HomeYour location:HomePump valve fittingsPump productscirculation pump → RH and RHX circulating hot water pumps
Column tabs 
Product name: RH and RHX circulating hot water pumps
specification: RH and RHX circulating hot water pumps
  Zoom Zoom in on the image
Category: Pump valve fittings -- circulation pump
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916950330

Email 91way@163.com
Wechat 13916950330(Wechat)


RH and RHX circulating hot water pumpsDetailed product description:Column tabs
RH and RHX pumps are energy-saving products that have been updated and modified from R-type pumps. Its structural form and installation dimensions are exactly the same, but it has higher hydraulic efficiency and better cavitation performance.
RH and RHX hot water circulation pumps are suitable for conveying high-pressure hot water without particles below 180 ℃ or 207 ℃ in metallurgy, power plants, plastics, rubber, textile, chemical, wood and paper industries. The material of the overcurrent part of the pump is ductile iron, which is not corrosion-resistant.
Performance range of RH and RHX hot water circulation pumps (according to design points)
Flow rate: 7.2-450m3/h Head: 20-65m Inlet diameter: 40-350mm

The RH and RHX type hot water circulation pump is a single-stage single suction horizontal centrifugal pump, with the pump body as the center support, the inlet of the pump in the horizontal axis direction, and the outlet of the pump in the vertical upward direction. The impeller is fixed on the shaft with nuts, and the pump shaft is supported in the bearing bracket with a pair of single row radial thrust ball bearings and a single row radial ball bearing (or a single row radial cylindrical roller bearing). The pump body is connected to the bearing bracket with bolts, and the pump shaft is connected to the motor through an elastic pin coupling. The pump and motor are both installed on a base that matches the model.  
The sealing structure of the RH pump adopts a floating ring seal. The sealing structure of RHX pump adopts mechanical seal.

Model Description of RH and RHX Circulating Hot Water Pumps

Performance Table of RH and RHX Pumps

model
Traffic Q
Head H
(m)
Speed n
(r/min)
Power P (Kw)
Efficiency η
(%)
Necessary cavitation allowance
(NPSH)r(m)
Weight W (Kg)
(m3/h)
(L/S)
shaft power
Equipped with power
pump
base
40RHX-26
40RH-26
nine point zero four
two point five
twenty-five point five
two thousand nine hundred and sixty
one point one six
two point two
fifty-four
one point five
ninety-two
sixty-nine
50RHX-40
50RH-40
seventeen point seven six
four point nine three
forty
two thousand nine hundred and sixty
three point five one
five point five
fifty-five
one point six
one hundred and twenty-three
one hundred and fifty-five
65RHX-40
65RH-40
thirty point six
eight point five
thirty-nine point five
two thousand nine hundred and sixty
five point two two
seven point five
sixty-three
two
one hundred and fifty-eight
one hundred and sixty-eight
65RHX-64
65RH-64
thirty-four point one
nine point four seven
sixty-four
two thousand nine hundred and sixty
nine point nine
fifteen
sixty
two point four
one hundred and seventy-six
two hundred and five
80RHX-60
80RH-60
fifty-one point one three
fourteen point two
sixty
two thousand nine hundred and sixty
twelve point four six
eighteen point five
sixty-seven
two point five
two hundred and twenty-six
one hundred and seventy
100RHX-37
100RH-37
one hundred and one point four
twenty-eight point one seven
thirty-six point five
two thousand nine hundred and sixty
twelve point seven six
eighteen point five
seventy-nine
three point five
one hundred and seventy
two hundred and five
100RHX-57
100RH-57
one hundred and seven point one
twenty-nine point seven five
fifty-seven
two thousand nine hundred and sixty
twenty-one point five nine
thirty
seventy-seven
three point five
two hundred and twenty-four
two hundred and thirty
150RHX-35
1500RH-35
one hundred and ninety-two point three
fifty-three point four
thirty-four point seven
one thousand four hundred and eighty
twenty-two point seven two
thirty
eighty
two point two
four hundred and forty-eight
two hundred and fifty
150RHX-56
150RH-56
one hundred and ninety point eight
fifty-three
fifty-five point five
one thousand four hundred and eighty
thirty-eight point nine seven
fifty-five
seventy-four
two point two
six hundred and twenty-seven
four hundred and three
200RHX-45
200RH-45
two hundred and eighty-three point nine
seventy-eight point eight six
forty-five
one thousand four hundred and eighty
forty-two point four three
fifty-five
eighty-two
three
seven hundred and fifteen
four hundred and ten
200RHX-72
200RH-72
two hundred and eighty-four point three
seventy-eight point nine seven
seventy-two
one thousand four hundred and eighty
seventy-four point three three
ninety
seventy-five
three
one thousand and thirty-one
two hundred and seventy
250RHX-62
25RH-62
four hundred and fifty-nine
one hundred and twenty-seven point five
sixty-two
one thousand four hundred and eighty
ninety-four point five
one hundred and fifteen
eighty-two
three point five
nine hundred and forty-six
three hundred and twenty-four
350RH-65
one thousand two hundred and ninety-one
three hundred and fifty-eight point six
sixty-two point eight
one thousand four hundred and eighty
two hundred and sixty-two point eight five
three hundred and sixty
eighty-four
six
one thousand one hundred and seventy
six hundred and eighty-two

Note: 1. The performance parameters listed in the table are all tested with room temperature clean water r=1 as the test medium.

RH and RHX circulating hot water pumps
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference