<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - spare parts and accessories</title>
       <link>http://www.91way.com</link>
       <description>spare parts and accessories</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:06:25</pubDate>
       <item>
           <title>[commutator]Q49D type commutator </title>
           <link>http://www.91way.com/info_en/21097.html</link>
           <author></author>
           <guid></guid>
           <category>commutator</category>
           <pubDate>2026-6-18 18:41:44</pubDate>
           <comments></comments>
           <description>Q49D type commutator&lt;BR&gt;&lt;BR&gt;Number of films: 21&lt;BR&gt;Outer diameter: &amp;Oslash; 28.5 0-0.052&lt;BR&gt;Inner hole diameter: &amp;Oslash; 12+0.022 0&lt;BR&gt;&lt;BR&gt;Hook (lifting plate) outer diameter: 29 &#177; 0.15&lt;BR&gt;Axial total length: 26+0.25&lt;BR&gt;Reversing blade length: 23.5&lt;BR&gt;Hook (wire slot) length: 5.5&lt;BR&gt;Hook angle:&lt;BR&gt;Mica groove length: 15.5&lt;BR&gt;Mica groove depth: 1.1 &#177; 0.05&lt;BR&gt;Mica groove width: 0.65 &#177; 0.03&lt;BR&gt;Mica thickness: 0.5&lt;BR&gt;Inner diameter of hook end sinkhole: 14.9&lt;BR&gt;Hook end sinkhole depth: 3.5&lt;BR&gt;Hook free protrusion diameter: 23&lt;BR&gt;Hook free convex platform length: 1&lt;BR&gt;</description>
       </item>
       <item>
           <title>[commutator]QE02 type commutator </title>
           <link>http://www.91way.com/info_en/21096.html</link>
           <author></author>
           <guid></guid>
           <category>commutator</category>
           <pubDate>2026-6-18 18:41:35</pubDate>
           <comments></comments>
           <description>QE02 type commutator&lt;BR&gt;&lt;BR&gt;Code: QE02&lt;BR&gt;Number of films: 25&lt;BR&gt;Outer diameter: &amp;Oslash; 59+0.10-0.10&lt;BR&gt;Inner hole diameter: &amp;Oslash; 24.1+0.100&lt;BR&gt;&lt;BR&gt;Hook (lifting plate) outer diameter: 58 &#177; 0.10&lt;BR&gt;Axial total length: 19.5 &#177; 0.20&lt;BR&gt;Reversing blade length: 4.65&lt;BR&gt;Hook (welding wire slot) length: 1.7&lt;BR&gt;Hook angle: 30 &#176;&lt;BR&gt;Mica groove length: milled through&lt;BR&gt;Mica groove depth: 0.7&lt;BR&gt;Mica groove width: 0.7&lt;BR&gt;Mica thickness:&lt;BR&gt;Inner diameter of hook end sinkhole: 27&lt;BR&gt;Depth of hook end sinkhole: 2&lt;BR&gt;Diameter of hooked convex platform:&lt;BR&gt;Hook free convex platform length:&lt;BR&gt;</description>
       </item>
       <item>
           <title>[commutator]DZQB-11-10 commutator </title>
           <link>http://www.91way.com/info_en/21095.html</link>
           <author></author>
           <guid></guid>
           <category>commutator</category>
           <pubDate>2026-6-18 18:41:27</pubDate>
           <comments></comments>
           <description>DZQB-11-10 commutator&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]XJ2370 type high-voltage probe </title>
           <link>http://www.91way.com/info_en/26934.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:35</pubDate>
           <comments></comments>
           <description>XJ2370 High Voltage Probe&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=2 cellPadding=1 width=650 align=center heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Model number&lt;/TD&gt;
&lt;TD&gt;XJ23700 3kV high voltage probe&lt;/TD&gt;
&lt;TD&gt;XJ23702 type 30kV high voltage probe&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=9&gt;
&lt;P&gt;sex&lt;/P&gt;
&lt;P&gt;can&lt;/P&gt;
&lt;P&gt;point&lt;/P&gt;
&lt;P&gt;mark&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;rise time&lt;/TD&gt;
&lt;TD&gt;≒35ns&lt;/TD&gt;
&lt;TD&gt;≒17.5ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum allowable input voltage&lt;/TD&gt;
&lt;TD&gt;3kV&lt;/TD&gt;
&lt;TD&gt;30kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;input impedance&lt;/TD&gt;
&lt;TD&gt;100M次//3pF&lt;/TD&gt;
&lt;TD&gt;100M次//12pF&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;decay ratio&lt;/TD&gt;
&lt;TD&gt;100孟1&lt;/TD&gt;
&lt;TD&gt;1000孟1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Upward impulse&lt;/TD&gt;
&lt;TD colSpan=2&gt;Cooperate with the oscilloscope, not exceeding the rated value of the corresponding oscilloscope&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;phase correction&lt;/TD&gt;
&lt;TD colSpan=2&gt;By using an oscilloscope, correct compensation can be obtained&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Electrical insulation resistance&lt;/TD&gt;
&lt;TD&gt;≡100M次&lt;/TD&gt;
&lt;TD&gt;≡100M次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Interface terminal&lt;/TD&gt;
&lt;TD&gt;Q9&lt;/TD&gt;
&lt;TD&gt;Q9&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;cable length&lt;/TD&gt;
&lt;TD&gt;1.5m&lt;/TD&gt;
&lt;TD&gt;1.5m&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for XJ23200 oscilloscope </title>
           <link>http://www.91way.com/info_en/26933.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Probe for XJ23200 100MHz Oscilloscope&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Indicator&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;switch position&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;&#215;10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;&#215;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;bandwidth&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;DC-100MHz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;DC-6MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;rise time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;≒3.5nS&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;≒50nS&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;decay ratio&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10垃1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1垃1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;scope of compensation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;18pF-45pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10M次//16pF&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1M次//50pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Upward impulse&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Phase calibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Maximum allowable input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;400V(DC-ACp)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Electrical insulation resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;≡100M次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Output plug/interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;BNC(Q9)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;cable length&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;1.2m&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for EN_1 oscilloscope </title>
           <link>http://www.91way.com/info_en/26932.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:17</pubDate>
           <comments></comments>
           <description>Probe for XJ23202 60MHz Oscilloscope&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Indicator&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;switch position&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;&#215;10&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;&#215;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;bandwidth&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;DC-60MHz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;DC-6MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;rise time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;≒5nS&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;≒50nS&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;decay ratio&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10垃1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1垃1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;scope of compensation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;22pF-45pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;P align=center&gt;10M次//20pF&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;1M次//50pF&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Upward impulse&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Phase calibration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Maximum allowable input voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;400V(DC-ACp)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Electrical insulation resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;≡100M次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Output plug/interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;BNC(Q9)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;cable length&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;P align=center&gt;1.2m&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Probe for EN_1 oscilloscope </title>
           <link>http://www.91way.com/info_en/26931.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:49:09</pubDate>
           <comments></comments>
           <description>XJ23400A 20MHz oscilloscope probe
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;serial number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;Name&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Indicator&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;switch position&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;&#215;10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;&#215;1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;bandwidth&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;DC-20MHz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;DC-6MHz&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;rise time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;≒17.5nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;≒50nS&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;decay ratio&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;10垃1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;1垃1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;scope of compensation&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;25pF-45pF&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;input impedance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV align=center&gt;10M次//25pF&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;1M次//50pF&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Upward impulse&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Cooperate with the oscilloscope to ensure that it does not exceed the rated value of the corresponding oscilloscope&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Phase calibration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;Cooperating with an oscilloscope can obtain correct compensation&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Maximum allowable input voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;400V(DC-ACp)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Electrical insulation resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;≡100M次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;Output plug/interface&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;BNC(Q9)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=65&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV&gt;cable length&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=335 colSpan=2&gt;
&lt;DIV align=center&gt;1.2m&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]YD-1 Four terminal testing fixture </title>
           <link>http://www.91way.com/info_en/26791.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:59</pubDate>
           <comments></comments>
           <description>YD-1 Four Terminal Test Fixture&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]CD series testing pliers </title>
           <link>http://www.91way.com/info_en/23349.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:51</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The CD series test pliers use ABS with high pressure resistance and strength as the clamp frame, and high-quality copper material with a certain hardness. After stamping and special nickel plating treatment, the pliers are formed into jaws. The jaws are divided into upper and lower layers and insulated to separate current and voltage. The CD series testing pliers have movable jaws and surface contact, making them convenient, safe, strong, and have good contact performance. CD-1 type test pliers are suitable for contact resistance testing; CD-2 type test pliers are suitable for circuit resistance testing; CD-3 type test pliers are suitable for various high-voltage switch and other tests.&lt;BR&gt;&lt;BR&gt;CD series test pliers with several different specifications and parameters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201304/20130414071710391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 545px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;CD series test pliers with different shapes&quot; src=&quot;/upload2013/201304/20130414071710391.jpg&quot; width=545 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201304/20130414071717313.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 529px; HEIGHT: 364px&quot; border=0 hspace=0 alt=&quot;CD series test pliers with external dimensions&quot; src=&quot;/upload2013/201304/20130414071717313.jpg&quot; width=529 height=364&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CD series testing pliers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]HNO3 Stainless steel pipe </title>
           <link>http://www.91way.com/info_en/20864.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:42</pubDate>
           <comments></comments>
           <description>HNO3 stainless steel pipe&lt;BR&gt;&lt;BR&gt;All stainless steel pipes are passivated with HNO3 and cleaned with methanol ultrasonic cleaning to ensure chromatographic use&lt;BR&gt;Smooth inner surface ensures optimal gas-liquid flow&lt;BR&gt;The annealed outer surface is bright and free of burrs, which is conducive to joint connection&lt;BR&gt;Suggest using a 0.020 &quot;or 0.030&quot; ID tube to transport the mobile phase from the pump to the injection valve&lt;BR&gt;It is recommended to use a 0.010 &quot;ID tube from the injection valve to the chromatographic column and from the chromatographic column to the detector, and keep these two distances as short as possible. This can reduce the out of column effect&lt;BR&gt;Provide various lengths of pre cut stainless steel pipes&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;Part NO.&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;outer diameter&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;inner diameter&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;625-04&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.005&quot;ㄗ0.1mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;625-05&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.007&quot;ㄗ0.2mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.01&quot;ㄗ0.25mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.02&quot;ㄗ0.5mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.03&quot;ㄗ0.75mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=82&gt;
&lt;DIV&gt;eleven thousand two hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV&gt;1/16§&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV&gt;0.04&quot;ㄗ1.0mmㄘ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HNO3 stainless steel pipe&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Instrument accessories]Column-Guard protective column </title>
           <link>http://www.91way.com/info_en/20863.html</link>
           <author></author>
           <guid></guid>
           <category>Instrument accessories</category>
           <pubDate>2026-6-17 11:48:34</pubDate>
           <comments></comments>
           <description>Column Guard Protection Column&lt;BR&gt;&lt;BR&gt;In HPLC systems, it cannot be guaranteed that the injected samples can be completely eluted, especially for traditional Chinese medicine and blood samples. Although the injection volume is small, there will always be some residue in the column head after each injection, which will cause column head failure over time. This new type of protective column component combines the strength of stainless steel with the convenience and efficiency of PEEK pre filled column cores. Without the need for tools, place a small section of the protective column with the same packing as the column between the injection valve and the chromatographic column, which will extend the lifespan of the chromatographic column and ensure reproducibility of results.&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=90&gt;Part No&lt;/TD&gt;
&lt;TD width=360&gt;Desc.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and twenty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including C18/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and thirty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including C8/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and forty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core NH)&lt;SUB&gt;two&lt;/SUB&gt;/3 of them)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and fifty&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core Sil/3 pieces)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;six hundred thousand two hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;Protective column components (including Phen/3 column cores)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and ten&lt;/TD&gt;
&lt;TD width=360&gt;Protective column components (including column core CN/3 pieces)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred thousand two hundred and twenty-one&lt;/TD&gt;
&lt;TD width=360&gt;Protective column cover&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and twelve thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), C-18&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and twenty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), C-8&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and thirty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), Silica&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and forty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), NH&lt;SUB&gt;two&lt;/SUB&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=90&gt;six hundred and fifty-two thousand one hundred and eleven&lt;/TD&gt;
&lt;TD width=360&gt;Core (10/bag), CN&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;six hundred and sixty-two thousand one hundred and eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;Core (10/bag), Phen&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;Column Guard Protection Column&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]NLY series crimping type cable clamp </title>
           <link>http://www.91way.com/info_en/26649.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:29:17</pubDate>
           <comments></comments>
           <description>NLY series crimping type cable clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; id=glftable4 border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Applicable outer diameter of steel strand (mm)&lt;/TD&gt;
&lt;TD colSpan=4&gt;Main dimensions (mm)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Nominal failure load (kN)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;C&lt;/TD&gt;
&lt;TD&gt;M&lt;/TD&gt;
&lt;TD&gt;L&lt;/TD&gt;
&lt;TD&gt;L1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-50&lt;/TD&gt;
&lt;TD&gt;1&#215;7-9.0-1370-GB1200-75&lt;/TD&gt;
&lt;TD&gt;sixty-two&lt;/TD&gt;
&lt;TD&gt;eighteen&lt;/TD&gt;
&lt;TD&gt;three hundred and twenty&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD&gt;sixty-five point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-70&lt;/TD&gt;
&lt;TD&gt;1&#215;7-9.0-1370-GB1200-75&lt;/TD&gt;
&lt;TD&gt;sixty-two&lt;/TD&gt;
&lt;TD&gt;eighteen&lt;/TD&gt;
&lt;TD&gt;three hundred and twenty&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty&lt;/TD&gt;
&lt;TD&gt;ninety-one point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-100&lt;/TD&gt;
&lt;TD&gt;1&#215;19-13.0-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;seventy-four&lt;/TD&gt;
&lt;TD&gt;twenty-two&lt;/TD&gt;
&lt;TD&gt;five hundred&lt;/TD&gt;
&lt;TD&gt;three hundred&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-nine point six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-120&lt;/TD&gt;
&lt;TD&gt;1&#215;19-14.0-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;eighty-two&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty-seven point six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-135&lt;/TD&gt;
&lt;TD&gt;1&#215;19-15.0-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;eighty-two&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD&gt;one hundred and eighty-eight point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-150&lt;/TD&gt;
&lt;TD&gt;1&#215;19-16.0-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;one hundred and four&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;two hundred and nine point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-165&lt;/TD&gt;
&lt;TD&gt;1&#215;37-16.8-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;one hundred and four&lt;/TD&gt;
&lt;TD&gt;twenty-seven&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty-eight&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;two hundred and thirty point four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-180&lt;/TD&gt;
&lt;TD&gt;1&#215;37-17.5-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;one hundred and fourteen&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;six hundred and forty&lt;/TD&gt;
&lt;TD&gt;four hundred and fifty&lt;/TD&gt;
&lt;TD&gt;two hundred and fifty-one point four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-195&lt;/TD&gt;
&lt;TD&gt;1&#215;37-18.2-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;one hundred and fourteen&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;six hundred and forty&lt;/TD&gt;
&lt;TD&gt;four hundred and sixty&lt;/TD&gt;
&lt;TD&gt;two hundred and seventy-two point three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-265&lt;/TD&gt;
&lt;TD&gt;1&#215;37-21.0-1470-GB1200-75&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-eight&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;six hundred and seventy&lt;/TD&gt;
&lt;TD&gt;four hundred and ninety&lt;/TD&gt;
&lt;TD&gt;three hundred and sixty-seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-100E&lt;/TD&gt;
&lt;TD&gt;1&#215;19-13.0-1570-GB1200-88&lt;/TD&gt;
&lt;TD&gt;eighty-eight&lt;/TD&gt;
&lt;TD&gt;twenty-two&lt;/TD&gt;
&lt;TD&gt;four hundred and ninety&lt;/TD&gt;
&lt;TD&gt;three hundred&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty-one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-125E&lt;/TD&gt;
&lt;TD&gt;1&#215;19-14.5-1570-GB1200-88&lt;/TD&gt;
&lt;TD&gt;ninety-four&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;five hundred and eighty&lt;/TD&gt;
&lt;TD&gt;three hundred and eighty&lt;/TD&gt;
&lt;TD&gt;one hundred and eighty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-150E&lt;/TD&gt;
&lt;TD&gt;1&#215;19-16.0-1570-GB1200-88&lt;/TD&gt;
&lt;TD&gt;one hundred and four&lt;/TD&gt;
&lt;TD&gt;twenty-seven&lt;/TD&gt;
&lt;TD&gt;six hundred and ten&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-180E&lt;/TD&gt;
&lt;TD&gt;1&#215;19-17.5-1570-GB1200-88&lt;/TD&gt;
&lt;TD&gt;one hundred and fourteen&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;six hundred and forty&lt;/TD&gt;
&lt;TD&gt;four hundred and twenty&lt;/TD&gt;
&lt;TD&gt;two hundred and seventy-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NLY-240E&lt;/TD&gt;
&lt;TD&gt;1&#215;19-20.0-1570-GB1200-88&lt;/TD&gt;
&lt;TD&gt;one hundred and twenty-eight&lt;/TD&gt;
&lt;TD&gt;thirty-six&lt;/TD&gt;
&lt;TD&gt;six hundred and seventy&lt;/TD&gt;
&lt;TD&gt;four hundred and forty&lt;/TD&gt;
&lt;TD&gt;three hundred and fifty-seven&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;The body and inner wedge are made of malleable cast iron (NX-4 is a cast steel component), and the surface is hot-dip galvanized.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150301171129793.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 170px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of NLY series crimping type cable clamps&quot; src=&quot;/upload2015/201503/20150301171129793.jpg&quot; width=500 height=170&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]NX series wedge type cable clamp </title>
           <link>http://www.91way.com/info_en/26648.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:29:08</pubDate>
           <comments></comments>
           <description>NX series wedge type cable clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Industry standard model&lt;/TD&gt;
&lt;TD colSpan=2&gt;Applicable steel strand&lt;/TD&gt;
&lt;TD colSpan=4&gt;Main dimensions&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Nominal failure load (kN)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;Weight (kg)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Cross section (mm2)&lt;/TD&gt;
&lt;TD&gt;Outer diameter (mm)&lt;/TD&gt;
&lt;TD&gt;C&lt;/TD&gt;
&lt;TD&gt;M&lt;/TD&gt;
&lt;TD&gt;L&lt;/TD&gt;
&lt;TD&gt;R&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NX-1&lt;/TD&gt;
&lt;TD&gt;NE-1&lt;/TD&gt;
&lt;TD&gt;25~35&lt;/TD&gt;
&lt;TD&gt;朴6.6~7.8&lt;/TD&gt;
&lt;TD&gt;eighteen&lt;/TD&gt;
&lt;TD&gt;sixteen&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;forty-five&lt;/TD&gt;
&lt;TD&gt;one point one nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NX-2&lt;/TD&gt;
&lt;TD&gt;NE-2&lt;/TD&gt;
&lt;TD&gt;50~70&lt;/TD&gt;
&lt;TD&gt;朴9.0~11.0&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;eighteen&lt;/TD&gt;
&lt;TD&gt;one hundred and eighty&lt;/TD&gt;
&lt;TD&gt;seven point three&lt;/TD&gt;
&lt;TD&gt;eighty-eight&lt;/TD&gt;
&lt;TD&gt;one point seven six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NX-3&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100~125&lt;/TD&gt;
&lt;TD&gt;朴13.0~14.0&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;twenty-four&lt;/TD&gt;
&lt;TD&gt;two hundred&lt;/TD&gt;
&lt;TD&gt;seven point three&lt;/TD&gt;
&lt;TD&gt;one hundred and forty-three&lt;/TD&gt;
&lt;TD&gt;three point two zero&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;NX-4&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;135~150&lt;/TD&gt;
&lt;TD&gt;朴15.0~16.0&lt;/TD&gt;
&lt;TD&gt;twenty-eight&lt;/TD&gt;
&lt;TD&gt;twenty-seven&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty-four&lt;/TD&gt;
&lt;TD&gt;five point three zero&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;The body and inner wedge are made of malleable cast iron (NX-4 is a cast steel component), and the surface is hot-dip galvanized.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150301170818296.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 300px; HEIGHT: 228px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of NX series wedge-shaped cable clamps&quot; src=&quot;/upload2015/201503/20150301170818296.jpg&quot; width=300 height=228&gt;&lt;/A&gt;&lt;/P&gt;&lt;!--衵晚耀輸--&gt;&lt;!--笢窒遺殤--&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SYG series compression type copper aluminum transition equipment wire clamp A(B) </title>
           <link>http://www.91way.com/info_en/26647.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:29:00</pubDate>
           <comments></comments>
           <description>SYG series compression type copper aluminum transition equipment wire clamp A (B)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 align=middle&gt;model&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Applicable conductor&lt;BR&gt;&lt;/TD&gt;
&lt;TD colSpan=6 align=middle&gt;Main dimensions&lt;/TD&gt;
&lt;TD rowSpan=2 align=middle&gt;Reference weight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;model&lt;/TD&gt;
&lt;TD align=middle&gt;outer diameter&lt;/TD&gt;
&lt;TD align=middle&gt;b&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;D&lt;/TD&gt;
&lt;TD align=middle&gt;L&lt;/TD&gt;
&lt;TD align=middle&gt;a&lt;/TD&gt;
&lt;TD align=middle&gt;耳&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-l20/7A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-l20/7&lt;/TD&gt;
&lt;TD align=middle&gt;fourteen point five zero&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-six&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen&lt;/TD&gt;
&lt;TD align=middle&gt;zero point two eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-l50/8A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-l50/8&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;ninety&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;seventeen point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point three three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-l50/20A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-l50/20&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen point six seven&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;ninety&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;18.O&lt;/TD&gt;
&lt;TD align=middle&gt;zero point three two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-l85/l0A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-l85/l0&lt;/TD&gt;
&lt;TD align=middle&gt;18.OO&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-two&lt;/TD&gt;
&lt;TD align=middle&gt;ninety&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;nineteen point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four zero&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-l85/25A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-l85/25&lt;/TD&gt;
&lt;TD align=middle&gt;eighteen point nine zero&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-two&lt;/TD&gt;
&lt;TD align=middle&gt;ninety&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point three nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-210/l0A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-210/10&lt;/TD&gt;
&lt;TD align=middle&gt;nineteen&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-four&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-210/25A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-210/25&lt;/TD&gt;
&lt;TD align=middle&gt;nineteen point nine eight&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;ten&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-four&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-one point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-240/30A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-240/30&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-one point six zero&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-six&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;23.O&lt;/TD&gt;
&lt;TD align=middle&gt;zero point four four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-300/l5A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-300/l5&lt;/TD&gt;
&lt;TD align=middle&gt;23.Ol&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and ten&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-four point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point seven nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-300/20A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-300/20&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-three point four three&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and ten&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;25.O&lt;/TD&gt;
&lt;TD align=middle&gt;zero point seven eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-300/25A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-300/25&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-three point seven six&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and ten&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point seven seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-300/40A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-300/40&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-three point nine four&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and ten&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point seven seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-400/20A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-400/20&lt;/TD&gt;
&lt;TD align=middle&gt;26.9l&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;thirteen&lt;/TD&gt;
&lt;TD align=middle&gt;forty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-eight point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point eight five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-400/25A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-400/25&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-six point six four&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;thirteen&lt;/TD&gt;
&lt;TD align=middle&gt;forty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-eight point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point eight five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-400/35A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-400/35&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-six point eight two&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;thirteen&lt;/TD&gt;
&lt;TD align=middle&gt;forty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-eight point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point eight five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-400/50A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-400/50&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-seven point six three&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;
&lt;TD align=middle&gt;thirteen&lt;/TD&gt;
&lt;TD align=middle&gt;forty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-nine point five&lt;/TD&gt;
&lt;TD align=middle&gt;zero point eight three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-500/35A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-500/35&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen&lt;/TD&gt;
&lt;TD align=middle&gt;fifty-two&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-500/45A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-500/45&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen&lt;/TD&gt;
&lt;TD align=middle&gt;fifty-two&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-500/65A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-500/65&lt;/TD&gt;
&lt;TD align=middle&gt;thirty point nine six&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;
&lt;TD align=middle&gt;sixteen&lt;/TD&gt;
&lt;TD align=middle&gt;fifty-two&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;eighty-five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-two point five&lt;/TD&gt;
&lt;TD align=middle&gt;one point one zero&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-630/45A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-630/45&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-three point six zero&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;
&lt;TD align=middle&gt;sixty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-five point five&lt;/TD&gt;
&lt;TD align=middle&gt;one point eight four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-630/55A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-630/55&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-four point three two&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;
&lt;TD align=middle&gt;sixty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-six&lt;/TD&gt;
&lt;TD align=middle&gt;one point eight three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-630/80A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-630/80&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-four point eight two&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;
&lt;TD align=middle&gt;sixty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-six point five&lt;/TD&gt;
&lt;TD align=middle&gt;one point eight two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-800/55A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-800/55&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-eight point four zero&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-two&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;3.O5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-800/70A&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-800/70&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-eight point five eight&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-two&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;
&lt;TD align=middle&gt;3.O2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SYG-800/lOOA&lt;/TD&gt;
&lt;TD align=middle&gt;LGJ-800/l00&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-eight point nine eight&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-two&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and seventy&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;
&lt;TD align=middle&gt;3.O2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150301170149770.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 249px; HEIGHT: 247px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of wire clamp A (B) for SYG series compression type copper aluminum transition equipment&quot; src=&quot;/upload2015/201503/20150301170149770.jpg&quot; width=249 height=247&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201503/20150301170158534.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 249px; HEIGHT: 147px&quot; border=0 hspace=0 alt=&quot;Outline drawing of SYG series compression type copper aluminum transition equipment clamp A (B)&quot; src=&quot;/upload2015/201503/20150301170158534.jpg&quot; width=249 height=147&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]JGH-3 type single core cable clamp </title>
           <link>http://www.91way.com/info_en/25747.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:51</pubDate>
           <comments></comments>
           <description>The JGH-3 single core cable clamp is made of high-strength anti-corrosion aluminum alloy material and comes with a chloroprene rubber pad. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Suitable for fixed placement of single core high-voltage cables in tunnels, trenches, elevated structures, and other occasions. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The clamping mechanism of JGH-3 single core cable clamp adopts bolt and spring flexible fixation, and the fixed cable is wrapped with rubber pads, which does not damage the cable,&lt;BR&gt;The bottom bolt hole is an open long waist shaped hole, and the installation hole spacing can be adjusted within a certain range.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;Applicable cable outer diameter&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;L1&#177;10ㄗmmㄘ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;L2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;DIV align=center&gt;L3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;DIV align=center&gt;L4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;DIV align=center&gt;JGH-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;朴121-朴145&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;one hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=70&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;DIV align=center&gt;ninety&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Product Structure Diagram:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201408/20140830055251844.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 558px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JGH-3 type single core cable clamp&quot; src=&quot;/upload2014/201408/20140830055251844.jpg&quot; width=680 height=558&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]H type parallel groove clamp </title>
           <link>http://www.91way.com/info_en/24082.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:43</pubDate>
           <comments></comments>
