       <item>
           <title>[DC circuit breaker]CM3DC series DC circuit breaker </title>
           <link>http://www.91way.com/info_en/26198.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:54</pubDate>
           <comments></comments>
           <description>The CM3DC series DC circuit breaker has four housing frames of 100A, 250A, 400A, and 630A, with currents ranging from 10A to 630A.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center x:str=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR height=21&gt;
&lt;TD height=21 width=176 colSpan=2&gt;Shell level rated current I&lt;SUB&gt;nm&lt;/SUB&gt;(A)&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;one hundred&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;four hundred&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;model&lt;/TD&gt;
&lt;TD colSpan=2&gt;CM3DC-100&lt;/TD&gt;
&lt;TD colSpan=2&gt;CM3DC-250&lt;/TD&gt;
&lt;TD colSpan=2&gt;CM3DC-400&lt;/TD&gt;
&lt;TD colSpan=2&gt;CM3DC-630&lt;/TD&gt;
&lt;TD colSpan=2&gt;CM3DC-800&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Number of series poles&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=32&gt;
&lt;TD height=32 colSpan=2&gt;Rated current I&lt;SUB&gt;n&lt;/SUB&gt;(A)&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;10/16/20/25/32/&lt;BR&gt;40/50/63/80/100&lt;/TD&gt;
&lt;TD width=176 colSpan=2&gt;16/20/25/32/40/50/63/&lt;BR&gt;80/100/125/140/160/&lt;BR&gt;180/200/225/250&lt;/TD&gt;
&lt;TD colSpan=2&gt;225/250/315/350/400&lt;/TD&gt;
&lt;TD colSpan=2&gt;400/500/630&lt;/TD&gt;
&lt;TD colSpan=2&gt;630/700/800&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=21&gt;
&lt;TD height=21 colSpan=2&gt;Rated insulation voltage U&lt;SUB&gt;i&lt;/SUB&gt;(V)&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=21&gt;
&lt;TD height=21 colSpan=2&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;(V)&lt;/TD&gt;
&lt;TD colSpan=2&gt;eight thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;eight thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;eight thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;eight thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;eight thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=30&gt;
&lt;TD height=30 colSpan=2&gt;Rated working voltage U&lt;SUB&gt;e&lt;/SUB&gt;(V)&lt;/TD&gt;
&lt;TD width=88&gt;DC500&lt;BR&gt;DC750&lt;/TD&gt;
&lt;TD width=88&gt;DC750&lt;BR&gt;DC1000&lt;/TD&gt;
&lt;TD width=88&gt;DC500&lt;BR&gt;DC750&lt;/TD&gt;
&lt;TD width=88&gt;DC750&lt;BR&gt;DC1000&lt;/TD&gt;
&lt;TD width=88&gt;DC500&lt;BR&gt;DC750&lt;/TD&gt;
&lt;TD width=88&gt;DC750&lt;BR&gt;DC1000&lt;/TD&gt;
&lt;TD width=88&gt;DC500&lt;BR&gt;DC750&lt;/TD&gt;
&lt;TD width=88&gt;DC750&lt;BR&gt;DC1000&lt;/TD&gt;
&lt;TD width=88&gt;DC500&lt;BR&gt;DC750&lt;/TD&gt;
&lt;TD width=88&gt;DC750&lt;BR&gt;DC1000&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Flying arc distance (mm)&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Û50&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Û50&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Û100&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Û100&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡Û100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 rowSpan=3 width=88&gt;Rated ultimate short-circuit breaking capacity I&lt;SUB&gt;cu&lt;/SUB&gt;(kA)&lt;/TD&gt;
&lt;TD&gt;DC500V&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;sixty-five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC750V&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC1000V&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 rowSpan=3 width=88&gt;Rated operating short-circuit breaking capacity I&lt;SUB&gt;cs&lt;/SUB&gt;(kA)&lt;/TD&gt;
&lt;TD&gt;DC500V&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC750V&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DC1000V&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;50%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=21&gt;
&lt;TD height=21 colSpan=2&gt;Rated short-circuit connection capacity I&lt;SUB&gt;cm&lt;/SUB&gt;(kA)&lt;/TD&gt;
&lt;TD colSpan=2&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;100%I&lt;SUB&gt;cu&lt;/SUB&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Usage category&lt;/TD&gt;
&lt;TD colSpan=2&gt;A&lt;/TD&gt;
&lt;TD colSpan=2&gt;A&lt;/TD&gt;
&lt;TD colSpan=2&gt;A&lt;/TD&gt;
&lt;TD colSpan=2&gt;A&lt;/TD&gt;
&lt;TD colSpan=2&gt;A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;Electrical lifespan (times)&lt;SUP&gt;1)&lt;/SUP&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;Mechanical lifespan (times)&lt;SUP&gt;1)&lt;/SUP&gt;&lt;/TD&gt;
&lt;TD&gt;maintenance-free&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;three thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;There is maintenance&lt;/TD&gt;
&lt;TD colSpan=2&gt;twenty thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;twenty thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten thousand&lt;/TD&gt;
&lt;TD colSpan=2&gt;six thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 rowSpan=3 width=88&gt;Overall dimensions&lt;BR&gt;(©L)&lt;/TD&gt;
&lt;TD&gt;Width (3 poles/4 poles)&lt;/TD&gt;
&lt;TD colSpan=2&gt;75/100&lt;/TD&gt;
&lt;TD colSpan=2&gt;107/142&lt;/TD&gt;
&lt;TD colSpan=2&gt;150/198&lt;/TD&gt;
&lt;TD colSpan=2&gt;182/240&lt;/TD&gt;
&lt;TD colSpan=2&gt;210/280&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;long&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and thirty&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and sixty-five&lt;/TD&gt;
&lt;TD colSpan=2&gt;two hundred and fifty-seven&lt;/TD&gt;
&lt;TD colSpan=2&gt;two hundred and seventy&lt;/TD&gt;
&lt;TD colSpan=2&gt;two hundred and eighty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;tall&lt;/TD&gt;
&lt;TD colSpan=2&gt;sixty&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and three&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and six point five&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and ten&lt;/TD&gt;
&lt;TD colSpan=2&gt;one hundred and fifteen point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=12&gt;Note:&lt;BR&gt;1) According to GB14048.1, the term &quot;lifespan&quot; refers to the probability of the number of operational cycles completed by an electrical appliance before repairing or replacing a component.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CM3DC series DC circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]SH6C series quick closing automatic switch </title>
           <link>http://www.91way.com/info_en/25371.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:45</pubDate>
           <comments></comments>
           <description>SH8C-1000V, 2500A quick closing automatic switch&lt;BR&gt;&lt;BR&gt;Purpose and conditions of use&lt;BR&gt;Suitable for rated voltage DC1000V and below, rated current 2500A and below. When there is a fault in the power system, the main bypass protection is for overcurrent in the AC/DC hybrid transmission grid. When the DC transmission operates on a single pole ground, the ground pole current flows into the AC system through the neutral point of the transformer, causing varying degrees of impact on the AC transmission system. This switch can effectively suppress the DC current at the neutral point of the transformer, ensuring the safe and stable operation of the transformer and AC system.&lt;BR&gt;&lt;BR&gt;Normal usage conditions&lt;BR&gt;Altitude not exceeding 2000m&lt;BR&gt;The ambient air temperature is between -5 ¡æ and+40 ¡æ.&lt;BR&gt;Atmospheric conditions: The average maximum relative humidity of the wettest month is not greater than 90%, and the average minimum temperature of that month is 25 ¡æ.&lt;BR&gt;The pollution level of the switch is PD3 in a medium without explosive hazards and without gases and dust (including conductive dust) that can corrode metals and damage insulation.&lt;BR&gt;The inclination of the corresponding horizontal plane during installation shall not exceed 5 ¡æ.&lt;BR&gt;&lt;BR&gt;SH6C series fast closing automatic switch technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;60%&quot;&gt;eye&lt;/TD&gt;
&lt;TD width=&quot;40%&quot; colSpan=2&gt;model&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;SH8C-2500/1000&lt;/TD&gt;
&lt;TD&gt;SH8C-1600/1000&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD colSpan=2&gt;one thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated current (A)&lt;/TD&gt;
&lt;TD&gt;two thousand and five hundred&lt;/TD&gt;
&lt;TD&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Main circuit withstand voltage (V)&lt;/TD&gt;
&lt;TD colSpan=2&gt;four thousand and two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Current connection capability (KA. 300ms)&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;thirty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2&gt;ten thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Main contact opening distance (mm)&lt;/TD&gt;
&lt;TD colSpan=2&gt;6~8&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Main contact pressure (N)&lt;/TD&gt;
&lt;TD colSpan=2&gt;180&#177;20N&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Main contact closing time (ms)&lt;/TD&gt;
&lt;TD colSpan=2&gt;&amp;lt;20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Auxiliary contact point&lt;/TD&gt;
&lt;TD colSpan=2&gt;4a4b&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]QDS28-S DC air circuit breaker </title>
           <link>http://www.91way.com/info_en/24243.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;QDS28-S DC air circuit breaker&lt;BR&gt;&lt;BR&gt;1. QDS DC air circuit breaker&lt;BR&gt;2. ¡õ - Design Number&lt;BR&gt;3. ¡õ - Rated working current&lt;BR&gt;4. ¡õ - Operation method (S-manual operation)&lt;BR&gt;5. X-Product installation of protective box shell&lt;BR&gt;6. ¡õ - Rated working voltage (KV)&lt;BR&gt;&lt;BR&gt;Structural characteristics of QDS28-S DC air circuit breaker:&lt;BR&gt;1. Base and bracket: made of thermosetting engineering plastic compression, serving as mechanical support and electrical insulation, with excellent insulation performance;&lt;BR&gt;2. Operating mechanism: composed of a rotating shaft, energy storage spring, transmission components, and mechanical lock buckle, the circuit is manually closed and locked through an operating handle. When overcurrent occurs, the transmission mechanism can be automatically disconnected through a trip, and under normal circumstances, manual quick disconnection can be achieved through the operating handle;&lt;BR&gt;3. Dynamic and static contacts: Silver alloy contacts using DC contactors have characteristics such as resistance to welding and wear. The static contacts are connected to the arc blowing coil, while the dynamic contacts are connected to the lead out terminal through soft connections;&lt;BR&gt;4. Arc extinguishing cover: composed of a maze type ceramic arc extinguishing chamber, large and small arc ignition angles, and an arc resistant plastic shell, it has excellent arc extinguishing effect and short arc spraying distance when the circuit breaker is disconnected;&lt;BR&gt;5. Magnetic blowing coil: wound with silver plated flat copper wire, with a movable iron core at the center, which not only generates electromagnetic force for overcurrent tripping, but also provides a blowing magnetic field for the arc extinguishing chamber through a magnetic plate;&lt;BR&gt;6. Tripping current adjustment mechanism: composed of components such as a crank, tension spring, indicator, locking screw, etc. The tripping current value can be adjusted by adjusting the screw, with clear scale indication and can be locked to prevent loosening;&lt;BR&gt;7. Auxiliary contact: It has a pair of normally open and normally closed pure silver contacts, which can slide laterally at the moment of connection to ensure good contact;&lt;BR&gt;8. Operating handle: With insulation protection function, it can be separated from the circuit breaker body and is a specialized operating tool.&lt;BR&gt;&lt;BR&gt;Normal working and installation conditions:&lt;BR&gt;1. The altitude shall not exceed 2500 meters;&lt;BR&gt;2. The highest temperature of the surrounding air is+50 ¡æ, and the lowest is -40 ¡æ;&lt;BR&gt;3. The maximum relative humidity of the surrounding air shall not exceed 90%;&lt;BR&gt;4. Vibration intensity: For sinusoidal vibrations in any direction of longitudinal, transverse, or vertical, the amplitude shall not exceed A, and the value of A shall be determined by the following formula:&lt;BR&gt;A=25/f, frequency f=1-10Hz&lt;BR&gt;A=250/f2, frequency f=10-50Hz&lt;BR&gt;5. In environments without explosion hazards, corrosive gases, and conductive dust.&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212183506997.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 575px&quot; border=0 hspace=0 alt=&quot;QDS28-S DC air circuit breaker appearance and installation dimensions&quot; src=&quot;/upload2013/201312/20131212183506997.jpg&quot; width=680 height=575&gt;&lt;/A&gt;&lt;BR&gt;QDS28-S DC air circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]QDS28-160DS DC air circuit breaker </title>
