The microcomputer based universal tool microscope JX13b is a versatile measuring instrument widely used in mechanical manufacturing, electronic manufacturing, and metrology testing. It can be used to measure the size, shape, angle, and position of various parts within the measuring range. The instrument adopts computer technology to process measurement data, and can use various measurement methods such as imaging method, axial cutting method, contact method, and double beam interference fringe method, which greatly improves the measurement performance of the instrument. The composability and developability of software enhance the functionality of the system, which can meet the needs of users on a larger scale.
The typical measuring objects of JX13b microcomputer universal tool microscope include:
1. Measure the shape of various molded parts, such as templates, template cutting tools, template milling cutters, dies, and cams;
2. Measure the pitch, major diameter, minor diameter, pitch, and half angle of external threads such as threads, lead screws, and worm gears;
3. Measure the lead, tooth profile, and tooth angle of gear rolling cutters;
4. Measure the positional accuracy of holes on circuit boards, drill dies, or orifice plates, as well as the symmetry of key slots and other form and position errors.
Technical parameters of JX13b microcomputer universal tool microscope
1. Workbench
X-coordinate travel: 200mm
Y-axis travel: 100mm
X. Y-coordinate resolution: 0.0002mm
Measurement accuracy: (1+L/100) μ m, where L is the measurement length, unit: mm
Flat worktable size (mm): 260 × 270
Round worktable diameter: ф 213mm
Circular worktable angle division range: 0 °~360 °
Circular worktable angle division value: 30“
2. Main microscope column
Tilt range: ± 12 °
Tilt angle division value: 30 '
3. Angle measuring eyepiece
Angle division range: 360 °
Angle division value: 1 '
4. Contour eyepiece
Angle division range: ± 7 °
Angle division value: 10 '
5. Top needle device
Maximum clamping length between top pins: 700mm
Maximum diameter that can be accommodated between the top pins: ф 100mm
6. High top needle holder
Maximum clamping length of high top needle holder: 200mm
Maximum diameter that the high top needle holder can accommodate: ф 250mm
7. Circular dividing head
Dividing range of dividing head angle: 0 °~360 °
Dividing head angle division value: 1 '
8. Optical locator
Measurement range (mm): 5-200
Vertical swing range of measuring rod: ± 3 °
Minimum detection aperture: ф 5mm
Maximum detection depth: 15mm
Positioning variability:<1 μ m
Measurement force (N): 0.1 ± 0.03
9. Dimensions of the instrument host (mm): length x width x height=1300 x 1250 x 800
10. Instrument weight: 450kg
11. Environmental requirements: Indoor temperature of 20 ℃± 1 ℃, relative humidity less than 60%
12. Objective lens:
| Objective magnification |
Total magnification factor |
Working distance of the property |
| 1× |
10× |
82mm |
| 3× |
10× |
70mm |
| 5× |
10× |
49mm |