| Product name: | HDGC3531 Power Quality Analyzer | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- power meter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
Project Name |
Measurable range |
Measurement accuracy |
explanation |
|
Voltage/current/frequency |
Three phase voltage: 10~700V (true RMS) |
Voltage: ± 0.5% Current: ± 0.5% Frequency: ± 0.01Hz |
Here, the A-phase voltage frequency is used as the measurement frequency |
|
Harmonic Measurement |
Voltage harmonics: total harmonics, 1st to 50th harmonics |
Voltage harmonics: ± 0.1 (% f) |
|
|
power measurement |
Active power: 0.05~700KW |
Merit: ± 2% |
|
|
three-phase unbalance |
Fundamental voltage: 10~700V (true RMS) |
Voltage: 0.5% |
Here, the A-phase voltage frequency is used as the total measurement frequency |
|
Project Name |
Measurable range |
Measurement accuracy |
explanation |
|
monitoring record |
Recorded parameters: three-phase voltage, three-phase current, neutral line current, voltage harmonics (total harmonics, 1-25th harmonics), current harmonics (total harmonics, 1-25th harmonics), three-phase imbalance, active power, power factor, fluctuation, flicker |
Recording duration=(the maximum number of big data that can be recorded by the instrument multiplied by the storage time interval)/60 minutes=18635 * 3 seconds/3600 seconds=15.5 hours |
The collection interval is set to 3 seconds, which can monitor for 15.5 hours. The collection interval can be set to 30 minutes, which can monitor for 388 days (continuously adjustable from 3 seconds to 30 minutes) |
|
Sudden rise and sudden drop |
Voltage surge, voltage dip, and temporary power outage |
Zui can record up to 40 events | |
|
Fluctuations |
Voltage fluctuation: 0.1%~10.0% |
Measurement error: ± 5% |
|
|
Flicker |
Short term flicker |
Short term flicker measurement error: ± 5% |
|
|
Digital Oscilloscope |
Instantaneous waveforms of three-phase voltage, three-phase current, zero line voltage, and zero line current |
Maximum sampling frequency: 200KHz |
|
|
model |
HDGC3531 | ||
|
display screen |
Touch screen, color graphic LCD | ||
|
communication interface |
USB | ||
|
weight |
1.0KG | ||
|
memory |
64M bit | ||