JLS-40.5W High voltage power metering boxDetailed product description:Column tabs
The JLS-40.5 three-phase oil immersed outdoor high-voltage power metering box is composed of two voltage transformers and two current transformers combined and installed in one oil tank. Suitable for measuring active and reactive energy on a three-phase AC network with a rated voltage of 40.5KV and a rated frequency of 50Hz.

Main technical parameters of JLS-40.5W high-voltage power metering box

1. Rated primary voltage: 35000 (V)
2. Rated secondary voltage: 100 (V)
3. Rated primary current:
a、 Single variable ratio specifications include: 5, 10, 15, 20, 25, 30, 40

50, 60, 75, 100, 150, 200
b, Dual ratio specifications include: 5-10, 10-15, 15-25, 15-30, 20-40, 25-50, 50-70, 50-100, 75-150, 100-200
4. Rated secondary current: 5 (A)
5. Rated output and accuracy level: The current transformer is at 10VA 0.2S level or 0.2S level, and the voltage transformer is at 25VA 0.2 level
6. Power frequency withstand voltage: The primary to secondary and ground short-time power frequency withstand voltage is 95KV, and the secondary to ground short-time power frequency withstand voltage is 3KV
7. Rated short-time thermal current: 90 times the rated primary current
8. Rated dynamic stability current: 2.5 times the rated short-time thermal current

Error and temperature rise of voltage and current transformers inside the measuring box
The JLS-40.5W high-voltage power metering box meets the requirements of GB1207-97 and GB1208-97

Voltage Transformer Error Limit

accuracy level

Voltage error ±%
(At the following rated voltage percentages)

Phase difference ±%
(At the following rated voltage percentages)

eighty

one hundred

one hundred and twenty

eighty

one hundred

one hundred and twenty

zero point five

zero point five

zero point five

zero point five

twenty

twenty

twenty

zero point two

zero point five

zero point two

zero point two

ten

ten

ten


Error limit of current transformer

accuracy level

Voltage error ±%
(At the following rated voltage percentages)

Phase difference ±%
(At the following rated voltage percentages)

five

twenty

one hundred

one hundred and twenty

five

twenty

one hundred

one hundred and twenty

zero point five

one point five

zero point seven five

zero point five

zero point five

ninety

forty-five

thirty

thirty

zero point two

zero point seven five

zero point three five

zero point two

zero point two

thirty

fifteen

ten

ten


JLS-40.5W high-voltage power metering box temperature rise limit (referring to the temperature rise at maximum capacity)

Mutual inductance location

Temperature rise 0C

measurement method

coil

fifty-five

Resistance method

Coil head or connection sign

fifty

Thermometer method

oil noodles

fifty

Thermometer method


JLS-40.5W high-voltage power metering box

JLS-40.5W High voltage power metering box