| Product name: | 3321A/3322A/3323A Insulation resistance meter | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- ohmmeter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
Detailed information
Automatic discharge function, which automatically releases the charge from the charged voltage after testing.
Scale lighting that can be operated in dim places.
Standard material equipment for probes with remote control switches.
The shoulder strap allows for manual work.
Different color voltage ranges for easy reading.
Designed to comply with international safety standards IEC/EN 61010-1 CAT. III 600V
|
MODEL3321A |
MODEL3322A |
MODEL3323A | ||||||||
|
Insulation resistance meter |
Rated measured voltage |
250V |
500V |
1000V |
125V |
250V |
500V |
25V |
50V |
100V |
|
Effective maximum display value |
50MΩ |
100MΩ |
2000MΩ |
20MΩ |
50MΩ |
100MΩ |
10MΩ |
10MΩ |
20MΩ | |
|
median |
1MΩ |
2MΩ |
50MΩ |
0.5MG |
1MΩ |
2MΩ |
0.2MΩ |
0.2MΩ |
0.5MΩ | |
|
The first effective measurement scope |
0.05MΩ ~20MΩ |
0.1MΩ ~50MΩ |
2MΩ ~1000MΩ |
0.02MΩ ~10MΩ |
0.05MΩ ~20MΩ |
0.1MΩ ~50MΩ |
0.01MΩ ~5MΩ |
0.01MΩ ~5MΩ |
0.02MΩ ~10MΩ | |
|
(* 1) Standard state accuracy |
± 5% of the displayed value | |||||||||
|
The second effective measurement scope |
Scales other than the first effective measurement range of 0 and ∞ scales | |||||||||
|
(* 1) Standard state accuracy |
10% of the displayed value | |||||||||
|
The 0 and ∞ scales |
Below 0.7% of the scale | |||||||||
|
Open circuit voltage |
Less than 1.2 times the rated measured voltage value | |||||||||
|
Rated measured current |
When connecting a test resistor with a rated measured voltage of 1000 Ω, the range should be within 1mA0~+20% | |||||||||
|
short-circuit current |
Within 1.5mA DC | |||||||||
|
voltmeter |
Measurement range |
AC0-600V | ||||||||
|
accuracy |
± 3% of the maximum scale value | |||||||||
|
Safety specifications |
IEC61010-1 CAT.III 600V dustproof and waterproof IP40 | |||||||||
|
Withstand Voltage |
AC5550V/1 minute | |||||||||
|
use batteries |
Single 3 dry battery R6P (1.5V) × 6 | |||||||||
|
Overall dimensions |
105(L)×158(W)×70(D)mm | |||||||||
|
weight |
Approximately 520g (including battery) | |||||||||
|
(* 2) Testeable times for each range of test resistance |
2000 times above |
1000 times above |
300 times above |
2500 times above |
2000 times above |
1000 times above |
4000 times above |
3500 times above |
3000 times above | |
|
0.25MΩ |
0.5MΩ |
1MΩ |
0.125MΩ |
0.25MΩ |
0.5MΩ |
0.025MΩ |
0.05MΩ |
0.1MΩ | ||
|
Attachment |
7150 (Remote Switch Test Probe Combination) Single 3 Dry Battery R6P Shoulder Strap User Manual | |||||||||
|
Optional parts |
7115 (high-altitude measurement probe combination) 8016 (hook shaped metal head) 9089 (portable outer box for storing test lines) | |||||||||