CTS-DLI Capacitive level gaugeDetailed product description:Column tabs
Introduction to CTS-DLI Capacitive Level Gauge

Overview

The capacitive level meter, due to the use of a specially designed series of chips, has achieved pulse based conversion of level signals for the first time and self correction processing of level signals for the first time, thus achieving a perfect combination of strong functionality and easy operation for level measurement! This fully reflects the spirit and ability of our factory to keep up with the times. It consists of three basic functions: level display, alarm, and transmission. Users can choose one, two, or all three according to their actual needs, making it particularly suitable for on-site display and control of various liquid and solid material crop level heights.

Technical specifications of CTS-DLI capacitive level gauge product

Working power supply: AC220V ± 10% or DC24V
Power consumption: ≤ 5W
Display mode: 41 line light column display
Measurement accuracy: ± 1% F · S
Protection level: IP65
Response delay:<2-3 seconds
Working environment temperature: -40~45 ℃
Exploration working (medium) temperature: ordinary type: -20~60 ℃
Medium temperature type: -40~200 ℃
High temperature type: -40~800 ℃
Medium pressure: Pressure type ≤ 3MPa (other models are atmospheric pressure)
Detection range: ≤ 11000p
Alarm output method: Two sets of relays with normally open and normally closed contacts, corresponding to high and low alarm outputs, can be selected at 90%, 80%, 70% and 30%, 20%, 10% of the material level respectively, and are placed at 80% and 20% when leaving the factory. (Contact capacity AC250V, 0.3A; DC28V,0.5A; Resistive load)
Transmission output: 4-20mA transmission signal

CTS-DLI Capacitive level gauge
Product Category
All product information on this website is translated by Baidu machine translation, which may not be completely accurate and is only for reference