KHJ1/24.5 Mining intrinsically safe emergency stop switchDetailed product description:

The KHJ1/24.5 intrinsically safe emergency stop switch for mining is suitable for hazardous areas with explosive gas mixtures, as well as workplaces such as open-pit coal mines and coal preparation plants. It is used as an emergency stop signal detection device for the comprehensive protection and control of mining belt conveyors, and can also be used for emergency stop of underground belt conveyors in coal mines in case of accidents.
Main parameters of KHJ1/24.5 intrinsically safe emergency stop switch for mining use
Contact capacity: DC24.5V/1A;
Output contact form: one pair of normally open and one pair of normally closed;
Action direction: bidirectional;
Action angle: 30 º ± 3 º;
The action force of the lever: (30-50) N;
Reset force: (10 ± 3) N;
Functional characteristics of KHJ1/24.5 intrinsically safe emergency stop switch for mining use
The emergency stop switch consists of a housing, a travel switch, a cam mechanism, a reset mechanism, a locking mechanism, wiring terminals, and other parts.
The emergency stop switch control panel drives the cam to rotate under the action force, and the travel switch outputs a control signal. The cam mechanism is locked and must be manually reset before unlocking.