| Product name: | YXC series magnetic assisted electric contact pressure gauge | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- pressure gauge | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||

|
type |
model |
name (including full name or abbreviation) |
Scale range MPa |
Accuracy Grade |
threaded joint size | ||
|
instruction |
Setpoint | ||||||
|
connect |
disconnect | ||||||
|
Standard Type |
YXC-100 *YXC-102 YXC-103 |
Magnetic assisted electric contact pressure gauge |
From 0 to 60 and -0.1-0.06 to 2.4 series |
one point five |
one point five |
four |
M20×1.5 (*G3/8) (*G1/2") |
|
YXC-150 *YXC-153 |
0-0.1 to 60 and -0.1-0 to 2.4 series | ||||||
|
Specialized type |
YXCA-150 |
Magnetic assisted electric contact ammonia pressure gauge |
0-0.16 to 60 and -0.1-0.06 to 2.4 series |
two point five |
two point five |
four | |
|
Vibration-resistant |
YXC-100-Z *YXC-102-Z YXC-103-Z |
Magnetic assisted electric contact pressure gauge |
0-0.6 to 60 and -0.1-0.5 to 2.4 series |
one point five |
one point five |
five | |
|
Corrosion resistant type |
*YXC-100B-F *YXC-102B-F *YXC-103B-F *YXC-150B-F *YXC-152B-F |
0-0.16 to 60 and -0.1-0.06 to 2.4 series |
one point five |
one point five |
four | ||
|
Corrosion resistant and vibration resistant type |
*YXC-100B-FZ *YXC-102B-FZ *YXC-152B-FZ *YXC-153B-FZ |
0-0.6 to 60 and -0.1-0.5 to 2.4 series |
one point five |
one point five |
five | ||
|
Isolation type ordinary type Isolated corrosion-resistant type |
YXCG-103 *YXCG-103-F |
Isolated magnetic assisted contact pressure gauge |
0-0.16 to 60 and -0.1-0.06 to 2.4 series |
one point five |
one point five |
four |
M42×2 (*G1") |
|
Isolation type anti vibration type |
YXCG-103-Z |
0-0.6 to 60 and -0.1-0.5 to 2.4 series |
one point five |
one point five |
five | ||
|
Isolated corrosion-resistant and vibration resistant type |
*YXCG-103-FZ | ||||||
Note: 1) Models marked with "*" are temporarily limited to special orders
2) The isolated soft tail length is 1, 2, 3, and 4m (with 2m being the preferred length)
Electrical parameters and control forms of contact devices
|
Contact power |
Maximum operating voltage |
Maximum operating current |
control form |
|
30VA (resistive load) |
220V D.C or 380V A.C |
1A |
Upper and lower limits, dual upper limits, dual lower limits |
Note: When the current is 1A, the operating voltage should be lower than 40V.
Environmental conditions for use
|
type |
Working temperature range |
relative humidity |
Anti working vibration performance | |
|
medium |
surrounding environment | |||
|
Ordinary type, specialized type |
-40~70℃ |
Not exceeding 85% |
V. Level H.3 | |
|
Corrosion resistant type |
-25~55℃ |
Not exceeding 90% |
V. Level H.3 | |
|
Anti vibration type, corrosion-resistant and anti vibration type |
V. H.4 level | |||
|
Isolation type ordinary type |
Below 150 ℃ |
-40~70℃ |
V. Level H.3 | |
|
Isolated corrosion-resistant type |
-40~70℃ | |||
|
Isolation type other types |
Below 150 ℃ |
-25~55℃ |
V. H.4 level | |
Temperature effect: The displayed value should not exceed 0.4%/10 ℃, and the set point should not exceed 0.6%/10 ℃ (with a deviation of 20 ± 5 ℃ from the operating temperature)
□ Structural principle
The instrument consists of a measuring system, an indicating device, a magneto electric contact device, a housing, an adjusting device, and a junction box (plug socket).
The working principle of the instrument is based on the fact that the spring tube in the measurement system is forced to produce corresponding elastic deformation displacement at the end of the spring tube under the pressure of the measured medium. With the help of a pull rod and the transmission of the gear transmission mechanism, the measured value is amplified and gradually indicated on the dial by the indicator pointer (along with the contact) fixed on the gear shaft. At the same time, when it comes into contact with the contact point (upper or lower limit) on the set pointer (dynamic breaking or dynamic closing), it causes the circuit in the control system to be disconnected or connected, in order to achieve automatic control and send alarm signals.