HomeYour location:Hometransformer equipmentpower supply equipmentPrecision power supply → XF1a Type Three phase AC Instrument Calibration Device
Column tabs 
Product name: XF1a Type Three phase AC Instrument Calibration Device
specification: XF1a Type Three phase AC Instrument Calibration Device
  Zoom Zoom in on the image
Category: transformer equipment -- Precision power supply
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


XF1a Type Three phase AC Instrument Calibration DeviceDetailed product description:Column tabs
Compared with similar products, the XF1a three-phase AC instrument calibration device has higher waveform output stability and smaller distortion.
Fast output, accurate and reliable protection against voltage short circuits and current open circuits.
Single phase output power is high, with each phase outputting up to 30W.
More powerful harmonic output capability, capable of generating 2-31 harmonics, with a maximum harmonic amplitude of up to 50%.
The unique integrated design of the table source is both a standard source and a standard table. When the source is closed, it automatically switches to the standard table state, and you can use it as a standard table. The table source switch is fully automatic. At the same time, it can also measure the input of the clamp gauge.
The three-phase voltage and current phase can be set or adjusted arbitrarily.
High quality 6.5-inch true color LCD screen, wide temperature range, wide field of view, high brightness, can be used indoors or outdoors clearly and clearly.

Technical specifications of XF1a three-phase AC instrument calibration device
2.1 Output Parameters
2.1.1 AC voltage output:
Gear: 57.7V, 100V, 220V, 380V (can be customized according to user needs)
Adjustment range: 0-120% RG
Adjustment fineness: 0.01% RG
Stability: 0.005% (1 minute)
Distortion:<0.1%
Accuracy: 0.05% RG
Output capacity: Type A 20VA, Type B 30VA, Type C 50W
2.1.2 AC current output:
Gear: 1A, 2A, 5A, 20A (can be customized according to user needs)
Adjustment range: 0-120% RG
Adjustment fineness: 0.01% RG
Stability: 0.005% (1 minute)
Distortion:<0.1%
Accuracy: 0.05% RG
Output capacity: Type A 20VA, Type B 30VA, Type C 50W
2.1.3 Output frequency:
Adjustment range: 45Hz -70Hz
Adjust fineness: 0.001Hz
Accuracy: 0.005Hz
2.1.4 Output Phase:
Adjustment range: 0-360 degrees
Adjust fineness: 0.01 degrees
Accuracy: 0.05 degrees
2.1.5 Harmonic output:
Frequency: 2-31 times (can be increased up to 64 times according to user needs)
Amplitude: Type A: 0-38% (total harmonic<38%) (relative to the fundamental wave)
Type B: 0-50% (total harmonic<50%) (relative to the fundamental wave)
Accuracy: 0.5% RG
2.1.6 AC voltage measurement:
Gear: 57.7V, 100V, 220V, 380V for self source output measurement
When used as a standard table, 100V, 380V
Accuracy: 0.05% RG
Resolution: 0.001V
2.1.7 AC current measurement:
Gear: 1A, 2A, 5A, 20A for self source output measurement
When used as a standard table, 5A, 20A
Accuracy: 0.05% RG
2.1.8 Frequency measurement:
Measurement range: 45Hz-70Hz for self source output measurement
When used as a standard meter, 45Hz -68Hz
Resolution: 0.001Hz
Accuracy: 0.005Hz
2.1.9 Phase measurement:
Resolution: 0.001 degrees
Accuracy: 0.05 degrees
2.1.10 Active power:
Accuracy: 0.05%
2.1.11 Reactive power
Accuracy: 0.1%
2.2 External interface:
RS232/RS485
2.3 Environmental conditions:
Power supply: AC220V ± 15%
Environmental temperature: 25 ℃± 2 ℃
Working temperature: 0-40 ℃
Relative humidity:<85% without condensation
2.4 Volume: 420mm X 440mm X 156mm
XF1a Type Three phase AC Instrument Calibration Device
Product Category