           <title>[industrial control equipment]SRS10 series, 0.25 level precision 32 step programmable PID controller </title>
           <link>http://www.91way.com/info_en/16054.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-19 10:03:09</pubDate>
           <comments></comments>
           <description>SRS10 series, 0.25 level precision 32 step programmable PID controller&lt;BR&gt;On the basis of summarizing years of successful experience in the Chinese market and absorbing suggestions from customers, Shimadzu Electric Company has launched the SRS10 series with ultra-high cost-effectiveness! A more stylish appearance! Ultra thin body, with a thickness of only 60mm&lt;BR&gt;&lt;BR&gt;Input/output isolation, sampling period of 0.25 seconds&lt;BR&gt;3 SV settings&lt;BR&gt;Multiple inputs and range of measurement&lt;BR&gt;0.25 level accuracy, 32 steps programmable (1-4 curves, 32-8 steps)! &amp;nbsp;&lt;BR&gt;RS-485 communication interface, Modbus/Shimaden protocol (optional)&lt;BR&gt;Rich functional options&lt;BR&gt;&lt;BR&gt;Non overshoot expert PID algorithm; 3 independent PID parameters; 4 independent set values; 3-channel event output; 4-channel switch input; Simulate transmission.&lt;BR&gt;32 step (8 steps x 4 steps) programmable function: can set the maximum 32 step rise/fall/insulation curve that can meet the majority of heat treatment processes&lt;BR&gt;Original MODBUS communication interface: It can achieve real-time digital communication between up to 31 instruments, and the master meter can send data to multiple slave meters in real time, making multi zone temperature control more accurate.&lt;BR&gt;New platinum resistor with a temperature range of -100.0 to 350.0 ⊥; Power on slow start; Manually adjust the output.&lt;BR&gt;Communication functions can be achieved using configuration software such as Kunlun Tongtai and Kingview.&lt;BR&gt;&lt;BR&gt;Selection Table for SHIMADEN SRS11 0.25 Level Programmable PID Regulator in Japan&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=67 colSpan=2&gt;
&lt;P align=center&gt;Model Code&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=550 colSpan=12&gt;
&lt;P&gt;Super bright dual four digit LED display, no overshoot expert PID algorithm, three independent PID parameters, AT self-tuning, manual/automatic disturbance free switching control, adjustable output limit, 3 event outputs, 3 independent set values, 3 switch inputs, 32 step programmable, analog transmission output, digital communication and other functions. Sampling period: 250ms. Front panel protection level IP66.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=67 colSpan=2&gt;
&lt;P align=center&gt;SRS11-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=550 colSpan=12&gt;
&lt;P&gt;Dimensions: Height 48 x Width 48 x Depth 68mm, Panel Hole Size: 45 x 45mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=67 colSpan=2&gt;
&lt;P&gt;input type&lt;BR&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=24&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=408 colSpan=10&gt;
&lt;P&gt;Thermocouples: B, R, S, K, E, J, T, N, PLII, WRe5-26, U, L&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=118&gt;
&lt;P&gt;Range see SRS11 Input Type and Measurement Range Comparison Table&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=408 colSpan=10&gt;
&lt;P&gt;Platinum resistance: Pt100/JPt100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=408 colSpan=10&gt;
&lt;P&gt;Voltage (mV): -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=24&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=408 colSpan=10&gt;
&lt;P&gt;Current (mA): 0-20mA, 4-20mA DC, Input Impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=408 colSpan=10&gt;
&lt;P&gt;Voltage (V): -1~1,0~1,0~2,0~5,1~5,0~10V DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=91 colSpan=3&gt;
&lt;P&gt;Adjust output 1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=502 colSpan=10&gt;
&lt;P&gt;Relay contact, capacity: 240V AC 2A/resistive, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=502 colSpan=10&gt;
&lt;P&gt;Solid state relay (SSR) drive, 12 &#177; 1.5V DC/30mA maximum, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=502 colSpan=10&gt;
&lt;P&gt;Current 4-20mA DC, load impedance: 600 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=502 colSpan=10&gt;
&lt;P&gt;Voltage 0-10V DC, load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=115 colSpan=4&gt;
&lt;P&gt;Adjust output 2 (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Relay contact, capacity: 240V AC 2A/resistive, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6 width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Current 4-20mA DC, load impedance: 600 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Solid state relay (SSR) drive, 12V &#177; 1.5V DC/30mA maximum, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Voltage 0-10V DC, load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=19&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96 colSpan=3&gt;
&lt;P&gt;Additional event output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;E-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Additional event output 1 point (EV3)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=19&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=96 colSpan=3&gt;
&lt;P&gt;Additional external input control signal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;D-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=466 colSpan=9&gt;
&lt;P&gt;Additional external control input 1 point (DI4)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=151 colSpan=5&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=430 colSpan=8&gt;
&lt;P&gt;100‵240V AC&#177;10%ㄛ50/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=430 colSpan=8&gt;
&lt;P&gt;24V AC/DC&#177;10%ㄛ50/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=187 colSpan=6&gt;
&lt;P&gt;Program functions (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=406 colSpan=7&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=406 colSpan=7&gt;
&lt;P&gt;Up to 4 segments, a total of 32 steps in the program&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=211 colSpan=7&gt;
&lt;P&gt;Event output (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=370 colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=370 colSpan=6&gt;
&lt;P&gt;Event output 2-point (EV1, EV2) contact capacity: 240V AC 1A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=247 colSpan=8&gt;
&lt;P&gt;Analog transmission/digital communication interface (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=334 colSpan=5&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=334 colSpan=5&gt;
&lt;P&gt;0‵10mV DC?? Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=334 colSpan=5&gt;
&lt;P&gt;4‵20mA DC?? Load impedance: 300 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=334 colSpan=5&gt;
&lt;P&gt;0‵10V DC??? Load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=334 colSpan=5&gt;
&lt;P&gt;RS485 (Shimaden Standard Protocol, MODBUS Protocol)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=283 colSpan=9&gt;
&lt;P&gt;External input control signal (DI)/CT input (optional)&lt;BR&gt;Attention: CT is sold separately&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;P&gt;CT input 2 points&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=214 colSpan=2&gt;
&lt;P&gt;Optional when adjusting output 1 or 2 to Y or P.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=298 colSpan=4&gt;
&lt;P&gt;External control input 3 points? (DI1, DI2, DI3)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=319 colSpan=10&gt;
&lt;P&gt;Special Notes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=262 colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=262 colSpan=3&gt;
&lt;P&gt;Yes (please consult in advance)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=63&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR73A/74A economical 0.3-level PID regulator </title>
           <link>http://www.91way.com/info_en/16066.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-19 10:02:05</pubDate>
           <comments></comments>
           <description>The small DCS control system composed of SR73A and SR74A economical instruments with communication interfaces and XF-2000 Chinese window configuration software can achieve PID adjustment of the circuit, real-time monitoring of the production process, and output various analysis reports, truly realizing the automation of the production process and the intelligence of quality management!&lt;BR&gt;&lt;BR&gt;Display: dual four digit seven segment digital display; 7 status lights; Measurement accuracy of 0.3% &#177; 1 word of full range; Sampling period is 0.5 seconds.&lt;BR&gt;Free input: 11 types of thermocouples can be selected; 8 types of platinum resistors; 6 voltage inputs and 4-20mA current inputs.&lt;BR&gt;Adjustment algorithm: A non overshoot expert PID algorithm designed for the heat treatment industry. The anti overshoot suppression coefficient can be set.&lt;BR&gt;Adjust output: SSR solid-state relay output; 4-20mA and 0-10V linear output; Contact output.&lt;BR&gt;Input filtering time constant: used to reduce measurement value jumping caused by disturbances in the industrial field and stabilize measurement value display.&lt;BR&gt;Measurement value compensation: Correction values can be set for measurement errors of instruments and sensors or errors caused by excessively long sensor wires.&lt;BR&gt;Alarm output: Two independent alarm relays; Heater disconnection alarm; Users can set eight types of alarms for absolute/deviation.&lt;BR&gt;Set value offset: Two set values inside the machine can be selected through the external SB terminal of the instrument, suitable for day/night temperature difference and insulation control.&lt;BR&gt;DC linear input programmable digital display range: can set engineering quantity display units from -1999 to 9999, with decimal point position.&lt;BR&gt;Manual adjustment of output: The automatic/manual switching within the proportional band can be completed without disturbance through the manual keys on the panel.&lt;BR&gt;Adjust output limit: The upper and lower limits of the output amplitude can be set separately, the size and opening of the valve can be limited, and the heating power can be limited.&lt;BR&gt;Power on slow start protection: The power on output increases at a slope of 1-100 seconds to reduce load impact and protect power components.&lt;BR&gt;Adjustment execution and offline: The panel allows for easy selection of automatic adjustment of the instrument or measurement display without output.&lt;BR&gt;Proportional cycle setting: P and Y-shaped output instruments can have output proportional cycles set to match heating devices and adjust resolution.&lt;BR&gt;&lt;BR&gt;The most distinctive communication function (optional):&lt;BR&gt;&lt;BR&gt;A wider address range: Instrument addresses range from 0 to 99, allowing up to 100 instruments to be connected to the same network.&lt;BR&gt;Baud rate: 1200240048009600 can be set; Binary block check and parity check.&lt;BR&gt;A concise ASC code communication protocol: special guide symbols are used to distinguish other communication devices (such as PLCs) on the network&lt;BR&gt;&lt;BR&gt;SR73A/74A Regulator Selection Table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; TEXT-ALIGN: center&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;project&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;code&lt;/TD&gt;
&lt;TD colSpan=5&gt;Double four digit digital display, measurement accuracy of &#177; 0.3% of full range+1 word, sampling twice per second, self-tuning PID parameters. Equipped with manual, power on slow start, adjustable output limit, and no overshoot expert PID&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;6%&quot;&gt;1. Type&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;SR73A-&lt;/TD&gt;
&lt;TD colSpan=5&gt;DIN standard height 96 x width 96 x depth 110mm opening size: 92 x 92mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;8%&quot;&gt;SR74A-&lt;/TD&gt;
&lt;TD colSpan=5&gt;Standard 96 &#215; 48 &#215; 110mm 92 &#215; 45mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=2&gt;2. Input type and measurement range. The display range and decimal point position of DC input type can be set&lt;/TD&gt;
&lt;TD height=102 width=&quot;6%&quot;&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=102 colSpan=4&gt;Thermocouples: 11 types, 22 measurement ranges (Hua Shi omitted): B: 0‵1800 R: 0‵1700S: 0‵1700 K1: -100‵400 K2: 0‵1200 E: 0‵700 J: 0‵600T: -199.9‵200.0 N: 0‵1300 U: -199.9‵200.0 L: 0‵600 ⊥. Platinum resistance: Pt100 or JPt100 standard, with 16 measurement ranges (Hua Shi omitted): -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥. Millivolt voltage: 0-10, 10-50, 0-100; The display range can be set from -1999 to 9999.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;four&lt;/TD&gt;
&lt;TD colSpan=4&gt;Current: 4-20mA accepts impedance of 250 次; The display range can be set from -1999 to 9999.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;six&lt;/TD&gt;
&lt;TD colSpan=4&gt;Voltage (V): 0-1,1-5,0-10; The display range can be set from -1999 to 9999.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;3. Adjust the output type (adjustment methods: PID, PD, PI, P, and positional)&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;P&lt;/TD&gt;
&lt;TD colSpan=3&gt;Solid state relay SSR driving voltage output: proportional period 1-120 seconds can be set; Level: 15V &#177; 3VDC/20mA (at 1.5K load)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;Y&lt;/TD&gt;
&lt;TD colSpan=3&gt;Relay contact: proportional cycle 1-120 seconds can be set; 240VAC: 2.5A/pure resistance 1A/inductive load.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;I&lt;/TD&gt;
&lt;TD colSpan=3&gt;Linear current output: 4-20mA DC, output impedance below 600 次.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;V&lt;/TD&gt;
&lt;TD colSpan=3&gt;Linear voltage output: 0-10V DC, load current below 2mA.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=4&gt;
&lt;P&gt;4. Alarm and option types&lt;/P&gt;
&lt;P&gt;The independent upper and lower limit alarm relay output is the basic configuration, and four alarm modes can be set.&lt;/P&gt;
&lt;P&gt;Single phase heater disconnection alarm (optional) Note: Only applicable to Y1 or P1 output type instruments&lt;/P&gt;
&lt;P&gt;SB set value offset (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=47 width=&quot;5%&quot;&gt;one&lt;/TD&gt;
&lt;TD height=47 colSpan=2&gt;Independent upper and lower limit alarm relay contact capacity: 240VAC 1.5A (pure resistance).&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;three&lt;/TD&gt;
&lt;TD colSpan=2&gt;Upper and lower limit alarm+wire breakage alarm (detection from 0.0 to 50.0A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;five&lt;/TD&gt;
&lt;TD colSpan=2&gt;Upper and lower limit alarm+SB set value offset (dual set value)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;A&lt;/TD&gt;
&lt;TD colSpan=2&gt;Upper and lower limit alarm+special disconnection alarm (0-5VDC input)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=5&gt;5. Isolation digital communication interface option type, communication distance up to 1.2 kilometers, can link up to 100 instruments&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;0&lt;/TD&gt;
&lt;TD width=&quot;63%&quot;&gt;No interface&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;five&lt;/TD&gt;
&lt;TD width=&quot;63%&quot;&gt;RS - 485&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot;&gt;six&lt;/TD&gt;
&lt;TD width=&quot;63%&quot;&gt;RS - 422A&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR73A/74A economical 0.3-level PID regulator&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR253 0.1 Level PID Regulator </title>
           <link>http://www.91way.com/info_en/16062.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-19 10:01:20</pubDate>
           <comments></comments>
