<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - 110KV voltage transformer</title>
       <link>http://www.91way.com</link>
       <description>110KV voltage transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:16:46</pubDate>
       <item>
           <title>[110KV voltage transformer]JDQHH-110 GIS 110kV single-phase voltage transformer </title>
           <link>http://www.91way.com/info_en/27675.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:38:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JDQHH-110 GIS 110kV single-phase voltage transformer is a GIS specific electromagnetic voltage transformer, which can be installed in three ways: forward, reverse, and horizontal.&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JSQHH-110 GIS 110kV three-phase voltage transformer </title>
           <link>http://www.91way.com/info_en/27674.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:37:58</pubDate>
           <comments></comments>
           <description>The JSQHH-110 GIS 110kV three-phase voltage transformer can be installed in three ways: forward, reverse, and horizontal. This type of voltage transformer has a compact structure and is easy to install. The main function is to provide voltage measurement, energy metering, and relay protection for the power system, in accordance with the national standard GB/T20840.3-2013 Supplementary Technical Requirements for Electromagnetic Voltage Transformers and the international standard IEC 61869-3:2011 Supplementary Requirements for Electromagnetic Voltage Transformers.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDQXF-66W2 High Voltage Voltage Transformer </title>
           <link>http://www.91way.com/info_en/24169.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of JDQXF-66W2 high-voltage voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204114807767.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 529px; HEIGHT: 134px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JDQXF-66W2 high-voltage voltage transformer&quot; src=&quot;/upload2013/201312/20131204114807767.jpg&quot; width=529 height=134&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;Outline drawing of JDQXF-66W2 high-voltage voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131204114819850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 405px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JDQXF-66W2 high-voltage voltage transformer&quot; src=&quot;/upload2013/201312/20131204114819850.jpg&quot; width=535 height=405&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDQXF-66W2 High Voltage Voltage Transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDQX3-126 gas insulated electromagnetic voltage transformer </title>
           <link>http://www.91way.com/info_en/20050.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:47</pubDate>
           <comments></comments>
           <description>JDQX3-126 gas insulated electromagnetic voltage transformer is designed to be used in conjunction with 72.5-126KV single-phase metal enclosed composite electrical appliances, and is the main component of metal enclosed composite electrical appliances. This product meets the national standards GB1208 and IEC185.&lt;BR&gt;&lt;BR&gt;Technical parameters of JDQX3-126 gas insulated electromagnetic voltage transformer:&lt;BR&gt;Rated primary voltage: 100/¡Ì 3KV&lt;BR&gt;Rated frequency: 50-60Hz&lt;BR&gt;Rated insulation level: 126/230/550KV&lt;BR&gt;Partial discharge level:&amp;lt;5pC&lt;BR&gt;Insulation medium: SF6&lt;BR&gt;Rated gas pressure: 0.4Mpa&lt;BR&gt;Minimum gas operating pressure: 0.35Mpa&lt;BR&gt;At zero gauge pressure, the power frequency withstand voltage of the primary winding is 110KV for 5 minutes&lt;BR&gt;Annual gas leakage rate:&amp;lt;0.5%&lt;BR&gt;Gas moisture content: £¼ 150ppm&lt;BR&gt;Accurate level combination:&lt;BR&gt;Accurate level combination:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;Winding category&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=middle&gt;Rated voltage ratio (KV)&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Accurate level combination&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Rated output capacity combination (VA)&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Secondary winding thermal limit output (VA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot; align=middle&gt;three-winding&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;300¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=&quot;11%&quot; align=middle&gt;Four windings&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;120¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.2¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;75¡Ã75¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;120¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDC7-110W High Voltage Voltage Transformer </title>
           <link>http://www.91way.com/info_en/17424.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:33</pubDate>
           <comments></comments>
           <description>JDC7-110W High Voltage Voltage Transformer&lt;BR&gt;&lt;BR&gt;
