| Product name: | HA series Hall switch | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- Hall switch | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
|
output format |
model |
wiring method |
|
DC NPN three wire normally open |
HA10-1K |
Refer to wiring diagram (1) |
|
DC NPN three wire normally closed |
HA10-1B | |
|
DC PNP three wire normally open |
HA10-2K |
Refer to wiring diagram (2) |
|
DC PNP three wire normally closed |
HA10-2B |
|
Installation type |
embedded |
|
Operating Voltage |
DC type: 3-28VDC |
|
interpolation value |
Not exceeding 20% of the detection distance |
|
detection distance |
10mm ± 20% (relative to the standard test sample of Φ 8 × 5)
The actual detection distance shall prevail, and the size of the detection distance mainly depends on the magnetic steel |
|
quiescent current |
≤5mA |
|
Control current output |
Resistive load 100mA, inductive load 50mA |
|
Response frequency |
5000Hz |
|
Protection level |
IP66 (IEC specification) |
|
residual voltage |
DC three wire type: ≤ 1.5VDC |
|
temperature effect |
The detection distance at+25 ℃ is below 20% within the range of -25 ℃ to+70 ℃ |
|
insulation resistance |
≥ 50M Ω Min (500VDC Mega reference) |
|
pressure resistance |
1500VAC 50/60Hz per minute |
|
Anti vibration |
Anti vibration: 10-55Hz (period per minute) with a complex amplitude of 1mm, 2 hours in each direction of X, Y, and Z |
|
impact-resistant |
Impact resistance: 500M/S2 (50G), 3 times in X, Y, Z directions |
|
Ambient temperature |
Working hours: -30 to+80 ℃ (in unfrozen state) |
|
When stored: -30 to+80 ℃ in an unfrozen state) | |
|
Ambient Humidity |
Working hours: 35 to 95% RH |
|
indicator light |
Action display (red LED) |