           <description>SR253 is the successor product of the high-precision SR25 PID controller from Shimadzu Electric in Japan. It has a five digit display, high resolution of 0.1 (with decimal point for temperatures above 1000 degrees) and 0.001 (platinum resistance range of 0.000 to 50.000), and an adjustable resolution of 1/8000. Equipped with a large LCD display screen, displaying four rows of data simultaneously. The new features include: adopting the Island Electric patent's no overshoot expert PID new algorithm, improving the instrument's ability to resist overshoot and overshoot, and suppressing disturbances; The PID parameters can automatically follow the PID algorithm of the set area; Self setting point limit to prevent processing materials from overheating; External control is involved in regulating output operations to achieve feedback control of the load; Dual output room temperature point adjustment conversion function, etc. As a high-precision instrument, it can be widely used in semiconductor manufacturing, instrument measurement, sensor calibration, environmental testing equipment, petrochemical, metallurgical and other self-control fields.&lt;BR&gt;&lt;BR&gt;Ten independent pre-set settings. Twenty sets of independent PID parameters corresponding to dual outputs, as well as twenty sets of adjustable output limits. The set value can be selected internally or externally.&lt;BR&gt;&lt;BR&gt;The external remote control setting function can also participate in adjustment (cascade control, non isolated standard configuration/isolated type optional), and multiple SR253s can be combined with programmable FP21 set value transmission to form a multi zone temperature control system. The control method of external remote control involves the calculation of output to meet the requirements of load feedback control.&lt;BR&gt;&lt;BR&gt;Isolated digital communication interface (optional), can be configured with RS232C, RS422A, RS485 interfaces, port addresses 0-99, multiple communication protocols. We can also provide a Himanton optical isolation intelligent 232-422-485 communication converter, which can be combined with XF-2000 Chinese window configuration software to form a small distributed system with the upper computer (note: 6-year usage history)&lt;BR&gt;&lt;BR&gt;Second output function (optional), two sets of outputs with opposite or the same polarity, used for heating/cooling regulation, or main and auxiliary control with the same polarity. It has independent PID parameters and output limiting, thus overcoming the difficulties at room temperature conversion points (involving action polarity and output quantity). (Mainly used for environmental testing equipment with a wide temperature range)&lt;BR&gt;&lt;BR&gt;Three sets of independent event relays (optional), capable of setting 19 types of events, including: upper and lower limit deviation values, deviation values outside/inside, absolute values of upper and lower limits, upper and lower limit alarms for set values, self-tuning, manual adjustment, external remote control, slope operation, offline control, measured values, external remote control exceeding range, output polarity transition, and heater disconnection.&lt;BR&gt;&lt;BR&gt;External digital input/output (optional): Eight sets of voltage free contact DI input/five sets of DO OC gate output. Four sets of DI can be connected to BCD code to select SV value, and the other four sets can define eight functions, including self-tuning, manual, external remote control, slope operation/stop, offline control, and polarity conversion adjustment. Convenient for PLC program control.&lt;BR&gt;&lt;BR&gt;0-10mV, 0-10V, 4-20mA isolated analog transmission output (optional). Type: measured value, set value, deviation value, adjustable output transmission.&lt;BR&gt;&lt;BR&gt;Single phase heater disconnection and heating circuit alarm (optional): current monitoring range: 0.0~55.0A, with 1 current transformer attached with the table.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=10&gt;
&lt;P&gt;Measurement value five digit digital display, 17 status lights, accuracy &#177; 0.1% FS, large LCD screen (21 characters and 4 lines) sampling 5 times/second&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P&gt;1. Appearance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;SR253-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=10&gt;
&lt;P&gt;DIN standard: height 96 x width 96 x depth 125mm, panel opening size 92 x 92mm, power supply: 100~240Vac 15W&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=2&gt;
&lt;P&gt;2. Input type and&lt;/P&gt;
&lt;P&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=10&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;Thermocouple: 19 types to choose from, -200.0~2300.0 ⊥, see the division selection table for details, input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=10&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;Platinum resistance: 16 measurement ranges are available, ranging from -200.0 to 600.0 ⊥. Please refer to the division selection table on the flowchart for details. Three wire system&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=10&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;DC millivolts 0-10, 10-50, -10 to 10, 0-20, 0-50, 0-100, -100 to 100 Input impedance:&amp;gt;500K&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=10&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;DC current: 4-20mA, 0-20mA, input impedance: 250 次 DC input programmable range: -19999-26000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=10&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;DC voltage: 0-1,1-5, -1-1,1,0-2,5,0-10, -10-10V Input impedance:&amp;gt;500K 次, decimal point arbitrary&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;
&lt;P&gt;3. Adjust output type 1&lt;/P&gt;
&lt;P&gt;Positive and negative effects can be set (two working modes)&lt;/P&gt;
&lt;P&gt;Resolution 1/8000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=16&gt;
&lt;P&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Relay contact, time proportional cycle 1~200 seconds, contact: 240V AC 2.5A resistive/1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Current 4-20mA, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Solid state relay drive, with a time proportional cycle of 1-200 seconds, 12 &#177; 2V DC&amp;lt;30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=16&gt;
&lt;P&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 colSpan=8&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=4&gt;
&lt;P&gt;4. Adjust the output to two types&lt;/P&gt;
&lt;P&gt;Positive and negative effects can be set&lt;/P&gt;
&lt;P&gt;(Four working modes)&lt;/P&gt;
&lt;P&gt;(Optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=16&gt;
&lt;P&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Relay contact, proportional cycle 1~200 seconds, contact: 240V AC 2.5A resistive/1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Current 4-20mA, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Solid state relay drive, proportional cycle 1~200 seconds, 12V &#177; 2 DC&amp;lt;30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=16&gt;
&lt;P&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 colSpan=7&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=5&gt;
&lt;P&gt;Event output (19 types of alarms and statuses)&lt;/P&gt;
&lt;P&gt;Heater disconnection/loop alarm (single-phase only) (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=8&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=8&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;3 sets of event outputs, contact: 240V AC 1.5A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=8&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;3 sets of event outputs and 30A heater disconnection alarm (only Y and P output types are optional)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=14 width=8&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=14 colSpan=6&gt;
&lt;P&gt;3 sets of event outputs and 50A heater disconnection alarm (only Y and P output types are optional)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 colSpan=6&gt;
&lt;P&gt;6. Simulate external remote control setting types&lt;/P&gt;
&lt;P&gt;(Isolation as an option)&lt;/P&gt;
&lt;P&gt;Purpose: Cascade control, external feedback for load regulation (with external sensors to achieve constant voltage, constant current, and constant power control)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;06&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;0-10V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;04&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;4-20mA DC input, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;05&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;1-5V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;4-20mA DC input, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;1-5V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;0-10V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=7 colSpan=7&gt;
&lt;P&gt;7. Isolation analog transmission output type&lt;/P&gt;
&lt;P&gt;(Optional)&lt;/P&gt;
&lt;P&gt;Transmission type: measured value, set value, deviation value, adjustable output quantity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=16&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10mV DCㄛ Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=88&gt;
&lt;P&gt;Single transmission output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;4‵20mA DCㄛ Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10V DCㄛ Load current&amp;lt;1mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10mV DCㄛ Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=88&gt;
&lt;P&gt;Dual transmission output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;4‵20mA DCㄛ Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10V DCㄛ Load current&amp;lt;1mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=8&gt;
&lt;P&gt;8. 8 external digital inputs/5 digital outputs (DI/DO) (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23 width=38&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=23 colSpan=3&gt;
&lt;P&gt;4 BCD codes SV number selection, 4 sets of DI, 5 sets of DO, 24 pin plug&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=9&gt;
&lt;P&gt;9. Isolation of digital communication interface types with multiple protocols (optional)&lt;/P&gt;
&lt;P&gt;Supporting product: XF2000 configuration software Himanton optical isolation RS232-422/485 converter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=13&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=13&gt;
&lt;P&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;RS-485&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=13&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;RS-422A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=13&gt;
&lt;P&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;RS-232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR253 High Resolution, High Performance, High Precision, Class 0.1 PID Regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]FP21 high-precision 0.1 programmable segment PID regulator </title>
           <link>http://www.91way.com/info_en/16063.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-19 10:00:37</pubDate>
           <comments></comments>
           <description>The high-precision FP21 programmable PID controller from Shimadzu Corporation in Japan is a classic design among high-end regulator products. It has been launched in the Chinese market for ten years and has been enduring for a long time. Its perfect design, powerful functions, and highly reliable control quality still occupy an unparalleled position today.&lt;BR&gt;&lt;BR&gt;High precision:+0.1% FS, four digit digital display, LCD display.&lt;BR&gt;Programmable: 9 curves, each with 9 segments, each curve can be linked to each other, with a maximum of 81 segments.&lt;BR&gt;9 sets of PID, 9 sets of adjustable output limiting, 4 sets of time event output, PID self-tuning, adjustable output with optional positive and negative effects&lt;BR&gt;Thermocouples, platinum resistors, voltage, and current with multiple input ranges to choose from&lt;BR&gt;DC input display range is programmable&lt;BR&gt;Two sets of simulated remote control outputs&lt;BR&gt;Convenient external switch for users&lt;BR&gt;Absolute values of upper and lower limits, deviation values, and multiple event alarm methods&lt;BR&gt;&lt;BR&gt;Equipped with RS232/RS422 communication interface&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;HEIGHT: 920px; WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; height=920 cellSpacing=2 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top colSpan=2&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=6&gt;
&lt;P align=center&gt;technical performance&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=12 colSpan=2&gt;
&lt;P align=center&gt;FP21&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=12 vAlign=top colSpan=6&gt;
&lt;P&gt;9 sets of 9-segment programmable regulators, PID automatic tuning, high-precision 0.1% FS &#177; 1 word, DIN 96 &#215; 96 &#215; 140mm, 9 sets of PID and 9 sets of amplitude limiting, servo starting, ensuring platform, with LCD screen curve and status display, convenient external switch quantity for operation, three PID algorithms, with 4 sets of sequential control time scales. The basic configuration includes three time scales and two upper/lower limit alarm relays, 10 isolated outputs, and 8 isolated inputs&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=32&gt;
&lt;P align=center&gt;input&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 vAlign=top width=26&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 vAlign=top colSpan=6&gt;
&lt;P&gt;Thermocouple type, 15 types of thermocouples to choose from, temperature range -200~2300 ⊥&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top width=26&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=6&gt;
&lt;P&gt;Platinum resistance type (Pt100): 8 optional ranges, temperature range -200~600 ⊥&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top width=26&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=6&gt;
&lt;P&gt;DC voltage type: Users can choose from 0 to 10; 0‵20˙ 0‵50˙ 0‵100˙ 10‵50˙ -10‵+10mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=4 vAlign=top width=26&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=4 vAlign=top colSpan=6&gt;
&lt;P&gt;DC current type: Users can choose 4-20, 0-20mA linear input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=6 vAlign=top width=26&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=6 vAlign=top colSpan=6&gt;
&lt;P&gt;DC voltage type: Users can choose 0-1, 0-2, 0-5, 0-10, 1-5, -1 to+1V DC linear input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P align=center&gt;isolation&lt;/P&gt;
&lt;P align=center&gt;control&lt;/P&gt;
&lt;P align=center&gt;output&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 vAlign=top width=26&gt;
&lt;P&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=9 vAlign=top colSpan=5&gt;
&lt;P&gt;Relay contact: Time proportional cycle 1-120 seconds, 240V AC 2.5A/pure resistance, 1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=12 vAlign=top width=26&gt;
&lt;P&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=12 vAlign=top colSpan=5&gt;
&lt;P&gt;Current output: 4-20mA DC, load resistance=600 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top width=26&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=5&gt;
&lt;P&gt;Solid state relay (SSR) output: Time proportional cycle 1-120 seconds, 15V DC/20mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=14 vAlign=top width=26&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=14 vAlign=top colSpan=5&gt;
&lt;P&gt;Voltage output: 0-10V DC, load current=2mA/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=7 colSpan=3&gt;
&lt;P align=center&gt;Isolation module&lt;/P&gt;
&lt;P align=center&gt;Proposed to send&lt;/P&gt;
&lt;P align=center&gt;(Set PV or SV values inside the machine)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top width=33&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=13 vAlign=top width=33&gt;
&lt;P&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=13 vAlign=top colSpan=3&gt;
&lt;P&gt;0-10mV DC output impedance 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=142&gt;
&lt;P&gt;Single output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=12 vAlign=top width=33&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=12 vAlign=top colSpan=3&gt;
&lt;P&gt;4-20mA DC load resistance=500 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=21 vAlign=top width=33&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 vAlign=top colSpan=3&gt;
&lt;P&gt;0-10V DC load current=2mA/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=20 vAlign=top width=33&gt;
&lt;P&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=20 vAlign=top colSpan=3&gt;
&lt;P&gt;0-10mV DC output impedance 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=142&gt;
&lt;P&gt;dual output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=14 vAlign=top width=33&gt;
&lt;P&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=14 vAlign=top colSpan=3&gt;
&lt;P&gt;4-20mA DC load resistance=500 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top width=33&gt;
&lt;P&gt;twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=3&gt;
&lt;P&gt;0-10V DC load current=2mA/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=4&gt;
&lt;P align=center&gt;communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top width=27&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 vAlign=top width=27&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 vAlign=top colSpan=3&gt;
&lt;P&gt;RS-422A communication distance is 1.2 kilometers (one link can control 10 units)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=7 vAlign=top width=27&gt;
&lt;P&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=7 vAlign=top colSpan=3&gt;
&lt;P&gt;RS-232Cㄛ Communication distance of 15 meters (point-to-point)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=2 colSpan=5&gt;
&lt;P align=center&gt;External I/O&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=27&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 colSpan=2&gt;
&lt;P&gt;24 pin plug&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;FP21 high-precision 0.1 level programmable 81 segment PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]ZAC10-P/I Type SSR Intelligent Controller </title>
           <link>http://www.91way.com/info_en/16073.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:42:20</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;ZZAC10 Explanation&lt;BR&gt;ZAC10-P/I SSR Intelligent Controller&lt;BR&gt;&lt;BR&gt;Adjust stable, energy-saving, load balancing with manual and internal power limit PL, with a mandatory power limit of 40%&lt;BR&gt;60 second power on slow start, single-phase and three-phase universal, no phase sequence, DIN rail or screw installation&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110405180102633.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 495px; HEIGHT: 720px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of ZAC10-P/I SSR intelligent controller&quot; src=&quot;/upload2011/201104/20110405180102633.jpg&quot; width=495 height=720&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Five applied technology&lt;BR&gt;1) The simplest wiring for ZAC10 and solid-state SSR drivers without manual operation&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405180130702.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 595px; HEIGHT: 248px&quot; border=0 hspace=0 alt=&quot;ZAC10-P/I SSR Intelligent Controller Wiring Diagram&quot; src=&quot;/upload2011/201104/20110405180130702.gif&quot; width=595 height=248&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;2) Manual and PL special automatic power limit usage methods for ZAC10&lt;BR&gt;PL is a normally open input with no voltage contact. In automatic mode, when PL is closed, the maximum output power is fixed within 40%,&lt;BR&gt;The internal auxiliary power limit setting value has failed. Purpose: Power limitation and balanced starting: If the load design is unreasonable, the cold starting of high-power silicon carbide rod heaters (can only limit power, cannot limit current) or avoid power imbalance caused by multiple devices switching at the same time. It can be manually connected to a single pole switch to limit 40% Power is then withdrawn in a time-sharing manner. Ｌ Different alarm points with different lower limits for island electrical instruments can be set up to achieve time-sharing starting.&lt;BR&gt;3) Internal MS output mode jumper selection&lt;BR&gt;1) When used alone, PWM duty cycle output is generally selected. 2) When used in multiple units, use cyclic CYC output.&lt;BR&gt;Explanation: Changing the output working mode requires re powering on to confirm.&lt;BR&gt;VI Ordering instructions and accessories&lt;BR&gt;Enter P, model ZAC10-P; Input 4-20mA, model ZAC10-I. Note: Distinguish by the input symbol P or I on the product label.&lt;BR&gt;One instruction manual, one manual potentiometer and one dial.&lt;BR&gt;&lt;BR&gt;ZAC10 selection and size&lt;BR&gt;Optical isolation input P-type: pulse width modulation (duty cycle) pulse, period: 2 seconds; High level: 4-15V; Low level: 1.5V;&lt;BR&gt;Maximum input current:&amp;lt;20mA photoisolation voltage&amp;gt;2KV DC (one second test)&lt;BR&gt;4~20mA input type I: accepts impedance&amp;lt;250 ohms. Adaptation interface: Japanese Shimada P or I type PID regulator or DCS output interface.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110405180320565.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 441px; HEIGHT: 249px&quot; border=0 hspace=0 alt=&quot;Dimensions of ZAC10-P/I SSR Intelligent Controller&quot; src=&quot;/upload2011/201104/20110405180320565.gif&quot; width=441 height=249&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405180333368.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 521px; HEIGHT: 267px&quot; border=0 hspace=0 alt=&quot;Assembly drawing of ZAC10-P/I SSR intelligent controller&quot; src=&quot;/upload2011/201104/20110405180333368.gif&quot; width=521 height=267&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]TAC20-Z type SCR short circuit/open circuit alarm </title>
           <link>http://www.91way.com/info_en/16072.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:42:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110405175540120.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 735px&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of TAC20-Z SCR Short Circuit/Open Circuit Alarm Device&quot; src=&quot;/upload2011/201104/20110405175540120.jpg&quot; width=500 height=735&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405175552804.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 495px; HEIGHT: 670px&quot; border=0 hspace=0 alt=&quot;Installation diagram of TAC20-Z SCR short circuit/open circuit alarm&quot; src=&quot;/upload2011/201104/20110405175552804.jpg&quot; width=495 height=670&gt;&lt;/A&gt;&lt;BR&gt;TAC20-Z SCR Short Circuit/Open Circuit Alarm&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR1/3/4 series self-tuning PID regulator </title>
           <link>http://www.91way.com/info_en/16068.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:42:02</pubDate>
           <comments></comments>
           <description>SR1/3/4 self-tuning PID regulator&lt;BR&gt;&lt;BR&gt;SR1/SR3/SR4 are the latest technological products of Shimada Electric Company in 2003. They summarize the application experience of SR60 to SR70 series regulators and highlight the design concept of economic practicality, simple operation, and complete basic functions. The display accuracy is 0.3 level, with functions such as free input, manual adjustment, and adjustable output limit.&lt;BR&gt;&lt;BR&gt;The important thing is that the expert PID algorithm of Island Power is adopted, which has unique advantages in preventing system overshoot/undershoot.&lt;BR&gt;Before using the system, the self-tuning function can be activated to find the optimal PID parameters for the system, thereby simplifying on-site debugging and improving regulation quality.&lt;BR&gt;The algorithm of expert PID includes SF overshoot suppression coefficient. Reasonable selection can effectively avoid system overshoot or overshoot.&lt;BR&gt;Output limiting can be used to limit the size and opening of valves, avoiding excessive heating power design and power limitations on certain heating stages of special heating elements.&lt;BR&gt;To prevent deviation from the set range required by the process, the set value limit function can be used to avoid misoperation.&lt;BR&gt;Two sets of independent event relays can be set with 7 types of events, including: upper/lower limit absolute value, upper/lower limit deviation value, deviation value inside/outside, and over range alarm.&lt;BR&gt;DC signal input method, programmable digital range, directly displays on-site industrial values.&lt;BR&gt;The linear error of the calibrated sensor or the measurement error caused by the placement position can be compensated by setting positive and negative offsets as the display of the measured value PV.&lt;BR&gt;To avoid measurement interference on site, an anti-interference digital filtering time constant can be set.&lt;BR&gt;&lt;BR&gt;SR1/3/4 Selection Table&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=2 cellPadding=2 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;SR1/SR3, SR4 PID regulators with dual four digit display, self-tuning expert PID parameters, adjustable output limits, manual/automatic switching, 2 independent upper and lower limit alarms, key locking and other functions, front panel protection level IP66.&lt;/P&gt;
&lt;P&gt;The working voltage range is 100-240 VAC 50/60 Hz, with complete basic functions that can meet the needs of conventional PID regulation.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=103&gt;
&lt;P align=center&gt;SR1-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;DIN standard: height 48 x width 48 x depth 110mm, panel opening size: 45 x 45mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=21 width=103&gt;
&lt;P align=center&gt;SR3-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 colSpan=4&gt;
&lt;P&gt;DIN standard: height 96 x width 96 x depth 110mm, panel opening size 92 x 92mm, oversized LED display&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22 width=103&gt;SR4-&lt;/TD&gt;
&lt;TD height=22 colSpan=4&gt;DIN standard: height 96 x width 48 x depth 110mm, panel opening size 92 x 45mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=103&gt;
&lt;P align=left&gt;Input type and measurement range&lt;/P&gt;
&lt;P align=left&gt;The display range for DC input can be programmed as -1999-9999. The decimal point position can be set, and the difference range between the upper and lower limits is 10-5000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=31&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;12 types of thermocouples, 14 measurement ranges: B: 0‵1800,R: 0‵1700,S: 0‵1700,K: -199.9‵400.0 K: 0.0‵800.0 K: 0‵1200,E: 0‵700, J: 0‵600, T: -199.9‵200.0, N: 0‵1300, PLII: 0‵1300 ,Wre5-26:0‵2300,U: -199.9‵200.0, L: 0‵600&lt;/P&gt;
&lt;P&gt;Pt100 platinum resistance: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥ (Jpt100 omitted)&lt;/P&gt;
&lt;P&gt;DC millivolts: -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=31&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;DC voltage: -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V DC load impedance:&amp;lt;600K 次&lt;/P&gt;
&lt;P&gt;*DC current input: requires an external 250 次 resistor&lt;/P&gt;
&lt;P&gt;0-20mA (internal selection of 0-5V range); 4-20mA (internal selection of 1-5V range)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P&gt;Adjust output type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Normally open relay contact, time proportional period: 1-120 seconds, capacity: 240V AC 2A (resistive)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Solid state relay drive, 12 &#177; 1.5V DC/maximum 30mA, proportional period 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=3&gt;
&lt;P align=center&gt;7 types of alarm event outputs&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=28&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462&gt;2 sets of normally open relay contacts: EV1, EV2 Capacity: 240VAC 1A (resistive)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=0&gt;
&lt;TD height=22 colSpan=5&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;SR1/3/4 Terminal Wiring Diagram Outline Dimensional Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110405164604633.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 128px&quot; border=0 hspace=0 alt=&quot;SR1/3/4 series self-tuning PID regulator external dimensions&quot; src=&quot;/upload2011/201104/20110405164604633.jpg&quot; width=350 height=128&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405164611882.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 205px&quot; border=0 hspace=0 alt=&quot;SR1/3/4 series self-tuning PID regulator external dimensions&quot; src=&quot;/upload2011/201104/20110405164611882.jpg&quot; width=350 height=205&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405164621202.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 254px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of SR1/3/4 series self-tuning PID regulator&quot; src=&quot;/upload2011/201104/20110405164621202.jpg&quot; width=600 height=254&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405164634843.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 459px&quot; border=0 hspace=0 alt=&quot;SR1/3/4 series self-tuning PID regulator wiring diagram&quot; src=&quot;/upload2011/201104/20110405164634843.jpg&quot; width=600 height=459&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;SR1/3/4 series self-tuning PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR50 series 0.25 level ten segment programmable PID regulator </title>
           <link>http://www.91way.com/info_en/16067.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:41:54</pubDate>
           <comments></comments>
           <description>The SR50 series PID regulator is a patented technology product of Shimada Electric Company in Japan. It adopts advanced electronic technology design, easy operation, and powerful application functions. Especially advanced is the adoption of the &quot;no overshoot expert PID&quot; new algorithm for the first time in the world, following the control theories of dual degree, adaptive, fuzzy, etc., which achieves no overshoot, no overshoot, rapid heating and disturbance suppression, and excellent system regulation quality.&lt;BR&gt;&lt;BR&gt;High precision:+0.25% FS+1 word&lt;BR&gt;Ten programmable segments (optional)&lt;BR&gt;Three sets of alarm or event output relays&lt;BR&gt;Isolation series pole (analog remote control) input: 4-20mA DC, 1-5V DC, 0-10V DC&lt;BR&gt;Equipped with RS232, RS422, RS485 communication interfaces&lt;BR&gt;Expert PID capable of suppressing overshoot/overshoot&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=2 cellPadding=2 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=27&gt;
&lt;P&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=48&gt;
&lt;P&gt;number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=13&gt;
&lt;P&gt;Special computer design, dual four digit display, accuracy (&#177; 0.25%+1 word), sampling speed of 4 times/second,&lt;/P&gt;
&lt;P&gt;PID self-tuning, &quot;no overshoot&quot; expert PID algorithm P: 0.1-999.0% FS I: 1-8000S D: 0-3600S&lt;/P&gt;
&lt;P&gt;Ordinary limiting and special linear limiting, time scale and timer output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=27&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=48&gt;
&lt;P&gt;SR52&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 colSpan=13&gt;
&lt;P&gt;DIN height 72 x width 72 x depth 110mm opening: 68 x 68mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;
&lt;P&gt;SR53&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=13&gt;
&lt;P&gt;Standard 96 x width 96 x depth 110mm 92 x 92mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48&gt;
&lt;P&gt;SR54&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=13&gt;
&lt;P&gt;Size 96 x Width 48 x Depth 110mm 92 x 45mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=2&gt;
&lt;P align=center&gt;2. Input type and measurement range (configurable measurement value filtering and offset functions)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;P&gt;14 types of thermocouples B: 0-1800 R: 0-1700 S: 0-1700 E: 0.0-700.0&lt;/P&gt;
&lt;P&gt;J:0.0‵600.0 K:-100.0‵400.0 K:0.0‵800.0 K:0‵1200&lt;/P&gt;
&lt;P&gt;T:-199.0‵200.0 N:0‵1300 PLｊ:0‵1300 WRe5-26:0‵2300&lt;/P&gt;
&lt;P&gt;U:-199.9‵200.0 L:0.0‵600.0⊥.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;P&gt;Pt100 or JPt100 (BA2) platinum resistance standard, with 36 measurement ranges available (Fahrenheit omitted)&lt;/P&gt;
&lt;P&gt;-200‵600,-100.0‵100.0,-100.0‵300.0,-50.0‵50.0,&lt;/P&gt;
&lt;P&gt;0.00‵50.00,0.00‵99.99,0.0‵100.0,0.0‵200.0,0.0‵500.0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;Linear voltage DC (mV): 0-10, 0-20, 0-50, 0-100, 10-50, -10 to 10&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=59&gt;
&lt;P align=center&gt;Digital display range programmable&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;Linear current DC (mA): 4-20, 0-20&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 width=24&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 colSpan=11&gt;
&lt;P&gt;Linear voltage DC (V): 0-1,0-2,5,0-10,1-5, -1-1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;
&lt;P align=center&gt;3. Isolation regulation control output (methods: PID, PD, PI, P, and positional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=23&gt;
&lt;P&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;Relay contact: Proportional cycle 1-120 seconds, 240VAC 2.5A (pure resistance) 1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;Linear output current: 4-20mA DC acceptance impedance below 600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;SSR driving voltage: proportional cycle 1-120 seconds 15V &#177; 3V DC/20mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=11&gt;
&lt;P&gt;Linear output voltage: 0-10V DC below 2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P align=center&gt;4. Power supply&lt;/P&gt;
&lt;P align=center&gt;(The following are options)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=10&gt;
&lt;P&gt;100‵240V AC &#177;10% SR52/53 13 W SR54 15 W&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;10-&lt;/P&gt;
&lt;P&gt;02-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=10&gt;
&lt;P&gt;24V AC&#177;10% 50/60Hz&lt;/P&gt;
&lt;P&gt;24V DC&#177;10%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=5&gt;
&lt;P align=center&gt;5.10 segment programmable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=23&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;Programmable 10 segments&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=6&gt;
&lt;P align=center&gt;6. Event relay output alarm and 17 event configurations&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=23&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;SR52, 2-point EV1, EV2/HB; SR53/54:3 Point EV1, EV2, EV3/HB&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=7&gt;
&lt;P align=center&gt;7. Isolation cascade (analog remote control) input can set remote control input value filtering and offset&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P align=center&gt;Application: Cascade regulation, or area control composed of SR50,25 and FP21 with analog transmission&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;4-20mA DC acceptance impedance:&amp;lt;250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;1-5V DC input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;0-10V DC input impedance:&amp;gt;500k 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=8&gt;
&lt;P align=center&gt;8. Y, P-type output single-phase heater disconnection (HB)/heating circuit (HL) alarm/load current monitoring&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=23&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Monitoring: 0.1-30.0A Contact: Pure Resistance 240 VAC 1.5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=9&gt;
&lt;P&gt;9. Square root operation of voltage and current input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=23&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=23&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Used for traffic conversion&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=7 colSpan=10&gt;
&lt;P&gt;10. Isolate analog transmission output&lt;/P&gt;
&lt;P&gt;(Internally, set value SV or measured value PV can be sent)&lt;/P&gt;
&lt;P&gt;Isolation digital communication interface (can be equipped with Himanton optical isolation RS232/422/485 communication converter)&lt;/P&gt;
&lt;P&gt;Note: Only one of analog transmission and digital communication can be selected.&lt;/P&gt;
&lt;P&gt;SR52 does not provide communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=35&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;03&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Voltage 0-10mV output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;04&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Current 4-20mA load impedance: below 300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;06&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Voltage 0-10V, maximum load current:&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P&gt;RS-485&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 colSpan=3&gt;
&lt;P&gt;1200,2400,4800,9600&lt;/P&gt;
&lt;P&gt;Distance: 485, 422 1.2km&lt;/P&gt;
&lt;P&gt;232 15m Address: 00-31&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P&gt;RS-422A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P&gt;RS-232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR50 series 0.25 level ten segment programmable PID controller&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR25 series high-precision 0.1 level PID regulator </title>
           <link>http://www.91way.com/info_en/16065.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:41:37</pubDate>
           <comments></comments>
           <description>SR25 high-precision 0.1 level PID controller&lt;BR&gt;&lt;BR&gt;High precision:+0.1%, with LCD display window&lt;BR&gt;10 sets of pre-set SV settings&lt;BR&gt;11 sets of PID, 11 sets of adjustable output limiting, four sets of time event output, PID self-tuning, adjustable output with optional positive and negative effects&lt;BR&gt;Thermocouples, platinum resistors, multiple inputs for voltage and current, with selectable ranges&lt;BR&gt;DC input display range is programmable&lt;BR&gt;Two sets of simulated remote control outputs&lt;BR&gt;Convenient external switch for users&lt;BR&gt;Absolute values of upper and lower limits, deviation values, and multiple event alarm methods&lt;BR&gt;Equipped with RS232/RS422 communication interface&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=2 cellPadding=2 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P align=center&gt;technical performance&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;P align=center&gt;SR25&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=8&gt;
&lt;P&gt;Contains microprocessor, intelligent PID automatic regulator, DIN96 &#215; 96 &#215; 140mm, with slope control, can preset 10 point SV values, 10 sets of PID and 10 sets of limiting, with LCD screen display&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=44&gt;
&lt;P&gt;Input type and range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=16&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Thermocouple type: 15 types of thermocouples to choose from, temperature range -200~2300 ⊥&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Platinum resistance type (Pt100): 8 optional ranges, temperature range -200~600 ⊥&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC voltage type: 0-10; 10‵50; -10‵+10; 0‵20; 0‵50; 0-100mV linear input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC current type: Users can choose 4-20mA; 0-20mA linear input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC voltage type: Users can choose from 0 to 1; 1‵5˙ -1‵+1˙ 0‵2˙ 0‵5˙ 0-10V linear input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;controlled output&lt;/P&gt;
&lt;P align=center&gt;ㄗ1ㄘ&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Relay contact output: proportional cycle 1~200 seconds, 240V AC 2.5A/pure resistance, 1A/inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Current output: 4-20mA DC, load resistance=600 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Solid state relay (SSR) voltage output: proportional cycle 1~200 seconds/variable 15V/20mA DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=7 width=22&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=7 colSpan=7&gt;
&lt;P&gt;Voltage output: 0-10V DC: load current=2mA/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=3&gt;
&lt;P align=center&gt;controlled output&lt;/P&gt;
&lt;P align=center&gt;(2)&lt;/P&gt;
&lt;P align=center&gt;(Heating/Cooling)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Relay contact output: proportional cycle 1~200 seconds, 240V AC 2.5/pure resistance, 1A/inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Current output: 4-20mA DC, load resistance=600 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Solid state relay (SSR) voltage output: proportional period of 1-200 seconds; 15V/20mA DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Voltage output: 0-10V DC; Load current=2mA/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P align=center&gt;Signal contact output&lt;/P&gt;
&lt;P align=center&gt;(Alarm/Status)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;D01, D02 open collector electrode output; 24V DC/50mA maximum, can be connected to an external relay&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Contact output (single pole single throw), EV1-EV3/240V AC 2.5A/pure resistance, 1A/inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 colSpan=5&gt;
&lt;P&gt;Remote control input&lt;/P&gt;
&lt;P&gt;(Cascade regulation)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;P&gt;06&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10V DC; Input impedance=500k 次/minimum&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=90&gt;
&lt;P align=center&gt;no isolation&lt;/P&gt;
&lt;P align=center&gt;input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;04&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;4‵20mA DC; Receiving resistance 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;05&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;1-5V DC input impedance=500k 次/minimum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;4‵20mA DC; Receiving resistance 250 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=90&gt;
&lt;P align=center&gt;isolation&lt;/P&gt;
&lt;P align=center&gt;input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;1‵5V DC; Input impedance=500k 次/minimum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0‵10V DC; Input impedance=500k 次/minimum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=7 colSpan=6&gt;
&lt;P&gt;Simulate sending&lt;/P&gt;
&lt;P&gt;(Set PV or SV values inside the machine)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;thirteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10mV DC; Output impedance 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=90&gt;
&lt;P align=center&gt;Single output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4‵20mA DC; Load resistance=500 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10V DC; Load current=2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;twenty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10mV DC; Output impedance 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=90&gt;
&lt;P align=center&gt;dual output&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4‵20mA DC; Load resistance=500 次/maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P&gt;twenty-six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10V DC; Load current=2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=7&gt;
&lt;P align=center&gt;communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;RS-422Aㄛ Communication distance of 1.2 kilometers (10 units per link)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;RS-232Cㄛ Communication distance of 15 meters (point-to-point)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR25 series high-precision 0.1 level PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR70 series economical 0.5 grade PID regulator </title>
           <link>http://www.91way.com/info_en/16064.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:41:29</pubDate>
           <comments></comments>
           <description>The SR70 series is the latest 0.5 level economical instrument launched by Shimadzu Electric Company in Japan, which features no overshoot expert PID algorithm. It incorporates electronic technology developed in recent years in its design, and has the characteristics of easy operation, excellent adjustment quality, and powerful application functions. In the product design of this series, Island Power Company also adopted important technical suggestions from Chinese agents. It is currently the most cost-effective economic instrument introduced domestically, and will gradually replace the original SR46, SR47, SR48, and SR49 instruments.&lt;BR&gt;&lt;BR&gt;Display: Dual four digit seven segment digital display, control output, self-tuning (AT), alarm and disconnection alarm (AH, AL/HB) status indicator lights, measurement accuracy of 0.5% of full range+1 word; Display range of -10 to 110% of full scale; Display resolution of 0.1 or 1 word; Display refresh cycle of 0.5 seconds.&lt;BR&gt;&lt;BR&gt;Settings: Use four panel keys: cycle key, up key, down key, and confirm key.&lt;BR&gt;&lt;BR&gt;Intelligent input: Users can freely select eleven types of thermocouples B, R through panel keys, S, K. E, J, T, N, U, TL and eight types of platinum resistors Pt100/JPt100 and three types of millivolt 0-10mV, 10-50mV, 0-100mV DC input types; Voltage input 0-1,1-5,0-10V current input 4-20mA can be set; The input filtering time can be set from 0 to 100 seconds; Measurement value offset+20.0 or+200 numerical units; Sampling period is 0.5 seconds.&lt;BR&gt;&lt;BR&gt;Adjustment algorithm: Anti overshoot expert PID, automatic tuning or positional adjustment; Proportional band 0.1-999.9%, integration time 1-6000 seconds, differentiation time 0-3600 seconds, positional action sensitivity 1-999 numerical units; Control output reaction and positive effects can be set; The contact output of the time proportional periodic relay is fixed at 20 seconds, and the SSR output is 2 seconds; The anti overshoot suppression coefficient SF (0.01-1.00) can be set.&lt;BR&gt;&lt;BR&gt;Adjust output: Contact output SR71 240VAC 2A/1.2A (inductive), SR72, SR73, SR74 2.5A/1.5A (inductive); Linear output current 4-20mA, maximum output impedance 600 次; The linear output voltage is 0-10V, with a maximum load current of 2mA; the solid-state relay outputs 15+3V DC (when the load is 1.5K 次), with a maximum of 20mA.&lt;BR&gt;&lt;BR&gt;Alarm output: Two independent alarm relays (normally open contact 240VAC 1.5A; Users can freely set eight alarm types, including upper and lower limit absolute values/deviation values; The sensitivity of the alarm action is fixed at 0.2% of the full range.&lt;BR&gt;&lt;BR&gt;Single phase heater disconnection alarm: suitable for regulating output types of relay contacts or solid-state relays; The maximum current monitoring range is 0.1-50.0A; the CT accuracy of the current transformer is+5 (5%+1 word); Can be set to lock or real-time alarm mode.&lt;BR&gt;&lt;BR&gt;Set value offset (dual set value): can be controlled through the external SB terminal of the instrument; The offset range can be set from 1999 to 2000 numerical units.&lt;BR&gt;&lt;BR&gt;Key Lock: After completing parameter and system debugging, a software lock can be set to protect the working parameters on site.&lt;BR&gt;&lt;BR&gt;Himanton high-power solid-state relay: Industrial grade high-power AC solid-state relays with 100A, 180A, 240A, and 300A have been developed (patent number)&lt;BR&gt;94248502.5) is used in conjunction with island power P-type output instruments for zero crossing power regulation of three-phase and single-phase pure resistance loads.&lt;BR&gt;&lt;BR&gt;Linear current output type can be equipped with single-phase voltage/power regulating boards PAC15P/C, PAC35P/C (half controlled bridge) and Shimanto impedance capacitance absorption circuit MTX or MFX 55A~150A power modules for island power supply&lt;BR&gt;&lt;BR&gt;Other: Parameter storage: non-volatile EEPROM; Working environment temperature and humidity range: -10~50 ⊥&amp;lt;90% RH (no condensation); Working voltage: 100-240VAC+10% 50/60Hz; Power consumption: 10W; Protection standards: front panel dustproof and waterproof IEC standard (IP52), back terminal block IEC standard&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;Double four digit digital display, measurement accuracy of &#177; 0.5% of full range+1 word, sampling twice per second, self-tuning&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;1. External dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;SR71-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;DIN standard size height: 48 x width: 48 x depth: 110mm hole: 45 x 45mm ∴ no overshoot&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;SR72-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;DIN standard size 96 &#215; 48 &#215; 110mm 68 &#215; 68mm expert PID&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;SR73-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;DIN standard size 96 &#215; 96 &#215; 110mm 92 &#215; 92 mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;SR74-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;DIN standard size 96 &#215; 48 &#215; 110mm 92 &#215; 45 mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=2&gt;2. Input type and measurement range (anti-interference filtering constant can be set from 0 to 100 seconds for industrial field measurement values)&lt;/TD&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;