&lt;CENTER&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse; HEIGHT: 151px&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center height=151&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;JDC7-110W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Rated primary voltage kv&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=&quot;33%&quot; colSpan=2 align=middle&gt;Rated secondary voltage kV&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;measurement level&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;100/3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;protection level&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;110/3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;Remaining voltage&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=118 rowSpan=3 width=&quot;33%&quot; colSpan=2 align=middle&gt;Rated output and accuracy&lt;/TD&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;measurement level&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;75~100VA0.2 level&lt;BR&gt;150VA0.5 level&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;protection level&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;300VA3p level&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;33%&quot; align=middle&gt;Remaining voltage&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;200VA3p level&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Thermal limit load VA&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Rated voltage factor&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;1.6/30S&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=114 rowSpan=3 width=&quot;17%&quot; align=middle&gt;Power frequency withstand voltage kv&lt;/TD&gt;
&lt;TD width=&quot;49%&quot; colSpan=2 align=middle&gt;Primary winding to ground&lt;/TD&gt;
&lt;TD height=1 width=&quot;34%&quot; align=middle&gt;two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot; colSpan=2 align=middle&gt;One winding N terminal to ground&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;49%&quot; colSpan=2 align=middle&gt;Between secondary windings&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;two&lt;/TD&gt;&lt;/TR&gt;&lt;/CENTER&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;
&lt;P align=center&gt;Media loss rate%&lt;/P&gt;&lt;/TD&gt;
&lt;CENTER&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;&amp;lt;2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Partial discharge level pC&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;&amp;lt;10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Standard lightning voltage full wave impulse voltage kv&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;four hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Lightning carrier impulse voltage kV&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;five hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;sealing performance&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;0.2MPa no leakage&lt;BR&gt;(Test before installing the expander)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Creepage distance mm&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;2240 2865 3150&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;66%&quot; colSpan=3 align=middle&gt;Oil weight/total weight kg&lt;/TD&gt;
&lt;TD width=&quot;34%&quot; align=middle&gt;140/550&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/CENTER&gt;
&lt;P align=center&gt;&lt;BR&gt;Note: The secondary winding can be designed as two according to user needs, and the load and accuracy can be adjusted according to user needs.&lt;BR&gt;&lt;BR&gt;JDC7-110W High Voltage Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JED(S)H Series SF6 Gas Insulated Electronic Voltage Transformers </title>
           <link>http://www.91way.com/info_en/17303.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:25</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JED (S) H series SF6 gas insulated electronic voltage transformer is the development direction of instrument transformers. Compared with conventional instrument transformers, electronic transformers have a simpler insulation structure, smaller volume, and lighter weight; No iron core, no ferromagnetic resonance and other issues; Good anti electromagnetic interference performance; Large dynamic range and wide frequency response.&lt;BR&gt;&lt;BR&gt;1. The maximum voltage of the equipment is 72.5-550kV, with a rated frequency of 50/60Hz;&lt;BR&gt;2. The power frequency withstand voltage is 160-740kV, the full wave impulse withstand voltage is 320-1675kV, the cut-off impulse withstand voltage is 1930 kV, and the operating impulse withstand voltage is 1175 kV;&lt;BR&gt;3. Rated gas pressure ¡Ý 0.45Mpa;&lt;BR&gt;4. Secondary output: IEC 61850-9-1:2D41H&lt;BR&gt;IEC 61850-9-1: Primary voltage x 100&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110831185457611.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/upload2011/201108/20110831185457611.jpg&quot;&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;JED (S) H series SF6 gas insulated electronic voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDX-110 High Voltage Voltage Transformer </title>
           <link>http://www.91way.com/info_en/16709.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:17</pubDate>
           <comments></comments>
           <description>The JDX-110 voltage transformer is a fully sealed single-phase four winding oil paper insulation structure, with the body fixed in the oil tank. The upper and lower oil tanks are both circular structures. The porcelain sleeve is fixed on the upper part of the fuel tank with a pressure equalizing ring, and its top is equipped with a stainless steel expander, a primary wiring board, and an oil level indicator. The fuel tank is equipped with a pressure relief valve, and the lower part of the tank is equipped with a secondary outlet box, with an oil sample valve at the bottom.&lt;BR&gt;&lt;BR&gt;Main technical data of JDX-110 high-voltage voltage transformer:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;98%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;24%&quot;&gt;Rated voltage (KV)&lt;/TD&gt;
&lt;TD width=&quot;40%&quot;&gt;Primary winding (AN)&lt;/TD&gt;
&lt;TD colSpan=2&gt;110/¡Ì3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;40%&quot;&gt;Measure winding (1a1n)&lt;/TD&gt;