           <description>Compared with traditional wire clamps, H-type wire clamps have the following obvious advantages:&lt;BR&gt;1. H-type wire clamps can be used to crimp aluminum wire to aluminum wire, aluminum wire to copper wire, as well as to crimp wires of the same or different diameters.&lt;BR&gt;2. The H-type wire clamp is designed with an enlarged anode, without copper aluminum transition issues, and will not corrode.&lt;BR&gt;3. The H-type wire clamp is filled with anti oxidation protective oil, which can prevent corrosion and enhance conductivity. The structure is simple and integrally formed, ensuring product quality. When using hydraulic tools for crimping, the quality of the crimping can be guaranteed.&lt;BR&gt;4. The H-type wire clamp tightly covers the wire after crimping and connecting it, rather than locally contacting the wire. The current passes through the complete contact surface, with uniform distribution, low resistance, low temperature rise, few faults, and good power supply reliability.&lt;BR&gt;5. The H-type wire clamp only requires 6 specifications to fully meet the crimping connection needs of all 16-240mm &amp;sup2; aluminum stranded wires, aluminum core insulated wires, steel core aluminum stranded wires, copper stranded wires, and copper core insulated wires. It can replace 5 specifications of GB2335.1 parallel groove clamp, 15 specifications of GB2335.2 jumper clamp, and 18 specifications of GB2340T clamp, totaling 38 specifications.&lt;BR&gt;6. H-type wire clamps, due to their limited specifications, can alleviate inventory and capital backlog issues, as well as reduce human resources for warehouse hardware construction, procurement, and warehouse management. Small specifications, light weight, easy to carry, can reduce the workload of construction personnel and increase work efficiency.&lt;BR&gt;7. The H-type wire clamp crimping connection is fast, which is conducive to power fault repair, early power supply, and reduces the social harm caused by power outages, especially in traffic signals, furnaces, refrigeration, and high-tech industries.&lt;BR&gt;8. The H-type wire clamp has good tension, resistance, and temperature rise conditions, with fewer faults, which can reduce power line energy loss and save national energy. It will not cause power outages or affect electricity sales revenue due to joint accidents.&lt;BR&gt;9. The H-type wire clamp is lightweight and has good functionality. Replacing the parallel groove wire clamp with it can save a lot of national resources. Two clamps are required for the connection of each wire, and only one H-type clamp is needed. Due to the same purpose of use, the weight of the parallel groove clamp is about 9 times more than that of the H-type clamp.&lt;BR&gt;10. When using H-type wire clamps for live work, only one is needed for each connection, and hydraulic pliers with insulated handles are used for crimping, making construction simple and preventing electric shock accidents for workers.&lt;BR&gt;11. GB2335.1 Parallel groove clamps can only clamp aluminum stranded wires and steel core aluminum stranded wires, and cannot clamp copper stranded wires. They can only clamp wires of the same diameter and cannot clamp wires of different diameters, which greatly limits their functionality.&lt;BR&gt;12. The parallel groove clamp is fastened with bolts and connected with aluminum sheets, resulting in a small contact area, uneven current distribution, high resistance, and high temperature rise. Moreover, its contact surface is difficult to avoid corrosion and accidents under wind and rain invasion.&lt;BR&gt;13. When the parallel trench clamp is used for live work, two or more bolts are required at each joint. The operator needs to wear rubber gloves on both hands and leather gloves, and use a wrench tool to lock the nut. The action is not flexible and the construction difficulty is high, making it more prone to electric shock accidents.&lt;BR&gt;14. Regardless of the type of bolt used for the parallel groove clamp, the torque applied to the nut should be appropriate and correct in order to maintain a good connection. However, in reality, the quality of on-site construction personnel varies, making it difficult to obtain an appropriate torque. Excessive pressure can cause bolt breakage or deformation of the connecting wire, while insufficient pressure can lead to high contact resistance and temperature rise, which can easily cause connection failure accidents, making it its biggest disadvantage.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SL Aluminum equipment wire clamp </title>
           <link>http://www.91way.com/info_en/19189.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:34</pubDate>
           <comments></comments>
           <description>SL Aluminum Equipment Wire Clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=166&gt;
&lt;DIV&gt;model&lt;BR&gt;Type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=160&gt;
&lt;DIV&gt;Applicable conductor&lt;BR&gt;Conductor mm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV&gt;Main dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;L&lt;SUB&gt;one&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;L&lt;SUB&gt;two&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-1 (Single hole)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;35-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-2 (Single hole)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;70-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-3 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;35-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-4 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;70-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-5 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;120-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-6 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;185-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-7 (four hole) four hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;120-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-8 four hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;185-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]ST series copper equipment wire clamp </title>
           <link>http://www.91way.com/info_en/19188.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:26</pubDate>
           <comments></comments>
           <description>ST series copper equipment wire clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=166&gt;
&lt;DIV&gt;model&lt;BR&gt;Type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=160&gt;
&lt;DIV&gt;Applicable conductor&lt;BR&gt;Conductor mm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV&gt;Main dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;L&lt;SUB&gt;one&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;L&lt;SUB&gt;two&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-1 (Single hole)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;35-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-2 (Single hole)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;70-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and thirty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-3 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;35-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-4 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;70-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;one hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-5 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;120-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-6 (double hole) double hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;185-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-7 (four hole) four hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;120-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=166&gt;
&lt;DIV&gt;SL-8 four hole&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=160&gt;
&lt;DIV&gt;185-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;DIV&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=167&gt;
&lt;DIV&gt;two hundred and thirty-nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SLG Copper aluminum equipment wire clamp </title>
           <link>http://www.91way.com/info_en/19187.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:17</pubDate>
           <comments></comments>
           <description>The SLG copper aluminum equipment wire clamp is manufactured using internal light welding or friction welding processes. According to customer requirements, copper Aluminum transition can also be manufactured using brazing technology&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=35 rowSpan=2 width=&quot;40%&quot; align=middle&gt;Model Catalog No&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;20%&quot; align=middle&gt;Applicable conductor&lt;BR&gt;Conductor mm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/TD&gt;
&lt;TD height=35 colSpan=4 align=middle&gt;Main dimensions (mm)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;B&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;A&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;L&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;L1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SLG-1&lt;/TD&gt;
&lt;TD align=middle&gt;35-50&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and forty-five&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SLG-2&lt;/TD&gt;
&lt;TD align=middle&gt;70-95&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;
&lt;TD align=middle&gt;five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and seventy-five&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SLG-3&lt;/TD&gt;
&lt;TD align=middle&gt;120-150&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;six&lt;/TD&gt;
&lt;TD align=middle&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;SLG-4&lt;/TD&gt;
&lt;TD align=middle&gt;185-240&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;
&lt;TD align=middle&gt;six&lt;/TD&gt;
&lt;TD align=middle&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and twenty-five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]JLC bolt type C wire clamp </title>
           <link>http://www.91way.com/info_en/11305.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:09</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;JLC bolt type C-type clamp specifications and technical parameters&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200912/20091224114825742.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 677px; HEIGHT: 463px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLC bolt type C-type wire clamp&quot; src=&quot;/upload2009/200912/20091224114825742.jpg&quot; width=677 height=463&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BTD series European insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11304.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:28:00</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=118&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=112&gt;
&lt;DIV align=center&gt;Maximum current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=132&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;main storyline&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=118&gt;
&lt;DIV align=center&gt;branch&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-041F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-101F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-121F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2.5-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-201F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;35-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and seventy-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-281F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-185&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-401F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-185&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&#215;M8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-431F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;70-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and seventy-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&#215;M10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BTD-451F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2&#215;M10&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;BTD series European insulation puncture wire clamp&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZF10-95/25 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11303.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:52</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Applicable voltage (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZF10-95/25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJCF-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;25-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and forty-four point five&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety-two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;BZF10-95/25 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZF10-185/95 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11302.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:43</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Applicable voltage (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZF10-185/95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJCF10-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;95-185&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and fifty-two&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and seventy-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZF10-185/95 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZF10-240/150 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11301.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:35</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Applicable voltage (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZF10-240/150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJCF10-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;150-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and seventy-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZF10-240/150 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ10-95/70 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11300.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:26</pubDate>
           <comments></comments>
           <description>BZ10-95/70 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;main storyline&lt;/TD&gt;
&lt;TD&gt;branch&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ10-95/70&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJCF10-4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16-70&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;sixty-eight&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ10-95/70 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ10-185/50 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11299.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:18</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17&gt;main storyline&lt;/TD&gt;
&lt;TD height=17&gt;branch&lt;/TD&gt;
&lt;TD height=17&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ10-185/50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC10-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-185&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16-50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-eight point five&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-seven point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ10-185/50 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ10-240/150 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11298.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:09</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;main storyline&lt;/TD&gt;
&lt;TD&gt;branch&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ10-240/150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC10-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and forty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ10-240/150 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ10-240/240 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11297.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:27:01</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Applicable wire (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Main dimensions (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum current carrying capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Number of bolts (pieces)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;main storyline&lt;/TD&gt;
&lt;TD&gt;branch&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ10-240/240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC10-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and seventy-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ10-240/240 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ240 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11296.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:52</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-8&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;95-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;83&#215;130&#215;130&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and fifty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ240 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ6 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11295.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:43</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-7&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;120-240&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-120&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;52&#215;68&#215;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;BZ6 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ4-150 Insulated wire clamp </title>
           <link>http://www.91way.com/info_en/11294.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:35</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ4-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;52&#215;61&#215;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;BZ4-150 insulated wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ3-95 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11293.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:27</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ3-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;25-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;46&#215;61&#215;100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;BZ3-95 insulation puncture wire clamp&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ2-150 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11292.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:18</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ2-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50-150&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and thirty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;46&#215;52&#215;87&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ2-150 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ2-95 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11291.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:10</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ2-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4-35(50)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and thirty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;46&#215;52&#215;87&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ2-95 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZEP Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11290.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:26:01</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZEP&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16-95&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;27&#215;41&#215;62&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZEP insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]BZ041 Insulation puncture wire clamp </title>
           <link>http://www.91way.com/info_en/11289.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:53</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;export model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;domestic model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Main line cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Branch cross-section (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (g)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Typical Applications&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;BZ041&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;JJC-1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.5-10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;26&#215;39&#215;54&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;architectural lighting&lt;BR&gt;street light&lt;BR&gt;User line connection&lt;BR&gt;Main line and main line connection&lt;BR&gt;Outdoor overhead power line&lt;BR&gt;underground cable&lt;BR&gt;Main power cable for building power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;BZ041 insulation puncture wire clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]C cable clamp </title>
           <link>http://www.91way.com/info_en/8850.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:44</pubDate>
           <comments></comments>
           <description>C-type cable clamp&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;specification&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;Scope of application (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;7.5-11&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-16&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;11-16&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;14-20&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-26&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;21-26&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;27-44&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;45-60&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-76&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;61-76&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-98&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;77-98&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-122&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;99-122&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-154&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;123-154&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-190&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;155-190&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-240&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;191-240&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-288&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;241-288&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-365&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;289-365&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-450&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;366-450&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-560&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;451-560&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-700&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;561-700&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;C-type clamp&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;T-800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=180&gt;
&lt;P align=center&gt;701-850&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;C-type cable clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SJB,SJBT,SJBL series insulated parallel groove clamp </title>
           <link>http://www.91way.com/info_en/8847.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:36</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SJB, SJBT, SJBL series insulated parallel groove clamps&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911894311474.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 463px; HEIGHT: 286px&quot; border=0 hspace=0 alt=&quot;Technical parameters of SJB, SJBT, SJBL series insulated parallel groove clamps&quot; src=&quot;/upload2009/200911/200911894311474.jpg&quot; width=463 height=286&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SJB, SJBT, SJBL series insulated parallel groove clamps&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SNX series tension clamp </title>
           <link>http://www.91way.com/info_en/8846.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:26</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SNX series tension clamp&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911893936268.jpg&quot; target=_blank&gt;&lt;/A&gt;&lt;A href=&quot;/upload2009/200911/200911894049777.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 463px; HEIGHT: 262px&quot; border=0 hspace=0 alt=&quot;Main parameters of SNX series tension clamp&quot; src=&quot;/upload2009/200911/200911894049777.jpg&quot; width=463 height=262&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SNXJ series four core bundle type tension clamp </title>
           <link>http://www.91way.com/info_en/8845.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:18</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SNXJ series four core bundle type tension clamp&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911893743147.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 485px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;Main parameters of SNXJ series four core bundle type tension clamp&quot; src=&quot;/upload2009/200911/200911893743147.jpg&quot; width=485 height=220&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SXG series suspension clamp </title>
           <link>http://www.91way.com/info_en/8844.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:09</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SXG series suspension cable clamp&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911893558719.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 467px; HEIGHT: 185px&quot; border=0 hspace=0 alt=&quot;Main parameters of SXG series suspension clamp&quot; src=&quot;/upload2009/200911/200911893558719.jpg&quot; width=467 height=185&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SJBC Series 1KV Puncture Thread Clip </title>
           <link>http://www.91way.com/info_en/8843.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:25:01</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SJBC series 1KV puncture line clamp&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911893416818.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 428px; HEIGHT: 271px&quot; border=0 hspace=0 alt=&quot;Main parameters of SJBC series 1KV puncture line clamp&quot; src=&quot;/upload2009/200911/200911893416818.jpg&quot; width=428 height=271&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]SJBC Series 10KV Puncture Thread Clip </title>
           <link>http://www.91way.com/info_en/8842.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:24:52</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;SJBC series 10KV puncture wire clamp&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911893236274.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 472px; HEIGHT: 171px&quot; border=0 hspace=0 alt=&quot;Main parameters of SJBC series 10KV puncture cable clamp&quot; src=&quot;/upload2009/200911/200911893236274.jpg&quot; width=472 height=171&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]DLJJ series cable fixing clip </title>
           <link>http://www.91way.com/info_en/8841.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:24:44</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;DLJJ series cable fixing clip&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911892833170.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 576px; HEIGHT: 628px&quot; border=0 hspace=0 alt=&quot;DLJJ series cable fixing clip external dimensions&quot; src=&quot;/upload2009/200911/200911892833170.jpg&quot; width=576 height=628&gt;&lt;/A&gt;&lt;BR&gt;DLJJ series cable fixing clip&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]JGHL-3 series cable fixing clip </title>
           <link>http://www.91way.com/info_en/8840.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:24:35</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;JGHL-3 series cable fixing clip&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911892513181.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 559px; HEIGHT: 387px&quot; border=0 hspace=0 alt=&quot;JGHL-3 series cable fixing clip technical parameters&quot; src=&quot;/upload2009/200911/200911892513181.jpg&quot; width=559 height=387&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGHL-3 series cable fixing clip&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]JGHL-0 series high-voltage cable clamps </title>
           <link>http://www.91way.com/info_en/8839.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:24:26</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;JGHL-0 series high-voltage cable clamp&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911892235358.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 485px; HEIGHT: 518px&quot; border=0 hspace=0 alt=&quot;JGHL-0 Series High Voltage Cable Fixture Technical Parameters and Outline Drawing&quot; src=&quot;/upload2009/200911/200911892235358.jpg&quot; width=485 height=518&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JGHL-0 series high-voltage cable clamp&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated wire clamp]JGHL series high-voltage suspension cable fixing clip </title>
           <link>http://www.91way.com/info_en/8838.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated wire clamp</category>
           <pubDate>2026-6-17 11:24:18</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;JGHL series high-voltage suspension cable fixing clip&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911891932401.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 535px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JGHL series high-voltage suspension cable fixing clip&quot; src=&quot;/upload2009/200911/200911891932401.jpg&quot; width=550 height=535&gt;&lt;/A&gt;&lt;BR&gt;JGHL series high-voltage suspension cable fixing clip&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F15 series AC/DC auxiliary switch </title>
           <link>http://www.91way.com/info_en/28037.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:43:24</pubDate>
           <comments></comments>
           <description>&lt;P&gt;I. Overview&lt;BR&gt;The FI5 series auxiliary switch is one of the supporting components for high-voltage switch operating mechanisms, suitable for controlling the closing and opening of high-voltage switch spring mechanisms and indicating interlocking signals.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241123095806911.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 449px; WIDTH: 617px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of F15 series AC/DC auxiliary switch&quot; src=&quot;/upload2024/202411/20241123095806911.jpg&quot; width=617 height=449&gt;&lt;/A&gt;&lt;BR&gt;Key Features:&lt;BR&gt;1. There are DC contacts specifically designed to control the closing and opening coils of DC 220V or 110V, with a breaking current of up to 10A when the current is DC220V.&lt;BR&gt;2. The contact is a silver alloy bridge type double break point structure, which has the advantages of reliable connection and anti-oxidation and corrosion resistance compared to existing auxiliary switches.&lt;BR&gt;3. This series of auxiliary switches has the advantages of simple structure, easy use, and long service life, making it an ideal replacement product.&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. The ambient air temperature ranges from -40 ⊥ to+40 ⊥;&lt;BR&gt;2. The installation location shall not exceed an altitude of 2000m;&lt;BR&gt;3. The conditions are as follows: the average relative humidity measured within 24 hours shall not exceed 95%; The average value of water vapor pressure measured within 24 hours shall not exceed 2.2KPa; The average monthly relative humidity does not exceed 90%; The average monthly water vapor pressure shall not exceed 1.8KPa, taking into account the condensation that may occur on the surface of the product due to temperature changes.&lt;BR&gt;4. Acceleration not exceeding 15m/s &amp;sup2;;&lt;BR&gt;5. The air is not significantly polluted by dust, smoke, corrosive and flammable gases, steam, or salt spray.&lt;BR&gt;&lt;BR&gt;5﹜ Structural characteristics&lt;BR&gt;1. The contact is a bridge double break structure, and the contact material is AgNilo;&lt;BR&gt;2. The switch contacts can be equipped with permanent magnet arc extinguishing, and the quantity can be made according to user requirements;&lt;BR&gt;3. It can be made into various delay contacts, and users need to provide clear technical requirements.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241123095822796.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 756px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F15 series AC/DC auxiliary switch&quot; src=&quot;/upload2024/202411/20241123095822796.jpg&quot; width=680 height=756&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F13 series AC/DC auxiliary switch </title>
           <link>http://www.91way.com/info_en/28036.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:43:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;I. Overview&lt;BR&gt;The F13 series auxiliary switch is suitable for controlling the closing and opening of high-voltage switch spring mechanisms and indicating interlocking signals. It can also be used as a conversion or combination switch and is the preferred component for operating mechanisms.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241123095431708.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 448px; WIDTH: 621px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of F13 series AC/DC auxiliary switch&quot; src=&quot;/upload2024/202411/20241123095431708.jpg&quot; width=621 height=448&gt;&lt;/A&gt;&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. Environmental air temperature: -40 ⊥~+40 ⊥;&lt;BR&gt;2. The installation location shall not exceed an altitude of 2000m;&lt;BR&gt;3. The conditions are as follows: the average relative humidity measured within 24 hours shall not exceed 95%; The average value of water vapor pressure measured within 24 hours shall not exceed 2.2KPa; The average monthly relative humidity does not exceed 90%; The average monthly water vapor pressure shall not exceed 1.8Kpa, taking into account the condensation that may occur on the surface of the product due to temperature changes;&lt;BR&gt;4. Acceleration not exceeding 15m/S &amp;sup2;;&lt;BR&gt;5. The air is not significantly polluted by dust, smoke, corrosive and flammable gases, steam, or salt spray.&lt;BR&gt;&lt;BR&gt;5﹜ Structural characteristics&lt;BR&gt;1. There are DC contacts specifically designed to control the closing and opening coils of DC 220V or 110V, with a breaking current of up to DC220V, 3A;&lt;BR&gt;2. The contact is a silver alloy bridge type double break point structure, which has the advantages of reliable connection and anti-oxidation and corrosion resistance compared to existing auxiliary switches;&lt;BR&gt;3. Various delay contacts can be made, and users need to provide clear technical requirements;&lt;BR&gt;4. This series of auxiliary switches has the advantages of simple structure, easy use, and long service life, making it an ideal replacement product for miniaturization of mechanisms.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241123095451533.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 684px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F13 series AC/DC auxiliary switches&quot; src=&quot;/upload2024/202411/20241123095451533.jpg&quot; width=680 height=684&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F12 series AC/DC auxiliary switch </title>
           <link>http://www.91way.com/info_en/28035.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:43:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;I. Overview&lt;BR&gt;The F12 series auxiliary switch is one of the supporting components for the high-voltage switch operating mechanism. Applicable to the control of closing and opening of high-voltage switch spring mechanisms, as well as the indication of interlocking signals.&lt;BR&gt;&lt;BR&gt;Key Features:&lt;BR&gt;1. There are DC contacts specifically designed to control the closing and opening coils of DC 220V or 110V, with a breaking current of up to 10A when the current is DC220V.&lt;BR&gt;2. The contact is a silver alloy bridge type double break point structure, which has the advantages of reliable connection and anti-oxidation and corrosion resistance compared to existing auxiliary switches.&lt;BR&gt;3. This series of auxiliary switches has the advantages of simple structure, easy use, and long service life, making it an ideal replacement product.&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. Environmental air temperature: -40 ⊥~+40 ⊥;&lt;BR&gt;2. The installation location shall not exceed an altitude of 2000m;&lt;BR&gt;3. The conditions are as follows: the average relative humidity measured within 24 hours shall not exceed 95%; The average water vapor pressure measured within 24 hours shall not exceed 2.2 kPa; The average monthly relative humidity does not exceed 90%; The average monthly water vapor pressure shall not exceed 1.8kPa, taking into account the condensation that may occur on the surface of the product due to temperature changes;&lt;BR&gt;4. Acceleration not exceeding 15m/&amp;sup2;;&lt;BR&gt;5. The air is not significantly polluted by dust, smoke, corrosive and flammable gases, steam, or salt spray.&lt;BR&gt;&lt;BR&gt;5﹜ Structural characteristics&lt;BR&gt;1. The contact is a bridge double break structure, and the contact material is AgNilo;&lt;BR&gt;2. The switch contacts can be equipped with permanent magnet arc extinguishing, and the quantity can be made according to user requirements;&lt;BR&gt;3. Various delay contacts can be made, and users need to provide clear technical requirements.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202411/20241123095144845.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 495px; WIDTH: 597px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of F12 series AC/DC auxiliary switch&quot; src=&quot;/upload2024/202411/20241123095144845.jpg&quot; width=597 height=495&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F11-Y series delayed quick action auxiliary switch </title>
           <link>http://www.91way.com/info_en/27794.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:58</pubDate>
           <comments></comments>
           <description>&lt;P&gt;1﹜ Purpose and Characteristics&lt;BR&gt;The opening and closing time (metal short-circuit time) of high-voltage circuit breakers is a key time parameter that affects the breaking capacity of circuit breakers, and there is still no good solution at home and abroad. The F11-Y delayed quick action auxiliary switch with delayed closing contacts solves the problem of circuit breaker opening and closing time, with a simple and reliable principle. Complies with the requirement of improving auxiliary switches to enable circuit breakers to have &quot;self-defense function&quot; in the power system. The F11 auxiliary switch has universal applicability to hydraulic/pneumatic mechanisms and is currently an optimal and practical solution.&lt;BR&gt;&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;a﹜ Surrounding air temperature: -40 ⊥~+40 ⊥;&lt;BR&gt;b﹜ Altitude: The installation location shall not exceed an altitude of 3000m;&lt;BR&gt;c﹜ The humidity conditions are as follows: the average relative humidity measured within 24 hours shall not exceed 95%; The average value of water vapor pressure measured within 24 hours shall not exceed 2.2KPa; The average monthly relative humidity does not exceed 90%; The average monthly water vapor pressure shall not exceed 1.8KPa;&lt;BR&gt;d﹜ Vibration acceleration not exceeding 15m/s &amp;sup2;;&lt;BR&gt;e﹜ The surrounding air is not significantly polluted by dust, smoke, corrosive and flammable gases, vapors, or salt spray.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145524752.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 437px; WIDTH: 619px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F11-Y series delayed quick action auxiliary switch technical parameters&quot; src=&quot;/upload2023/202304/20230401145524752.jpg&quot; width=619 height=437&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145530854.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 520px; WIDTH: 624px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F11-Y series delay quick action auxiliary switch&quot; src=&quot;/upload2023/202304/20230401145530854.jpg&quot; width=624 height=520&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145538211.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 776px; WIDTH: 618px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Structure diagram&quot; src=&quot;/upload2023/202304/20230401145538211.jpg&quot; width=618 height=776&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145546331.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 593px; WIDTH: 622px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Schematic diagram of F11-Y series delayed quick action auxiliary switch&quot; src=&quot;/upload2023/202304/20230401145546331.jpg&quot; width=622 height=593&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/27793.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The F10 series auxiliary switch is one of the supporting components of high-voltage switchgear. Suitable for controlling the closing, opening, interlocking, and signal circuits of various high-voltage switch operating mechanisms, and can also be used as a conversion or combination switch.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145030855.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 701px; WIDTH: 617px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of F10 series auxiliary switch&quot; src=&quot;/upload2023/202304/20230401145030855.jpg&quot; width=617 height=701&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2023/202304/20230401145044339.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 439px; WIDTH: 591px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F10 series auxiliary switch&quot; src=&quot;/upload2023/202304/20230401145044339.jpg&quot; width=591 height=439&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F5-10II type auxiliary switch </title>
           <link>http://www.91way.com/info_en/18233.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:41</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;The F5-10II auxiliary switch is mainly used for controlling the closing, opening, interlocking, and signal in the control circuit of various high-voltage circuit breakers and high-voltage isolating switches. It can also be used as a conversion switch or combination switch.&lt;BR&gt;&lt;BR&gt;2﹜ Service conditions for F5-10II auxiliary switch&lt;BR&gt;1. Altitude not exceeding 3000 meters;&lt;BR&gt;2. The ambient temperature ranges from -40 ⊥ to+40 ⊥;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The vibration acceleration shall not exceed 15 meters per second;&lt;BR&gt;5. There is no explosion hazard, fire, dust, insulation damage, or corrosive metal gas in the surrounding medium.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F2-1 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/18232.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:33</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;The F2-1 auxiliary switch is mainly used for controlling the closing, opening, interlocking, and signal in the control circuit of various high-voltage circuit breakers and high-voltage isolating switches. It can also be used as a conversion switch or combination switch.&lt;BR&gt;&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. Altitude not exceeding 3000 meters;&lt;BR&gt;2. The ambient temperature ranges from -40 ⊥ to+40 ⊥;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The vibration acceleration shall not exceed 15 meters per second;&lt;BR&gt;5. There is no explosion hazard, fire, dust, insulation damage, or corrosive metal gas in the surrounding medium.&lt;BR&gt;&lt;BR&gt;3﹜ Technical parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~110&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;
&lt;TD align=center&gt;-110V&lt;/TD&gt;
&lt;TD align=center&gt;12.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~220&lt;/TD&gt;
&lt;TD align=center&gt;5A&lt;/TD&gt;
&lt;TD align=center&gt;-220V&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;model&lt;/TD&gt;
&lt;TD align=center&gt;F2-1&lt;/TD&gt;
&lt;TD align=center&gt;F2-2&lt;/TD&gt;
&lt;TD align=center&gt;F2-4&lt;/TD&gt;
&lt;TD align=center&gt;F2-6&lt;/TD&gt;
&lt;TD align=center&gt;F2-8&lt;/TD&gt;
&lt;TD align=center&gt;F2-10&lt;/TD&gt;
&lt;TD align=center&gt;F2-12&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;fifty-five&lt;/TD&gt;
&lt;TD align=center&gt;seventy&lt;/TD&gt;
&lt;TD align=center&gt;one hundred&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and ninety&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;thirty-nine&lt;/TD&gt;
&lt;TD align=center&gt;fifty-four&lt;/TD&gt;
&lt;TD align=center&gt;eighty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fourteen&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-four&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4﹜ Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201202/20120215083036714.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 232px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F2-1 auxiliary switch appearance and installation dimensions&quot; src=&quot;/upload2012/201202/20120215083036714.jpg&quot; width=550 height=232&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F1-6 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/18231.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:24</pubDate>
           <comments></comments>
           <description>Technical parameters of F1-6 auxiliary switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~110&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;
&lt;TD align=center&gt;-110V&lt;/TD&gt;
&lt;TD align=center&gt;12.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~220&lt;/TD&gt;
&lt;TD align=center&gt;5A&lt;/TD&gt;
&lt;TD align=center&gt;-220V&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F1-4 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/18230.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:15</pubDate>
           <comments></comments>
           <description>1﹜ Main purpose&lt;BR&gt;The F1-4 auxiliary switch is mainly used in operating mechanisms such as high-voltage circuit breakers, high and low isolation switches, low-voltage air switches, and low-voltage knife switches. It is used as an auxiliary electrical device to connect or disconnect signal control measurement, protection, and interlocking line devices.&lt;BR&gt;&lt;BR&gt;2﹜ Applicable working conditions:&lt;BR&gt;1. The temperature of the surrounding medium is not higher than+40 ⊥ and not lower than -40 ⊥&lt;BR&gt;2. Altitude not exceeding 3000 meters&lt;BR&gt;3. At a temperature of+25 ⊥, the relative humidity of the air should not exceed 90%&lt;BR&gt;4. In places without severe vibration and oscillation&lt;BR&gt;5. A gas environment with no explosion hazard, no conductive dust, no damage to insulation, and no corrosion of metals in the surrounding medium.&lt;BR&gt;&lt;BR&gt;3﹜ Structural form:&lt;BR&gt;1. F1 can adjust the rotation angle of the center moving contact according to different requirements, which can be divided into 60 &#176;~90 &#176;~120 &#176;&lt;BR&gt;2. F1 can be divided into horizontal and vertical installation methods, and into horizontal with fast mechanism and direct drive and delay contact according to structure.&lt;BR&gt;&lt;BR&gt;4﹜ Technical parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~110&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;
&lt;TD align=center&gt;-110V&lt;/TD&gt;
&lt;TD align=center&gt;12.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~220&lt;/TD&gt;
&lt;TD align=center&gt;5A&lt;/TD&gt;
&lt;TD align=center&gt;-220V&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1 heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;model&lt;/TD&gt;
&lt;TD align=center&gt;F1-1&lt;/TD&gt;
&lt;TD align=center&gt;F1-2&lt;/TD&gt;
&lt;TD align=center&gt;F1-4&lt;/TD&gt;
&lt;TD align=center&gt;F1-6&lt;/TD&gt;
&lt;TD align=center&gt;F1-8&lt;/TD&gt;
&lt;TD align=center&gt;F1-10&lt;/TD&gt;
&lt;TD align=center&gt;F1-12&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;sixty-eight&lt;/TD&gt;
&lt;TD align=center&gt;eighty-three&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and thirteen&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty-three&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-three&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and three&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and thirty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;thirty-nine&lt;/TD&gt;
&lt;TD align=center&gt;fifty-four&lt;/TD&gt;
&lt;TD align=center&gt;eighty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fourteen&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-four&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5﹜ Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201202/20120215071220481.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 250px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F1-4 auxiliary switch appearance and installation dimensions&quot; src=&quot;/upload2012/201202/20120215071220481.jpg&quot; width=550 height=250&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F1-2 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/18229.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:42:07</pubDate>
           <comments></comments>
           <description>1﹜ Main purpose&lt;BR&gt;In operating mechanisms such as high-voltage circuit breakers, high and low isolation switches, low-voltage air switches, and low-voltage knife switches, they are used as auxiliary electrical appliances to connect or disconnect signal control, measurement, protection, and interlocking circuit breakers.&lt;BR&gt;&lt;BR&gt;2﹜ Applicable working conditions:&lt;BR&gt;1. The temperature of the surrounding medium is not higher than+40 ⊥ and not lower than -40 ⊥&lt;BR&gt;2. Altitude not exceeding 3000 meters&lt;BR&gt;3. At a temperature of+25 ⊥, the relative humidity of the air should not exceed 90%&lt;BR&gt;4. In places without severe vibration and oscillation&lt;BR&gt;5. A gas environment with no explosion hazard, no conductive dust, no damage to insulation, and no corrosion of metals in the surrounding medium.&lt;BR&gt;&lt;BR&gt;3﹜ F1-2 auxiliary switch structure form:&lt;BR&gt;1. F1 can adjust the rotation angle of the center moving contact according to different requirements, which can be divided into 60 &#176;~90 &#176;~120 &#176;&lt;BR&gt;2. F1 can be divided into horizontal and vertical installation methods, and into horizontal with fast mechanism and direct drive and delay contact according to structure.&lt;BR&gt;&lt;BR&gt;4﹜ Technical parameters of F1-2 auxiliary switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;
&lt;TD align=center&gt;rated voltage&lt;/TD&gt;
&lt;TD align=center&gt;rated current&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~110&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;
&lt;TD align=center&gt;-110V&lt;/TD&gt;
&lt;TD align=center&gt;12.5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;~220&lt;/TD&gt;
&lt;TD align=center&gt;5A&lt;/TD&gt;
&lt;TD align=center&gt;-220V&lt;/TD&gt;
&lt;TD align=center&gt;10A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Permanent magnet operating mechanism]ZW32-12/A Permanent Magnet Operating Mechanism </title>
           <link>http://www.91way.com/info_en/3820.html</link>
           <author></author>
           <guid></guid>
           <category>Permanent magnet operating mechanism</category>
           <pubDate>2026-6-16 20:42:01</pubDate>
           <comments></comments>
           <description>YZW32 permanent magnet operating mechanism (for ZW32-12/A intelligent integrated circuit breaker)&lt;BR&gt;&lt;BR&gt;ZW32-12/A intelligent integrated vacuum circuit breaker adopts advanced and reliable permanent magnet operating mechanism. The institution utilizes a steady-state magnetic circuit system, which drives the iron core to move to the corresponding limit position using excitation coils, and uses the magnetic field energy provided by high-performance permanent magnets to keep it at the limit position. Stimulating one of the excitation coils to generate a driving force greater than the remaining holding force can activate the moving iron core of the permanent magnet mechanism. The permanent magnet actuator eliminates the mechanical devices such as energy storage and locking that are vulnerable to traditional mechanisms, simplifies the structure, reduces the number of parts by more than 70% compared to traditional mechanisms, simplifies assembly, and greatly improves the reliability and lifespan of the mechanism. At the same time, due to the use of capacitors as the operating power supply, it also avoids the influence of auxiliary power supply fluctuations on the characteristics of the mechanism. The high-performance permanent magnet operating mechanism can operate frequently for a long time, with a lifespan of up to 100000 times and truly achieving permanent maintenance free operation.&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions of YZW32 permanent magnet actuator (for ZW32-12/A intelligent integrated circuit breaker) 
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200806/20086118417133.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 739px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Structural diagram of permanent magnet operating mechanism (for ZW32-12/A intelligent integrated circuit breaker)&quot; src=&quot;/uploadfiles/200806/20086118417133.jpg&quot; width=600 height=739&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Note: If the user has special requirements, they can be determined through negotiation.&lt;BR&gt;Permanent magnet operating mechanism (for ZW32-12/A intelligent integrated circuit breaker)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]FLF10 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/16155.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:58</pubDate>
           <comments></comments>
           <description>The FLF10 series auxiliary switch is a domestically produced new product based on international standards, and is one of the supporting components for high-voltage switchgear in the power industry. It is widely used to control various secondary circuits such as closing, opening, interlocking, and signal circuits of high-voltage switch operating mechanisms.&lt;BR&gt;&lt;BR&gt;The FLF10 series auxiliary switch is mainly used for vacuum switches such as ZN series, spring operated mechanisms such as CT series, isolation switches, etc. It can also be used as a conversion or combination switch.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9-36I/W type auxiliary switch </title>
           <link>http://www.91way.com/info_en/8360.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:47</pubDate>
           <comments></comments>
           <description>The F9-36I/W auxiliary switch is suitable for controlling the closing, opening, interlocking, and signal circuits of high-voltage switch operating mechanisms, as well as various high-voltage switch cabinets. It can also be used as a conversion or combination switch.&lt;BR&gt;&lt;BR&gt;2﹜ Usage conditions:&lt;BR&gt;1. Altitude not exceeding 3000M;&lt;BR&gt;The temperature of the surrounding medium should not exceed+40 ⊥ and should not be lower than -40 ⊥;&lt;BR&gt;At a temperature of 25 ⊥, the relative humidity of the air should not exceed 90%;&lt;BR&gt;4. Vibration acceleration not exceeding 15m/s2;&lt;BR&gt;There is no explosion hazard in the surrounding medium, no conductive dust, no damage to insulation, and no gas environment that can corrode metals&lt;BR&gt;&lt;BR&gt;3﹜ Model meaning:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911385418492.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 350px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9-36I/W auxiliary switch model description&quot; src=&quot;/upload2009/200911/200911385418492.jpg&quot; width=350 height=200&gt;&lt;/A&gt;&lt;BR&gt;Note: 1. A pair of contacts form one circuit; 2. Each section of the delay contact only contains one pair of contacts, and the delay time for the CD10 mechanism is 20MS&lt;BR&gt;&lt;BR&gt;4﹜ Basic parameters (see Table 1)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=175 colSpan=3&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;Load nature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;numerical value&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=142 colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=33&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=251&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;DC 48110220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;Communication 110220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142 colSpan=2&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=67&gt;
&lt;DIV align=center&gt;Rated breaking current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;DC 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;I=20ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;DC 110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;I=20ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;AC 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;COS耳=0.4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5﹜ Institution and characteristics:&lt;BR&gt;The F9 series auxiliary switch is composed of multiple sections, and its internal structure is shown in Figure 1. There are labels on both sides above each section indicating the number of this contact. The diagonal lines in the same section form a pair of normally open (or normally closed) circuits, and the determination of normally open (or normally closed) is displayed by the indicator on the operating shaft. The indicator points to a set of contact limits, indicating that this set is a reliable pair of normally closed contacts (circuits), and the rest are a pair of normally open contacts.&lt;BR&gt;&lt;BR&gt;The contact between the dynamic and static contacts of this series of auxiliary switches is made by a circular sliding crimping method. The pressure between the hoes is generated by a separately set compression spring, which is non-conductive and far away from the heating part. The movable hinge joint of the static contact is connected by bare copper wire welding, making the current performance more reliable&lt;BR&gt;The delayed quick action mechanism is flexible in operation, precise in timing, and switches quickly. The quick action mechanism only starts to drive the moving contact to rotate quickly after the active arm rotates to 65 &#176; -75 &#176; until the end point, and can reliably stay at the end position. Therefore, it meets the requirements of delay and quick action.&lt;BR&gt;&lt;BR&gt;6﹜ Appearance and installation dimensions (see figure)&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/200911385535857.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 300px; WIDTH: 350px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9-36I/W type auxiliary switch external dimensions&quot; src=&quot;/upload2009/200911/200911385535857.jpg&quot; width=350 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/200911385545442.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 300px; WIDTH: 350px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F9-36I/W auxiliary switch&quot; src=&quot;/upload2009/200911/200911385545442.jpg&quot; width=350 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZFK6-8I/L Vacuum auxiliary switch </title>
           <link>http://www.91way.com/info_en/8359.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:38</pubDate>
           <comments></comments>
           <description>ZFK6-8I/L vacuum auxiliary switch is suitable for controlling the closing, opening, interlocking, signal circuit of high-voltage switch operating mechanism and various high-voltage switchgear. It can also be used as a conversion or combination switch, as a substitute for mechanical or auxiliary switches.&lt;BR&gt;&lt;BR&gt;1. Product Overview:&lt;BR&gt;At present, the F series auxiliary switches used in domestic isolation switches and other electrical appliances adopt mechanical friction contact type, which generally has problems such as unreliable contact, poor environmental adaptability, low protection level, and short service life. To solve these problems, our factory has developed a novel ZFK6 series vacuum auxiliary switch by replacing mechanical contacts with vacuum reed switches. Its high on/off reliability, 100000 contact life, maintenance free performance, and good compatibility make it the preferred product to replace F-series auxiliary switches. It is widely used in relay switching circuits and signal acquisition circuits, and is suitable for protection circuits, electromagnetic lock circuits, isolation switch auxiliary circuits, and circuit breaker secondary control intermediate circuits.&lt;BR&gt;&lt;BR&gt;2. Structure and performance characteristics:&lt;BR&gt;The ZFK6 series vacuum assisted switch adopts the same appearance and size to achieve full compatibility.&lt;BR&gt;The core components of the ZFK6 series switch are sealed as a whole to enhance reliability, and the rotor of its moving part is installed with permanent magnetic steel. Placed on the fixed plate, it does not generate friction with the fixed plate, so the rotation of the shaft is light and flexible, and there is no mechanical jamming.&lt;BR&gt;The head of the switch adopts a quick action mechanism. When the shaft rotates to 75 &#176;, under the action of the energy storage spring, the movable block drives the rotor to move quickly and reliably stay at the end position. The wiring terminal adopts composite slot combination screws, and the pressure washer automatically rises and falls with the tightening and loosening of the screws, making wiring convenient.&lt;BR&gt;Compared with the commonly used F-series mechanical contact auxiliary switches in China, the ZFK6 series vacuum auxiliary switch has a series of advantages:&lt;BR&gt;Adaptable&lt;BR&gt;Mechanical contact switches can quickly experience poor contact due to corner corrosion in corrosive environments. The contacts of ZFK6 series switches are sealed in vacuum tubes, ensuring good on/off performance even in dusty, humid, and corrosive environments. In addition, considering the need for users to replace old switches and adapt to various installation scenarios, the ZFK6 series vacuum switches have taken into account different installation methods, rotation angles, and center height requirements. Except for the main and auxiliary nodding of the circuit breaker, it can replace all auxiliary switches of the F series.&lt;BR&gt;Long lifespan, anti-interference&lt;BR&gt;The lifespan of the vacuum tube of the ZFK6 series switch is 2 &#215; 104 analysis times, which is much higher than the 20000 times of mechanical contacts; The permanent magnetic steel that controls the on/off of the switch is made of rare earth magnetic materials, which have strong magnetism and never demagnetize. The structure of the switch itself can effectively resist various magnetic and electric field interferences.&lt;BR&gt;High strength, no need for maintenance&lt;BR&gt;The components of the F series switch are relatively scattered and require frequent maintenance due to their inherent unreliability. The ZFK6 series switch seals the core components vacuum and connecting copper sheets with epoxy resin in a fixed plate, which has high mechanical strength and fundamentally eliminates the possibility of unreliable contact, saving the trouble of frequent maintenance.&lt;BR&gt;High reliability of electrical contact&lt;BR&gt;In the past, the on/off of F series switch contacts was achieved through mechanical friction contact. The arc produced causes the contact surface to burn black, seriously affecting the contact reliability. However, the contacts of ZFK6 series switches work in vacuum or inert gas media, and do not generate arcs under specified currents, ensuring good electrical contact reliability.&lt;BR&gt;&lt;BR&gt;3. Technical parameters and usage conditions of ZFK6-8I/L vacuum assisted switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=114&gt;
&lt;DIV&gt;Voltage at both ends of the contact V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=227 colSpan=2&gt;
&lt;DIV align=center&gt;communication&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=227 colSpan=2&gt;
&lt;DIV align=center&gt;direct&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Maximum breaking current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;2.5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;4A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Maximum closing current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Breakdown voltage between contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;700V DC&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Contact resistance of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;100m次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;insulation resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;1000M次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;2500V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;electrical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;2 &#215; 104 times&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Protection level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;IP55&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;Anti-interference performance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;The smooth and reliable connection is not affected by interference from common mode, differential mode, radiated electromagnetic fields, and electrostatic fields&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;ambient temperature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;ㄗ-40~+40ㄘ⊥&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=114&gt;
&lt;DIV align=center&gt;environmental conditions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;DIV align=center&gt;Relative humidity not exceeding 95%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F8 Auxiliary contact group </title>
           <link>http://www.91way.com/info_en/5640.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:30</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200942423732331.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 800px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F8 Auxiliary Contact Group Model Description&quot; src=&quot;/uploadfiles/200904/200942423732331.gif&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094242389165.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 700px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of F8 auxiliary contact group&quot; src=&quot;/uploadfiles/200904/20094242389165.gif&quot; width=680 height=700&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942423832929.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 840px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of F8 auxiliary contact group&quot; src=&quot;/uploadfiles/200904/200942423832929.gif&quot; width=680 height=840&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/20094242396518.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 800px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F8 auxiliary contact group&quot; src=&quot;/uploadfiles/200904/20094242396518.gif&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200904/200942423927968.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 900px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F8 auxiliary contact group contact diagram&quot; src=&quot;/uploadfiles/200904/200942423927968.gif&quot; width=680 height=900&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;F8 auxiliary contact group&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF6↓-↓/Z-↓ Series Vacuum Auxiliary Switches </title>
           <link>http://www.91way.com/info_en/5510.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:21</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;ZKF6 ↓ - ↓/Z - ↓ series vacuum auxiliary switch&lt;BR&gt;&lt;BR&gt;Voltage: AC220V~110V&lt;BR&gt;Rated current: 5A&lt;/P&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/200941616841850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 808px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF6 ↓ - ↓/Z - ↓ series vacuum auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200904/200941616841850.jpg&quot; width=400 height=808&gt;&lt;/A&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF6↓-↓/W1(W2)-↓ Series Vacuum Auxiliary Switches </title>
           <link>http://www.91way.com/info_en/5509.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:12</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/200941616546671.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 671px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF6 ↓ - ↓/W1 (W2) - ↓ Series Vacuum Auxiliary Switch Appearance and Installation Dimensions&quot; src=&quot;/uploadfiles/200904/200941616546671.jpg&quot; width=400 height=671&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKF6 ↓ - ↓/W1 (W2) - ↓ series vacuum auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF1↓-↓/W2-↓ Series Vacuum Auxiliary Switches </title>
           <link>http://www.91way.com/info_en/5508.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:41:04</pubDate>
           <comments></comments>
           <description>Fixed voltage: AC220V~110V 
&lt;DIV&gt;Rated current: 5A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200941616433858.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 685px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF1 ↓ - ↓/W2- ↓ series vacuum auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/200941616433858.jpg&quot; width=400 height=685&gt;&lt;/A&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;BR&gt;ZKF1 ↓ - ↓/W2- ↓ series vacuum auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-↓I/L series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5507.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;F4- ↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V&lt;BR&gt;Rated current: 10A&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/200941616028120.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 712px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F4- ↓ I/L series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/200941616028120.jpg&quot; width=400 height=712&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;F4- ↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9.F10.F11-↓I/L series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5506.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:47</pubDate>
           <comments></comments>
           <description>F9.F10.F11-↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V 
&lt;DIV&gt;Rated current: 12.5A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009416155140874.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 713px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9.F10.F11- ↓ I/L series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/2009416155140874.jpg&quot; width=400 height=713&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;F9.F10.F11-↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-12III/W type auxiliary switch </title>
           <link>http://www.91way.com/info_en/5505.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:38</pubDate>
           <comments></comments>
           <description>F6-12III/W type auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V
&lt;DIV&gt;Rated current: 12.5A&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009416154357525.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 689px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F6-12III/W auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200904/2009416154357525.jpg&quot; width=400 height=689&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Normally open and normally closed logarithm&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;
&lt;TD align=center&gt;ten&lt;/TD&gt;
&lt;TD align=center&gt;eleven&lt;/TD&gt;
&lt;TD align=center&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Number of partition sections&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;
&lt;TD align=center&gt;ten&lt;/TD&gt;
&lt;TD align=center&gt;eleven&lt;/TD&gt;
&lt;TD align=center&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;eighty-six&lt;/TD&gt;
&lt;TD align=center&gt;ninety-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and ten&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and twenty-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and thirty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty-six&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifty-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and eighty-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and ninety-four&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;fifty-six&lt;/TD&gt;
&lt;TD align=center&gt;sixty-eight&lt;/TD&gt;
&lt;TD align=center&gt;eighty&lt;/TD&gt;
&lt;TD align=center&gt;ninety-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and sixteen&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and twenty-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifty-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and sixty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;F6- ↓ III/W series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-↓II/W1 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5504.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:30</pubDate>
           <comments></comments>
           <description>F6- ↓ II/W1 series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V 
&lt;DIV&gt;Rated current: 12.5A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009416154124524.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 773px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F6- ↓ II/W1 series auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200904/2009416154124524.jpg&quot; width=400 height=773&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;F6- ↓ II/W1 series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F5-↓II/W1 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5503.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:22</pubDate>
           <comments></comments>
           <description>F5-↓II/W1 series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V 
&lt;DIV&gt;Rated current: 10A&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009416153828287.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 769px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F5- ↓﹡/W1 series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/2009416153828287.jpg&quot; width=400 height=769&gt;&lt;/A&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-4I/L type auxiliary switch </title>
           <link>http://www.91way.com/info_en/5502.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:13</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;The F4-4I/L-type auxiliary switch is mainly used for controlling the closing, opening, interlocking, and signal in the control circuit of various high-voltage circuit breakers and high-voltage isolating switches. It can also be used as a conversion switch or combination switch.&lt;BR&gt;&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. Altitude not exceeding 3000 meters;&lt;BR&gt;2. The ambient temperature ranges from -40 ⊥ to+40 ⊥;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The vibration acceleration shall not exceed 15 meters per second;&lt;BR&gt;5. There is no explosion hazard, fire, dust, insulation damage, or corrosive metal gas in the surrounding medium.&lt;BR&gt;&lt;BR&gt;3﹜ Technical parameters:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Normally open and normally closed logarithm&lt;/TD&gt;
&lt;TD align=center&gt;one&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Number of partition sections&lt;/TD&gt;
&lt;TD align=center&gt;one&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;eighty-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and six&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and twenty-four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and ninety-six&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and fourteen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;4﹜ Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120215064451675.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 270px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F4-4I/L-type auxiliary switch external dimensions&quot; src=&quot;/upload2012/201202/20120215064451675.jpg&quot; width=550 height=270&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9.F10.F11-↓III/L series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5501.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:40:05</pubDate>
           <comments></comments>
           <description>F9.F10.F11-↓ III/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V 
&lt;DIV&gt;Rated current: 10A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/2009416153323154.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 698px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9.F10.F11- ↓ III/L series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/2009416153323154.jpg&quot; width=400 height=698&gt;&lt;/A&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9.F10.F11-↓I/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/5500.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:57</pubDate>
           <comments></comments>
           <description>F9.F10.F11-↓ I/W series auxiliary switch&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V~220V 
&lt;DIV&gt;Rated current: 10A&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009416153151693.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 728px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9.F10.F11- ↓ I/W series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200904/2009416153151693.jpg&quot; width=400 height=728&gt;&lt;/A&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-↓II/W2 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/4551.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:48</pubDate>
           <comments></comments>
           <description>The F10- ↓ II/W2 series auxiliary switch is a domestically produced product developed with the introduction of technology from Siemens AG in Germany. It is suitable for controlling various secondary circuits such as closing, opening, interlocking, and signal circuits of high-voltage switch operating mechanisms. Widely used in vacuum circuit breakers and spring operated mechanisms such as VS1 (ZN63), Zn12, 3AF, ZN65, CT19, CT ↓, and can also be used as transfer switches and combination switches.&lt;BR&gt;&lt;BR&gt;The performance of F10- ↓ II/W2 series auxiliary switches meets the requirements of GB3906-9 &quot;3-35KV AC Metal Enclosed Switchgear&quot; and Q/XK005-1999 &quot;Technical Conditions&quot; for this product.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF6 type vacuum assisted switch </title>
           <link>http://www.91way.com/info_en/4320.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200808/2008819135013603.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 300px; WIDTH: 678px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF6 vacuum auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200808/2008819135013603.jpg&quot; width=678 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/2008819135025336.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 260px; WIDTH: 678px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical Description of ZKF6 Vacuum Auxiliary Switch&quot; src=&quot;/uploadfiles/200808/2008819135025336.jpg&quot; width=678 height=260&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/2008819135037583.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 230px; WIDTH: 678px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF6 vacuum auxiliary switch contact diagram and installation dimensions&quot; src=&quot;/uploadfiles/200808/2008819135037583.jpg&quot; width=678 height=230&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;ZKF6 vacuum auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-12C/W Rotary auxiliary switch F10-4C/W F10-8C/W F10-12C/W</title>
           <link>http://www.91way.com/info_en/3855.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:31</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;F10-12C/W rotary auxiliary switch&lt;BR&gt;Specifications:&lt;BR&gt;Can be composed of 2 open 2 closed, 3 open 3 closed, 4 open 4 closed, 6 open 6 closed, 8 open 8 closed&lt;BR&gt;There are various contact forms such as 10 open and 10 closed, 11 open and 11 closed, 12 open and 12 closed, etc.&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200806/200862203316854.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 208px; WIDTH: 200px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of F10-12C/W rotary auxiliary switch&quot; src=&quot;/uploadfiles/200806/200862203316854.jpg&quot; width=200 height=208&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200806/200862203323244.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 190px; WIDTH: 200px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of F10-12C/W Rotary Auxiliary Switch&quot; src=&quot;/uploadfiles/200806/200862203323244.jpg&quot; width=200 height=190&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;F10-12C/W rotary auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]NK-047 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3541.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of NK-047 series auxiliary switch:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V-220V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;NK-047 series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008516225255150.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 477px; WIDTH: 372px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of NK-047 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516225255150.jpg&quot; width=372 height=477&gt;&lt;/A&gt;&lt;BR&gt;NK-047 series auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]NK-045 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3540.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:14</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of NK-045 series auxiliary switch:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V-220V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;NK-045 series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008516225030764.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 591px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of NK-045 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516225030764.jpg&quot; width=550 height=591&gt;&lt;/A&gt;&lt;BR&gt;NK-045 series auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]NK-052 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3539.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:39:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of NK-052 series auxiliary switch:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC380V-220V-24V&lt;BR&gt;Rated voltage: 10A&lt;BR&gt;&lt;BR&gt;NK-052 series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008516224549917.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 369px; WIDTH: 432px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of NK-052 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516224549917.jpg&quot; width=432 height=369&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;NK-052 series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]NK-050 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3538.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:57</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC660V-380V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;NK-050 series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008516224315203.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 476px; WIDTH: 419px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of NK-050 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516224315203.jpg&quot; width=419 height=476&gt;&lt;/A&gt;&lt;BR&gt;NK-050 series auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]NK-030 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3537.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:45</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview:&lt;BR&gt;&lt;BR&gt;Suitable for CJ12, CJ24, various anti riot vacuum contactors, etc&lt;BR&gt;&lt;BR&gt;Technical parameters of NK-030 series auxiliary switch:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC660V-220V&lt;BR&gt;Rated current: 15A&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200805/2008516223957509.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 400px; WIDTH: 298px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of NK-030 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516223957509.jpg&quot; width=298 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;NK-030 series auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F11 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/3536.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:36</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008516223446709.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1712px; WIDTH: 670px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline dimensions and technical parameters of F11 series auxiliary switch&quot; src=&quot;/uploadfiles/200805/2008516223446709.gif&quot; width=670 height=1712&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;F11 series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKFG series vacuum assisted switch </title>
           <link>http://www.91way.com/info_en/2301.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:28</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKFG series vacuum auxiliary switch is suitable for controlling the closing, opening, interlocking, and signal circuits of high-voltage switch operating mechanisms, as well as various high-voltage switch cabinets. It can also be used as a conversion or combination switch. As an alternative to mechanical friction contact auxiliary switches.&lt;BR&gt;&lt;BR&gt;Product model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/20075209338324.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 141px; WIDTH: 338px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKFG series vacuum assisted switch model description&quot; src=&quot;/uploadfiles/200705/20075209338324.gif&quot; width=338 height=141&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Terms of Use&lt;BR&gt;1. The temperature of the surrounding medium shall not exceed+60 ⊥ and shall not be lower than -30 ⊥; At a temperature of 25 ⊥, the relative humidity of the air should not exceed 90%;&lt;BR&gt;2. There is no explosion hazard in the surrounding medium, no conductive dust, no damage to insulation, and no gas environment that can corrode metals.&lt;BR&gt;&lt;BR&gt;ZKFG series vacuum assisted switch technical parameters&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200705/20075209347870.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 90px; WIDTH: 300px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKFG series vacuum assisted switch technical parameters&quot; src=&quot;/uploadfiles/200705/20075209347870.gif&quot; width=300 height=90&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Structure and Characteristics&lt;BR&gt;The ZKFG series vacuum assisted switch and the F series switch adopt the same appearance and size to achieve comprehensive compatibility.&lt;BR&gt;&lt;BR&gt;ZKFG1 and F1 switches have the same appearance; ZKFG2 is consistent with F6 switch. The core component of the ZKFG series vacuum assisted switch adopts a vacuum reed switch instead of mechanical contacts, which has extremely high on/off reliability and maintenance free performance; The core components are enclosed as a whole, enhancing reliability. Its moving parts - the rotor - are suspended in the fixed disk by the action of a magnetic field, and there is basically no friction with the fixed disk, so the rotating shaft is light and flexible, and there is no mechanical jamming.&lt;BR&gt;The switch head adopts a quick action mechanism. When the shaft rotates to 75 ⊥, it starts to drive the rotor to quickly rotate under the action of the energy storage spring and reliably stays at the end position. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/2191.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:19</pubDate>
           <comments></comments>
           <description>&lt;DIV&gt;The F9 series auxiliary switch is suitable for controlling the closing, opening, interlocking, and signal circuits of high-voltage switch operating mechanisms, as well as various high-voltage switch cabinets. It can also be used as a conversion or combination switch.&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;2﹜ Usage conditions:&lt;/DIV&gt;
&lt;DIV&gt;1. Altitude not exceeding 3000M;&lt;/DIV&gt;
&lt;DIV&gt;The temperature of the surrounding medium should not exceed+40 ⊥ and should not be lower than -40 ⊥;&lt;/DIV&gt;
&lt;DIV&gt;At a temperature of 25 ⊥, the relative humidity of the air should not exceed 90%;&lt;/DIV&gt;
&lt;DIV&gt;4. Vibration acceleration not exceeding 15m/s2;&lt;/DIV&gt;
&lt;DIV&gt;There is no explosion hazard in the surrounding medium, no conductive dust, no damage to insulation, and no gas environment that can corrode metals&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;3﹜ Model meaning:&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;A href=&quot;/uploadfiles/200807/2008713151940824.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 350px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9 series auxiliary switch model description&quot; src=&quot;/uploadfiles/200807/2008713151940824.jpg&quot; width=350 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV&gt;
&lt;DIV&gt;Note: 1. A pair of contacts form one circuit; 2. Each section of the delay contact only contains one pair of contacts, and the delay time for the CD10 mechanism is 20MS&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;4﹜ Basic parameters (see Table 1)&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=175 colSpan=3&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;Load nature&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;numerical value&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=142 colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=33&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=251&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;DC 48110220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;Communication 110220V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142 colSpan=2&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=67&gt;
&lt;DIV align=center&gt;Rated breaking current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;DC 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;I=20ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;DC 110V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;I=20ms&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;AC 220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=251&gt;
&lt;DIV align=center&gt;COS耳=0.4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;5﹜ Institution and characteristics:&lt;/DIV&gt;
&lt;DIV&gt;The F6 series auxiliary switch is composed of multiple sections, and its internal structure is shown in Figure 1. There are labels on both sides above each section indicating the number of this contact. The diagonal lines in the same section form a pair of normally open (or normally closed) circuits, and the determination of normally open (or normally closed) is displayed by the indicator on the operating shaft. The indicator points to a set of contact limits, indicating that this set is a reliable pair of normally closed contacts (circuits), and the rest are a pair of normally open contacts.&lt;/DIV&gt;&lt;/DIV&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200703/20073271622775.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1712px; WIDTH: 670px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9 series auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/200703/20073271622775.gif&quot; width=670 height=1712&gt;&lt;/A&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-4III/LB type auxiliary switch </title>
           <link>http://www.91way.com/info_en/117.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:10</pubDate>
           <comments></comments>
           <description>F10-4III/LB type auxiliary switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-2III/LB type auxiliary switch </title>
           <link>http://www.91way.com/info_en/116.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:38:02</pubDate>
           <comments></comments>
           <description>F10-2III/LB type auxiliary switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-16III/W4 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/115.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:54</pubDate>
           <comments></comments>
           <description>F10-16III/W4 auxiliary switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F10-8III type auxiliary switch </title>
           <link>http://www.91way.com/info_en/114.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:45</pubDate>
           <comments></comments>
           <description>F10-8III auxiliary switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]047 Vacuum auxiliary switch </title>
           <link>http://www.91way.com/info_en/113.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;047 vacuum assist switch&lt;BR&gt;&lt;BR&gt;Overview:&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions of 047 vacuum auxiliary switch:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 477px; WIDTH: 372px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of 047 vacuum assisted switch&quot; src=&quot;/uploadfiles/200610/20061018234345934.jpg&quot; width=372 height=477&gt;&lt;BR&gt;Vacuum auxiliary switch (047)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]045 Vacuum series auxiliary switch </title>
           <link>http://www.91way.com/info_en/112.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:27</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview of 045 Vacuum Series Auxiliary Switch:&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;045 Vacuum Series Auxiliary Switch Appearance and Installation Dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 591px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;045 Vacuum Series Auxiliary Switch Dimensions&quot; src=&quot;/uploadfiles/200610/2006101823424457.jpg&quot; width=550 height=591&gt;&lt;BR&gt;&lt;BR&gt;Vacuum series auxiliary switch (045)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]052 Vacuum series auxiliary switch </title>
           <link>http://www.91way.com/info_en/111.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:18</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 369px; WIDTH: 432px; FILTER: none&quot; border=0 hspace=0 alt=&quot;052 Vacuum Series Auxiliary Switch Dimensions&quot; src=&quot;/uploadfiles/200610/20061018234029943.jpg&quot; width=432 height=369&gt;&lt;BR&gt;Vacuum series auxiliary switch (052)&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]050 Vacuum series auxiliary switch </title>
           <link>http://www.91way.com/info_en/110.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;050 Vacuum Series Auxiliary Switch:&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC660V-380V-24V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 476px; WIDTH: 419px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of 050 Vacuum Series Auxiliary Switch&quot; src=&quot;/uploadfiles/200610/20061018233910412.jpg&quot; width=419 height=476&gt;&lt;BR&gt;&lt;BR&gt;Vacuum series auxiliary switch (050)&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]030 Vacuum series auxiliary switch </title>
           <link>http://www.91way.com/info_en/109.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:37:00</pubDate>
           <comments></comments>
           <description>&lt;P&gt;030 Vacuum Series Auxiliary Switch:&lt;BR&gt;&lt;BR&gt;Vacuum series auxiliary switch (030) is suitable for CJ12, CJ24, various explosion-proof vacuum contactors, etc&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC660V-220V&lt;BR&gt;Rated current: 15A&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 400px; WIDTH: 298px; FILTER: none&quot; border=0 hspace=0 alt=&quot;030 Vacuum Series Auxiliary Switch Dimensions&quot; src=&quot;/uploadfiles/200610/20061018233656749.jpg&quot; width=298 height=400&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]FK series push-pull auxiliary switch </title>
           <link>http://www.91way.com/info_en/108.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:52</pubDate>
           <comments></comments>
           <description>FK series push-pull auxiliary switch technical parameters:&lt;BR&gt;&lt;BR&gt;Rated voltage: AC660V&lt;BR&gt;Rated current: 15A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3 normally open and 2 normally closed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 344px; WIDTH: 475px; FILTER: none&quot; border=0 hspace=0 alt=&quot;FK series push-pull auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/200610/2006101823335442.jpg&quot; width=475 height=344&gt;&lt;BR&gt;&lt;BR&gt;FK series push-pull auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF series auxiliary switch </title>
           <link>http://www.91way.com/info_en/107.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:44</pubDate>
           <comments></comments>
           <description>The ZKF series auxiliary switch adopts the same appearance and size as the F series Tianguan to achieve full compatibility. The external dimensions of ZKF6 switch and F6 new auxiliary switch are completely consistent, with small size and higher reliability.&lt;BR&gt;The core components of the ZKF series switches are sealed as a whole to enhance reliability. The moving part - the rotor - is suspended in the fixed disk by the action of a magnetic field, and there is basically no friction with the fixed disk. Therefore, the rotation of the shaft is light and flexible, and there is no situation of large mechanical jamming.&lt;BR&gt;The head of the switch adopts a quick action mechanism. When the shaft rotates to 75 degrees, under the action of the energy storage spring, the movable block drives the rotor to move quickly and reliably stay at the end position. The wiring terminal adopts composite slot combination screws, and the pressure washer automatically rises and falls with the tightening and loosening of the screws, making wiring convenient.&lt;BR&gt;&lt;BR&gt;The ZKF series auxiliary switch has a series of advantages compared to the F series mechanical contact auxiliary switch commonly used in China recently:&lt;BR&gt;1. High reliability of electrical contact&lt;BR&gt;The on-off of F-series switch contacts is achieved through mechanical friction contact, and the generated arc causes the contact surface to burn black, seriously affecting the contact reliability. The contacts of the ZKF series switches work in vacuum or inert gas, and basically do not generate arcs, ensuring good electrical contact reliability.&lt;BR&gt;2. High mechanical strength, no need for maintenance&lt;BR&gt;The components of mechanical switches are relatively scattered and require frequent maintenance due to their inherent unreliability. The ZKF series switches seal the core components of the vacuum tube and the connecting copper sheet with resin in a silent disc, forming a whole layer. Its mechanical emphasis is high, fundamentally eliminating the possibility of unreliable contact, thus saving the trouble of frequent maintenance.&lt;BR&gt;3. Long lifespan and strong anti-interference ability&lt;BR&gt;The lifespan of the vacuum tube of the ZKF series switch is 100000 times of breaking capacity, far higher than the thousands of times of mechanical contacts. The permanent magnetic steel that controls the on-off of the switch is made of the best magnetic material - neodymium iron boron, which has strong magnetism and never demagnetizes. The structure of the switch itself can effectively resist the interference of various magnetic fields and electric fields.&lt;BR&gt;4. Strong adaptability&lt;BR&gt;The ZKF series switches are not limited by dusty environments due to their sealing properties; Good on/off performance can be ensured even in humid and corrosive environments with a wide temperature range. On the contrary, switches with mechanical contacts quickly experience poor contact due to contact corrosion in corrosive environments.&lt;BR&gt;Considering the need for users to replace old switches and adapt to various installation scenarios, the ZKF series switches have taken into account different installation methods, rotation angles, and center height requirements. It can almost replace all auxiliary switches of the F series.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;L1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated voltage (AC/DC) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated breaking power W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Maximum breaking current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Maximum conduction current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Breakdown voltage between contacts V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Communication&amp;gt;300 (DC&amp;gt;400)&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Contact resistance 次&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Insulation resistance 次&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one thousand and ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1-minute power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Contact lifespan times&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;one hundred and five&lt;/DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Protection level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;IP55&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Anti-interference performance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;The reliability of contact continuity is not affected by the interference of common mode, differential mode, radiated electromagnetic field, and electrostatic field&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Layer combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Any combination of layers 2-8&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Environmental temperature ⊥&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;(-)30-(+)60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;environmental conditions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Relative humidity not exceeding 95%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9-12I/L type auxiliary switch </title>
           <link>http://www.91way.com/info_en/43.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:35</pubDate>
           <comments></comments>
           <description>F9-12I/L-type auxiliary switch is suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 12.5A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;11&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and fourteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;/&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;F9-12I/L-type auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 249px; WIDTH: 512px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9-12I/L-type auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/2006-05/20060531_123431.jpg&quot; width=512 height=249&gt;&lt;BR&gt;&lt;BR&gt;F9- ↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F9-12III/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/42.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:27</pubDate>
           <comments></comments>
           <description>F9-12III/W series auxiliary switches are suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 12.5A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;11&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 248px; WIDTH: 549px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F9-12III/W series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/2006-05/20060531_232120.jpg&quot; width=549 height=248&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-12I/W type auxiliary switch </title>
           <link>http://www.91way.com/info_en/41.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:18</pubDate>
           <comments></comments>
           <description>F6-12I/W auxiliary switch is suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and twenty-one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;F6-12I/W auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 251px; WIDTH: 499px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of F6-12I/W auxiliary switch&quot; src=&quot;/uploadfiles/2006-05/20060531_093131.jpg&quot; width=499 height=251&gt;&lt;BR&gt;&lt;BR&gt;F6-12I/W type auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-12III/L type auxiliary switch </title>
           <link>http://www.91way.com/info_en/33.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:10</pubDate>
           <comments></comments>
           <description>F6-12III/L auxiliary switch is suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 12.5A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Normally open and normally closed logarithm&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;
&lt;TD align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Number of partition sections&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;
&lt;TD align=center&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;eighty-one&lt;/TD&gt;
&lt;TD align=center&gt;ninety-three&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and five&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and twenty-nine&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifty-three&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-seven&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;
&lt;TD align=center&gt;/&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;F6- ↓ III/L series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 246px; WIDTH: 531px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of F6-12III/L auxiliary switch&quot; src=&quot;/uploadfiles/2006-05/20060531_093317.jpg&quot; width=531 height=246&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-12III/W2 type auxiliary switch </title>
           <link>http://www.91way.com/info_en/32.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:36:01</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;F6-12III/W2 auxiliary switch is suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 12.5A&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;sixty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;F6-12III/W2 auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 247px; WIDTH: 517px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F6-12III/W2 type auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/2006-05/20060531_091428.jpg&quot; width=517 height=247&gt;&lt;BR&gt;&lt;BR&gt;F6- ↓ III/W series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F5-8II/W type auxiliary switch </title>
           <link>http://www.91way.com/info_en/28.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:53</pubDate>
           <comments></comments>
           <description>Overview of F5- ↓ II/W1 series auxiliary switches:&lt;BR&gt;Used for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 12.5A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=550 align=center border=1 heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3 open and 2 closed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-seven&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 306px; WIDTH: 535px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F5-8II/W auxiliary switch appearance and installation dimensions&quot; src=&quot;/uploadfiles/2006-05/20060527_120038.jpg&quot; width=535 height=306&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-8III/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/27.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:45</pubDate>
           <comments></comments>
           <description>F4-8III/W series auxiliary switch&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Normally open and normally closed logarithm&lt;/TD&gt;
&lt;TD align=center&gt;one&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;Number of partition sections&lt;/TD&gt;
&lt;TD align=center&gt;one&lt;/TD&gt;
&lt;TD align=center&gt;two&lt;/TD&gt;
&lt;TD align=center&gt;three&lt;/TD&gt;
&lt;TD align=center&gt;four&lt;/TD&gt;
&lt;TD align=center&gt;five&lt;/TD&gt;
&lt;TD align=center&gt;six&lt;/TD&gt;
&lt;TD align=center&gt;seven&lt;/TD&gt;
&lt;TD align=center&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L1(mm)&lt;/TD&gt;
&lt;TD align=center&gt;eighty-two&lt;/TD&gt;
&lt;TD align=center&gt;ninety-seven&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifteen&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and thirty-three&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifty-one&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and sixty-nine&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and eighty-seven&lt;/TD&gt;
&lt;TD align=center&gt;two hundred and five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=center&gt;L2(mm)&lt;/TD&gt;
&lt;TD align=center&gt;fifty&lt;/TD&gt;
&lt;TD align=center&gt;sixty-eight&lt;/TD&gt;
&lt;TD align=center&gt;eighty-six&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and four&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and twenty-two&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and forty&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and fifty-eight&lt;/TD&gt;
&lt;TD align=center&gt;one hundred and seventy-six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 241px; WIDTH: 526px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F4-8III/W series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/2006-05/20060527_112748.jpg&quot; width=526 height=241&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-4I/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/26.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:36</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;&lt;BR&gt;Suitable for various isolation switches Complete cabinet, high-voltage operating mechanism, vacuum circuit breaker&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1 heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and sixteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;TABLE&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Appearance and installation dimensions:&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 256px; WIDTH: 530px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimension diagram of F4-4I/W series auxiliary switch&quot; src=&quot;/uploadfiles/2006-05/20060526_200451.jpg&quot; width=530 height=256&gt;&lt;BR&gt;F4-4I/W series auxiliary switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-4II/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/25.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:28</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;F4-4II/W series auxiliary switches are suitable for various isolation switches Complete cabinet, high-voltage operating mechanism, vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=680 align=center border=1 heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ninety-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and eighty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;sixty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 226px; WIDTH: 521px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F4-4II/W series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/2006-05/20060526_195842.jpg&quot; width=521 height=226&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F4-8II/W series auxiliary switch </title>
           <link>http://www.91way.com/info_en/24.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:19</pubDate>
           <comments></comments>
           <description>1﹜ Purpose:&lt;BR&gt;The F4-8II/W series auxiliary switch is mainly used for the control of closing, opening, interlocking, and signal control in the operating mechanism of various high-voltage circuit breakers and high-voltage isolating switches. It can also be used as a conversion switch or combination switch.&lt;BR&gt;&lt;BR&gt;2﹜ Usage conditions&lt;BR&gt;1. Altitude not exceeding 3000 meters;&lt;BR&gt;2. The ambient temperature ranges from -40 ⊥ to+40 ⊥;&lt;BR&gt;3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%;&lt;BR&gt;4. The vibration acceleration shall not exceed 15 meters per second;&lt;BR&gt;5. There is no explosion hazard, fire, dust, insulation damage, or corrosive metal gas in the surrounding medium.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F2 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/23.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:10</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;&lt;BR&gt;The F2 series auxiliary switch is suitable for various isolation switches Complete cabinet set&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1 heihgt=&quot;&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-2&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-6&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-8&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-10&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F2-12&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;70&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;130&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;160&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;190&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;220&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;F2 series auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 232px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of F2 series auxiliary switch&quot; src=&quot;/uploadfiles/2006-05/20060526_194709.jpg&quot; width=550 height=232&gt;&lt;BR&gt;&lt;BR&gt;F2 series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F1 series auxiliary switch </title>
           <link>http://www.91way.com/info_en/22.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:35:02</pubDate>
           <comments></comments>
           <description>The F1 series auxiliary switch is suitable for various isolation switches Complete cabinet set&lt;BR&gt;Technical Specifications:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-6&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-8&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-10&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;F1-12&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;sixty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;143&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;203&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and thirty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;54&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;114&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;Appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 250px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F1 series auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/2006-05/20060526_194414.jpg&quot; width=550 height=250&gt;&lt;BR&gt;&lt;BR&gt;F1 series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]F6-12I/L type auxiliary switch </title>
           <link>http://www.91way.com/info_en/21.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:34:53</pubDate>
           <comments></comments>
           <description>F6-12I/L-type auxiliary switch is suitable for various high-voltage operating mechanisms and vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;F6-12I/L-type auxiliary switch technical parameters:&lt;BR&gt;Rated voltage: AC380V-220V&lt;BR&gt;Rated current: 10A&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;P align=center&gt;Normally open and normally closed logarithm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;Number of partition sections&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L1(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and ninety-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;two hundred and twenty-one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;L2(mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty-nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and thirty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and fifty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and sixty-seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;F6-12I/L-type auxiliary switch appearance and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 243px; WIDTH: 505px; FILTER: none&quot; border=0 hspace=0 alt=&quot;F6-12I/L-type auxiliary switch external dimensions&quot; src=&quot;/uploadfiles/2006-05/20060531_091942.jpg&quot; width=505 height=243&gt;&lt;BR&gt;&lt;BR&gt;F6- ↓ I/L series auxiliary switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[auxiliary switch]ZKF9 series vacuum assisted switch </title>
           <link>http://www.91way.com/info_en/20.html</link>
           <author></author>
           <guid></guid>
           <category>auxiliary switch</category>
           <pubDate>2026-6-16 20:34:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201111/20111101173125870.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 3554px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZKF9 series vacuum assisted switch technical parameters and installation dimensions&quot; src=&quot;/upload2011/201111/20111101173125870.jpg&quot; width=680 height=3554&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKF9 series vacuum assisted switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]STG Integrated three-way sleeve </title>
           <link>http://www.91way.com/info_en/25744.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:26:22</pubDate>
           <comments></comments>
           <description>The STG integrated three-way sleeve 630A integrated sleeve seat is designed with insulation, shielding, and waterproofing, in compliance with DIN47636-7-1990 standard. It is suitable for the installation of European box transformers, ring main units, or other equipment, and provides a 630A standard sleeve interface. It is usually connected to European touchable front and rear connectors. The sensing point on the sleeve can be directly grounded or connected to a live display to indicate that the sleeve is live, suitable for air insulated or SF6 insulated media.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]JYM-624 Insulation protection cap </title>
           <link>http://www.91way.com/info_en/25742.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:26:14</pubDate>
           <comments></comments>
           <description>JYM-624 insulation protection cap is only used for insulation protection (permanent or temporary) of live equipment sleeves, busbars, and other equipment, and provides dust and moisture prevention for non live sleeves.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]GIS test casing for GIS} </title>
           <link>http://www.91way.com/info_en/24756.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:26:05</pubDate>
           <comments></comments>
           <description>DC510kV GIS test bushing&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]DC210kV GIS transformer bushing </title>
           <link>http://www.91way.com/info_en/24755.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:57</pubDate>
           <comments></comments>
           <description>DC210kV GIS transformer bushing&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]252kV Fiberglass dry-type transformer bushing (cable through type) </title>
           <link>http://www.91way.com/info_en/24751.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:48</pubDate>
           <comments></comments>
           <description>The 252kV fiberglass dry-type transformer bushing (cable type) adopts fiberglass composite material for internal insulation and silicone rubber composite material for external insulation, which has many advantages such as oil-free, gas free, porcelain free, explosion-proof, environmentally friendly, maintenance free, and strong pollution flashover resistance. The capacitor core of this product adopts patented technology of stress splitting buffer lining, which greatly reduces internal stress, stabilizes product quality, and improves the product's ability to withstand cold and hot shocks and safe operation level.&lt;BR&gt;&lt;BR&gt;Main performance of 252kV fiberglass dry-type transformer bushing (cable through type)&lt;BR&gt;&lt;BR&gt;Execute standard GB/T 4109-2008 IEC 60137 Ed.6.0&lt;BR&gt;Rated voltage 252kV&lt;BR&gt;Rated current 630A~1250A&lt;BR&gt;1-minute power frequency dry (wet) withstand voltage 505kV&lt;BR&gt;Lightning full wave impulse withstand voltage 1050kV&lt;BR&gt;Tan 汛 ≒ 0.004 at 1.05 times the highest phase voltage&lt;BR&gt;Partial discharge under rated voltage ≒ 10pc&lt;BR&gt;Bending test load 4000N-5000N&lt;BR&gt;Minimum nominal creepage distance 31mm/kV&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]CHN3-24KV(225KYN28) Contact box </title>
           <link>http://www.91way.com/info_en/19007.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201205/20120509194951758.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 279px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Appearance and installation dimensions of CHN3-24KV (225KYN28) contact box&quot; src=&quot;/upload2012/201205/20120509194951758.jpg&quot; width=500 height=279&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CHN3-24KV (225KYN28) Contact Box&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]10KV Insulation components </title>
           <link>http://www.91way.com/info_en/17932.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120206094609939.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 704px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of 10KV insulation components&quot; src=&quot;/upload2012/201202/20120206094609939.jpg&quot; width=680 height=704&gt;&lt;/A&gt;&lt;BR&gt;10KV insulation components&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]220KV Lightning arrester shielding cover </title>
           <link>http://www.91way.com/info_en/6214.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:22</pubDate>
           <comments></comments>
           <description>220KV lightning arrester shielding cover&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]6-3.5KV Pressing insulation components </title>
           <link>http://www.91way.com/info_en/4815.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:13</pubDate>
           <comments></comments>
           <description>6-3.5KV pressed insulation components&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]10KV Outdoor (SF6) insulation sleeve </title>
           <link>http://www.91way.com/info_en/3848.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:25:05</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The 10KV outdoor (SF6) insulation sleeve is made of imported epoxy resin injection molded composite core rod, which has the advantages of high density, no bubbles, high mechanical strength, and good voltage resistance.&lt;BR&gt;&lt;BR&gt;The outer layer is made of high-quality high-temperature vulcanized silicone rubber mold compression molding, which has good resistance to outdoor creep.&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]35KV High voltage metering box hollow core insulation sleeve </title>
           <link>http://www.91way.com/info_en/3847.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:56</pubDate>
           <comments></comments>
