selected by switch from 85-132VAC/170-264VAC
Input surge current... 45A at 230V cold start
DC output adjustment range... -5% to+10% of rated output voltage
Overload protection... The overcurrent point is between 110% and 150%, and it automatically detects and restores
Overvoltage protection... 115% to 135% of rated output voltage, automatic detection and recovery
Insulation characteristics: 3KVac between input and output, 1.5KVac between input and casing, 0.5KVac between output and casing, 1 minute
Working temperature: -20 to+60 ℃ (refer to temperature drop curve)
Seismic performance: 10-500Hz, 2G 10 minutes/cycle, XYZ axis 60 minutes each
Safety certification...... Passed UL60950-1, CB (IEC60950), TUV EN60950-1, CCC GB4943 certification
Shanghai Operations Control
Electromagnetic compatibility standard... emission: EN55022 (CISPR22) class B, GB9254 CLASS B, harmonics: EN61000-3-2,3
Anti interference: EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-1, A-level heavy industry standard
Mean time between failures... ≥ 433300 hours, MIL-HDBK-217F (25 ℃)
Wiring method: Both input and output are terminal blocks
Dimensions (L * W * H) mm 199 × 98 × 38
Case number: 902
Weight and packaging: 0.7 kilograms, 20 units/15 kilograms per box, 0.02 cubic meters