&lt;P&gt;eight&lt;/P&gt;
&lt;P&gt;free input&lt;/P&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;Thermocouples: 11 types, 22 measurement ranges (Hua Shi omitted): B: 0‵1800 R: 0‵1700S: 0‵1700 K1: -100‵400 K2: 0‵1200 E: 0‵700 J: 0‵600T: -199.9‵200.0 N: 0‵1300 U: -199.9‵200.0 L: 0‵600 ⊥. Platinum resistance: Pt100 or JPt100 standard, with 16 measurement ranges (Hua Shi omitted): -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥. Millivolt voltage: 0-10, 10-50, 0-100; Display range -1999 to 9999 can be set&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;Current: 4-20mA accepts impedance of 250 次; Display range -1999 to 9999 can be set&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;Voltage (V): 0-1,1-5,0-10; Display range -1999 to 9999 can be set&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;3. Adjust the output type (adjustment methods: PID, PD, PI, P, and positional)&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;Solid state relay SSR driving voltage output: proportional cycle fixed at 2 seconds; Level: 15V &#177; 3VDC/20mA (at 1.5K)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Y&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;Relay contact: Fixed proportional cycle of 20 seconds; 240V AC: 2.5A/(pure resistance) 1A/(inductive)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;Linear current output: 4-20mA DC, output impedance below 600 次&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;Linear voltage output: 0-10V DC, load current below 2mA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=4&gt;
&lt;P&gt;4. Option type&lt;/P&gt;
&lt;P&gt;♂ Upper and lower limit alarm relay output (optional) Note: Four alarm modes can be set&lt;/P&gt;
&lt;P&gt;♂ Single phase heater disconnection alarm (optional) Note: Single phase disconnection alarm is only applicable to Y1 or P1 output type instruments&lt;/P&gt;
&lt;P&gt;SB set value offset (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;68%&quot;&gt;
&lt;P&gt;Independently set upper and lower limit alarm relays output relay contact capacity: 240VAC 1.5A (pure resistance)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;68%&quot;&gt;Upper and lower limit alarm+wire breakage alarm (0.0~30.0A detection)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;68%&quot;&gt;Upper and lower limit alarm+wire breakage alarm (detection from 0.0 to 50.0A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;68%&quot;&gt;Upper and lower limit alarm+SB set value offset (dual set value)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR70 series economical 0.5-level PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]MR13 Three circuit 0.3 Level Programmable Nine segment PID Regulator </title>
           <link>http://www.91way.com/info_en/16061.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:41:03</pubDate>
           <comments></comments>
           <description>Japanese SHIMADEN multi loop control technology, with four rows of high brightness LED digital tubes used for independent display of three loop measurement values, loop numbers, and set values. Eleven light-emitting diodes display states such as output, tracking, remote control, execution, self-tuning, and events.&lt;BR&gt;&lt;BR&gt;Input: The panel buttons can freely select twelve types of thermocouples; Two types of platinum resistors Pt100/JPt100; Six millivolts; Six types of voltages; Two types of input with equal current. The range of DC input range can be set. The sampling period is 0.5, and the measurement accuracy is 0.3 levels (0.3 parts per thousand).&lt;BR&gt;&lt;BR&gt;Independent three loop constant value regulation and three temperature zone regulation using a shared program. Each loop has one set of fixed values or three sets of PID, three sets of output limiting, and three sets of anti overshoot coefficients. Output limiting, used to limit the maximum/minimum opening of the valve and avoid non-linear sections of the valve. Three different sets of PID parameters, anti overshoot coefficient, and heating power suitable for low/medium/high temperature zones can also be set separately. Match the temperature/resistance characteristics of special loads such as silicon carbide rods, molybdenum rods, silicon molybdenum rods, platinum heaters, etc., to protect and extend the service life of the heaters.&lt;BR&gt;&lt;BR&gt;Adjustment algorithm: Expert PID, selectable anti overshoot SF coefficient, effectively overcomes overshoot and overshoot when reaching the target set value.&lt;BR&gt;Multi temperature zone combination adjustment with three tracking methods: loop 2 and loop 3 can track the set value of loop 1 and set tracking offset, used for multi-point isothermal or differential temperature adjustment of well furnaces and group control of injection molding machinery; Or track the measurement value of circuit 1, complete the main and auxiliary, heating/cooling three output control; The external remote control tracking function allows designers to double the number of temperature controlled areas.&lt;BR&gt;&lt;BR&gt;Adjustable energy-saving servo start: The program is executed directly from the current furnace temperature measurement value, instead of waiting for the initial set value, which wastes energy.&lt;BR&gt;10 second power on delay output: effectively reduces surge current impact, protects thyristors, and facilitates transformer control.&lt;BR&gt;Three independent event relays: including absolute, deviation, and over range alarms, as well as time scale outputs for program execution, termination, and skipping.&lt;BR&gt;Analog transmission function: analog transmission of set values, measured values, and adjustment quantities, used for recording, multi zone control, or cascade adjustment.&lt;BR&gt;&lt;BR&gt;RS232/RS485 communication (1200-19200): One communication port controls three loop instruments and flexibly links with the DCS system. The Himanton XF-2000 configuration software package can be used to form a small DCS control system, achieving intelligent network management of the production process.&lt;BR&gt;Digital lock: After setting all parameters, the set parameters can be saved and digital lock protection can be set&lt;BR&gt;Supporting power unit: Himanton ultra-high power SSR and ZAC00 series frequency zero crossing controller; Single phase PAC15P/C or three-phase PAC35P/C assembled power regulator for Island Power; The intelligent single-phase PAC00, three-phase PAC03, and three circuit 3PAC00 new concept power regulators jointly developed by China and Japan can be used for ordinary loads, special loads, and transformer control (see product description for details).&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;item&lt;/P&gt;
&lt;P align=center&gt;eye&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=40&gt;
&lt;P align=center&gt;MR13-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Four rows of high brightness LED digital display, measurement accuracy of &#177; 0.3% FS &#177; 1 word of full range, sampling 2 times/second DIN standard: height 96 &#215; width 96 &#215; depth 110mm, panel opening size: 92 &#215; 92mm&lt;/P&gt;
&lt;P&gt;Power supply: 100-260VAC 12W 50/60HZ working environment temperature and humidity, -10-50 ⊥,&amp;lt;90% RH&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=2&gt;
&lt;P align=center&gt;1. Input type and&lt;/P&gt;
&lt;P align=center&gt;measurement range&lt;/P&gt;
&lt;P align=center&gt;The anti-interference filtering constant for industrial field measurement values can be set within 0-100 seconds&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=69 width=47&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=69 colSpan=6&gt;
&lt;P&gt;Thermocouples: 12 types, 14 measurement ranges (⊥) Fahrenheit: B:0‵1800 R:0‵1700 S:0‵1700 K1:-100.0‵400.0 K2:0.0‵800.0 K3:0‵1200 E:0‵700 J:0‵600 T:-199.9‵200.0 N:0‵1300 PLII:0‵1300 Wre5-26:0‵2300 U:-199.9‵200.0 L:0‵600 Fahrenheit Slightly&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=54 width=47&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=54 colSpan=6&gt;
&lt;P&gt;Two standard platinum resistors: can be set with 8 measurement ranges (⊥) Fahrenheit: -200~600~100.0~100.0~100.0~300.0~50.00~50.0~50.0~100.0~200.0 0.0~500.0 Pt100=(new) JIS -'89/DIN/IEC/ZBY (138.5 次)/JPt100 (BA2 139.1 次)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=28 width=47&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=28 colSpan=6&gt;
&lt;P&gt;DC millivolt voltage: -10~10, 0~10, 0~20, 0~50, 10~50, 0~100 millivolts Input impedance:&amp;gt;500K 次, programmable digital display range: -1999 to 9999, with any decimal point&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=47&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Current: 0-20mA, 4-20mA, programmable digital display range: -1999 to 9999, with any decimal point&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=28 width=47&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=28 colSpan=6&gt;
&lt;P&gt;Voltage: -1~1V, 0~1V, 0~2V, 0~5V, 1~5V, 0~10V Input impedance:&amp;gt;500K 次 Programmable digital display range: -1999~9999 decimal point arbitrary&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;
&lt;P&gt;2. Adjust the output&lt;/P&gt;
&lt;P&gt;type&lt;/P&gt;
&lt;P&gt;(with power limitation)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=38&gt;
&lt;P&gt;Y1-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Relay contact, proportional period 0.5-120.0 seconds, contact: 240V AC 2.5A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=38&gt;
&lt;P&gt;I1-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Current 4-20mA, 0-10mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=38&gt;
&lt;P&gt;P1-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Solid state relay drive, with a time proportional period of 0.5-120.0 seconds, 15 &#177; 3V DC&amp;lt;20mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=38&gt;
&lt;P&gt;V1-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P&gt;3. Programmable functions (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=58&gt;
&lt;P&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=58&gt;
&lt;P&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;A curve with 9 segments (steps)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=5&gt;
&lt;P&gt;4. Event output (optional)&lt;/P&gt;
&lt;P&gt;(Used for upper and lower limit alarms or time scales)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 width=27&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=26 colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=18 width=27&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=18 colSpan=3&gt;
&lt;P&gt;EV 1~EV3 3 3 sets of event outputs, contact capacity: 240VAC/1A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=6&gt;
&lt;P&gt;5. Simulate remote control and external switch input&lt;/P&gt;
&lt;P&gt;(Option: Only one option can be selected)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;04&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0-10V input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;05&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4-20mA receiving impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;06&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;1-5V input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;07&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;DI without voltage contact or OC gate input (5V/0.4mA DC)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 colSpan=7&gt;
&lt;P&gt;6. Isolate analog transmission and digital communication&lt;/P&gt;
&lt;P&gt;(Option: Only one option can be selected)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;03&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;0-10mV DC input impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;04&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;4-20mA DC load impedance:&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;06&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;0-10V DC load current:&amp;lt;1mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;RS-485&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=42&gt;
&lt;P&gt;seventeen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=272&gt;
&lt;P&gt;RS-232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;MR13 Three Loop 0.3 Level Programmable Nine Stage PID Regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR80 Series 0.25 Grade PID Regulator </title>
           <link>http://www.91way.com/info_en/16060.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:55</pubDate>
           <comments></comments>
           <description>The SR80 series regulator is a simplified design of the high-precision PID regulators SR25 and SR253 from Shimadzu Electric in Japan, and can be used as an upgraded product of the SR60 series&lt;BR&gt;&lt;BR&gt;0.25% FS accuracy, dual four bit slope, dual setting, dual output, room temperature point adjustment conversion strategy, external analog remote control input, analog transmission output, upper and lower limit alarm, disconnection alarm, and communication functions&lt;BR&gt;&lt;BR&gt;Widely used in semiconductor manufacturing, instrument measurement, sensor calibration, environmental testing equipment, petrochemical, metallurgical and other self-control fields.&lt;BR&gt;The rising/falling rate of the slope is convenient to set, and functions such as controlling slope operation/pause are convenient for on-site slope heating and slow starting of special processes.&lt;BR&gt;Pre adjustable dual setting values: corresponding to dual setting/dual output, four independent PID and adjustable output limits can be set. The second setting value can be selected internally or externally&lt;BR&gt;Second output function (optional), used for heating/cooling regulation, or main and auxiliary control of the same polarity. Has independent PID parameters and corresponding output limits.&lt;BR&gt;The external remote control setting function can also participate in adjustment, forming a cascade control. Multiple SR80 series PID regulators can be combined with programmable FP21 setpoint transmission to form a multi zone temperature control system, achieving synchronous regulation and other functions.&lt;BR&gt;&lt;BR&gt;Isolation digital communication interface (optional), optional with RS232C, RS485 interface or SR83 unique CC Link communication protocol, port address 1-99. We can also provide Himanton optical isolation intelligent 232-485 communication converter, which can be combined with XF-2000 Chinese window configuration software and upper computer to form a small distributed system.&lt;BR&gt;Three sets of independent event relays and disconnection alarms (optional), with 8 types of events that can be set, including: upper and lower limit absolute values, upper and lower limit deviation values, and deviation values inside/outside. Single phase heater disconnection and heating circuit alarm (optional): Current monitoring range: 0.0~50.0A.&lt;BR&gt;External digital input (optional): Two sets of voltage free contact DI inputs, which can define eight functions, including: self-tuning, manual, external remote control input, slope operation/stop, control offline, adjust polarity conversion, set value deviation/dual set value conversion.&lt;BR&gt;Analog transmission output (optional) type: measured value, set value, deviation value, adjustable output transmission, used for on-site data recording, multi zone temperature control or cascade adjustment.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=57&gt;
&lt;P align=center&gt;project&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=89&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P align=left&gt;The SR80 series is a 0.25 level PID controller, which is a simplified design of the high-precision SR25 PID controller with a 0.1 level. It has functions such as dual four digit display, dual output, external switch, remote control input, analog transmission output, slope operation, digital communication, upper and lower limit alarm, etc.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=57&gt;
&lt;P align=center&gt;1. Appearance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=89&gt;
&lt;P&gt;SR82-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;DIN standard: height 72 x width 72 x depth 111mm, panel opening size 68 x 68mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=89&gt;
&lt;P&gt;SR83-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=9&gt;
&lt;P&gt;DIN standard: height 96 x width 96 x depth 111mm, panel opening size 92 x 92mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=18 width=89&gt;
&lt;P&gt;SR84-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=18 colSpan=9&gt;
&lt;P&gt;DIN standard: height 96 x width 48 x depth 111mm, panel opening size 92 x 45mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=2&gt;
&lt;P&gt;2. Input type and&lt;/P&gt;
&lt;P&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Thermocouple: 14 types to choose from, -200.0~2300.0 ⊥, see input type selection table for details, input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;Platinum resistance: 16 measurement ranges are available, ranging from -200.0 to 600.0 ⊥. Please refer to the input type selection table on the flowchart for details. Three wire system&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC millivolts 0-10, 10-50, -10 to 10, 0-20, 0-50, 0-100mV Input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC current: 4-20mA, 0-20mA, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DC voltage: 0-1,1-5, -1-1,1,0-2,5,0-10V Input impedance:&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;
&lt;P&gt;3. Adjust output type 1&lt;/P&gt;
&lt;P&gt;Positive and negative effects can be set&lt;/P&gt;
&lt;P&gt;Resolution 1/8000&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=40&gt;
&lt;P&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Relay contact, time proportional cycle 1-120 seconds, contact: 240V AC 2. 5A resistive/1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=40&gt;
&lt;P&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=40&gt;
&lt;P&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Solid state relay drive, time proportional cycle 1-120 seconds, 12 &#177; 1.5V DC, maximum&amp;lt;30mA DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=40&gt;
&lt;P&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=4&gt;
&lt;P&gt;4. Adjust output type 2&lt;/P&gt;
&lt;P&gt;Resolution 1/255 (optional, SR82 does not have this option, SR83 and SR84 have this option, the alarm contact is reduced to two points)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;P&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=17 width=37&gt;
&lt;P&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=17 colSpan=6&gt;
&lt;P&gt;Relay contact, proportional cycle 1-120 seconds, contact: 240V AC 2.5A resistive/1A inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;P&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Solid state relay drive, proportional cycle 1-120 seconds, 12V &#177; 1.5VDC&amp;lt;30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=21 width=37&gt;
&lt;P&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 colSpan=6&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=5&gt;
&lt;P&gt;5. Power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;100‵240V AC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P&gt;10-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;24V AC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;P&gt;02-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;24V DC&#177;10%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=6&gt;
&lt;P&gt;6. Event output (8 alarm modes)&lt;/P&gt;
&lt;P&gt;Heater disconnection/circuit alarm for Y/P output&lt;/P&gt;
&lt;P&gt;(Optional, only for single-phase loads) SR82 only has two-point alarm contacts&lt;/P&gt;
&lt;P&gt;Only one of the external remote control input options can be selected&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;3 sets of event outputs, contact: 240V AC 1.0A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=25&gt;
&lt;P&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;3 sets of event outputs and 30A heater disconnection alarm (only Y and P output types are optional)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=15 width=25&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=15 colSpan=4&gt;
&lt;P&gt;3 sets of event outputs and 50A heater disconnection alarm (only Y and P output types are optional)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=7&gt;
&lt;P&gt;7. External remote control input type (optional)&lt;/P&gt;
&lt;P&gt;Purpose: Cascade control, externally set value, externally set feedback for participating in load regulation (external sensor, achieving constant voltage, constant current, and constant power control)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;
&lt;P&gt;fourteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;4-20mA DC input, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;
&lt;P&gt;fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;1-5V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;
&lt;P&gt;sixteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;0-10V DC input, input impedance&amp;gt;500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=8&gt;
&lt;P&gt;8. Isolation analog transmission output type (optional)&lt;/P&gt;
&lt;P&gt;Resolution 1/10000&lt;/P&gt;
&lt;P&gt;Transmission type: measured value, set value, deviation value, adjustable output quantity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10mV DCㄛ Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4‵20mA DCㄛ Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10V DCㄛ Load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=9&gt;
&lt;P&gt;9. Isolation of digital communication interface types with multiple protocols&lt;/P&gt;
&lt;P&gt;Supporting products: XF2000 configuration software, Himanton optical isolation RS232-/485 converter&lt;/P&gt;
&lt;P&gt;(Only one type of isolated analog transmission output can be selected for options SR82 and SR84)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=20&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=20&gt;
&lt;P&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213&gt;
&lt;P&gt;RS-485&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=20&gt;
&lt;P&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213&gt;
&lt;P&gt;RS-232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23 width=20&gt;
&lt;P&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=23 width=213&gt;
&lt;P&gt;CC-LINK (only available on SR83, and can choose one of the isolated analog transmission output options)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=9&gt;
&lt;P&gt;10. External DI input switch without voltage contact input (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=20&gt;
&lt;P&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213&gt;
&lt;P&gt;None.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=20&gt;
&lt;P&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=213&gt;
&lt;P&gt;Two point input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR80 series 0.25 level PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]FP93 Programmable 40 Segment 0.3 Level PID Regulator </title>
           <link>http://www.91way.com/info_en/16059.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:46</pubDate>
           <comments></comments>
           <description>FP93 Programmable 40 Segment 0.3L PID Regulator&lt;BR&gt;&lt;BR&gt;FP93 has 4 sets of curves, each with 10 segments, and can also have a maximum of 40 segments per set, with a maximum duration of 99 minutes and 59 seconds or 99 hours and 59 minutes per segment. The program can perform 9999 large cycles. When there is a power outage on site, the program can continue running from the breakpoint, and the parameters during operation can also be modified. Compared with the Island Power FP21, there is only a difference in accuracy and LCD window.&lt;BR&gt;&lt;BR&gt;The non overshoot expert PID algorithm with 6 sets of island power patents also includes 6 independent output limiting parameters and 6 independent anti overshoot suppression coefficients, which are set in a matching manner in the curve to achieve the best matching of adjustment parameters, output power, and anti overshoot, under overshoot, etc. in different temperature zones. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Advanced zone PID technology enables PID parameters to automatically switch according to changes in three zones: low temperature zone, medium temperature zone, and high temperature zone. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;If the system design power is too high, output limiting function can be used. It can also limit the maximum/minimum opening of the valve, reduce the surge current when powered on, match the temperature/resistance characteristics of special loads such as silicon carbon rods, silicon molybdenum rods, and platinum heaters, and solve the contradiction between vacuum degree and heating power matching in vacuum furnaces. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The three sets of independent event relays gifted can be set with 16 types of events and 9 types of alarms: absolute values of upper and lower limits, deviation values of upper and lower limits, internal/external alarm modes for deviation values, and can further set the return difference and handling measures for alarms. Other events include program execution, skip steps, end time stamps, maintenance, and ensuring the platform. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The above events can also be extended for output through four sets of OC gates (optional) DO1-DO4. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The gifted TS1 and TS2 sets of time scale outputs can be programmed with curves, serving as a time sequence controller for auxiliary control such as opening and closing furnace doors. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The four sets of external switch DI inputs provided as a gift allow for easy selection of program execution/reset, hold, skip, constant value/program, simplifying complex keyboard operations. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;In high-quality heat treatment processes, it is necessary to ensure precise processing time when entering the insulation zone (platform). The allowable deviation when the temperature reaches the platform can be set, and the program will be automatically delayed until the deviation caused by system lag or overshoot is overcome. After the temperature reaches the platform, the program in the insulation area will start timing. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Energy saving servo start, the first stage of the program jumps to the actual furnace temperature point and starts executing, instead of waiting for the program to start at the set value, effectively saving energy and time. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Isolated digital communication interface (optional), RS232C or RS485 (port address 1-255), multiple communication protocols A small distributed system consisting of a supporting Himanton optical isolation intelligent RS232/485 communication converter and XF-2000 Chinese window configuration software (Note: More than 10 years of successful application experience)&lt;BR&gt;&lt;BR&gt;Analog transmission output (optional): optional measurement value setting value, deviation value, and adjustment output transmission, used for on-site data recording. It can also be combined with multiple three loop MR13 or analog remote control instruments to form a programmable temperature control system with multiple temperature zones. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;FP93 regulator &quot;P&quot; output is combined with Beijing Himanton's ultra-high power SSR, zero crossing unit, and power regulation unit. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The FP93 regulator &quot;I&quot; (4-20mA) output can be used in conjunction with single-phase or three-phase voltage/power regulation trigger boards and Himanton power modules for island power.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=127&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;The most advanced programmable PID controller (with an accuracy of 0.3% FS), where zone PID is an advanced regulation technology, and the large and bright display panel represents the latest trend. It has powerful functions, superior performance, rich interfaces, and is known as the &quot;small FP21&quot; of Island Power&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=127&gt;
&lt;P align=center&gt;FP93-&lt;/P&gt;
&lt;P align=center&gt;Height 96 x width 96 x depth 110mm,&lt;/P&gt;
&lt;P align=center&gt;Hole size:&lt;/P&gt;
&lt;P align=center&gt;92&#215;92mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Important statement: At the suggestion of Beijing Himanton, a gift function worth approximately 420 yuan is also included in the basic configuration price as a thank you to Chinese users for their long-term use of Island Electric products!&lt;/P&gt;
&lt;P&gt;1. Three independent event relay (capacity 240V AC 1A/resistive): can be set with absolute and deviation value alarms, time stamps, program operation, jumping, ending time stamps, holding, and ensuring platform and other 16 events&lt;/P&gt;
&lt;P&gt;2. Simplify key operations for 4 sets of external switches: program execution/reset, hold, skip, select curve and constant value adjustment, etc&lt;/P&gt;
&lt;P&gt;3. Two sets of programmable TS1 and TS2 time scales, equivalent to a time sequence controller, are used to complete auxiliary control such as opening and closing furnace doors&lt;/P&gt;
&lt;P&gt;In addition, the DO1-DO4 four sets of OC gate expansion outputs for the options also include relay interfaces provided with the options&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=127&gt;
&lt;P align=center&gt;Input type and measurement range&lt;/P&gt;
&lt;P align=center&gt;The display range of DC input type can be set to -1999-9999&lt;/P&gt;
&lt;P align=center&gt;The decimal point position can be set&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=356&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=66&gt;
&lt;P&gt;10 types of thermocouples, 14 measurement ranges: B: 0‵1800,R: 0‵1700,S: 0‵1700,K: -199.9‵400.0 K: 0.0‵800.0 K: 0‵1200,E: 0‵700, J: 0‵600, T: -199.9‵200.0, N: 0‵1300, PLII: 0‵1300 ,Wre5-26:0‵2300,U: -199.9‵200.0, L: 0‵600 ⊥&lt;/P&gt;
&lt;P&gt;Platinum resistance Pt100: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥ (JPt100 omitted)&lt;/P&gt;
&lt;P&gt;DC millivolts: -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV DC&lt;/P&gt;
&lt;P&gt;DC voltage: -1~1,0~1,0~2,0~5,1~5,0~10V DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=35&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;DC current: 0-20, 4-20mA, input impedance: 250 次 Note: 1 external 250 次 precision resistor is randomly attached&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P&gt;Adjust output type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Relay contact, time ratio cycle: 1-120 seconds, capacity: 240V AC 2.5A/resistive 1A/inductive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Solid state relay drive, 12V &#177; 1.5V DC/maximum 30mA, time proportional period 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=43&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=3&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;100‵240V AC&#177;10% ,50/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;24V AC/DC&#177;10%, 50/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P&gt;(Optional) DO1-DO4 four group OC gate expansion&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;Capacity: External 12-24VDC 20mA, Beijing Himanton provides XK-4 relay interface as a gift&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=5&gt;
