HomeYour location:HomePump valve fittingsvalve productscontrol valve → GJ41X-6L type pipe clamp valve
Column tabs 
Product name: GJ41X-6L type pipe clamp valve
specification: GJ41X-6L type pipe clamp valve
  Zoom Zoom in on the image
Category: Pump valve fittings -- control valve
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916950330

Email 91way@163.com
Wechat 13916950330(Wechat)


GJ41X-6L type pipe clamp valveDetailed product description:Column tabs

Structure and Working Principle of GJ41X-6L Pipe Clamp Valve
(1) Structure: The GJ41X-6L pipe clamp valve consists of left and right valve bodies, rubber pipe sleeves, large and small valve stems, upper and lower gate plates, guide columns, and other components.
(2) Working principle: When the steering wheel is turned in sequence, the large and small valve stems simultaneously drive the upper and lower gate plates, compress the pipe sleeve, and close them. When reversed, they open them. In this way, the gate plates reciprocate up and down between the guide columns to complete the valve opening and closing work. In addition, due to the load-bearing capacity of the rubber sleeve, when the operator rotates the handwheel during the switch, as long as they feel an appropriate amount of resistance, they have already reached the opening and closing pole. Do not try their best or have multiple people assist, and do not use other tools for opening and closing.  

Structural diagram of GJ41X-6L type pipe clamp valve

GJ41X-6L type pipe clamp valve external dimensions

Main connection dimensions and external dimensions of GJ41X-6L pipe clamp valve

Nominal Diameter
Main outline dimensions and connection dimensions of GJ41X-6L pipe clamp valve
Weight (KG)
L
D
D1
D2
b
Z-?
twenty
one hundred and thirty-five
one hundred and five
seventy-five
fifty-five
sixteen
4-14
two point five
twenty-five
one hundred and forty-five
one hundred and fifteen
eighty-five
sixty-five
sixteen
4-14
three
thirty-two
one hundred and sixty
one hundred and thirty-five
one hundred
seventy-eight
eighteen
4-18
four
forty
one hundred and eighty
one hundred and forty-five
one hundred and ten
eighty-five
eighteen
4-18
six
fifty
two hundred and ten
one hundred and sixty-five
one hundred and twenty-five
one hundred
twenty
4-18
seven point five
sixty-five
two hundred and fifty
one hundred and eighty-five
one hundred and forty-five
one hundred and twenty
twenty
4-18
nine point five
eighty
three hundred
one hundred and ninety
one hundred and sixty
one hundred and thirty-five
twenty-two
4-18
sixteen
one hundred
three hundred and fifty
two hundred and fifteen
one hundred and eighty
one hundred and fifty-five
twenty-two
8-18
twenty
one hundred and twenty-five
four hundred and thirty
two hundred and forty-five
two hundred and ten
one hundred and eighty-five
twenty-five
8-18
twenty-eight
one hundred and fifty
five hundred
two hundred and eighty
two hundred and forty
two hundred and ten
twenty-five
8-23
forty-three
two hundred
six hundred and fifty
three hundred and thirty-five
two hundred and ninety-five
two hundred and sixty-five
thirty-two
8-23
eighty

Overview of clamp valves for electrolytic cells
The pipe clamp valve for electrolytic cells is made of special engineering plastics, with small volume and light weight. The valve body and all accessories have strong corrosion resistance. The valve is suitable for normal operation in environments that are corroded by acid both inside and outside. Eliminating internal and external leakage, facilitating tank cleaning work, practice has proven that it replaces stainless steel clamps and ends the history of using ball valves, plug valves or other valves. Its structure and working principle are the same as the pipe clamp valve.  

Installation and maintenance of clamp valves for electrolytic cells
(1) Insert the plastic pipe extending from the ground below the electric contact groove into one end of the rubber hose of the small valve, and insert the plastic pipe supplied by our factory into the other end. The outlet extends towards the electric contact groove and then tighten the two ends with copper wire or stainless steel clamps.
(2) After long-term use, if there is wear or leakage, simply open the left and right valve bodies and replace the pipe sleeves, and the valve can be used for a long time.

Nominal Diameter
Main connection dimensions of clamp valves for electrolytic cells
Weight
L1
L2
thirty-two
one hundred and forty-five
two hundred and twenty
five hundred and fifty
Fitting bend pipe
Use size according to user requirements
one hundred and sixty
forty
one hundred and forty-five
two hundred and forty
six hundred and fifty
Fitting bend pipe
Use size according to user requirements
two hundred

GJ41X-6L type pipe clamp valve
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference