HomeYour location:Homeinstrumentation and metersElectrical instrumentsclamp meter → 2009A AC/DC clamp meter
Column tabs 
Product name: 2009A AC/DC clamp meter
specification: 2009A AC/DC clamp meter
  Zoom Zoom in on the image
Category: instrumentation and meters -- clamp meter
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13901609058

Email 91way@163.com
Wechat 13901609058(Wechat)


2009A AC/DC clamp meterDetailed product description:Column tabs
2009A type AC/DC clamp meter:

It is an ideal measuring instrument that can read the true root mean square value of the abnormal waves and non sinusoidal waves generated by the gate fluid
AC/DC current can be measured up to 2000A
The output terminal can be connected to an oscilloscope

AC/DC clamp table 2009A Other instructions:

model Model 2009A
alternating current 400A(0|400A)(True|RMS)
±1.5%rdg±3dgt(50/60Hz)
±3%rdg±4dgt(30|1kHz)
2000A(0|1700A)(True|RMS)
±1.5%rdg±2dgt(50/60Hz)
±3%rdg±4dgt(30|1kHz)
2000A(1701|2000A)(True|RMS)
±3rdg±3dgt(50/60Hz)
AC voltage 40/400/750V(True|RMS)
±1.5%rdg±3dgt(50/60Hz)
±1.5%rdg±4dgt(40|1kHz)
direct current 400/2000A
±1.5%rdg±2dgt
DC voltage 40/400/1000V
±1%rdg±2dgt
resistance 400/4000 Ω
±1%rdg±2dgt
Continuous buzzing buzzer sounds below 20Ω
frequency 10|4000Hz
±1.5%rdg±5dgt
output voltage 400/2000A
DC400mV/200mV
Conductor size Φ55mm max
safety standards IEC61010|1CAT. Ⅲ600V CAT.Ⅱ1000V
IEC61010|2|031,IEC61010|2|032
frequency response 40Hz|1kHz
pressure resistance 5550V AC for 1 minute
power supply 6F22(9V)×1
volume 250(L)×105(W)×49(D)mm
weight 540g
Attachment 7107820190946F22 (9V) × 1 instruction manual
Optional parts 8008(AC only)
seven thousand and fourteen