&lt;P&gt;(Optional) Analog transmission: measurement value, set value, adjustment output value, used for recorders. It can also be combined with multiple three loop MR13 or instruments with analog remote control to form a programmable temperature control system with multiple temperature zones.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=28&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=28&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10mV DC, Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=28&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4‵20mA DC, Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=28&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10V DC, Load current&amp;lt;2 mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=6&gt;
&lt;P&gt;(Optional) Digital communication interface: Internal independent DC/DC power supply, extremely high anti common mode interference suppression capability&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=26&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=26&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280&gt;
&lt;P&gt;RS-485 address: 1-255. One line can connect up to 32 devices&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=26&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=280&gt;
&lt;P&gt;RS-232C only connects to one unit&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;FP93 Programmable 40 Segment 0.3L PID Regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR93/94 Series 0.3 Grade PID Regulator </title>
           <link>http://www.91way.com/info_en/16058.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:38</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;The SR90 series is a 0.3 level PID intelligent regulator with dual four position display, dual output, analog transmission output, digital communication, disconnection alarm, upper and lower limit alarm and other functions. The front panel protection level is IP66.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;SR93-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DIN standard: height 96 x width 96 x depth 110mm, panel opening size 92 x 92mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=51&gt;
&lt;P align=center&gt;SR94-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DIN standard: height 96 x width 48 x depth 110mm, panel opening size 92 x 45mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=51&gt;
&lt;P&gt;Input type and measurement range&lt;/P&gt;
&lt;P&gt;Display range of DC input type -1999-9999 decimal point position can be set&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=123 width=17&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=123 colSpan=7&gt;
&lt;P&gt;Thermocouple: B:0‵1800,R:0‵1700,S:0‵1700,K1:100.0‵400.0,K2:0.0‵800.0,K3:-200‵1200,E:0‵700,J:0‵600,T:-199.9‵200.0,N:0‵1300,PLII:0‵1300,Wre5-26:0‵2300,U:-199.9‵200.0,L:0‵600 ⊥&lt;/P&gt;
&lt;P&gt;Pt100 platinum resistance: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥ (JPt100 omitted)&lt;/P&gt;
&lt;P&gt;DC millivolts: -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=37 width=17&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=37 colSpan=7&gt;
&lt;P&gt;DC current: 0-20mA, 4-20mA, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=16 width=17&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=16 colSpan=7&gt;
&lt;P&gt;DC voltage: -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V DC load impedance:&amp;lt;600K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P&gt;Adjust output (1) type&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Relay contact, time proportional period: 1-120 seconds, contact capacity: 240V AC 2A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Solid state relay drive, 12 &#177; 1.5V DC/maximum 30mA, time proportional period 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=4&gt;
&lt;P&gt;Adjust output (2) type&lt;/P&gt;
&lt;P&gt;Positive and negative effects can be set&lt;/P&gt;
&lt;P&gt;(Optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Relay contact, time proportional cycle 1-120 seconds, contact capacity: 240V AC 2A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Solid state relay drive, 12V &#177; 1.5V DC/maximum 30mA, proportional period 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=5&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;100‵240V AC&#177;10% ,50/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=33&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;24V AC/DC&#177;10%, 50/60Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=6&gt;
&lt;P&gt;Event output (optional)&lt;/P&gt;
&lt;P&gt;(Heater disconnection alarm is only available when adjusting the output (1) to Y-shaped/P-type output)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=12&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=12&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Event output: EV1, EV2 contact capacity: 240V AC 1A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=12&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Event output: EV1 and 30A heater disconnection alarm (contact capacity: 240V AC 1.5A/resistive)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=12&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Event output: EV1 and 50A heater disconnection alarm (contact capacity: 240V AC 1.5A/resistive)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=10 colSpan=3&gt;
&lt;P&gt;option&lt;/P&gt;
&lt;P&gt;(Select only one option)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;00&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=4&gt;
&lt;P align=center&gt;Simulate sending&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;thirty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;0‵10mV DC, Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;4‵20mA DC, Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;0‵10V DC, Load current&amp;lt;2 mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Dual Setpoint (SB)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;08&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;1 point (range: -1999~5000), no voltage contact or OC gate input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=4&gt;
&lt;P align=center&gt;Simulate sending and dual set values (SB)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;thirty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;0‵10mV DC, Output impedance: 10 次+SB (1 point)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;forty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;4‵20mA DC, Load impedance&amp;lt;300 次+SB (1 point)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;sixty-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;0‵10V DC, Load current&amp;lt;2 mA+SB (1 point)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P align=center&gt;Digital communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;05&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;RS485 address: 1-255&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;07&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=438&gt;
&lt;P&gt;RS232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR93/94 series 0.3-level PID regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR92 Series 0.3 Grade PID Regulator </title>
           <link>http://www.91way.com/info_en/16057.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:29</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;SR92 is a 0.3 level PID intelligent regulator with dual four position display, dual output, analog transmission output, digital communication, disconnection alarm, upper and lower limit alarm and other functions. The front panel protection level is IP66.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=61&gt;
&lt;P align=center&gt;SR92-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;DIN standard: height 72 x width 72 x depth 110mm, panel opening size 68 x 68mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=61&gt;
&lt;P&gt;Input type and measurement range&lt;/P&gt;
&lt;P&gt;(Display range of DC input type -1999-9999 and decimal point position can be set)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=14&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;Thermocouple: B:0‵1800,R:0‵1700,S:0‵1700,K1:100.0‵400.0,K2:0.0‵800.0,K3:-200‵1200,E:0‵700,J:0‵600,T:-199.9‵200.0,N:0‵1300,PLII:0‵1300,Wre5-26:0‵2300,U:-199.9‵200.0,L:0‵600 ⊥&lt;/P&gt;
&lt;P&gt;Pt100 platinum resistance: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥ (JPt100 omitted)&lt;/P&gt;
&lt;P&gt;DC millivolt -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=14&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;DC current: 0-20mA, 4-20mA, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=14&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;DC voltage: -1~1, 0~1, 0~2, 0~5, 1~5, 0~10V Input impedance: 500K 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=2&gt;
&lt;P&gt;Adjust output (1) type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Relay contact, proportional cycle 1-120 seconds, contact capacity: 240V AC 2A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Solid state relay drive, proportional cycle 1-120 seconds, 12 &#177; 1.5V DC/maximum 30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=6&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 colSpan=3&gt;
&lt;P&gt;Adjust output (2) type&lt;/P&gt;
&lt;P&gt;Positive and negative effects can be set&lt;/P&gt;
&lt;P&gt;(Optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Relay contact, proportional cycle 1-120 seconds, contact: 240V AC 2A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Solid state relay drive, proportional cycle 1-120 seconds, 12V &#177; 1.5V DC/maximum 30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;100‵240V&amp;nbsp; AC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=34&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;24V AC/DC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=5&gt;
&lt;P&gt;Event output (optional)&lt;/P&gt;
&lt;P&gt;(When the heater is disconnected, only the output (1) can be adjusted. It is optional when it is a Y-shaped/P-type output.)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;Event output: EV1, EV2 Contact: 240V AC 1A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;Event output: EV1 and 30A heater disconnection alarm (contact: 1.5A/resistive)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;Event output: EV1 and 50A heater disconnection alarm (contact: 1.5A/resistive)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=6&gt;
&lt;P&gt;Isolation analog transmission (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10mV DC, Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;4‵20mA DC, Load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;0‵10V DC, Load current&amp;lt;2 mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=7&gt;
&lt;P&gt;Digital communication interface or dual set value (SB)&lt;/P&gt;
&lt;P&gt;(Choose one)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396&gt;
&lt;P&gt;RS485 address: 1-255&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396&gt;
&lt;P&gt;RS232C&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=22&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396&gt;
&lt;P&gt;1 point (range: -1999~5000), no voltage contact or OC gate input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;SR92 Series 0.3L PID Regulator&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SR91 Series 0.3 Grade PID Regulator </title>
           <link>http://www.91way.com/info_en/16056.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:20</pubDate>
           <comments></comments>
           <description>Introduction to SR90 Series 0.3L PID Regulator&lt;BR&gt;High performance, low price, reliable design, not easy to compare! &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Dimensions: SR91 (48 &#215; 48mm) SR92 (72 &#215; 72mm) SR93 (96 &#215; 96mm) SR94 (96 &#215; 48mm)&lt;BR&gt;&lt;BR&gt;The SR90 series is the latest technological product of Shimada Electric Company in 2002, which highly summarizes the application experience of the SR60 to SR70 series and highlights the design concept of high performance and high reliability. It has free input, display accuracy of 0.3 level, manual function, adjustable output limit, dual set values, dual adjustable output, analog transmission output, digital communication function, and the front panel meets the IP66 protection standard. We have adopted Island Power's non overshoot expert PID algorithm, with two independent PID parameters and complete functions, while the performance price ratio exceeds Island Power's SR73A/SR74A series. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The SR91 series 0.3-level PID regulator makes the operator more eye-catching with high brightness and large character display, with an accuracy of &#177; 0.3% FS+1 character and a sampling/display cycle of 4 times per second. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Before using the system, the self-tuning function can be activated to find the optimal PID parameters for the system, thereby simplifying on-site debugging and improving regulation quality. &amp;nbsp;&lt;BR&gt;The algorithm of expert PID includes SF overshoot suppression coefficient. Reasonable selection can effectively avoid system overshoot or overshoot. &amp;nbsp;&lt;BR&gt;A 0-100 second power on slow start can be set to reduce the surge current of the load, protect the device, and extend the service life of the heating element to a certain extent. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Output limiting can be used to limit the size and opening of valves, avoiding excessive heating power design and power limitations on certain heating stages of special heating elements. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The second output function (optional) can be used for heating/cooling regulation or main/auxiliary heating control. It is also possible to adjust the dead zone DB of the interaction interval between the dual adjustment nodes, achieving the goal of improving control accuracy and saving energy. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;The daytime control of the greenhouse and the preheating or insulation purposes of the heating system require dual setting SB (optional), which can be selected with one contact point. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;To prevent deviation from the set range required by the process, the set value limit function can be used to avoid misoperation. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Two sets of independent event relays can be set with 9 types of events, including: upper and lower limit absolute values, upper and lower limit deviation values, and deviation value internal/external alarm modes. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Isolation digital communication interface (optional), optional RS232C, RS485 interface, port address 1-255. We can also provide Himanton optical isolation intelligent RS232/485 communication converter, which can be combined with XF-2000 Chinese window configuration software and upper computer to form a small distributed system. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Analog transmission (optional): measurement value, set value, deviation value, adjustable output transmission, used for on-site data recording, multi zone temperature control or cascade adjustment. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Single phase heater disconnection and heating circuit alarm (optional): Current monitoring range: 0.0~30.0A and 0.0~50.0A&lt;BR&gt;&lt;BR&gt;The linear error of the calibrated sensor or the measurement error caused by the placement position can be compensated by setting positive and negative offsets as the display of the measured value PV. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;To avoid measurement interference on site, an anti-interference digital filtering time constant can be set.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;Number&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;SR91 is a 0.3 level PID intelligent regulator with dual four digit display, dual output, analog transmission output, digital communication, disconnection alarm, upper and lower limit alarm, dual set values and other functions. The front panel has a protection level of IP66.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=55&gt;
