YXG-150-KG Inductive Contact Pressure Gauge (with Switching Amplifier)
The contact points of the instrument are equipped with contactless induction switches, which result in no contact corrosion, high sensitivity, fast response, high control accuracy, and no hysteresis or jumping phenomenon, making it safe and reliable.
There are two switch amplifiers installed inside the instrument, which output high and low voltage signals of 0.3V-24V for process control and can also drive low-power loads.
Technical parameters:
Execution standard: Q/320211DGH08-2002
Accuracy level: 1.6 level
Measurement range: 0-0.16, 0-0.25, 0-0.4, 0-0.6, 0-1.0, 0-1.6, 0-2.5, 0-4.0, 0-6.0, 0-10, 0-16, 0-25, 0-60, -0.1-0.15, -0.1-0.3, -0.1-0.5, -0.1-0.9, -0.1-1.5, -0.1-2.4MPa
Working temperature: -10 ℃ -55 ℃
Protection level: IP54
Power supply voltage: DC24V, current: maximum 100mA
Output: High and low levels: 0.3V/24V, current: ≤ 30mA.
Contact type and control method:
| model |
schematic diagram |
Contact type |
The position of the control panel when it changes with the indicator needle |
Equivalent contact point |
| YXG-150-KG21 |
 |
upper and lower limits |
1. The control panels are all located inside the induction switch. 2. When the indicator needle moves up (or down), the control chip of the upper limit contact (lower limit contact) exits the sensing switch. |
1. Both contacts are disconnected, outputting a low level. 2. Connect the upper limit contact (lower limit contact) and output a high level |
| YXG-150-KG11 |
 |
Double upper limit |
1. The control panels are all located inside the induction switch. 2. When the indicator pin goes up, the control pads of contacts 1 and 2 exit the induction switch in sequence. |
1. Both contacts are disconnected, outputting a low level. 2. Connect contacts 1 and 2 in sequence and output a high level. |
| YXG-150-KG22 |
 |
Double lower limit |
1. The control panels are all located inside the induction switch. 2. When the indicator pin descends, the control pads of contacts 2 and 1 exit the induction switch in sequence |
1. Both contacts are disconnected, outputting a low level. 2. Connect contacts 2 and 1 in sequence and output a high level. |
| YXG-150-KG1 |
 |
Single upper limit |
1. The control panel is located inside the induction switch. 2. When the indicator pin goes up, the contact control piece exits the induction switch. |
1. Contact disconnected, output low level. 2. Connect the contact and output a high level. |
| YXG-150-KG2 |
 |
Single lower limit |
1. The control panel is located inside the induction switch. 2. When the indicator pin descends, the contact control piece exits the induction switch. |
1. Contact disconnected, output low level. 2. Connect the contact and output a high level. |
|
Note: In the diagram The control chip is inside the induction switch, and the indicating contact is in a disconnected state.
The control panel is located outside the induction switch, and the indicating contact is in a connected state. |