Product name: LCWB6-110(W2),LCWB6-110GYW2 series current transformers
specification: LCWB6-110(W2),LCWB6-110GYW2 series current transformers
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- 110KV current transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


LCWB6-110(W2),LCWB6-110GYW2 series current transformersDetailed product description:Column tabs
The LCWB6-110 (W2) and LCWB6-110GYW2 series current transformers are oil tank ceramic bushing capacitive insulated U-shaped structures. The primary coil adopts a traditional U-shaped structure, which has good free characteristics and thermal breakdown stability.
The capacitive structure has a relatively uniform voltage distribution due to the level adjustment effect.

Main technical data of LCWB6-110 (W2), LCWB6-110GYW2 series current transformers:

1. Rated primary current: 2 × 50, 2 × 75, 2 × 100, 2 × 150, 2 × 200, 2 × 300, 2 × 400, 2 × 500, 2 × 600 (2 × 300), 2 × 750 (2 × 400), or 2 × 1000 (2 × 500) A.
2. Rated secondary current: 5A or 1A.
3. Rated frequency: 50Hz.
4. Accuracy level combination: p/p/p0.5 level.
5. Rated output.
5.1 For rated currents of 2 × 50-2 × 1000/5A, the rated output for levels 0.5 and P is 50VA.
5.2 For rated currents of 2 × 50-2 × 1000/1A, the rated output for levels 0.5 and P is 30VA.
5.3 For rated currents of 2 × 600, 2 × 750, and 2 × 1000/5A, the rated output of the 0.5 level winding tap (corresponding current ratios of 2 × 300, 2 × 400, and 2 × 500/1A) is 20VA.
6. 0.5 level instrument security factor (Fs): Fs ≤ 20.
7. P-level 10% multiples are 15 times.
8. The rated 1-second thermal stability current level dynamic stability current shall not be less than the values specified in the table below.

LCWB6-110 (W2), LCWB6-110GYW2 series current transformer

Rated primary current (A)
50-100
75-150
100-200
150-300
200-400
300-600
Rated short-time thermal current (KA)
5.3-10.6
7.9-15.8
10.5-21
15.8-31.5
21-42
31.5-45
Dynamic stability current (KA)
13-26
20-40
27-54
40-80
54-108
80-115

Technical parameters and installation dimensions of LCWB6-110 (W2), LCWB6-110GYW2 series current transformers

LCWB6-110(W2),LCWB6-110GYW2 series current transformers
Product Category