Product name: YJHBZ(S)-32/85(34/90) type 630A shielded and connected to lightning arrester
specification: YJHBZ(S)-32/85(34/90) type 630A shielded and connected to lightning arrester
  Zoom Zoom in on the image
Category: High voltage electrical appliances -- Cable lightning arrester
Column tabs 
Price: factory price
Brand: Shanghai
Place of Origin: China
Column tabs 
Available Quantity: batch
delivery cycle: Spot goods (or inquire by telephone)
tabs
  Shanghai Beiyuan Industry and Trade Co.,Ltd
+86-21-66770508
+86-13916500500

Email 91way@163.com
Wechat 13916500500(Wechat)


YJHBZ(S)-32/85(34/90) type 630A shielded and connected to lightning arresterDetailed product description:Column tabs
YJHBZ (S) -32/85 (34/90) type 630A shielded and connected to lightning arrester

YJHBZ(S) -32/85(34/90)  
Product Introduction:
The rear joint lightning arrester is mainly used for electrical equipment such as ring main units and distribution boxes.  
Product features:
The rear joint lightning arrester provides lightning protection and overvoltage protection for electrical equipment. The pressure release device ensures that the lightning arrester remains intact even under fault currents of 16kA and 800kA. Good nonlinear resistors enable lightning arresters to have residual low voltage, same current capacity, fast response time, and flat steep wave characteristics, ensuring the operation of power transmission and transformation equipment.  
Adopting a unique explosion-proof device, the lightning arrester can reliably operate in the event of long-term operation degradation or damage due to lightning strikes under any grounding method at the neutral point. Effectively prevent lightning arresters from exploding and permanent grounding faults in the power system, ensuring the safe operation of the power grid.  
The rear joint lightning arrester is a fully insulated, fully sealed, and fully shielded product.  
100% factory testing, stable quality
Applicable voltage level: 12/24kV

Performance parameters of 10-24kV post connected lightning arrester:

name

YJHBZ -32/85

YJHBS -34/90

System nominal voltage

20kV

20kV

Power frequency reference voltage

32 kV

34 kV

Continuous operating voltage

25.6 kV

27.2 kV

Residual voltage caused by lightning impulse

85 kV

90 kV

Voltage at 1mA DC

≥47 kV

≥50 kV

0.75U1mA DC leakage current

≤50цA

≤50цA

2ms square wave shock capacity (18 times)

180A

180A

Composite jacket insulation (5 minutes)

54 kV

54 kV


YJHBZ (S) -32/85 (34/90) type 630A shielded and connected to lightning arrester

YJHBZ(S)-32/85(34/90) type 630A shielded and connected to lightning arrester