           <description>The 35KV high-voltage metering box hollow insulation sleeve is made of imported epoxy resin injection molded composite core rod, which has the advantages of high density, no bubbles, high mechanical strength, and good voltage resistance.&lt;BR&gt;&lt;BR&gt;The outer layer is made of high-quality high-temperature vulcanized silicone rubber mold compression molding, which has good resistance to outdoor creep.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG↓1-10Q/180 ℅ 220} Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3018.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:48</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212104731624.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 214px; WIDTH: 458px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TG ↓ 1-10Q/180 &#215; 220 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/2008212104731624.jpg&quot; width=458 height=214&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TG ↓ 1-10Q/180 &#215; 220 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TGN↓3-10Q/140 ℅ 175 ℅ 260 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3017.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212104647444.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 244px; WIDTH: 440px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TGN ↓ 3-10Q/140 &#215; 175 &#215; 260 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/2008212104647444.jpg&quot; width=440 height=244&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGN ↓ 3-10Q/140 &#215; 175 &#215; 260 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG↓1-10Q/170 ℅ 170} Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3016.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:31</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200802/200821210464275.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 224px; WIDTH: 462px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TG ↓ 1-10Q/170 &#215; 170 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/200821210464275.jpg&quot; width=462 height=224&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TG ↓ 1-10Q/170 &#215; 170 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TGY↓3-10Q/110 ℅ 180} Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3015.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:22</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212104447193.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 224px; WIDTH: 450px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TGY ↓ 3-10Q/110 &#215; 180 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/2008212104447193.jpg&quot; width=450 height=224&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGY ↓ 3-10Q/110 &#215; 180 insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TGY↓3-10Q/140 ℅ 200 ℅ 270 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3014.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:14</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/200821210429679.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 224px; WIDTH: 477px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TGY ↓ 3-10Q/140 &#215; 200 &#215; 270 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/200821210429679.jpg&quot; width=477 height=224&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGY ↓ 3-10Q/140 &#215; 200 &#215; 270 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TGY↓3-10Q/140 ℅ 200} Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3013.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:24:05</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212104119654.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 224px; WIDTH: 461px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TGY ↓ 3-10Q/140 &#215; 200 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/2008212104119654.jpg&quot; width=461 height=224&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TGY ↓ 3-10Q/140 &#215; 200 insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]ZN↓3-10Q/ 耳 75 ℅ 140 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3012.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:56</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103913687.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 221px; WIDTH: 168px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZN ↓ 3-10Q/耳 75 &#215; 140 Installation dimensions for insulation parts and sleeves&quot; src=&quot;/uploadfiles/200802/2008212103913687.jpg&quot; width=168 height=221&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZN ↓ 3-10Q/耳 75 &#215; 140 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]ZN↓3-10Q/ 耳 77 ℅ 130 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3010.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:47</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103650922.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 224px; WIDTH: 166px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of insulation parts and sleeves for ZN ↓ 3-10Q/耳 77 &#215; 130&quot; src=&quot;/uploadfiles/200802/2008212103650922.jpg&quot; width=166 height=224&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;ZN ↓ 3-10Q/耳 77 &#215; 130 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG↓1-10Q/ 耳 150 ℅ 235 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3009.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103550804.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 183px; WIDTH: 381px; FILTER: none&quot; border=0 hspace=0 alt=&quot;TG ↓ 1-10Q/耳 150 &#215; 235 Insulation parts and sleeve installation dimensions&quot; src=&quot;/uploadfiles/200802/2008212103550804.jpg&quot; width=381 height=183&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;TG ↓ 1-10Q/耳 150 &#215; 235 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]CHY2-10Q/210 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3008.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:30</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103432949.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 174px; WIDTH: 483px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CHY2-10Q/210 insulation parts and sleeves&quot; src=&quot;/uploadfiles/200802/2008212103432949.jpg&quot; width=483 height=174&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CHY2-10Q/210 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]ZNY1-10Q/ 耳 110 ℅ 130 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3007.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:22</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103255374.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 218px; WIDTH: 444px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of insulation parts and sleeves for ZNY1-10Q/耳 110 &#215; 130&quot; src=&quot;/uploadfiles/200802/2008212103255374.jpg&quot; width=444 height=218&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZNY1-10Q/耳 110 &#215; 130 insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]ZW12-10Q/ 耳 60 ℅ 250 Outdoor insulation pull rod </title>
           <link>http://www.91way.com/info_en/3006.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212103055418.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 110px; WIDTH: 456px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZW12-10Q/耳 60 &#215; 250 Outdoor Insulation Pull Rod Outline Dimensional Drawing&quot; src=&quot;/uploadfiles/200802/2008212103055418.jpg&quot; width=456 height=110&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;ZW12-10Q/耳 60 &#215; 250 outdoor insulation pull rod&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]CHY2-10Q/230 Insulation parts and sleeves </title>
           <link>http://www.91way.com/info_en/3005.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:23:05</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200802/2008212102946809.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 198px; WIDTH: 497px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CHY2-10Q/230 insulation parts and sleeves&quot; src=&quot;/uploadfiles/200802/2008212102946809.jpg&quot; width=497 height=198&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;CHY2-10Q/230 Insulation parts and sleeves&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]CH-12 type contact box </title>
           <link>http://www.91way.com/info_en/2901.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:22:56</pubDate>
           <comments></comments>
           <description>CH-12 type contact box&lt;BR&gt;&lt;BR&gt;Product description: This product is molded by epoxy resin automatic pressure gel process, and is used for insulation isolation and connection transition in high-voltage switchgear with rated voltage of 10KV and below.&lt;BR&gt;&lt;BR&gt;Contact box model&lt;BR&gt;CH1-12/150 rated current (630A)&lt;BR&gt;CH2-12/180 rated current (1250A)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG2-12 type casing </title>
           <link>http://www.91way.com/info_en/2900.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:22:48</pubDate>
           <comments></comments>
           <description>Product name: bushing Product description: TG2-12 bushing is formed by epoxy resin automatic pressure gel process and used for insulation isolation and connection transition in high-voltage switchgear with rated voltage of 10KV and below.&lt;BR&gt;Sleeve model:&lt;BR&gt;&lt;BR&gt;TG2〞12/100&#215;100&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG1-12 type casing </title>
           <link>http://www.91way.com/info_en/2899.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:22:39</pubDate>
           <comments></comments>
           <description>Product Name: Sleeve&lt;BR&gt;Product description: TG1-12 bushing is formed by epoxy resin automatic pressure gel process and used for insulation isolation and connection transition in high-voltage switchgear with rated voltage of 10KV and below.&lt;BR&gt;Sleeve model: TG1-12/110 &#215; 180&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]CH↓-12~40.5 series contact box </title>
           <link>http://www.91way.com/info_en/2314.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:22:30</pubDate>
           <comments></comments>
           <description>CH ↓ -12~40.5 series contact boxes are of epoxy resin APG process pressure gel forming structure, and the product performance meets the GB311.1-1997 standard and IEC273 standard. Suitable for use in handcart type switchgear or other switchgear with rated voltages of 12kV, 40.5kV and below, serving as insulation isolation and connection transition.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Insulated pipe fittings]TG↓-12~40.5 series insulation sleeves </title>
           <link>http://www.91way.com/info_en/2313.html</link>
           <author></author>
           <guid></guid>
           <category>Insulated pipe fittings</category>
           <pubDate>2026-6-16 20:22:21</pubDate>
           <comments></comments>
           <description>TG ↓ -12~40.5 series casing is of epoxy resin APG process pressure gel forming structure, and the product performance meets the GB311.1-1997 standard and IEC273 standard. Suitable for insulation isolation and connection transition in complete sets of equipment with rated voltage of 12kV, 40.5kV and below.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD1-126/2000-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24900.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:46</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for BD port 1-126/2000-40 vacuum circuit breaker is used for ZW-126.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD1-72.5/2000-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24899.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:38</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for BD port 1-72.5/2000-31.5 vacuum circuit breakers is a glass insulated enclosure used for vacuum circuit breakers.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD700Z Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24898.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:30</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD700Z vacuum circuit breaker (BD700 (24kV/1250A-16k) used for ZN-24, etc&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD1-126/2500-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24897.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:21</pubDate>
           <comments></comments>
           <description>The main supporting machine models and usage locations of vacuum arc extinguishing chambers for BD1-126/2500-40 vacuum circuit breakers (reference):&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1000-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19997.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:13</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/1000-25A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/3150-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19996.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:40:04</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/3150-40 vacuum circuit breaker&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/2500-40A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19995.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:56</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/2500-40A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/2000-31.5A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19994.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:47</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/2000-31.5A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/2000-40A  Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19993.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:38</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/2000-40A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1600-40A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19992.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:30</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/1600-40A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/2500-31.5A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19991.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:21</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/2500-31.5A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/800-16D Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19990.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:13</pubDate>
           <comments></comments>
           <description>BD11-12/800-16D vacuum circuit breaker with vacuum arc extinguishing chamber for vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/630-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19989.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:39:05</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/630-25A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1600-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19988.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:56</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/1600-25A vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/630-16A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19987.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:48</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/630-16A vacuum circuit breaker with ZN28, 33, 63, 68 series vacuum circuit breakers&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1000-20A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19986.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:39</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for BD11-12/1000-20A vacuum circuit breaker&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1250-20A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19985.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:31</pubDate>
           <comments></comments>
           <description>BD11-12/1250-20A vacuum arc extinguishing chamber for ZN28, ZN33, ZN63, ZN68 vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/1250-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19984.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:22</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;BD11-12/1250-25A vacuum circuit breaker with vacuum arc extinguishing chamber equipped with ZN28, ZN33, ZN63, ZN68 circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BF-40.5/630-20 (3010) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14214.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:14</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for BF-40.5/630-20 (3010) load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated closed-loop breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated short-circuit withstand current (4S)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated active load breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Rated cable charging breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;≒40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;P align=center&gt;150&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;16&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;850&#177;100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100617213430384.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 371px&quot; border=0 hspace=0 alt=&quot;BF-40.5/630-20 (3010) Vacuum arc extinguishing chamber for load switch external dimensions&quot; src=&quot;/upload2010/201006/20100617213430384.jpg&quot; width=550 height=371&gt;&lt;/A&gt;&lt;BR&gt;BF-40.5/630-20 (3010) Vacuum arc extinguishing chamber for load switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/630-12.5 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14041.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:38:05</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for BD-12/630-12.5 circuit breakers adopts a medium sealed structure, a glass shell, contacts made of CuCr50 alloy material, a cup-shaped longitudinal magnetic structure, and has the characteristics of high current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;180&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of glass vacuum arc extinguishing chamber for BD-12/630-12.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;1600&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614233718838.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 469px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Dimensions of glass vacuum arc extinguishing chamber for circuit breaker BD-12/630-12.5&quot; src=&quot;/upload2010/201006/20100614233718838.jpg&quot; width=469 height=500&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/630-12.5&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/1250-20 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14040.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:57</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for BD-12/1250-20 circuit breaker adopts a medium sealed structure, glass shell, CuCr50 alloy contacts, cup-shaped longitudinal magnetic structure, with the characteristics of large current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, low noise, etc. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations.&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P align=center&gt;Parameter Name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=373&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;Year year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-20&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;2000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=92&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614233412770.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 547px; HEIGHT: 605px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-20&quot; src=&quot;/upload2010/201006/20100614233412770.jpg&quot; width=547 height=605&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-20&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/1250-25 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14039.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:48</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for BD-12/1250-25 circuit breaker adopts a medium sealed structure, glass shell, CuCr50 alloy contacts, cup-shaped longitudinal magnetic structure, with the characteristics of large current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, low noise, etc. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-25&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P align=center&gt;Parameter Name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;rated voltage&lt;/P&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;rated current&lt;/P&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;mechanical life&lt;/P&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;
&lt;P&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343&gt;
&lt;P&gt;Allowable storage period&lt;/P&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;contact gap&lt;/P&gt;
&lt;P&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;2500&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=295&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614232246258.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 366px; HEIGHT: 498px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-25&quot; src=&quot;/upload2010/201006/20100614232246258.jpg&quot; width=366 height=498&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-25&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/1250-31.5 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14027.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:40</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-31.5 adopts a medium sealed structure, glass shell, CuCr50 alloy contacts, cup-shaped longitudinal magnetic structure, with the characteristics of large current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-31.5&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=367&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=283&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614212406373.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 420px; HEIGHT: 509px&quot; border=0 hspace=0 alt=&quot;Outline dimensions of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-31.5&quot; src=&quot;/upload2010/201006/20100614212406373.jpg&quot; width=420 height=509&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/1250-31.5&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/1600-31.5 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14026.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:31</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for circuit breaker BD-12/1600-31.5 adopts a medium sealed structure, a glass shell, contacts made of CuCr50 alloy material, a cup-shaped longitudinal magnetic structure, and has the characteristics of large current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1600-31.5&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Parameter Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Contact wear allowance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P align=center&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=281&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614211845578.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 420px; HEIGHT: 509px&quot; border=0 hspace=0 alt=&quot;Dimensions of glass vacuum arc extinguishing chamber for circuit breaker BD-12/1600-31.5&quot; src=&quot;/upload2010/201006/20100614211845578.jpg&quot; width=420 height=509&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/1600-31.5&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/2000-40 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14025.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:23</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber used in the BD-12/2000-40 circuit breaker adopts a medium sealed structure, a glass shell, contacts made of CuCr50 alloy material, a cup-shaped longitudinal magnetic structure, and has the characteristics of high current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-12/2000-40&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;rated voltage&lt;/P&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;rated current&lt;/P&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;mechanical life&lt;/P&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;
&lt;P&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Internal gas pressure&lt;BR&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P&gt;Allowable storage period&lt;BR&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;contact gap&lt;/P&gt;
&lt;P&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;3&#177;&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;4500&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=99&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/upload2010/201006/20100614211446385.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 391px; HEIGHT: 492px&quot; border=0 hspace=0 alt=&quot;Dimensions of glass vacuum arc extinguishing chamber for circuit breaker BD-12/2000-40&quot; src=&quot;/upload2010/201006/20100614211446385.jpg&quot; width=391 height=492&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-12/2000-40&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-40.5/1250-25 Glass vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14024.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:14</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The glass vacuum arc extinguishing chamber for circuit breaker BD-40.5/1250-25 adopts a medium sealed structure, glass shell, CuCr50 alloy contacts, cup-shaped longitudinal magnetic structure, with the characteristics of large current breaking capacity, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, low noise, etc. The outdoor vacuum circuit breaker assembled with it is used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of glass vacuum arc extinguishing chamber for circuit breaker BD-40.5/1250-25&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Next Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;250&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;330&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=307&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;22&#177;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;8&#177;2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;2900&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=271&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614211052938.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 395px; HEIGHT: 498px&quot; border=0 hspace=0 alt=&quot;Outline dimensions of glass vacuum arc extinguishing chamber for circuit breaker BD-40.5/1250-25&quot; src=&quot;/upload2010/201006/20100614211052938.jpg&quot; width=395 height=498&gt;&lt;/A&gt;&lt;BR&gt;Glass vacuum arc extinguishing chamber for circuit breaker BD-40.5/1250-25&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/2000-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9222.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:37:06</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;&lt;BR&gt;The BD-12/2000-31.5 vacuum arc extinguishing chamber is a miniaturized product that uses copper chromium contact material, cup-shaped longitudinal magnetic field structure, glass insulation surgery, and a middle sealed fixed shielding cylinder. The product has the characteristics of small size, large breaking capacity, and high pressure resistance. Paired with corresponding indoor and outdoor vacuum circuit breakers, it can be widely used in places where circuits are frequently operated in industrial sectors such as power, machinery, chemical, metallurgical, and mining.&lt;BR&gt;&lt;BR&gt;Main technical parameters of BD-12/2000-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=32 width=236 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD height=32 width=63 align=middle&gt;unit&lt;/TD&gt;
&lt;TD height=32 width=197 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3 (0.5) S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;200&#177;60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;300&#177;60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;two point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;five point three&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091112232530476.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 410px&quot; border=0 hspace=0 alt=&quot;Outline dimensions of vacuum arc extinguishing chamber BD-12/2000-31.5&quot; src=&quot;/upload2009/200911/20091112232530476.jpg&quot; width=680 height=410&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD11-12/630-20A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/6819.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:57</pubDate>
           <comments></comments>
           <description>&lt;P&gt;BD11-12/630-20A vacuum arc extinguishing chamber:&lt;BR&gt;Outline dimension diagram&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200910/2009101885630319.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 342px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;BD11-12/630-20A vacuum arc extinguishing chamber external dimensions&quot; src=&quot;/uploadfiles/200910/2009101885630319.jpg&quot; width=342 height=580&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TH scope=col&gt;parameter name&lt;/TH&gt;
&lt;TH scope=col&gt;parameter value&lt;/TH&gt;
&lt;TH scope=col&gt;unit&lt;/TH&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD&gt;forty-two&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;O-0.3(0.5)s-CO-180s-CO&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current times&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;ten thousand&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact self closing force&lt;/TD&gt;
&lt;TD&gt;100&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force at rated opening distance&lt;/TD&gt;
&lt;TD&gt;200&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;
&lt;TD&gt;米次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Allowable wear thickness of contacts&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;zero point zero zero one&lt;/TD&gt;
&lt;TD&gt;Pa&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD&gt;one point one&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;three point five&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;contact gap&lt;/TD&gt;
&lt;TD&gt;11&#177;1&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average opening speed&lt;/TD&gt;
&lt;TD&gt;1.1&#177;0.3&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average closing speed&lt;/TD&gt;
&lt;TD&gt;0.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD&gt;2000&#177;200&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;outer diameter&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;installation height&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;appearance&lt;/TD&gt;
&lt;TD&gt;Mid sealed style&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]ZKBD-1250/12-31.5 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2247.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:47</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKBD vacuum switch tube uses oxidized glass as the insulating shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgical, textile, and high-rise buildings.&lt;BR&gt;&lt;BR&gt;This product, equipped with a suitable operating mechanism, can be assembled into an AC high-voltage circuit breaker, used as a distribution device in three-phase AC power generation and supply systems, and as a centralized control device for electric motors.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKBD-1250/12-31.5 vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated voltage 12KV&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated peak withstand current 80KA&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 1250, 1600A&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit breaking current 25, 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand current 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking times 30 times&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with circuit breaker ZN28-12 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated impulse withstand voltage 75KV&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact self closing force 190 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit closing current 80KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742119586949.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 630px; HEIGHT: 382px&quot; border=0 hspace=0 alt=&quot;ZKBD-1250/12-31.5 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742119586949.jpg&quot; width=630 height=382&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]ZKBD-1250/12-25 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2246.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:39</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;The ZKBD vacuum switch tube uses oxidized glass as the insulating shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgical, textile, and high-rise buildings.&lt;BR&gt;&lt;BR&gt;The ZKBD-1250/12-25 vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into an AC high-voltage circuit breaker and used as a distribution device in three-phase AC power generation and supply systems, as well as a centralized control device for electric motors.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKBD-1250/12-25 vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=2 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated voltage 12KV&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated peak withstand current 80KA&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 1250, 1600A&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit breaking current 25, 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand current 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking times 30 times&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with circuit breaker ZN28-12 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated impulse withstand voltage 75KV&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact self closing force 190 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit closing current 80KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421165113675.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 630px; HEIGHT: 382px&quot; border=0 hspace=0 alt=&quot;ZKBD-1250/12-25 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421165113675.jpg&quot; width=630 height=382&gt;&lt;/A&gt;&lt;BR&gt;ZKBD-1250/12-25 vacuum switch tube&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]ZKBD-630/12-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2245.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKBD vacuum switch tube uses oxidized glass as the insulating shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgical, textile, and high-rise buildings.&lt;BR&gt;This product, equipped with a suitable operating mechanism, can be assembled into an AC high-voltage circuit breaker, used as a distribution device in three-phase AC power generation and supply systems, and as a centralized control device for electric motors.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated voltage 12KV&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated peak withstand current 80KA&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 1250, 1600A&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit breaking current 25, 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand current 31.5KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking times 30 times&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with circuit breaker ZN28-12 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated impulse withstand voltage 75KV&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact self closing force 190 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-circuit closing current 80KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 40N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421164730900.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 630px; HEIGHT: 382px&quot; border=0 hspace=0 alt=&quot;ZKBD-630/12-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164730900.jpg&quot; width=630 height=382&gt;&lt;/A&gt;&lt;/P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=5 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;ZKBD-630/12-20 vacuum switch tube&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]ZKBDW-630/12-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2244.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:22</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKTD vacuum switch tube adopts high alumina glass as the insulation shell, and is covered with high-strength corrugated insulation material on the outside. The tube uses high vacuum as the medium, so it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, textile, and high-rise buildings.&lt;BR&gt;&lt;BR&gt;The ZKBDW-630/12-20 vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into an AC high-voltage circuit breaker and used as a distribution and motor centralized control device in three-phase AC power generation and supply systems.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKBDW-630/12-20 vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=2 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated voltage 10KV&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Rated short-time withstand current 20KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated working current 630A&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated short-circuit breaking current 20KA&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Contact self closing force 190 &#177; 40N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated current breaking times 30 times&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 40N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated impulse withstand voltage 75KV&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated short-circuit closing current 50KA (peak)&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated peak withstand current 50KA&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;47%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;53%&quot;&gt;Equipped with circuit breaker ZW8-12 type&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZKBDW-630/12-20 vacuum switch tube external dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/2007421164542592.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 182px; HEIGHT: 285px&quot; border=0 hspace=0 alt=&quot;ZKBDW-630/12-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164542592.jpg&quot; width=182 height=285&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Glass arc extinguishing chamber]BD-12/3150-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/74.html</link>
           <author></author>
           <guid></guid>
           <category>Glass arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:36:13</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201005/20100518203540373.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 720px&quot; border=0 hspace=0 alt=&quot;Main parameters of vacuum arc extinguishing chamber for BD-12/3150-40 circuit breaker&quot; src=&quot;/upload2010/201005/20100518203540373.jpg&quot; width=680 height=720&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for BD-12/3150-40 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/630-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26465.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:23</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/630-20 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;ZMF-12/630-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated peak closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;≒35米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;150&#177;30N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202601413.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/630-20 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202601413.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26464.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:15</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/630-12.5 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;ZMF-12/630-12.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated peak closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;100&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;160&#177;30N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202334329.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/630-12.5 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202334329.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/400-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26463.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:34:07</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/400-20 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;ZMF-12/400-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;2KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;50HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Vacuum self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Maximum opening distance of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;4mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Tensile force at a contact opening distance of 4mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;120&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Contact resistance when the contact naturally closes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;≒200米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Power frequency withstand voltage at a contact distance of 4mm (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;43%&quot;&gt;
&lt;P align=center&gt;20KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;56%&quot;&gt;
&lt;P&gt;Maximum closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112202011723.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/400-20 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112202011723.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMF-12/400-16 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/26462.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:58</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for ZMF-12/400-16 vacuum load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 80%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;80%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;ZMF-12/400-16&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Rated operating frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;50HZ&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Vacuum self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;90&#177;20N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Maximum opening distance of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;6mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Tensile force at a contact opening distance of 4mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;10&#177;15N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Contact resistance when the contact naturally closes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;≒70米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Power frequency withstand voltage at a contact distance of 4mm (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;38-42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;55%&quot;&gt;
&lt;P&gt;Maximum closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;44%&quot;&gt;
&lt;P align=center&gt;16KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112201550259.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 400px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for ZMF-12/400-16 vacuum load switch&quot; src=&quot;/upload2015/201501/20150112201550259.jpg&quot; width=400 height=400&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-12/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24922.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:49</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD32-12/630-12.5 vacuum circuit breaker is made of ceramic shell and is used for mining switches.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-7.2/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24921.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:38</pubDate>
           <comments></comments>
           <description>TD32-7.2/630-12.5 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD25-12/1250-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24920.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:28</pubDate>
           <comments></comments>
           <description>Vacuum arc extinguishing chamber for TD25-12/1250-20 vacuum circuit breaker&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD25-12/630 series Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24919.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:20</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD25-12/630 series vacuum circuit breakers is made of ceramic shell and is used for ZW33-12/D630-20 (recloser) and other applications.&lt;BR&gt;&lt;BR&gt;TD25-12/630-20&lt;BR&gt;TD25-12/630-20C&lt;BR&gt;TD25-12/630-20A&lt;BR&gt;TD25-12/630-16&lt;BR&gt;TD25-12/630-20&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1000-25 (TD4803A) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24918.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:11</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/1000-25 (TD4803A) vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-31.5R (TD34-12/1250-31.5B) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24917.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:33:03</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/1250-31.5R (TD34-12/1250-31.5B) vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 vacuum circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24916.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:55</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/3150-40 vacuum circuit breaker is made of ceramic shell and is used for ZN96-12 with long service life KYN96-12ㄗAMS1ㄘ﹝&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24915.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:46</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD34-12/3150-40A vacuum circuit breaker is a ceramic insulated shell used for ZN63-12 solid sealed vacuum circuit breaker.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/2000-31.5F ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24914.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:38</pubDate>
           <comments></comments>
           <description>TD14A-12/2000-31.5F ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/2500-31.5F Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24913.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:29</pubDate>
           <comments></comments>
           <description>The vacuum interrupter for TD14A-12/2500-31.5F vacuum circuit breaker is a ceramic vacuum interrupter used in vacuum circuit breakers such as ZN63, ZN65, ZN68-12, etc.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/630 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24912.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:21</pubDate>
           <comments></comments>
           <description>The TD14A-12/630 vacuum circuit breaker is equipped with ceramic vacuum arc extinguishing chambers for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, and ZN68 circuit breakers.&lt;BR&gt;&lt;BR&gt;TD14A-12/630-20&lt;BR&gt;TD14A-12/630-25&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1000 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24911.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:12</pubDate>
           <comments></comments>
           <description>The ceramic vacuum arc extinguishing chamber for TD14A-12/1000 vacuum circuit breaker is used for circuit breakers ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, and ZN68.&lt;BR&gt;&lt;BR&gt;TD14A-12/1000-20&lt;BR&gt;TD14A-12/1000-25&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-20 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24910.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:32:04</pubDate>
           <comments></comments>
           <description>TD14A-12/1250-20 ceramic vacuum interrupter is used for high-voltage vacuum circuit breakers such as ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68, etc.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-31.5J Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24909.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:55</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;TD14A-12/1250-31.5J ceramic vacuum arc extinguishing chamber for vacuum circuit breakers, suitable for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68.&lt;BR&gt;&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-31.5L Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24908.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:47</pubDate>
           <comments></comments>
           <description>TD14A-12/1600-31.5L ceramic vacuum arc extinguishing chamber is used for ZN168 (VBG) -12, ZN63, ZN65 and other circuit breakers, with a long life of 100000 cycles.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-25 ceramic insulated shell vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24907.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:38</pubDate>
           <comments></comments>
           <description>TD14A-12/1600-25 ceramic insulated shell vacuum arc extinguishing chamber&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-25 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24906.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:30</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14A-12/1250-25 vacuum circuit breaker is a ceramic insulated shell, used for ZN28, ZN22, ZN33, ZN58, ZN63, ZN65, ZN68 vacuum circuit breakers&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1600-31.5B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24905.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:22</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14A-12/1600-31.5B vacuum circuit breaker is a ceramic insulated shell, used for ZN28﹜ZN22﹜ZN33﹜ZN58﹜ZN63﹜ZN65﹜ZN68﹝&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1250-31.5B/Z Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24904.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:13</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14-12/1250-31.5B/Z vacuum circuit breaker is a ceramic insulated shell arc extinguishing chamber, used for ZN28, ZN22, ZN33, ZN63, ZN68, altitude ≒ 4300m.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1600-31.5B/Z (TD14-12/1600-31.5D)Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24903.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:31:05</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD14-12/1600-31.5B/Z (TD14-12/1600-31.5D) vacuum circuit breaker is a ceramic insulated shell. Used for ZN28, ZN22, ZN33, ZN63, ZN68, altitude ≒ 4300m.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14-12/1250-25A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24902.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:56</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber (TD303A) for TD14-12/1250-25A vacuum circuit breaker is a ceramic insulated housing used for ZN63&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD諳7-12/6300-80A Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24901.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:48</pubDate>
           <comments></comments>
           <description>The vacuum arc extinguishing chamber for TD諳7-12/6300-80A vacuum circuit breaker is a ceramic insulated shell vacuum arc extinguishing chamber used for generator protection of the circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD0132A Low voltage vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/24896.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:39</pubDate>
           <comments></comments>
           <description>TD0132A Low pressure vacuum arc extinguishing chamber&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD12/630-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20718.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:31</pubDate>
           <comments></comments>
           <description>ZMD12/630-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;ZMD12/630-20&lt;BR&gt;ZMD12/630-20(I)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time (lmin) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;150&#177;50N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact reaction force under contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Allowable thickness for electrical wear of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=149&gt;
&lt;P align=center&gt;3.5kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112195552367.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 200px; HEIGHT: 387px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZMD12/630-20 ceramic vacuum arc extinguishing chamber&quot; src=&quot;/upload2015/201501/20150112195552367.jpg&quot; width=200 height=387&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD12/800-25 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20717.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:23</pubDate>
           <comments></comments>
           <description>ZMD12/800-25 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;ZMD12/800-25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;800A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;25KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;63KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;63KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;25KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-time (lmin) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒40米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;150&#177;50N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Contact reaction force under contact opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;Allowable thickness for electrical wear of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=241&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3.3kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150112195746983.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 250px; HEIGHT: 314px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ZMD12/800-25 ceramic vacuum arc extinguishing chamber&quot; src=&quot;/upload2015/201501/20150112195746983.jpg&quot; width=250 height=314&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD14-1250, 1600/10-31.5 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20716.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:14</pubDate>
           <comments></comments>
           <description>ZMD14-1250, 1600/10-31.5 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;ZMD14-1250/10-31.5&lt;BR&gt;ZMD14-1600/10-31.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;50~60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1250﹜1600A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;80KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;80KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;31.5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;30/50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;160&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1.18kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4.1kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Mechanical parameters that the matching vacuum circuit breaker should meet&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;11&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;4&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;1.1&#177;0.2m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;0.6&#177;0.2m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;3350&#177;320N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒2ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=148&gt;
&lt;P align=center&gt;≒1ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZMD14-1250, 1600/10-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20715.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:30:06</pubDate>
           <comments></comments>
           <description>ZMD14-1250, 1600/10-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 450px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=450 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;ZMD14-1250/10-20&lt;BR&gt;ZMD14-1600/10-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;12KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50~60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1250﹜1600A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit closing current (peak)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;50KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4S&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;630A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;400A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-time (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;42KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;75KV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒25米次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;30/50 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;10000 times&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;3mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;160&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;210&#177;60N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1.05kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;quality&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4.kg&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;20a&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Mechanical parameters that the matching vacuum circuit breaker should meet&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;11&#177;1.5/0 mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;4&#177;1mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;1&#177;0.3m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;0.55&#177;0.15m/s&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;2000&#177;200N&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒2ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=243&gt;
&lt;P&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=129&gt;
&lt;P align=center&gt;≒1ms&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160/1.14 ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/20711.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:57</pubDate>
           <comments></comments>
           <description>ZKTJ-160/1.14 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 470px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=470 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;ZKTJ-160/1.14&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;one thousand one hundred and forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;three thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Contact resistance (米 次)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;≒200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Vacuum self closing force (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;17.6&#177;4.9&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;zero point two three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=134&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;98&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131 align=middle&gt;
&lt;P&gt;孜35.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZKTJ-160/1.14 ceramic vacuum switch tube&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-80/0.66 ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/20710.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:49</pubDate>
           <comments></comments>
           <description>ZKTJ-80/0.66 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;Rated voltage 660V, rated current 80A, ultimate breaking capacity 1600A, contact resistance ≒ 300, mass 0.11kg.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 470px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=470 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=left&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;ZKTJ-80/0.66&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;six hundred and sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Rated current (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Ultimate Breaking Capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Electrical lifespan (AC4 times)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;6x104&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Contact resistance (米 次)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;≒300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Vacuum self closing force (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;17&#177;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Mass (Kg)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;zero point one one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=134&gt;
&lt;P&gt;Dimensions (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;68.5&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134 align=middle&gt;
&lt;P&gt;孜30&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;ZKTJ-80/0.66 ceramic vacuum switch tube&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD21-40.5/2000-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20066.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:40</pubDate>
           <comments></comments>
           <description>TD21-40.5/2000-31.5 Ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD12-40.5/2500-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20065.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:32</pubDate>
           <comments></comments>
           <description>TD12-40.5/2500-31.5 Ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-40.5/1600-31.5 Ceramic Vacuum Arc Extinguisher Chamber </title>
           <link>http://www.91way.com/info_en/20064.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:23</pubDate>
           <comments></comments>
           <description>TD27-40.5/1600-31.5 Ceramic Vacuum Arc Extinguisher Chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-40.5/2000-31.5 Ceramic Vacuum Arc Extinguisher Chamber </title>
           <link>http://www.91way.com/info_en/20063.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:15</pubDate>
           <comments></comments>
           <description>TD27-40.5/2000-31.5 Ceramic Vacuum Arc Extinguisher Chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-40.5/1250-16 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20062.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:29:05</pubDate>
           <comments></comments>
           <description>TD24-40.5/1250-16 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-40.5/630-12.5 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20061.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:56</pubDate>
           <comments></comments>
           <description>TD24-40.5/630-12.5 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/3150-31.5C ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20060.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:48</pubDate>
           <comments></comments>
           <description>TD34-24/3150-31.5C ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/1600-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20059.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:40</pubDate>
           <comments></comments>
           <description>TD34-24/1600-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/630-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20058.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:31</pubDate>
           <comments></comments>
           <description>TD34-24/630-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-36/2000-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20057.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:23</pubDate>
           <comments></comments>
           <description>TD27-36/2000-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD17-38/1250-20 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20056.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:13</pubDate>
           <comments></comments>
           <description>TD17-38/1250-20 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD17-38/630-16 ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20055.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:28:05</pubDate>
           <comments></comments>
           <description>TD17-38/630-16 ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD27-36/2000-25A ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20054.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:57</pubDate>
           <comments></comments>
           <description>TD27-36/2000-25A ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-24/1250-20A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20053.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:48</pubDate>
           <comments></comments>
           <description>TD34-24/1250-20A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/6300-80A ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20052.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:40</pubDate>
           <comments></comments>
           <description>TD-12/6300-80A ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD24-12/630-20C ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20051.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:28</pubDate>
           <comments></comments>
           <description>TD24-12/630-20C ceramic vacuum arc extinguishing chamber (TD3738AF1)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20049.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:19</pubDate>
           <comments></comments>
           <description>TD34-12/1250-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1600-31.5A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20048.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:11</pubDate>
           <comments></comments>
           <description>TD34-12/1600-31.5A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/1250-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20047.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:27:03</pubDate>
           <comments></comments>
           <description>TD34-12/1250-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/630-25A/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20046.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:53</pubDate>
           <comments></comments>
           <description>TD34-12/630-25A/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/3150-40C/R ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20045.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:44</pubDate>
           <comments></comments>
           <description>TD34-12/3150-40C/R ceramic vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD34-12/4000-40C/R Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20044.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:36</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD34-12/4000-40C/R vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD31-12/630-20B/R Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/20000.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:28</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD31-12/630-20B/R vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD31-12/630-20B Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19999.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:19</pubDate>
           <comments></comments>
           <description>Ceramic vacuum arc extinguishing chamber for TD31-12/630-20B vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD32-12/800-13.1 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/19998.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:11</pubDate>
           <comments></comments>
           <description>TD32-12/800-13.1 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/5000-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14490.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:26:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623220429395.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 612px; HEIGHT: 336px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/5000-12.5 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623220429395.jpg&quot; width=612 height=336&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-1.14/5000-12.5 Vacuum arc extinguishing chamber for vacuum circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/450-10 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14489.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623220221210.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/450-10 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623220221210.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-1.14/450-10 vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-1.14/400-8 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14488.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623215830515.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 645px; HEIGHT: 345px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-1.14/400-8 vacuum circuit breaker&quot; src=&quot;/upload2010/201006/20100623215830515.jpg&quot; width=645 height=345&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-1.14/400-8 vacuum circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-7.2/400 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14487.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214505767.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 471px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for ZKTJ-7.2/400 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214505767.jpg&quot; width=600 height=471&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for ZKTJ-7.2/400 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-7.2/250 vacuum interrupter for vacuum contactor </title>
           <link>http://www.91way.com/info_en/14486.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:28</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214319632.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for ZKTJ-7.2/250 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214319632.jpg&quot; width=600 height=416&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKTJ-7.2/250 vacuum interrupter for vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-12/160 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14485.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:20</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623214047363.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-12/160 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623214047363.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-12/160 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-7.2/630 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14484.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623213939762.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 681px; HEIGHT: 329px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-7.2/630 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213939762.jpg&quot; width=681 height=329&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-7.2/630 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-7.2/160 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14483.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:25:03</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100623213743801.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-7.2/160 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213743801.jpg&quot; width=680 height=320&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-7.2/160 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/1000 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14482.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213602929.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 616px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/1000 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213602929.jpg&quot; width=616 height=270&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/1000 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/630 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14481.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:46</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213430723.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 618px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/630 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213430723.jpg&quot; width=618 height=291&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/630 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/400 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14480.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:37</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213250281.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 484px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-1.14/400 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213250281.jpg&quot; width=484 height=310&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/400 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/300 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14479.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623213103587.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 589px; HEIGHT: 311px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TJ-1.14/300 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623213103587.jpg&quot; width=589 height=311&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/300 vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14-250 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14478.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623212914995.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 538px; HEIGHT: 314px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14-250 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623212914995.jpg&quot; width=538 height=314&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14-250 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/200 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14476.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:12</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204746377.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 497px; HEIGHT: 326px&quot; border=0 hspace=0 alt=&quot;External dimensions of vacuum arc extinguishing chamber for TJ-1.14/200 vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204746377.jpg&quot; width=497 height=326&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TJ-1.14/200 vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/125(B) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14475.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:24:04</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204543307.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 516px; HEIGHT: 316px&quot; border=0 hspace=0 alt=&quot;TJ-1.14/125 (B) Dimensions of vacuum arc extinguishing chamber for vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204543307.jpg&quot; width=516 height=316&gt;&lt;/A&gt;&lt;BR&gt;TJ-1.14/125 (B) Vacuum arc extinguishing chamber for vacuum contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJ-1.14/125 (A) Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14474.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:55</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100623204329385.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 380px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;TJ-1.14/125 (A) Dimensions of vacuum arc extinguishing chamber for vacuum contactor&quot; src=&quot;/upload2010/201006/20100623204329385.jpg&quot; width=380 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TJ-1.14/125 (A) Vacuum arc extinguishing chamber for vacuum contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/3150-40(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14233.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:47</pubDate>
           <comments></comments>
           <description>&lt;SPAN&gt;TD-12/3150-40 (310mm) Solid Sealing Pole Arc Extinguishing Chamber Solid Sealing Pole 3150-40 Dimensions and Technical Parameters Table&lt;/SPAN&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-180s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;4200&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232727332.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;TD-12/3150-40 (310mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232727332.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/3150-40 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-31.5(275mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14232.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:38</pubDate>
           <comments></comments>
           <description>Technical parameter table for TD-12/2000-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒12&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232508389.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 380px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-31.5 (275mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232508389.jpg&quot; width=680 height=380&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5(275mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14231.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:30</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-12/1250-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;1.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3+10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617232259273.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 250px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 (275mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617232259273.jpg&quot; width=680 height=250&gt;&lt;/A&gt;&lt;BR&gt;TD-12/1250-31.5 (275mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/3150-40 Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14230.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:21</pubDate>
           <comments></comments>
           <description>&lt;SPAN&gt;TD-24/3150-40 Solid Sealed Pole Arc Extinguishing Chamber Dimensions and Technical Parameters Table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three thousand one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-180s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;4200&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/SPAN&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617231654330.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/3150-40 solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617231654330.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/3150-40 solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2500-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14229.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:12</pubDate>
           <comments></comments>
           <description>Table of Dimensions and Technical Parameters for Solid Sealed Pole 24kV/2500-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=4&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/SPAN&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617231437984.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 460px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/2500-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617231437984.jpg&quot; width=680 height=460&gt;&lt;/A&gt;&lt;BR&gt;TD-24/2500-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2000-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14228.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:23:04</pubDate>
           <comments></comments>
           <description>Table of Dimensions and Technical Parameters for Sealed Pole 2000-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒12&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617223902247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 380px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/2000-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617223902247.jpg&quot; width=680 height=380&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/2000-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1600-31.5(310mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14227.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:55</pubDate>
           <comments></comments>
           <description>TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;Table of Dimensions and Technical Parameters for Solid Sealed Pole 24kV/1600-31.5KA&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 99%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;99%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Main technical parameters&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒16&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Allowable storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated operating sequence&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=2&gt;
&lt;P align=center&gt;O-0.3s-CO-180s-CO&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=703 colSpan=5&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot;&gt;Mechanical parameters that the supporting vacuum switch equipment should meet&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617223701704.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617223701704.jpg&quot; width=680 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-24/1600-31.5 (310mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5(205mm) Solid sealed pole arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14226.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:46</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;1.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;&amp;lt;4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100617223246247.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 660px; HEIGHT: 295px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 (205mm) fixed sealed pole arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617223246247.jpg&quot; width=660 height=295&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-12/1250-31.5 (205mm) solid sealed pole arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14225.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:37</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;110&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;190&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;13&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617222548391.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100617222548391.jpg&quot; width=680 height=270&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-24/1250-31.5 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14224.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:29</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;seventy-nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred and forty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;110&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;190&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;13&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617222241248.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100617222241248.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-24/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-24/2000, TD-24/2500-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14223.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:20</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chambers for TD-24/2000, TD-24/2500-31.5 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;2000/2500&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;sixty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nineteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;3+&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2010/201006/20100617221957987.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chambers for circuit breakers TD-24/2000, TD-24/2500-31.5&quot; src=&quot;/upload2010/201006/20100617221957987.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for circuit breakers TD-24/2000, TD-24/2500-31.5&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/2000,TD-40.5/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14222.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:12</pubDate>
           <comments></comments>
