| Product name: | 3286-20 clamp type power meter | ||||||
| specification: | ![]() |
||||||
| Category: | instrumentation and meters -- power meter | ||||||
| Price: | factory price | ||||||
| Brand: | Shanghai | ||||||
| Place of Origin: | China | ||||||
| Available Quantity: | batch | ||||||
| delivery cycle: | Spot goods (or inquire by telephone) | ||||||
|
|||||||
The 3286-20 clamp type power meter has powerful functions! Easy to operate! True effective value clamp power meter
Measurable single-phase power and power factor (30kW~600kW)
It is very convenient to measure three-phase power (60kW~1200kW)
Can monitor power fluctuations
1000A,1000Hz, Peak and harmonic can be measured
True effective value display
External printer (9442 printer)
Basic parameters of 3286-20 clamp type power meter
| measurement project | Voltage, current, peak voltage/current, active/reactive/apparent power (single-phase or 3-phase), power factor, no power, phase angle, frequency, Phase (3 phases), voltage/current harmonic order (up to 20 times) |
| Measure the diameter of the jaws | Maximum diameter of 55mm |
| display | LCD, Number (6000 points) |
| Adjustment method | RMS (True RMS) |
| Display update rate | Approximately once per second for NORMAL, once per three seconds for SLOW, and once per two seconds for HARM |
| Simulate response time | 4 seconds or less (input changes between 0% and 90% of the range) |
| Phase detection | Positive/Negative/Open Phase (3-phase balanced load) |
| record | Maximum and minimum values (active voltage, current, and active/apparent power functions) |
| battery capacity | Display as% when power is turned on |
| data retention | Keep displaying |
| Automatically turn off the power | About 10 minutes, the buzzer will sound before the power is turned off, which can be extended or cancelled |
| data output | RS-232C interface outputs through optical isolation coupler |
| Measurement range | AC voltage: 150.0 V~600 V, 3-speed range, AC current: 20.00~1000 A, 3-speed range, power: 3.000 kW~1200 kW, 18 combination modes Note: The calculation and display of 3-phase power are based on a balanced 50/60Hz sine wave input. For apparent power and reactive power, the unit watt of the upper interface will be replaced by VA and var, respectively. |
| Basic accuracy At 50/60 Hz, COS diameter=1 |
Power/single-phase: ± 2.3% rdg. ± 5 dgt, Power/3-phase: ± 3.0% rdg. ± 10 dgt. (load balancing) |
| Voltage/current accuracy | Voltage: ± 1.0% rdg. ± 3 dgt., Current: ± 1.3% rdg. ± 3 dgt. (45-66 Hz) |
| frequency characteristic | AC current: 45-1 kHz AC Voltage: 30-1 kHz |
| Attachment | Voltage wire 9635 (1), carrying case 9245, (1), handheld sling (1) |