&lt;TD colSpan=2&gt;0.1/¡Ì3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;40%&quot;&gt;Protection winding (2a2n)&lt;/TD&gt;
&lt;TD colSpan=2&gt;0.1/¡Ì3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;40%&quot;&gt;Remaining voltage winding (dadn)&lt;/TD&gt;
&lt;TD colSpan=2&gt;zero point one&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Phase number, frequency (Hz)&lt;/TD&gt;
&lt;TD colSpan=2&gt;Single phase, 50&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;24%&quot;&gt;Accuracy level and rated output (VA) of secondary winding cos ¦µ=0.8&lt;/TD&gt;
&lt;TD rowSpan=3&gt;winding measurement&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;zero point two&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;one hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;zero point five&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;12%&quot;&gt;one&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;40%&quot;&gt;Protect the winding&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Accuracy level and rated output (VA) of residual voltage winding&lt;/TD&gt;
&lt;TD colSpan=2&gt;3P level, 300&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Secondary winding limit output (VA)&lt;/TD&gt;
&lt;TD colSpan=2&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Rated insulation level (KV)&lt;/TD&gt;
&lt;TD colSpan=2&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Partial discharge level (PC)&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Ü10&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JDX-110 High Voltage Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JSQX3-126 Gas Insulated Electromagnetic Voltage Transformer </title>
           <link>http://www.91way.com/info_en/7175.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:36:08</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product model: JSQX3-126&lt;BR&gt;&lt;BR&gt;Product features: JSQX3-126 gas insulated electromagnetic voltage transformer is designed for use with 72.5-126KV three-phase composite metal enclosed electrical appliances, and is the main component of metal enclosed electrical appliances. This product meets the national standards GB1208 and IEC185.&lt;BR&gt;&lt;BR&gt;Technical parameters of JSQX3-126 gas insulated electromagnetic voltage transformer:&lt;BR&gt;&lt;BR&gt;Rated primary voltage: 100/¡Ì 3KV&lt;BR&gt;Rated frequency: 50-60Hz&lt;BR&gt;Rated insulation level: 126/230/550KV&lt;BR&gt;Partial discharge level:&amp;lt;5pC&lt;BR&gt;Insulation medium: SF6&lt;BR&gt;Rated gas pressure: 0.4Mpa&lt;BR&gt;Minimum gas operating pressure: 0.35Mpa&lt;BR&gt;At zero gauge pressure, the power frequency withstand voltage of the primary winding is 110KV for 5 minutes&lt;BR&gt;Annual gas leakage rate:&amp;lt;0.5%&lt;BR&gt;Gas moisture content: £¼ 150ppm&lt;BR&gt;Accurate level combination:&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot; align=middle&gt;Winding category&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=middle&gt;Rated voltage ratio (KV)&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Accurate level combination&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Rated output capacity combination (VA)&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Secondary winding thermal limit output (VA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot; align=middle&gt;three-winding&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;300¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=&quot;11%&quot; align=middle&gt;Four windings&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;120¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.2¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;75¡Ã100¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;120¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;0.5¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;150¡Ã150¡Ã300&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;JSQX3-126 Gas Insulated Electromagnetic Voltage Transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDQX6-110 series high-voltage transformer </title>
           <link>http://www.91way.com/info_en/3627.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:58</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200851915213357.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 676px; HEIGHT: 190px&quot; border=0 hspace=0 alt=&quot;JDQX6-110 Series High Voltage Transformer Model Description&quot; src=&quot;/uploadfiles/200805/200851915213357.jpg&quot; width=676 height=190&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851915238333.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 217px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JDQX6-110 series high-voltage transformer&quot; src=&quot;/uploadfiles/200805/200851915238333.jpg&quot; width=680 height=217&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085191531745.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 743px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JDQX6-110 series high-voltage transformer&quot; src=&quot;/uploadfiles/200805/20085191531745.jpg&quot; width=650 height=743&gt;&lt;/A&gt;&lt;BR&gt;JDQX6-110 series high-voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDC6-110,JDCF-110 series high-voltage transformer </title>
           <link>http://www.91way.com/info_en/3623.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:50</pubDate>
           <comments></comments>
           <description>The JDC6-110 and JDCF-110 series high-voltage transformers are outdoor products with electromagnetic oil immersed paper composite insulation and fully sealed structure, suitable for voltage and energy measurement and relay protection in neutral point effective grounding systems with rated voltage of 110kV and rated frequency of 50-60Hz.&lt;BR&gt;