           <description>Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1600/2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated Active load breaking current &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;20&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.75&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot; align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617221448550.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 636px; HEIGHT: 277px&quot; border=0 hspace=0 alt=&quot;TD-40.5/2000, TD-40.5/1600-31.5 Vacuum arc extinguishing chamber external dimensions&quot; src=&quot;/upload2010/201006/20100617221448550.jpg&quot; width=636 height=277&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TD-40.5/2000-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-12/630-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14221.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:22:03</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TF-12/630-20 load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated Active load breaking current &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Transfer current (AC current)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three point one five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated closed-loop breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated cable charging breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated no-load transformer breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;80&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;140&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P style=&quot;LINE-HEIGHT: 150%&quot; align=center&gt;twenty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617220255520.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 636px; HEIGHT: 284px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TF-12/630-20 load switch&quot; src=&quot;/upload2010/201006/20100617220255520.jpg&quot; width=636 height=284&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TF-12/630-20 load switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630-6 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14220.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:55</pubDate>
           <comments></comments>
           <description>Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current (maximum/minimum)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;5.0/0.12&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Maximum breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated turn-on current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Withstand overload current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=441&gt;
&lt;P align=center&gt;electrical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;25 (AC-3 category)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1 (AC-4 category)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;85&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;130&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance under self isolation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.45&#177;0.05&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.25&#177;0.05&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Three phase synchronicity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point five&lt;SUP&gt;+0.5&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215909354.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 486px; HEIGHT: 242px&quot; border=0 hspace=0 alt=&quot;TJC-7.2/630-6 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617215909354.jpg&quot; width=486 height=242&gt;&lt;/A&gt;&lt;BR&gt;TJC-7.2/630-6 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-7.2/630-12.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14219.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:46</pubDate>
           <comments></comments>
           <description>Main technical parameters of TD-7.2/630-12.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve point five eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;80&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for TD-7.2/630-12.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;8&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1500&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Contact stroke of contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;2+10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215631304.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 565px; HEIGHT: 317px&quot; border=0 hspace=0 alt=&quot;TD-7.2/630-12.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2010/201006/20100617215631304.jpg&quot; width=565 height=317&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-7.2/400-10 Vacuum arc extinguishing chamber for circuit breakers (mining) </title>
           <link>http://www.91way.com/info_en/14218.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:38</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-7.2-400-10 circuit breaker (mining)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;85&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switch equipment for product matching&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;8&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.0&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;650&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;two&lt;SUP&gt;+0.5&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617215329935.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 305px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-7.2-400-10 circuit breaker (mining)&quot; src=&quot;/upload2010/201006/20100617215329935.jpg&quot; width=600 height=305&gt;&lt;/A&gt;&lt;BR&gt;TD-7.2-400-10 vacuum arc extinguishing chamber for circuit breakers (mining)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/4000-40  Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14217.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:29</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4000&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switchgear equipment for vacuum arc extinguishing chambers (ZN63, ZN28) used in TD-12/4000-40 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;3+1 0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617214908600.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 319px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&quot; src=&quot;/upload2010/201006/20100617214908600.jpg&quot; width=540 height=319&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-12/4000-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZN63,ZN28) Vacuum arc extinguishing chamber for circuit breakers </title>
           <link>http://www.91way.com/info_en/14216.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:21</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;2500/3150&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;KA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;200&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;300&#177;60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;米 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;eighteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;nineteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=441&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;Kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical characteristics and parameters of vacuum switchgear equipment for vacuum arc extinguishing chambers (ZN63, ZN28) used in TD-12/3150-40 circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;10&#177;1.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.7&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;4200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=444&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;three&lt;SUP&gt;+1&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617214602630.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 319px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&quot; src=&quot;/upload2010/201006/20100617214602630.jpg&quot; width=540 height=319&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for TD-12/3150-40 circuit breaker (ZN63, ZN28)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-40, TD-12/1600-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14215.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:12</pubDate>
           <comments></comments>
           <description>Main technical parameters of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Numerical value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1250/1600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;HZ&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Short term (1-minute) power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Lightning impulse withstand voltage (peak value)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-time withstand current (4 seconds)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit duration&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eleven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒15&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;100&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1.33&#215;10&lt;SUP&gt;-3&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Quality of the sports section&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of supporting vacuum switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=4 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;10&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;4300&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Contact closing and opening at different periods&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324&gt;
&lt;P align=center&gt;Contact rebound amplitude&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;≒1.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100617213732180.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 300px&quot; border=0 hspace=0 alt=&quot;Dimensions of vacuum arc extinguishing chambers for circuit breakers TD-12/1250-40 and TD-12/1600-40&quot; src=&quot;/upload2010/201006/20100617213732180.jpg&quot; width=680 height=300&gt;&lt;/A&gt;&lt;BR&gt;Vacuum arc extinguishing chamber for circuit breakers TD-12/1250-40, TD-12/1600-40&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-12/630 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14042.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:21:04</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The arc extinguishing chamber adopts corrugated ceramic as the insulation shell, and the contacts are made of copper tungsten carbide alloy material. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated short-time withstand current voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;BR&gt;Rated lighting impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;70&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;100&#177;40&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=392&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=67&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;BR&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Synchronization of closing&lt;BR&gt;Closing same period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=left&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614234036163.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic vacuum arc extinguishing chamber for TJC-12/630 contactor&quot; src=&quot;/upload2010/201006/20100614234036163.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-12/630 contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-12.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14038.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:55</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, low noise, etc. The outdoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Explanation of Ceramic Vacuum Arc Extinguishing Chamber for TD-12/630-12.5 Circuit Breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;60&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Force required to hold contacts open at full stroke at rated opening distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;160&#177;30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Contact limit abrasion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;zero point three five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;71%&quot;&gt;
&lt;P&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;8&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;1.2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;1200&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Contact bounce duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614232005703.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 418px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100614232005703.jpg&quot; width=418 height=580&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/630-12.5 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1600-25 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14037.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:47</pubDate>
           <comments></comments>
           <description>The ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. Indoor vacuum circuit breakers assembled with it are used for control and protection in power transmission and distribution systems such as industrial and mining, enterprises, and substations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Parameter Name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;rated voltage&lt;/P&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;rated current&lt;/P&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;ninety-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;one hundred and eighty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;mechanical life&lt;/P&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Contact self closing force&lt;/P&gt;
&lt;P&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;300&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P&gt;Allowable storage period&lt;/P&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;
&lt;P align=left&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;contact gap&lt;/P&gt;
&lt;P&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;22&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;8&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;1.4&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;2800&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;
&lt;P&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=348&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;/P&gt;
&lt;P&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614231649277.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 413px; HEIGHT: 515px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1600-25 Ceramic vacuum arc extinguishing chamber for circuit breakers - Dimensions&quot; src=&quot;/upload2010/201006/20100614231649277.jpg&quot; width=413 height=515&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-40.5/1600-25 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-25 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14036.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:38</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The arc extinguishing chamber adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The outdoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current times&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;140&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;230&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact limit erosion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Quality of the sports section&lt;BR&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;one point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;four point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;2000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;63%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614231218983.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 378px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Dimensions of ceramic vacuum arc extinguishing chamber for TD-12/630-25 circuit breaker&quot; src=&quot;/upload2010/201006/20100614231218983.jpg&quot; width=378 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/630-25 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630B Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14035.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:30</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The TJC-7.2/630B contactor uses a ceramic vacuum arc extinguishing chamber with a corrugated ceramic insulation shell and copper tungsten carbide alloy contacts. It adopts advanced one-time sealing technology and has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;BR&gt;Rated lighting impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;70&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact -wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=375&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;BR&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=64&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=left&gt;≒1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614224227482.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&quot; src=&quot;/upload2010/201006/20100614224227482.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-7.2/630B contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-7.2/630A Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14034.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:21</pubDate>
           <comments></comments>
           <description>The TJC-7.2/630A contactor uses a ceramic vacuum arc extinguishing chamber with a corrugated ceramic insulation shell and copper tungsten carbide alloy contacts. It adopts advanced one-time sealing technology and has the advantages of small volume, high insulation level, low current cutoff value, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. The contactor assembled with it can frequently operate various electrical equipment, and when combined with fuses, it can form an F-C cabinet. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;seven point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;five point zero four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;six point three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Rated lightning impulse voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Electricity life&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;70&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Cooperate with the mechanical parameters of the contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;&lt;/P&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=left&gt;unit&lt;/P&gt;
&lt;P align=left&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;numerical value&lt;/P&gt;
&lt;P align=left&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;6&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;2&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Rated contact pressure&lt;BR&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=200&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;BR&gt;Contact closeting bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614223511336.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Outline dimension drawing of ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&quot; src=&quot;/upload2010/201006/20100614223511336.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-7.2/630A contactor&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/600 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14033.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:13</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/600 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-1.14/600 low-voltage contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;four thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;six thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;four thousand and eight hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=96&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;shelf life&lt;BR&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614223109776.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/600 Ceramic Vacuum Arc Extinguisher Chamber Outline Dimensional Drawing for Low Voltage Contactors&quot; src=&quot;/upload2010/201006/20100614223109776.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;TJC-1.14/600 Ceramic Vacuum Arc Extinguishing Chamber for Low Voltage Contactors&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14-400 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14032.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:20:04</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14-400 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;four thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=132&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;90&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;≒100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;TJC-1.14-400 Mechanical parameters of ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;0.3&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=240&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614222658503.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14-400 Ceramic Vacuum Arc Extinguisher for Low Voltage Contactors - Dimensions&quot; src=&quot;/upload2010/201006/20100614222658503.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-1.14-400 low-voltage contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/250A Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14031.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:56</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/250A low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TJC-1.14/250A low-voltage contactor&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Ten thousand times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;50&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;70&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;2&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.6&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;100&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=228&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=120&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614222233345.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/250A Ceramic Vacuum Arc Extinguisher for Low Voltage Contactors - External Dimensions&quot; src=&quot;/upload2010/201006/20100614222233345.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TJC-1.14/250A low-voltage contactor&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TJC-1.14/125 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14030.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:47</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;TJC-1.14/125 low-voltage contactor uses ceramic vacuum arc extinguishing chamber with ceramic insulation shell and WCCu alloy contacts. It adopts advanced one-time sealing and discharging technology, which has the advantages of small volume, strong breaking ability, long service life, simple maintenance, no explosion hazard, no pollution, and low noise. Widely used in coal mines, chemical industry, petroleum metallurgy and other sectors, it is more suitable for use in places with frequent operations and harsh environments. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one point one four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated put through current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Limiting breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=168&gt;
&lt;P&gt;Rated breaking frequency&lt;BR&gt;Rated breaking time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=187&gt;
&lt;P&gt;AC3 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=187&gt;
&lt;P&gt;AC4 category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ten thousand times&lt;BR&gt;Ten thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;zero point six&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;20&#177;10&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;50&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Circuit resistance under contact self closing force&lt;BR&gt;Contact automatic blocking ability loop electrical resistance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;≒120&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;shelf life&lt;BR&gt;Storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355 colSpan=2&gt;
&lt;P&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;TJC-1.14/125 Mechanical parameters of ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;1.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;0.6&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;0.3&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;35&#177;5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=216&gt;
&lt;P&gt;Closing Same Period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=91&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614221941214.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 494px; HEIGHT: 299px&quot; border=0 hspace=0 alt=&quot;TJC-1.14/125 Ceramic vacuum arc extinguishing chamber for low-voltage contactors - Dimensions&quot; src=&quot;/upload2010/201006/20100614221941214.jpg&quot; width=494 height=299&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;TJC-1.14/125 Ceramic vacuum arc extinguishing chamber for low-voltage contactors&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-40.5/1250-20 Ceramic arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14029.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:39</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch adopts a ceramic insulation shell, low current cutoff value, and long-life Wcu contact material, which has the advantages of strong arc extinguishing ability, reliable performance, long life, small size, no explosion hazard, and no environmental pollution The corresponding vacuum automatic switch can be used for control and protection of transmission and distribution systems in power, metallurgy, mining, chemical and other departments, especially suitable for places that require frequent operation. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;Parameter Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;forty point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;50/60&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;BR&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one hundred and seventy&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;BR&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit closing current&lt;BR&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;BR&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Next time&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;60&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;145&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact limit abrasion thickness allowed for contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;zero point four five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one point two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;15&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;1.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.8&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;700&#177;100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;61%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614221509831.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&quot; src=&quot;/upload2010/201006/20100614221509831.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;Ceramic arc extinguishing chamber for TF-40.5/1250-20 load switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TF-12/630-12.5 Ceramic arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14028.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:30</pubDate>
           <comments></comments>
           <description>The ceramic arc extinguishing chamber for TF-12/630-12.5 load switch adopts a ceramic insulation shell, low current cutoff value, long-life Wcu contact material, which has the advantages of strong arc extinguishing ability, reliable performance, long life, small size, no explosion hazard, and no environmental pollution The corresponding vacuum automatic switch can be used for control and protection of transmission and distribution systems in power, metallurgy, mining, chemical and other departments, especially suitable for places that require frequent operation.&lt;BR&gt;&lt;BR&gt;Product Description&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P align=center&gt;parameter name&lt;/P&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated frequency&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Short term (1-minute) power frequency withstand voltage&lt;BR&gt;Short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Lightning impulse withstand voltage&lt;BR&gt;Lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated peak withstand current&lt;BR&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit closing current&lt;BR&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-time withstand current&lt;BR&gt;Rated short time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;twelve point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit duration&lt;BR&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated breaking current of single capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated breaking current of back to back capacitor bank&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Rated short-circuit breaking current times&lt;BR&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;ten&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;time&lt;BR&gt;time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;thirty thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;65&#177;20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;175&#177;35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Circuit resistance at lower limit of rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒35&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact limit erosion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;BR&gt;Gas pressure inside vacuum interrupter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Quality of the sports section&lt;BR&gt;Weight of moving parts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;zero point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;65%&quot;&gt;
&lt;P&gt;Quality of vacuum arc extinguishing chamber&lt;BR&gt;Weight of vacuum interrupte&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;P&gt;kg&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;
&lt;P&gt;one point seven five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters of load switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 500px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=500 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;contact gap&lt;BR&gt;Clearance between open contacts&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;9&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Average opening speed&lt;BR&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.8&#177;0.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Average closing speed&lt;BR&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5&#177;0.1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Rated contact pressure&lt;BR&gt;Rated contact force&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;700&#177;100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Contact closing bounce time&lt;BR&gt;Contact bouncing duration at closing operation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;75%&quot;&gt;
&lt;P&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;P&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;≒&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614213612135.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 498px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;External dimensions of ceramic arc extinguishing chamber for TF-12/630-12.5 load switch&quot; src=&quot;/upload2010/201006/20100614213612135.jpg&quot; width=498 height=500&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Ceramic arc extinguishing chamber for TF-12/630-12.5 load switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-20 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14023.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:22</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small volume, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Parameter Name&lt;BR&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;one thousand two hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;time&lt;/P&gt;
&lt;P align=left&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Next Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Contact self closing force&lt;BR&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Allowable wear thickness of contacts&lt;BR&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=361&gt;
&lt;P align=left&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=left&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;3.5&#177;0.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;2000&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Non synchronous closing and opening of contacts&lt;BR&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=358&gt;
&lt;P align=left&gt;Rebound amplitude of the opening contact&lt;BR&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=left&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=left&gt;≒3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614210557901.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 412px; HEIGHT: 505px&quot; border=0 hspace=0 alt=&quot;Dimensions of ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker&quot; src=&quot;/upload2010/201006/20100614210557901.jpg&quot; width=412 height=505&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/1250-20 circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1600-31.5 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14022.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:13</pubDate>
           <comments></comments>
           <description>Overview&lt;BR&gt;&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;one thousand and six hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;BR&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty-one point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;BR&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;BR&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-time (1min) power frequency withstand voltage&lt;BR&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;BR&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒30&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;BR&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;BR&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;mechanical life&lt;BR&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Next Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Closing force due to bellows and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;BR&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Contact wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=319&gt;
&lt;P align=center&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Year of Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 468px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=468 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;Unit Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;Numerical Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact stroke distance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;3&#177;&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;3100&#177;200&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=312&gt;
&lt;P align=center&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614210052120.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 420px; HEIGHT: 520px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&quot; src=&quot;/upload2010/201006/20100614210052120.jpg&quot; width=420 height=520&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/1600-31.5 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2500-40 Ceramic vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/14021.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:19:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview&lt;BR&gt;The ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker adopts corrugated ceramic as the insulation shell, with CuCr50 alloy contacts and cup-shaped longitudinal magnetic structure. It has the characteristics of large current interruption, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments, and is suitable for places with frequent operations. Product Description&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;Main technique parameter&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Parameter name&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;rated voltage&lt;/P&gt;
&lt;P align=center&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;
&lt;P align=center&gt;Rated normal current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;two thousand and five hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;
&lt;P align=center&gt;Rated short-circuit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit closing current&lt;/P&gt;
&lt;P align=center&gt;Rated short-circuit making current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;
&lt;P align=center&gt;Rated peak withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;
&lt;P align=center&gt;Rated short-time withstand current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit duration&lt;/P&gt;
&lt;P align=center&gt;Rated duration of short circuit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated breaking current of a single capacitor bank&lt;/P&gt;
&lt;P align=center&gt;Rated single capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred and thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated back-to-back capacitor bank breaking current&lt;/P&gt;
&lt;P align=center&gt;Rated back to back capacitor unit breaking current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-time (1min) power frequency withstand voltage&lt;/P&gt;
&lt;P align=center&gt;Rated short time power frequency withstand voltage (1min)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;forty-two&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Circuit resistance under rated contact pressure&lt;/P&gt;
&lt;P align=center&gt;Circuit resistance at lower limit of rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;米次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒25&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated short-circuit breaking current breaking times&lt;/P&gt;
&lt;P align=center&gt;Rated short circuit breaking current breaking times&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;/P&gt;
&lt;P align=center&gt;Rated lightning impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;kV&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seventy-five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;mechanical life&lt;/P&gt;
&lt;P align=center&gt;Mechanical endurance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;time&lt;/P&gt;
&lt;P align=center&gt;Time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;ten thousand&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Contact self closing force&lt;/P&gt;
&lt;P align=center&gt;Closing force due to bellow and atmosphere&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;120&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Contact reaction force at rated opening distance&lt;/P&gt;
&lt;P align=center&gt;Force required to hold contacts open at full stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;200&#177;50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Allowable wear thickness of contacts&lt;/P&gt;
&lt;P align=center&gt;Contact-wear allowance thickness&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;
&lt;P align=center&gt;Internal gas pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;Pa&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;≒1.33&#215;10‘&lt;SUP&gt;three&lt;/SUP&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=355&gt;
&lt;P align=center&gt;Allow storage period&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;P align=center&gt;year&lt;/P&gt;
&lt;P align=center&gt;Year&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;twenty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanical parameters for using circuit breakers&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;project&lt;/P&gt;
&lt;P align=center&gt;Project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;unit&lt;/P&gt;
&lt;P align=center&gt;Unit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;numerical value&lt;/P&gt;
&lt;P align=center&gt;Value&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;contact gap&lt;/P&gt;
&lt;P align=center&gt;Contact stroke&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;11&#177;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Contact stroke of contacts&lt;/P&gt;
&lt;P align=center&gt;Contact travel&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;3&#177;&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;0&lt;/SUB&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;
&lt;P align=center&gt;Average closing speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;0.6&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;
&lt;P align=center&gt;Average opening speed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;m/s&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;1.1&#177;0.2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;
&lt;P align=center&gt;Rated contact pressure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;4000&#177;300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;
&lt;P align=center&gt;Contact closing bounce time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Non synchronous closing and opening of contacts&lt;/P&gt;
&lt;P align=center&gt;Out of simultaneity of contact closing and opening&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;ms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=326&gt;
&lt;P align=center&gt;Rebound amplitude of the opening contact&lt;/P&gt;
