| Product name: | N,NL,NB type condensate pump | ||||||
| specification: | ![]() |
||||||
| Category: | Pump valve fittings -- feed pump | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||

|
model |
Traffic |
head (m) |
rotation speed (r/min) |
power |
efficiency % |
impeller diameter D (millimeters) |
High perfusion head degree (meters) | ||
|
m3/h |
(l/s) |
shaft power |
electric motor | ||||||
|
100NB-45 |
fourteen point four twenty-four thirty-one |
four six point six seven eight point six two |
fifty-four fifty forty-two |
three thousand nine hundred and fifty |
four point eight six point two seven |
Y132S2-2 7.5KW |
forty-four fifty-four fifty-two |
one hundred and ninety-six |
one one one point one |
|
100NB-60 |
twenty-one point six thirty-six fifty point four |
six ten fourteen |
sixty-nine sixty-two forty-four |
two thousand nine hundred and fifty |
nine eleven point five fourteen |
Y160M2-2 15KW |
forty-five fifty-three forty-three |
two hundred and twenty-nine |
one one point one one point two |
|
6NB-6 |
sixty-five ninety-five one hundred and four |
eighteen twenty-six point four twenty-nine |
ninety eighty-eight eighty-six |
two thousand nine hundred and thirty |
twenty-nine point four thirty-five point six thirty-seven |
Y200L2-2 37KW |
fifty-four sixty-four sixty-six |
two hundred and fifty-five |
one one point two one point three |
|
6NB-6A |
sixty-eight eighty-five one hundred and two |
eighteen point nine twenty-three point six twenty-eight point four |
seventy-three seventy-two sixty-nine |
two thousand nine hundred and thirty |
twenty-three point three twenty-six point four twenty-nine |
Y200L1-2 30KW |
fifty-eight sixty-three sixty-six |
two hundred and twenty-eight |
one point two one one point two |
|
8NB-12 |
one hundred and forty-four one hundred and eighty two hundred and sixteen |
forty fifty sixty |
sixty-four sixty fifty-five |
two thousand nine hundred and thirty |
thirty-seven forty forty-three |
Y225W-2 45KW |
sixty-eight seventy-four seventy-five |
two hundred and thirty |
one point six one point eight two point three |
|
*8NL-60 |
one hundred and forty-four one hundred and eighty two hundred and sixteen |
forty fifty sixty |
sixty-four sixty fifty-five |
two thousand nine hundred and thirty |
thirty-seven forty forty-three |
Y255M-2(B5、V1)45KW Y |
sixty-eight seventy-four seventy-five |
two hundred and thirty |
one point six one point eight two point three |
|
8NL-130 |
one hundred and twenty one hundred and sixty two hundred and sixteen |
thirty-three forty-five sixty |
one hundred and forty-three one hundred and thirty-five one hundred and eighteen |
two thousand nine hundred and seventy-five |
eighty ninety-one point five one hundred and seven |
315S-2 (B5、V1)110KW |
fifty-six sixty-five seventy-two |
three hundred and twenty |
one point eight one point five three |
|
12NL-125 |
two hundred and sixty-two three hundred and twenty three hundred and ninety-six |
seventy eighty-nine one hundred and ten |
one hundred and thirty-six one hundred and twenty-five one hundred and thirteen |
one thousand four hundred and seventy-five |
one hundred and thirty-five one hundred and fifty-two one hundred and seventy-two |
JSL11-4 180KW 380V |
seventy-one seventy-five seventy-three |
First 450 460 times |
one point three one point five one point eight |
|
12NL-160 |
three hundred and fifty-five |
ninety-eight point six |
one hundred and fifty-eight |
one thousand four hundred and seventy-five |
two hundred and six point four |
JSL12-4 225KW 380V |
seventy-four |
First 352 Number 345 |
one point nine |
|
16NL-45 |
five hundred and fifty |
one hundred and fifty-three |
forty-five |
one thousand four hundred and seventy-five |
ninety-six point five |
JSL11-4 115KW 380V |
seventy-five |
four hundred and twenty-two |
two |
|
16NL-75 |
five hundred and fifty |
one hundred and fifty-three |
seventy-five |
one thousand four hundred and seventy-five |
JSL11-4 180KW 380V |
seventy-two |
First 416 Number 306 |
three point five | |
|
16NL-160 |
five hundred and fifty |
one hundred and fifty-three |
one hundred and sixty |
one thousand four hundred and seventy-five |
JSL360 360KW 6KV |
seventy-four |
First 402 390 times |
five | |
|
16NL-180 |
four hundred and thirty-two five hundred and fifty five hundred and ninety-four |
one hundred and twenty one hundred and fifty-three one hundred and sixty-five |
one hundred and ninety-four point five one hundred and eighty one hundred and seventy-three point five |
one thousand four hundred and fifty |
three hundred and seventeen point eight three hundred and forty-six point two three hundred and fifty-three |
JSL430KW4P 6KV |
seventy-two seventy-eight seventy-nine point five |
First 416 406 times |
two point five two two point five |
|
18NL-84 |
eight hundred and ten |
two hundred and twenty-five |
eighty-four |
one thousand four hundred and seventy-five |
two hundred and thirty-two |
JSL-13-4 300KW |
eighty |
First 430 420 times |
two point five three |
|
18NL-100 |
six hundred and thirty seven hundred and twenty nine hundred |
one hundred and seventy-five two hundred two hundred and fifty |
one hundred and four one hundred eighty-five |
one thousand four hundred and fifty |
two hundred and forty-five two hundred and forty-five two hundred and forty-six |
JSL360KW4P 6KV |
seventy-three eighty eighty-five |
First 440 430 times |
two point five two point five three point two |
|
18NL-190 |
six hundred and thirty seven hundred and twenty nine hundred |
one hundred and seventy-five two hundred two hundred and fifty |
one hundred and ninety-nine one hundred and ninety one hundred and sixty |
one thousand four hundred and fifty |
four hundred and fifty four hundred and sixty-five five hundred and two |
JSL550KW4P 6KV |
seventy-six eighty seventy-eight |
four hundred and thirty |
four point seven five point three six point five |
|
18NL-260 |
eight hundred and sixty |
two hundred and thirty-nine |
two hundred and sixty |
one thousand four hundred and seventy-five |
seven hundred and sixty-one |
Y-shaped vertical 900KW |
eighty |
First 440 430 times |
three |
|
12NS-175 |
eight hundred and ten |
two hundred and twenty-five |
one hundred and seventy-five |
two thousand nine hundred and fifty |
four hundred and eighty-three |
JS-630 630KW 6KV |
eighty |
three hundred and seventy-five |
ten point five |
|
48NL-32 |
eleven thousand thirteen thousand and two hundred |
three thousand and fifty-five point six three thousand six hundred and sixty-six point seven |
thirty-two twenty-eight |
four hundred and ninety-five |
one thousand and ninety one thousand one hundred and seventy-two |
YL1250-12 1250KW 6KV |
eighty-six eighty-four |
one thousand and fifty |
three point two three point five |