&lt;DIV&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 385px; HEIGHT: 238px&quot; border=0 hspace=0 alt=&quot;JDC6-110, JDCF-110 Series High Voltage Transformer Model Description&quot; src=&quot;/uploadfiles/200805/2008519144455935.jpg&quot; width=385 height=238&gt;&lt;/DIV&gt;&lt;BR&gt;3¡¢ Structure Introduction and Product Features&lt;BR&gt;The JDC6-110 and JDCF-110 series high-voltage transformers use oil immersed paper composite insulation and are fully enclosed outdoor products. This product has been carefully designed with low magnetic density, strong anti resonance ability, and low loss. The secondary winding can separate metering and protection, and can be specially designed for high loads according to user needs. Select stainless steel metal expander, adopt advanced vacuum drying and vacuum oil injection processing technology, with low medium loss and local discharge, ensuring the reliability of equipment operation&lt;BR&gt;&lt;BR&gt;4¡¢ The technical parameters of JDC6-110 and JDCF-110 series high-voltage transformers are shown in the table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;JDC6-110W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;JDCF-110W&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;The highest voltage of the equipment is kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Rated frequency Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;50~60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Power frequency withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Full wave impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Cut off impulse withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Dielectric loss factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;Overall ¡Ü 0.02, bracket ¡Ü 0.05&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Partial discharge amount pC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;¡Ü5&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Primary winding N terminal to secondary and ground frequency withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Secondary winding to ground power frequency withstand voltage kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Creepage distance mm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=324 colSpan=2&gt;
&lt;DIV align=center&gt;31503906, etc&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Rated voltage factor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;1.2 Continuous/1.5 30s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;1.2 Continuous/1.5 30s&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Rated voltage ratio kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;110/¡Ì3/0.1/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;110/¡Ì3/0.1/¡Ì3/0.1/¡Ì3/0.1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;0.2(0.5£¬3P)/3P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;0.2/0.5/3P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Rated output VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;150(300£¬500)/300&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;100/150/300&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=264&gt;
&lt;DIV&gt;Maximum output VA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=156&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;5¡¢ JDC6-110, JDCF-110 series high-voltage transformer appearance and installation dimensions&lt;BR&gt;&lt;BR&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 363px; HEIGHT: 405px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JDC6-110 and JDCF-110 series high-voltage transformers&quot; src=&quot;/uploadfiles/200805/2008519144519516.jpg&quot; width=363 height=405&gt;&lt;BR&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 236px; HEIGHT: 109px&quot; border=0 hspace=0 alt=&quot;Installation data for JDC6-110 and JDCF-110 series high-voltage transformers&quot; src=&quot;/uploadfiles/200805/2008519144539612.jpg&quot; width=236 height=109&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201905/20190512190610408.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 754px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JDC6-110 and JDCF-110 series high-voltage transformers&quot; src=&quot;/upload2019/201905/20190512190610408.jpg&quot; width=680 height=754&gt;&lt;/A&gt;&lt;BR&gt;JDC6-110, JDCF-110 series high-voltage transformers&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDQX¡õ-126 Gas Insulated Electromagnetic Voltage Transformer </title>
           <link>http://www.91way.com/info_en/3490.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:46</pubDate>
           <comments></comments>
           <description>Product model: JDQX ¡õ -126&lt;BR&gt;&lt;BR&gt;Product features: JDQX ¡õ -126 gas insulated electromagnetic voltage transformer is an outdoor independent gas insulated electromagnetic voltage transformer. This product meets the national standards GB1208 and IEC185. The insulation sleeve of the product can be suspended by customers with high-strength ceramic sleeves or silicone fiberglass sleeves.&lt;BR&gt;&lt;BR&gt;Technical parameters:&lt;BR&gt;Rated primary voltage: 100/¡Ì 3KV&lt;BR&gt;Rated frequency: 50-60Hz&lt;BR&gt;Rated insulation level: 126/230/550KV&lt;BR&gt;Partial discharge level:&amp;lt;5pC&lt;BR&gt;External insulation creepage distance: 3150mm (can be designed according to customer needs)&lt;BR&gt;External insulation arc flash distance: 1000mm (can be designed according to customer needs)&lt;BR&gt;Creepage distance/arc flash distance: 3.15&lt;BR&gt;Insulation medium: SF6&lt;BR&gt;Rated gas pressure: 0.4Mpa&lt;BR&gt;Minimum gas operating pressure: 0.35Mpa&lt;BR&gt;At zero gauge pressure, the power frequency withstand voltage of the primary winding is 110KV for 5 minutes&lt;BR&gt;Annual gas leakage rate:&amp;lt;1%&lt;BR&gt;Gas moisture content: £¼ 150ppm&lt;BR&gt;Accurate level combination:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;11%&quot; align=middle&gt;Winding category&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=middle&gt;Rated voltage ratio (KV)&lt;/TD&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Accurate level combination&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Rated output capacity combination (VA)&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;Secondary winding thermal limit output (VA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=60 rowSpan=2 width=&quot;11%&quot; align=middle&gt;three-winding&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;24%&quot; align=middle&gt;Based on customer confirmation&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 rowSpan=5 width=&quot;11%&quot; align=middle&gt;Four windings&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;22%&quot; align=middle&gt;110/¡Ì3¡Ã0.1/¡Ì3¡Ã0.1¡Ì3¡Ã0.1&lt;/TD&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.2¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD rowSpan=5 width=&quot;24%&quot; align=middle&gt;Based on customer confirmation&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.5¡Ã3P¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.2¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.2¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=30 width=&quot;19%&quot; align=middle&gt;0.5¡Ã0.5¡Ã3P&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;two thousand&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JDQX ¡õ -126 Gas Insulated Electromagnetic Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]TYD110 series high-voltage transformer </title>
           <link>http://www.91way.com/info_en/3545.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:41</pubDate>
           <comments></comments>
           <description>The TYD110 series high-voltage transformer is an outdoor product consisting of a capacitive voltage divider and an electromagnetic unit. It is suitable for voltage and energy measurement relay protection in neutral point effective grounding systems with a rated voltage of 110kV and a rated frequency of 50Hz.&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 472px; HEIGHT: 174px&quot; border=0 hspace=0 alt=&quot;TYD110 Series High Voltage Transformer Model Description&quot; src=&quot;/uploadfiles/200805/200851794721328.jpg&quot; width=472 height=174&gt;&lt;BR&gt;&lt;BR&gt;3¡¢ Structure Introduction and Product Features&lt;BR&gt;The TYD110 series high-voltage transformer consists of a capacitive voltage divider and an electromagnetic unit. The medium voltage terminal and low voltage terminal of the capacitive voltage divider are directly introduced into the oil tank containing the electromagnetic unit. The electromagnetic unit consists of an intermediate transformer, a compensating reactor, and a damper. The capacitive voltage divider consists of a ceramic sleeve, a capacitor core, capacitor oil, and a metal expander. The capacitor core is composed of several film paper composite media and aluminum foil wound components connected in series, and is subjected to vacuum impregnation treatment. Equipped with a metal expander to compensate for changes in oil volume with temperature. The secondary junction box is equipped with carrier communication terminals and overvoltage protection gaps.&lt;BR&gt;The mutual inductance adopts a speed saturation damping device, which has a fast transient response speed and can reliably dampen ferromagnetic resonance. The product has optimized the sealing structure and has good sealing performance.&lt;BR&gt;&lt;BR&gt;4¡¢ Technical parameters of TYD110 series high-voltage transformer&lt;BR&gt;Rated primary voltage: 110kV,&lt;BR&gt;The maximum voltage of the equipment is 126kV,&lt;BR&gt;Rated secondary voltage: 0.1/kV,&lt;BR&gt;Rated voltage of residual voltage winding: 0.1kV,&lt;BR&gt;The rated capacitance of the capacitive voltage divider (allowable deviation &#177; 5%) is shown in Table 1.&lt;BR&gt;&lt;BR&gt;Table 1&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;DIV align=center&gt;Product model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;TYD110/ -0.01H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;TYD110/ -0.02H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;TYD110/ -0.007H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;TYD110/ -0.015H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;DIV align=center&gt;High voltage rated capacitance C1 ¦Ì F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero one three one eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero two nine three three three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero zero nine one six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero two one nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;DIV align=center&gt;Medium voltage rated capacitance C2 ¦Ì F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero four two three five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero six two eight five seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero two nine six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero four seven three four&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;DIV align=center&gt;Rated capacitance of voltage divider CN ¦Ì F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero zero seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;zero point zero one five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=144&gt;
&lt;DIV align=center&gt;Rated voltage division ratio&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;four point two one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;three point one four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;four point two three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;three point one six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;The rated load (cos ¦Õ=0.8 hysteresis) and accuracy level are shown in Table 2.&lt;BR&gt;&lt;BR&gt;Table 2&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;DIV align=center&gt;Product Model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;TYD110/ -0.01H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;TYD110/ -0.02H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;TYD110/ -0.007H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;TYD110/ -0.015H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;DIV align=center&gt;Primary and secondary winding 1 #&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;80VA/0.2 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;150VA/0.2 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;80VA/0.2 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;150VA/0.2 level&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;DIV align=center&gt;Main and secondary winding 2 #&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;100VA/0.5 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;150VA/0.5 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;100VA/0.5 level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;150VA/0.5 level&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=120&gt;
&lt;DIV align=center&gt;Remaining voltage winding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;300VA/3P level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;300VA/3P level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;300VA/3P level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;300VA/3P level&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5¡¢ Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 472px; HEIGHT: 442px&quot; border=0 hspace=0 alt=&quot;TYD110 series high-voltage transformer installation dimensions&quot; src=&quot;/uploadfiles/200805/200851794639557.jpg&quot; width=472 height=442&gt;&lt;BR&gt;&lt;BR&gt;TYD110 series high-voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JCC6-110(W2),JCC6-110GYW2 series voltage transformer </title>
           <link>http://www.91way.com/info_en/3173.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:24</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085385928887.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 560px; HEIGHT: 1515px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JCC6-110 (W2) and JCC6-110GYW2 series voltage transformers&quot; src=&quot;/uploadfiles/200805/20085385928887.gif&quot; width=560 height=1515&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JCC6-110 (W2), JCC6-110GYW2 series voltage transformers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[110KV voltage transformer]JDQXF1-110W2(3) series outdoor dry-type SF6 electromagnetic voltage transformer </title>
           <link>http://www.91way.com/info_en/3172.html</link>
           <author></author>
           <guid></guid>
           <category>110KV voltage transformer</category>
           <pubDate>2026-6-20 11:35:15</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201303/20130302185912820.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 568px; HEIGHT: 1612px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JDQXF1-110W2 (3) series outdoor dry-type SF6 electromagnetic voltage transformer&quot; src=&quot;/upload2013/201303/20130302185912820.jpg&quot; width=568 height=1612&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;JDQXF-110/220-W2 sulfur hexafluoride voltage transformer&lt;BR&gt;Overview&lt;BR&gt;This type of voltage transformer is an SF6 gas insulated transformer, suitable for use in power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 110kV for energy metering, voltage monitoring, and relay protection&lt;BR&gt;Use it. This product complies with the standards of IEC60044-2:1997 and GB1207-1997 &quot;Voltage Transformers&quot;.&lt;BR&gt;&lt;BR&gt;Structure Introduction&lt;BR&gt;This type of voltage transformer is single-phase and consists of a primary output terminal, porcelain bushing, housing, and SF6 gas density relay (see attached figure). The primary output terminal and bursting disc are installed on the top of the product, and the winding&lt;BR&gt;The shielding body is installed inside the housing, and the density relay is installed on the housing.&lt;BR&gt;&lt;BR&gt;Technical parameters of JDQXF1-110W2 (3) series outdoor dry-type SF6 electromagnetic voltage transformer&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=4 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum voltage of equipment&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;rated voltage ratio&lt;BR&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Rated output (VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Maximum output (VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Frequency (Hz)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Altitude (m)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Total weight (kg)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;110/ 3/0.1/ 3/0.1/ 3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;50 or 60&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;110/ 3/0.1/ 3/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;JDQXF1-110W2 (3) series outdoor dry-type SF6 electromagnetic voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>