&lt;P align=center&gt;SR91-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;P&gt;DIN standard: height 48 x width 48 x depth 110mm, panel opening size: 45 x 45mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=55&gt;
&lt;P&gt;Input type and measurement range&lt;/P&gt;
&lt;P&gt;Display range of DC input type -1999-&lt;/P&gt;
&lt;P&gt;9999, decimal point position can be set&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;eight&lt;/P&gt;
&lt;P align=center&gt;free input&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;Thermocouple: B:0‵1800,R:0‵1700,S:0‵1700,K1:100.0‵400.0,K2:0.0‵800.0,K3:-200‵1200,E:0‵700,J:0‵600,T:-199.9‵200.0,N:0‵1300,PLII:0‵1300,Wre5-26:0‵2300,U:-199.9‵200.0,L:0‵600 ⊥&lt;/P&gt;
&lt;P&gt;Pt100 platinum resistance: -200~600, -100.0~100.0, -50.0~50.0, 0.0~200.0 ⊥ (JPt100 omitted)&lt;/P&gt;
&lt;P&gt;DC millivolt -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;DC current: 0-20mA, 4-20mA DC, input impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=13 colSpan=2&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=13 colSpan=5&gt;
&lt;P&gt;DC voltage: -1~1, 0~1, 0~2, 0~5, 1~5, 0~10 V DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=3&gt;
&lt;P&gt;Adjust output (1)&lt;/P&gt;
&lt;P&gt;type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=16&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Relay contact, proportional cycle 1-120 seconds, contact capacity: 240V AC 2.5A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Solid state relay drive, 12 &#177; 1.5V DC/maximum 30mA, proportional period 1-120 seconds,&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=16&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2Ma&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;100‵240V&amp;nbsp; AC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=53&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;P&gt;24V AC/DC&#177;10%(50/60Hz)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=5&gt;
&lt;P&gt;Event output (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=8&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=8&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Event output: EV1, EV2 contact capacity: 240V AC 1A resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=12 colSpan=2&gt;
&lt;P&gt;option&lt;/P&gt;
&lt;P&gt;(Choose one)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 colSpan=4&gt;
&lt;P align=center&gt;Adjust output (2)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;Relay contact, proportional cycle 1-120 seconds, contact: 240V AC 2.5A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;Current 4-20mA DC, load impedance&amp;lt;600 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;Solid state relay drive, proportional cycle 1-120 seconds, 12V &#177; 1.5V DC/maximum 30mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;Voltage 0-10V DC, load current&amp;lt;2mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=4&gt;
&lt;P align=center&gt;Heater disconnection alarm (optional only when adjusting output (1) to Y/P output)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;30A heater disconnection alarm, contact capacity: 240V AC 1.5A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;50A heater disconnection alarm, contact capacity: 240V AC 1.5A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 colSpan=4&gt;
&lt;P align=center&gt;Simulate sending&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;0-10mV DC output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;4-20mA DC load impedance&amp;lt;300 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;0-10V DC load current&amp;lt;2 mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Digital communication interface&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;RS485 address: 1-255&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4&gt;
&lt;P align=center&gt;Dual Setpoint (SB)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=367&gt;
&lt;P&gt;1 point (set range: -1999~5000), no voltage contact or OC gate input&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]SRS13/14 Series 0.25 Level Programmable PID Regulator </title>
           <link>http://www.91way.com/info_en/16055.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:40:11</pubDate>
           <comments></comments>
           <description>SRS10 series, 0.25 level precision 32 step programmable PID controller&lt;BR&gt;On the basis of summarizing years of successful experience in the Chinese market and absorbing suggestions from customers,&lt;BR&gt;Shimadzu Corporation launches SRS10 series with ultra-high cost-effectiveness&lt;BR&gt;&lt;BR&gt;A more stylish appearance! Ultra thin body, with a thickness of only 60mm&lt;BR&gt;Input/output isolation, sampling period of 0.25 seconds&lt;BR&gt;3 SV settings&lt;BR&gt;Multiple inputs and range of measurement&lt;BR&gt;0.25 level accuracy, 32 steps programmable (1-4 curves, 32-8 steps)! &amp;nbsp;&lt;BR&gt;RS-485 communication interface, Modbus/Shimaden protocol (optional)&lt;BR&gt;Rich functional options&lt;BR&gt;Non overshoot expert PID algorithm; 3 independent PID parameters; 4 independent set values; 3-channel event output; 4-channel switch input; Simulate transmission.&lt;BR&gt;32 step (8 steps x 4 steps) programmable function: can set the maximum 32 step rise/fall/insulation curve that can meet the majority of heat treatment processes&lt;BR&gt;Original MODBUS communication interface: It can achieve real-time digital communication between up to 31 instruments, and the master meter can send data to multiple slave meters in real time, making multi zone temperature control more accurate.&lt;BR&gt;New platinum resistor with a temperature range of -100.0 to 350.0 ⊥; Power on slow start; Manually adjust the output.&lt;BR&gt;Communication functions can be achieved using configuration software such as Kunlun Tongtai and Kingview.&lt;BR&gt;&lt;BR&gt;Selection Table of 0.25 Level Programmable PID Regulators for SHIMADEN SRS13/14 Series in Japan&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=72 colSpan=2&gt;
&lt;P align=center&gt;Model Code&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=560 colSpan=13&gt;
&lt;P&gt;Super bright dual four digit LED display, no overshoot expert PID algorithm, three independent PID parameters, AT self-tuning, manual/automatic disturbance free switching control, adjustable output limit, 3 event outputs, 3 independent set values, 3 switch inputs, 32 step programmable, analog transmission output, digital communication and other functions. Sampling period: 250ms. Front panel protection level IP66.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72 colSpan=2&gt;
&lt;P align=center&gt;SRS13-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=560 colSpan=13&gt;
&lt;P&gt;Dimensions: Height 96 x Width 96 x Depth 68mm, Panel Hole Size: 92 x 92mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=11 width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=72 colSpan=2&gt;
&lt;P align=center&gt;SRS14-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=560 colSpan=13&gt;
&lt;P&gt;Dimensions: Height 48 x Width 96 x Depth 68mm, Panel Hole Size: 45 x 92mm&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=72 colSpan=2&gt;
&lt;P&gt;input type&lt;BR&gt;measurement range&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=30&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=398 colSpan=11&gt;
&lt;P&gt;Thermocouples: B, R, S, K, E, J, T, N, PLII, WRe5-26, U, L&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=5 width=132&gt;
&lt;P&gt;Range see SRS13/14 Input Type and Measurement Range Comparison Table&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=398 colSpan=11&gt;
&lt;P&gt;Platinum resistance: Pt100/JPt100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=398 colSpan=11&gt;
&lt;P&gt;Voltage (mV): -10~10, 0~10, 0~20, 0~50, 10~50, 0~100mV DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=30&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=398 colSpan=11&gt;
&lt;P&gt;Current (mA): 0-20mA, 4-20mA DC, Input Impedance: 250 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=398 colSpan=11&gt;
&lt;P&gt;Voltage (V): -1~1,0~1,0~2,0~5,1~5,0~10V DC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=101 colSpan=3&gt;
&lt;P&gt;Adjust output 1&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;Y&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=498 colSpan=11&gt;
&lt;P&gt;Relay contact, capacity: 240V AC 2A/resistive, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=498 colSpan=11&gt;
&lt;P&gt;Solid state relay (SSR) drive, 12 &#177; 1.5V DC/30mA maximum, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;I&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=498 colSpan=11&gt;
&lt;P&gt;Current 4-20mA DC, load impedance: 600 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=32&gt;
&lt;P align=center&gt;V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=498 colSpan=11&gt;
&lt;P&gt;Voltage 0-10V DC, load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=134 colSpan=4&gt;
&lt;P&gt;Adjust output 2 (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;N-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;Y-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Relay contact, capacity: 240V AC 2A/resistive, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=6 width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;I-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Current 4-20mA DC, load impedance: 600 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;P-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Solid state relay (SSR) drive, 12V &#177; 1.5V DC/30mA maximum, proportional period: 1-120 seconds&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;V-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Voltage 0-10V DC, load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=31&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=3&gt;
&lt;P&gt;Additional event output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;E-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Additional event output 1 point (EV3)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=31&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102 colSpan=3&gt;
&lt;P&gt;Additional external input control signal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;D-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=462 colSpan=10&gt;
&lt;P&gt;Additional external control input 1 point (DI4)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=170 colSpan=5&gt;
&lt;P&gt;power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;90-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=426 colSpan=9&gt;
&lt;P&gt;100‵240V AC&#177;10%ㄛ50/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;08-&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=426 colSpan=9&gt;
&lt;P&gt;24V AC/DC&#177;10%ㄛ50/60Hz&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=206 colSpan=6&gt;
&lt;P&gt;Program functions (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;P align=center&gt;N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396 colSpan=8&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=30&gt;
&lt;P align=center&gt;P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=396 colSpan=8&gt;
&lt;P&gt;Up to 4 segments, a total of 32 steps in the program&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=235 colSpan=7&gt;
&lt;P&gt;Event output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=372 colSpan=7&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=372 colSpan=7&gt;
&lt;P&gt;Event output 2-point (EV1, EV2) contact capacity: 240V AC 1A/resistive&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=259 colSpan=8&gt;
&lt;P&gt;Simulated sending (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336 colSpan=6&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336 colSpan=6&gt;
&lt;P&gt;0‵10mV DC?? Output impedance: 10 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336 colSpan=6&gt;
&lt;P&gt;4‵20mA DC?? Load impedance: 300 次 maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=336 colSpan=6&gt;
&lt;P&gt;0‵10V DC??? Load current: 2mA maximum&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=295 colSpan=9&gt;
&lt;P&gt;CT input (optional) note: CT is sold separately&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=5&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=3&gt;
&lt;P&gt;CT input 2 points&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=216 colSpan=2&gt;
&lt;P&gt;Optional when adjusting output 1 or 2 to Y or P&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=331 colSpan=10&gt;
&lt;P&gt;External input control signal DI (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=264 colSpan=4&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=36&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=264 colSpan=4&gt;
&lt;P&gt;External control input 3 points (DI1, DI2, DI3)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=367 colSpan=11&gt;
&lt;P&gt;Communication (optional)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=240 colSpan=3&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=240 colSpan=3&gt;
&lt;P&gt;RS485 (Shimaden Standard Protocol,&lt;BR&gt;MODBUS protocol)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=391 colSpan=12&gt;
&lt;P&gt;Special Notes&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;0&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=216 colSpan=2&gt;
&lt;P&gt;nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=24&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=216 colSpan=2&gt;
&lt;P&gt;Yes (please consult in advance)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[industrial control equipment]GD-3S photoelectric lateral correction instrument </title>
           <link>http://www.91way.com/info_en/4789.html</link>
           <author></author>
           <guid></guid>
           <category>industrial control equipment</category>
           <pubDate>2026-6-18 15:39:54</pubDate>
           <comments></comments>
           <description>The GD-3S photoelectric lateral correction instrument uses infrared photoelectric sensors to detect the left and right deviation of the substrate. After being amplified by the controller, the low-speed synchronous motor drives the screw to perform lateral correction on the substrate. GD-3 can directly replace the original GD-2, and GD-3 has stronger anti-interference ability and faster response time. The controller adopts an embedded structure. Hole size: 232 &#177; 0.5mm &#215; 150 &#177; 0.5mm, installation space depth not less than 230mm, chassis external dimensions: 250mm &#215; 160mm &#215; 180mm.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=2 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Working voltage (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Motor power (W)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Motor speed (rpm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Correction accuracy (mm)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Correction speed (mm/s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Thrust (N)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;Travel distance (mm)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;GD-3-90&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;&#177;0.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;GD-3-130A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;&#177;0.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;twenty-four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;GD-3-130B&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;&#177;0.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;GD-3-130C&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;two hundred and twenty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;&#177;0.3&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;four thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=71&gt;
&lt;P align=center&gt;one hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GD-3S photoelectric lateral correction instrument&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>