&lt;P align=center&gt;Bouncing back amplitude of opening contact&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;≒2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201006/20100614205013448.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 421px; HEIGHT: 516px&quot; border=0 hspace=0 alt=&quot;Dimensions of Ceramic Vacuum Extinguishing Chamber for TD-12/2500-40 Circuit Breaker&quot; src=&quot;/upload2010/201006/20100614205013448.jpg&quot; width=421 height=516&gt;&lt;/A&gt;&lt;BR&gt;Ceramic vacuum arc extinguishing chamber for TD-12/2500-40 circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1600-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9230.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:56</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-40.5/1600-31.5 vacuum arc extinguishing chamber adopts copper chromium contact material, cup-shaped longitudinal magnetic field structure, stainless steel corrugated tube, ceramic shell and exposed shielding tube. The product has the characteristics of large breaking capacity, good insulation performance, and long mechanical life. Paired with corresponding vacuum circuit breakers, it can be widely used in power systems as a control and protection device for circuits, especially suitable for places with frequent operation.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV0&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and eighty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;170&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;320&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;twelve point eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-40.5/1600-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;25&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;2.0&#177;0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.8&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/2009111384340533.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 430px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1600-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/2009111384340533.jpg&quot; width=680 height=430&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-40.5/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9229.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:47</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-40.5/1250-31.5 vacuum arc extinguishing chamber adopts copper chromium contact material, cup-shaped longitudinal magnetic field structure, stainless steel corrugated tube, ceramic shell and exposed shielding tube. The product has the characteristics of large breaking capacity, good insulation performance, and long mechanical life. Paired with corresponding vacuum circuit breakers, it can be widely used in power systems as a control and protection device for circuits, especially suitable for places with frequent operation.&lt;BR&gt;&lt;BR&gt;Main technical parameters of TD-40.5/1250-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV0&lt;/TD&gt;
&lt;TD align=middle&gt;forty point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred and eighty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;170&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;320&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;twelve point eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;25&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;2.0&#177;0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.8&#177;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/200911138400871.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 420px&quot; border=0 hspace=0 alt=&quot;TD-40.5/1250-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138400871.jpg&quot; width=680 height=420&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Electric operating mechanism]DW17 Electric quick operating mechanism </title>
           <link>http://www.91way.com/info_en/26062.html</link>
           <author></author>
           <guid></guid>
           <category>Electric operating mechanism</category>
           <pubDate>2026-6-16 14:18:39</pubDate>
           <comments></comments>
           <description>DW17 electric quick operation mechanism&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-40 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9228.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:38</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;TD-12/2000-40 vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Paired with corresponding vacuum circuit breakers, it is particularly suitable for power distribution systems and frequently operated places in departments such as electricity, machinery, chemical engineering, metallurgy, and mining.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-180S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;210&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;300&#177;70&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;two point two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;six point six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;5000&#177;300&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138139854.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 360px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-40 vacuum arc extinguishing chamber external dimensions&quot; src=&quot;/upload2009/200911/200911138139854.jpg&quot; width=680 height=360&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/2000-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9227.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:30</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Matched with corresponding vacuum circuit breakers or vacuum distribution devices, it is particularly suitable for places where circuits are frequently operated in all working conditions of departments such as power, machinery, chemical, metallurgical, mining, etc.&lt;BR&gt;&lt;BR&gt;TD-12/2000-31.5 Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=236 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=63 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=197 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3 (0.5) S-HeFen-180S-HeFen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;210&#177;30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;300&#177;70&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;two point two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;six point six&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=600 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138949108.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;TD-12/2000-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138949108.jpg&quot; width=680 0=&quot;None&quot;&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-31.5 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9226.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:21</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;The TD-12/1250-31.5 vacuum arc extinguishing chamber adopts a corrugated ceramic shell, with copper chromium contacts and a cup-shaped longitudinal magnetic field structure. It has the advantages of large interruption capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments. Especially suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;thirty-one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;230&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point two six&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four point six five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/1250-31.5 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.85&#177;0.85&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;3100&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/200911138612326.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;TD-12/1250-31.5 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/200911138612326.jpg&quot; width=680 height=330&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/1250-25, TD-12/1250-25N vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9225.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:13</pubDate>
           <comments></comments>
           <description>Product Overview:&lt;BR&gt;&lt;BR&gt;TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers are equipped with corrugated ceramic shells, copper chromium contacts, and cup-shaped longitudinal magnetic field structures. It has the advantages of large interruption capacity, high insulation level, strong arc extinguishing ability, long service life, small size, simple maintenance, no explosion hazard, no pollution, and low noise. The indoor vacuum circuit breaker assembled with it is used for control and protection in the transmission and distribution systems of power, machinery, chemical, metallurgical, mining, railway and other departments. Especially suitable for places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;sixty-three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;240&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=85 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2500&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091113826405.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-12/1250-25 and TD-12/1250-25N vacuum arc extinguishing chambers&quot; src=&quot;/upload2009/200911/20091113826405.jpg&quot; width=680 height=330&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD-12/630-20B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/9224.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:18:04</pubDate>
           <comments></comments>
           <description>Overview:&lt;BR&gt;&lt;BR&gt;TD-12/630-20B vacuum arc extinguishing chamber is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and large creepage distance ceramic insulation shell. The product has the characteristics of small size, large breaking capacity, and high insulation level. Paired with corresponding indoor and outdoor vacuum circuit breakers, it is suitable for accompanying power systems in industrial sectors such as power, machinery, chemical, metallurgical, and mining, especially in places with frequent operations.&lt;BR&gt;&lt;BR&gt;Main technical parameters of vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=49 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=281 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;140&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;240&#177;50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒25&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one point one five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;Mechanism characteristics and parameters of vacuum switch equipment for TD-12/630-20B vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD width=98 align=middle&gt;unit&lt;/TD&gt;
&lt;TD width=232 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;11&#177;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2000&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112233517858.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 320px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD-12/630-20B vacuum arc extinguishing chamber&quot; src=&quot;/upload2009/200911/20091112233517858.jpg&quot; width=680 0=&quot;None&quot;&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZW8 Vacuum arc extinguishing chamber (ZW8 dedicated) </title>
           <link>http://www.91way.com/info_en/9223.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Overview:&lt;BR&gt;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) is a miniaturized product, using copper chromium contact material, cup-shaped longitudinal magnetic field structure, and glass or ceramic as insulation shell. The product has the characteristics of small size, large breaking capacity, and high pressure resistance. Paired with corresponding outdoor vacuum circuit breakers or vacuum distribution devices, it can be widely used in places where circuits are frequently operated in industrial sectors such as power, machinery, chemical, metallurgical, mining, etc.&lt;BR&gt;&lt;BR&gt;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=32 width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD height=32 align=middle&gt;unit&lt;/TD&gt;
&lt;TD height=32 width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;rated frequency&lt;/TD&gt;
&lt;TD align=middle&gt;Hz&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;forty-two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD align=middle&gt;kV&lt;/TD&gt;
&lt;TD align=middle&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD align=middle&gt;kA&lt;/TD&gt;
&lt;TD align=middle&gt;twenty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD align=middle&gt;S&lt;/TD&gt;
&lt;TD align=middle&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred and thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD align=middle&gt;A&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD align=middle&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;Fen-0.3S-180S-Fen&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated short-circuit breaking current breaking times&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;mechanical life&lt;/TD&gt;
&lt;TD align=middle&gt;time&lt;/TD&gt;
&lt;TD align=middle&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact self closing force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;95&#177;35&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;215&#177;40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;u次&lt;/TD&gt;
&lt;TD align=middle&gt;≒30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Thickness of allowable wear of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;Pa&lt;/TD&gt;
&lt;TD align=middle&gt;≒1&#215;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD align=middle&gt;kg&lt;/TD&gt;
&lt;TD align=middle&gt;three&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;The mechanism characteristics and parameters of the vacuum switch equipment matched with the product&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=32 width=254 align=middle&gt;parameter item&lt;/TD&gt;
&lt;TD height=32 align=middle&gt;unit&lt;/TD&gt;
&lt;TD height=32 width=157 align=middle&gt;parameter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;contact gap&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;8&#177;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average opening speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;1.1&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Average closing speed&lt;/TD&gt;
&lt;TD align=middle&gt;m/s&lt;/TD&gt;
&lt;TD align=middle&gt;0.6&#177;0.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD align=middle&gt;N&lt;/TD&gt;
&lt;TD align=middle&gt;2000&#177;200&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD align=middle&gt;ms&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=left&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD align=middle&gt;mm&lt;/TD&gt;
&lt;TD align=middle&gt;≒2&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112232337726.jpg&quot; target=_blank&gt;&lt;/A&gt;&lt;A href=&quot;http://www.91way.com/upload2009/200911/20091112232429802.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 420px&quot; border=0 hspace=0 alt=&quot;BD-12/630-20, TD-12/630-20W vacuum arc extinguishing chamber (ZW8 specific) external dimensions&quot; src=&quot;/upload2009/200911/20091112232429802.jpg&quot; width=680 height=420&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD14A-12/1250-31.5B Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/6820.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Introduction to TD14A-12/1250-31.5B vacuum arc extinguishing chamber:&lt;BR&gt;Overall Dimension Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200910/2009101885922198.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 449px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;Dimensions of TD14A-12/1250-31.5B vacuum arc extinguishing chamber&quot; src=&quot;/uploadfiles/200910/2009101885922198.jpg&quot; width=449 height=580&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=650 align=center cellpading=&quot;10&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TH scope=col&gt;parameter name&lt;/TH&gt;
&lt;TH scope=col&gt;parameter value&lt;/TH&gt;
&lt;TH scope=col&gt;unit&lt;/TH&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD&gt;forty-two&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;thirty-one point five&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;eighty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;thirty-one point five&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;O-0.3(0.5)s-CO-180s-CO&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current times&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;twenty thousand&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact self closing force&lt;/TD&gt;
&lt;TD&gt;140&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force at rated opening distance&lt;/TD&gt;
&lt;TD&gt;230&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;米次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Allowable wear thickness of contacts&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;zero point zero zero one&lt;/TD&gt;
&lt;TD&gt;Pa&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD&gt;one point four&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;four point seven&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;contact gap&lt;/TD&gt;
&lt;TD&gt;11&#177;1&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average opening speed&lt;/TD&gt;
&lt;TD&gt;1.1&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average closing speed&lt;/TD&gt;
&lt;TD&gt;0.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD&gt;3100&#177;200&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;outer diameter&lt;/TD&gt;
&lt;TD&gt;one hundred and six&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;installation height&lt;/TD&gt;
&lt;TD&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;appearance&lt;/TD&gt;
&lt;TD&gt;Umbrella skirt, climbing distance ≡ 240&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]TD21-40.5/1600-20 Vacuum arc extinguishing chamber </title>
           <link>http://www.91way.com/info_en/6818.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;TD21-40.5/1600-20 vacuum arc extinguishing chamber&lt;BR&gt;&lt;BR&gt;Product Introduction:&lt;BR&gt;Overall Dimension Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200910/2009101885418615.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 433px; HEIGHT: 580px&quot; border=0 hspace=0 alt=&quot;TD21-40.5/1600-20 External dimensions of vacuum arc extinguishing chamber&quot; src=&quot;/uploadfiles/200910/2009101885418615.jpg&quot; width=433 height=580&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TH&gt;parameter name&lt;/TH&gt;
&lt;TH&gt;parameter value&lt;/TH&gt;
&lt;TH&gt;unit&lt;/TH&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated voltage&lt;/TD&gt;
&lt;TD&gt;forty point five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated current&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;rated frequency&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Short term (1-minute) power frequency withstand voltage&lt;/TD&gt;
&lt;TD&gt;ninety-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Lightning impulse withstand voltage&lt;/TD&gt;
&lt;TD&gt;one hundred and eighty-five&lt;/TD&gt;
&lt;TD&gt;kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated peak withstand current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit closing current&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-time withstand current&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit duration&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated breaking current of a single capacitor bank&lt;/TD&gt;
&lt;TD&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated back-to-back capacitor bank breaking current&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated operating sequence&lt;/TD&gt;
&lt;TD&gt;O-0.3s-CO-180s-CO&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated short-circuit breaking current times&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;mechanical life&lt;/TD&gt;
&lt;TD&gt;ten thousand&lt;/TD&gt;
&lt;TD&gt;time&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact self closing force&lt;/TD&gt;
&lt;TD&gt;180&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact reaction force at rated opening distance&lt;/TD&gt;
&lt;TD&gt;300&#177;50&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Circuit resistance at lower limit of rated contact pressure&lt;/TD&gt;
&lt;TD&gt;twenty-five&lt;/TD&gt;
&lt;TD&gt;米次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Allowable wear thickness of contacts&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Gas pressure inside the vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;zero point zero zero one&lt;/TD&gt;
&lt;TD&gt;Pa&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of the sports section&lt;/TD&gt;
&lt;TD&gt;three point six seven&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality of vacuum arc extinguishing chamber&lt;/TD&gt;
&lt;TD&gt;twelve&lt;/TD&gt;
&lt;TD&gt;kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;contact gap&lt;/TD&gt;
&lt;TD&gt;22&#177;2&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average opening speed&lt;/TD&gt;
&lt;TD&gt;1.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Average closing speed&lt;/TD&gt;
&lt;TD&gt;0.6&#177;0.2&lt;/TD&gt;
&lt;TD&gt;m/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated contact pressure&lt;/TD&gt;
&lt;TD&gt;2500&#177;200&lt;/TD&gt;
&lt;TD&gt;N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Contact closing bounce time&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Non synchronous closing and opening of contacts&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;ms&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rebound amplitude of the opening contact&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;outer diameter&lt;/TD&gt;
&lt;TD&gt;one hundred and thirty-eight&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;installation height&lt;/TD&gt;
&lt;TD&gt;four hundred and fourteen&lt;/TD&gt;
&lt;TD&gt;mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;appearance&lt;/TD&gt;
&lt;TD&gt;Shielding tube exposed&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;TD21-40.5/1600-20 vacuum arc extinguishing chamber&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKBF-12/630-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2248.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;The ZKBF type vacuum switch tube uses high alumina glass as the insulating shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgical, textile, and high-rise buildings.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC high-voltage vacuum load switch, serving as protection and control for electrical facilities. Used for dividing and combining load current, closed-loop current, no-load transformer, and cable charging current.&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated voltage 12KV&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated peak withstand current 50KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Contact resistance under rated contact pressure ≒ 30 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;The allowable wear thickness of the contact is 3mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated active load breaking current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated short-circuit closing current 50KA&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Storage period of 20 years&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated closed-loop breaking current 630A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;Equipped with load switch FZN21-12D/T630-20 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated cable charging breaking current 10A&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Contact self closing force 190 &#177; 20N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot;&gt;Rated breaking no-load transformer capacity 1250KVA&lt;/TD&gt;
&lt;TD width=&quot;31%&quot;&gt;Contact reaction force at rated torque of 240 &#177; 24N&lt;/TD&gt;
&lt;TD width=&quot;37%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742120045462.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 248px&quot; border=0 hspace=0 alt=&quot;ZKBF-12/630-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742120045462.jpg&quot; width=509 height=248&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTDW-630/12-20 type vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2243.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:22</pubDate>
           <comments></comments>
           <description>The ZKTD vacuum switch tube adopts high alumina ceramic as the insulation shell, and is covered with high-strength corrugated insulation material on the outside. The tube uses high vacuum as the medium, so it is resistant to high voltage, has strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, textile, and high-rise buildings.&lt;BR&gt;This product, equipped with a suitable operating mechanism, can be assembled into an AC circuit breaker, used as a distribution device in three-phase AC power generation and supply systems, and as a centralized control device for electric motors.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated working voltage 10KV&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated short-time withstand time 4S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated working current 630A&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated power frequency withstand voltage 42KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-circuit breaking current 20KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Impulse withstand voltage 75KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-circuit breaking frequency 30 times&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Contact self closing force 100 &#177; 10N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated closing current (peak) 50KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Contact reaction force at rated opening distance of 140 &#177; 14N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated current breaking times 1000 times&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Rated contact pressure and contact resistance ≒ 100 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Mechanical lifespan of 100 million cycles&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Equipped with circuit breaker ZW8-12 type&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;45%&quot;&gt;Rated short-time withstand current 20KA&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421164342279.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 328px&quot; border=0 hspace=0 alt=&quot;ZKTDW-630/12-20 vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164342279.jpg&quot; width=275 height=328&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-630/10KV-I,II type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2242.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZKTD ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell, and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC circuit breaker for use in power distribution control devices, for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;Rated working voltage 10KV&lt;BR&gt;Rated working current 400, 630A&lt;BR&gt;Rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times&lt;BR&gt;Rated current breaking frequency 3000 times&lt;BR&gt;Mechanical lifespan of 15000 cycles&lt;BR&gt;Rated short-time withstand current 12.5KA&lt;BR&gt;Rated short-time withstand time 4S&lt;BR&gt;Rated power frequency withstand voltage 42KV&lt;BR&gt;Rated opening torque 8 &#177; 1mm&lt;BR&gt;Contact self closing force 115 &#177; 11N&lt;BR&gt;Contact reaction force at rated opening moment 140 &#177; 14N&lt;BR&gt;Contact resistance under rated contact pressure ≒ 100 米 次&lt;BR&gt;Type I is equipped with Jiyuan Circuit Breaker Type A&lt;BR&gt;Type II equipped with Jiyuan Circuit Breaker Type A&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/200742116427947.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 260px&quot; border=0 hspace=0 alt=&quot;ZKTD-630/10KV-I, II type ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742116427947.jpg&quot; width=509 height=260&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZKTD-630/10KV-I, II type ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-400(630)/6KV type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2241.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:17:04</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKTD ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell, and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into an AC circuit breaker for use in power distribution control devices, for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;BR&gt;Rated working voltage 6KV&lt;BR&gt;Rated working current 400, 630A&lt;BR&gt;Rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times&lt;BR&gt;Rated current breaking frequency 3000 times&lt;BR&gt;Mechanical lifespan of 15000 cycles&lt;BR&gt;Rated short-time withstand current 12.5KA&lt;BR&gt;Rated short-time withstand time 4S&lt;BR&gt;Rated power frequency withstand voltage 32KV&lt;BR&gt;Rated opening torque 4 &#177; 0.4mm, contact self closing force 115 &#177; 11N&lt;BR&gt;Contact reaction force at rated opening moment 140 &#177; 14N&lt;BR&gt;Contact resistance under rated contact pressure ≒ 100 米 次&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421164027341.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 509px; HEIGHT: 236px&quot; border=0 hspace=0 alt=&quot;ZKTD-400 (630)/6KV ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421164027341.jpg&quot; width=509 height=236&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-630/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2240.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;purpose&lt;BR&gt;The ZKTD-630/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;technical parameters&lt;BR&gt;Rated working voltage 1140V; rated working current 630A; rated short-circuit breaking current 12.5KA&lt;BR&gt;Rated short-circuit breaking frequency 16 times; Rated current breaking frequency 3000 times; Mechanical lifespan of 15000 cycles;&lt;BR&gt;Rated short-time withstand current 12.5KA; rated short-time withstand time 4S; rated power frequency withstand voltage 10KV&lt;BR&gt;The rated opening distance of the contact is 4 &#177; 0.4mm; the self closing force of the contact is 115 &#177; 11N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;BR&gt;Equipped with circuit breakers ZK1-630.&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;ZKTD-630/1140 Ceramic Vacuum Switch Tube Dimensions and Installation Dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163848370.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 315px; HEIGHT: 371px&quot; border=0 hspace=0 alt=&quot;ZKTD-630/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421163848370.jpg&quot; width=315 height=371&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-500/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2239.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:47</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;&lt;BR&gt;The ZKTD-500/1140 ceramic vacuum switch tube uses high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;ZKTD-500/1140 ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 530px&quot; border=0 cellSpacing=1 cellPadding=2 width=530 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 500A;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated short-circuit breaking current 9KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-circuit breaking frequency 16 times;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking frequency 3000 times;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Mechanical lifespan of 15000 cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-time withstand current 9KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand time of 4S;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated power frequency withstand voltage 10KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 100 &#177; 10N;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Equipped with circuit breaker ZN20-500 type.&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163727793.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 386px&quot; border=0 hspace=0 alt=&quot;ZKTD-500/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/2007421163727793.jpg&quot; width=275 height=386&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTD-400/1140 type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2238.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:39</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTD-400/1140 ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=2 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;
&lt;P&gt;Rated working voltage 1140V;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated working current 400A;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated short-circuit breaking current 8KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-circuit breaking frequency 16 times;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated current breaking frequency 3000 times;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Mechanical lifespan of 20000 cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Rated short-time withstand current 8KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-time withstand time of 4S;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;Rated power frequency withstand voltage 10KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Contact self closing force 115 &#177; 11N;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The reaction force at the rated opening distance of the contact is 140 &#177; 14N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 100 米 次;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;42%&quot;&gt;Equipped with circuit breaker ZN7-400 type.&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742116360155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTD-400/1140 Ceramic Vacuum Switch Tube Dimensions&quot; src=&quot;/uploadfiles/200704/200742116360155.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160-630/10KV( ｉ type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2237.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:30</pubDate>
           <comments></comments>
           <description>purpose&lt;BR&gt;ZKTJ-160-630/10KV (I) ceramic vacuum switch tube adopts high alumina ceramic as the insulation shell and high vacuum as the medium inside the tube. Therefore, it has a small volume, high voltage resistance, strong breaking ability, long service life, and does not require maintenance of the contacts. Especially due to its advantages of not exposing the arc and being safe and reliable, it is widely used in industrial sectors such as coal, power, chemical, metallurgy, and petroleum.&lt;BR&gt;ZKTJ-160-630/10KV (I) ceramic vacuum switch tube, equipped with a suitable operating mechanism, can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors, used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;
&lt;P&gt;Rated working voltage 10KV;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated working current of 160, 250, 400, 630A;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Rated connection capacity 1.6, 2.5, 4, 6.3KA, 100 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated breaking capacity 1.28, 2, 3.2, 5.04KA, 25 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Ultimate breaking capacity 160-400A 4.5KA 3 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Rated short-time withstand current 1.28, 2, 3.2, 5.04KA;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Rated short-circuit duration 10S&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Power frequency withstand voltage 32KV;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;Electric lifespan 100000 times&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Mechanical lifespan of 1 million cycles&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The rated opening distance of the contact is 4 &#177; 0.4mm;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Contact self closing force 85-125N;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The reaction force at the rated opening distance of the contact is 100-130N;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;The contact resistance under the self closing force of the contact is less than 120 米 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;51%&quot;&gt;Equipped with contactor CKG3-160-630A/10 type&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421163432353.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 315px; HEIGHT: 354px&quot; border=0 hspace=0 alt=&quot;ZKTJ-160-630/10KV (ｉ) type ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421163432353.jpg&quot; width=315 height=354&gt;&lt;/A&gt;&lt;BR&gt;ZKTJ-160-630/10KV (ｉ) type ceramic vacuum switch tube&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-630/6KV( ｊ) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2236.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:21</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters.&lt;BR&gt;&lt;BR&gt;Technical parameters of ZKTJ-630/6KV (II) ceramic vacuum switch tube&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px&quot; border=0 cellSpacing=1 cellPadding=3 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;
&lt;P&gt;Rated working voltage 6KV;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated working current 630A;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated connection capacity 6.3KA, 100 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Rated breaking capacity 5.04KA, 3 times;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Rated short-time withstand current 5.04KA;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Rated short-term duration of 4S;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Power frequency withstand voltage 23KV;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Electric lifespan 100000 times&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;Mechanical lifespan of 1 million cycles;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The rated opening distance of the contact is 3 &#177; 0.3mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;Contact self closing force 120 &#177; 12N;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The reaction force at the rated opening distance of the contact is 130 &#177; 13N;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;The allowable wear thickness of the contact is 1mm;&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;41%&quot;&gt;Equipped with contactor ZN6-600 type.&lt;/TD&gt;
&lt;TD width=&quot;29%&quot;&gt;&lt;/TD&gt;
&lt;TD width=&quot;30%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;ZKTJ-630/6KV (II) ceramic vacuum switch tube external dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200704/200742114515798.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 385px&quot; border=0 hspace=0 alt=&quot;ZKTJ-630/6KV (II) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/200742114515798.jpg&quot; width=275 height=385&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Ceramic arc extinguishing chamber]ZKTJ-160/6KV( ｊ) type ceramic vacuum switch tube </title>
           <link>http://www.91way.com/info_en/2235.html</link>
           <author></author>
           <guid></guid>
           <category>Ceramic arc extinguishing chamber</category>
           <pubDate>2026-6-16 14:16:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;ZKTJ and ZKTD ceramic vacuum switch tubes use high alumina ceramics as the insulation shell and high vacuum as the medium inside the tube. Therefore, they have small volume, high voltage resistance, strong breaking ability, long service life, and do not require maintenance of the contacts. Especially due to their advantages of not exposing the arc and being safe and reliable, they are widely used in industries such as coal, electricity, chemical, metallurgy, and petroleum.&lt;BR&gt;&lt;BR&gt;This product is equipped with a suitable operating mechanism and can be assembled into high, medium, and low voltage AC circuit breakers or AC contactors. It is used in high, medium, and low voltage distribution control devices for remote connection and disconnection of motors, transformers, capacitor banks, etc. It is particularly suitable for forming explosion-proof magnetic starters. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical parameters&lt;BR&gt;Rated working voltage 6KV; rated working current 160A; rated connection capacity 1.6KA, 100 times&lt;BR&gt;Rated breaking capacity of 1.28KA, 25 times; Ultimate breaking capacity of 4.5KA, rated short-time withstand current of 1.28KA for 3 times;&lt;BR&gt;Rated short-circuit duration of 10 seconds; power frequency withstand voltage of 23KV; electrical life of 100000 times&lt;BR&gt;Mechanical lifespan of 1 million cycles; The rated opening distance of the contact is 3 &#177; 0.3mm; the self closing force of the contact is 85 &#177; 100N;&lt;BR&gt;The reaction force at the rated opening distance of the contact is 100 &#177; 10N&lt;BR&gt;The contact resistance under the self closing force of the contact is ≒ 120 米 次&lt;BR&gt;The allowable wear thickness of the contact is 1mm&lt;BR&gt;Equipped with CZG1-160 contactor. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;External dimensions and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200704/2007421144717799.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 275px; HEIGHT: 375px&quot; border=0 hspace=0 alt=&quot;ZKTJ-160/6KV (II) ceramic vacuum switch tube external dimensions&quot; src=&quot;/uploadfiles/200704/2007421144717799.jpg&quot; width=275 height=375&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

