HomeYour location:Hometransformer equipmentIsolation transformer → SG series three-phase dry-type isolation transformer
Column tabs 
Product name: SG series three-phase dry-type isolation transformer
specification: SG series three-phase dry-type isolation transformer
  Zoom Zoom in on the image
Category: transformer equipment -- Isolation transformer
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


SG series three-phase dry-type isolation transformerDetailed product description:Column tabs
I. Overview
The SG series dry-type isolation transformer converts alternating current energy of one voltage and current phase into another voltage and current phase through electromagnetic coupling to meet the voltage and current phase requirements of the equipment. According to the usage environment and cooling method, it can be divided into two types: dry-type transformers and oil immersed transformers.

2、 Model meaning

SG series dry-type transformer model specifications and main parameters

DG, SG series dry-type isolation transformer model description

Model Rated capacity
(KVA)
input voltage
(V)
output voltage
(V)
connection method frequency
(He)
SG-10/0.5 ten three hundred and eighty According to user requirements Y/Y0-12 50/60
SG-20/0.5 twenty three hundred and eighty According to user requirements Y/Y0-12 50/60
SG-30/0.5 thirty three hundred and eighty According to user requirements Y/Y0-12 50/60
SG-40/0.5 forty three hundred and eighty According to user requirements Y/Y0-12 50/60
SG-50/0.5 fifty three hundred and eighty According to user requirements △/Y0-11 50/60
SG-63/0.5 sixty-three three hundred and eighty According to user requirements △/Y0-11 50/60
SG-80/0.5 eighty three hundred and eighty According to user requirements △/Y0-11 50/60
SG-100/0.5 one hundred three hundred and eighty According to user requirements △/Y0-11 50/60
SG-125/0.5 one hundred and twenty-five three hundred and eighty According to user requirements △/Y0-11 50/60
SG-160/0.5 one hundred and sixty three hundred and eighty According to user requirements △/Y0-11 50/60
SG-200/0.5 two hundred three hundred and eighty According to user requirements △/Y0-11 50/60
SG-250/0.5 two hundred and fifty three hundred and eighty According to user requirements △/Y0-11 50/60
SG-315/0.5 three hundred and fifteen three hundred and eighty According to user requirements △/Y0-11 50/60
SG-400/0.5 four hundred three hundred and eighty According to user requirements △/Y0-11 50/60
SG-500/0.5 five hundred three hundred and eighty According to user requirements △/Y0-11 50/60

Model (KVA)

Overall dimensions
Length x Width x Height (cm)

Installation size (cm)

housing dimensions
Length x Width x Height (cm)

Transformer weight (kg)

SG-10

42×21×42

135×310

70×35×77

ninety

SG-20

52×24×52

155×400

70×35×77

one hundred and eighty

SG-30

55×28×65

165×400

80×40×87

two hundred and twenty

SG-40

61×30×65

170×400

80×40×87

two hundred and sixty-five

SG-50

61×30×65

175×400

100×50×104.5

two hundred and ninety-six

SG-60

70×32×66

190×450

100×50×104.5

three hundred and seventy

SG-70

70×32×66

190×450

100×50×104.5

four hundred

SG-80

70×35×67

195×450

100×50×104.5

four hundred and fifty

SG-100

75×35×68

210×450

100×50×104.5

four hundred and ninety

SG-120

75×35×68

215×450

100×50×104.5

five hundred and twenty

SG-150

85×37×68

230×450

120×65×114.5

six hundred and fifty

SG-200

95×45×68

290×450

120×65×114.5

eight hundred and fifty

SG-250

95×45×83

290×450

120×70×124.5

one thousand and eighty

SG-300

105×45×95

290×450

120×70×124.5

one thousand three hundred and fifty


Outline dimensions of SG series three-phase dry-type isolation transformer

SG series three-phase dry-type isolation transformer
Product Category