           <link>http://www.91way.com/info_en/24227.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131212101501902.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 667px; HEIGHT: 500px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of QDS28-160DS DC air circuit breaker&quot; src=&quot;/upload2013/201312/20131212101501902.jpg&quot; width=667 height=500&gt;&lt;/A&gt;&lt;BR&gt;QDS28-160DS DC air circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]CW3DC DC universal circuit breaker </title>
           <link>http://www.91way.com/info_en/23080.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:20</pubDate>
           <comments></comments>
           <description>The CW3DC DC universal circuit breaker (hereinafter referred to as the circuit breaker) maintains the same external dimensions and installation dimensions as the CW3. It is mainly installed in low-voltage DC distribution circuits to connect and disconnect the main circuit, and can also serve as an isolation device. Its symbol is &quot;&quot;.&lt;BR&gt;Rated current 800A~2500A;&lt;BR&gt;Rated working voltage DC1000V and below;&lt;BR&gt;Having a three pole string and a four pole string;&lt;BR&gt;Drawer style and fixed style;&lt;BR&gt;The product meets the following standards:&lt;BR&gt;IEC60947-1 and GB14048.1 General Principles for Low Voltage Switchgear and Control Equipment&lt;BR&gt;IEC60947-2 and GB14048.2 Low voltage switchgear and control equipment Circuit breakers&lt;BR&gt;The product has obtained the national mandatory product certification CCC mark&lt;BR&gt;&lt;BR&gt;2. Normal working conditions and installation conditions&lt;BR&gt;The ambient air temperature is between -5 ¡æ and+40 ¡æ, and the average value over 24 hours does not exceed+35 ¡æ;&lt;BR&gt;The altitude of the installation site shall not exceed 2000m;&lt;BR&gt;The relative humidity of the air at the installation site shall not exceed 50% at a maximum temperature of+40 ¡æ; At lower temperatures, there can be higher relative humidity, with the monthly average lowest temperature of the wettest month not exceeding+25 ¡æ, and the monthly average maximum relative humidity of that month not exceeding 90%, taking into account condensation on the surface of the product due to temperature changes;&lt;BR&gt;The pollution level is level 3;&lt;BR&gt;The installation category of the main circuit is IV, and the installation category of the other auxiliary circuits and control circuits is III;&lt;BR&gt;&lt;BR&gt;The CW3DC DC universal circuit breaker should be installed according to the instructions in the user manual. Its vertical inclination does not exceed 5 &#176;.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=292 colSpan=5&gt;Model number&lt;/TD&gt;
&lt;TD width=528 colSpan=6&gt;CW3DC-2500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Shell level rated current I&lt;SUB&gt;nm&lt;/SUB&gt;(A)&lt;/TD&gt;
&lt;TD colSpan=6&gt;two thousand and five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated current I&lt;SUB&gt;n&lt;/SUB&gt;(A)&lt;/TD&gt;
&lt;TD colSpan=6&gt;800, 1000, 1250, 1600, 2000, 2500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated working voltage U&lt;SUB&gt;e&lt;/SUB&gt;(V)&lt;/TD&gt;
&lt;TD colSpan=3&gt;DC 500/750&lt;/TD&gt;
&lt;TD colSpan=3&gt;DC 750/1000&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated insulation voltage U&lt;SUB&gt;i&lt;/SUB&gt;(V)&lt;/TD&gt;
&lt;TD colSpan=6&gt;one thousand two hundred and fifty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;(kV)&lt;/TD&gt;
&lt;TD colSpan=6&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Number of series poles&lt;/TD&gt;
&lt;TD colSpan=3&gt;Three pole string&lt;/TD&gt;
&lt;TD colSpan=3&gt;Quadrupole string&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated ultimate short-circuit breaking capacity Icu (kA)&lt;/TD&gt;
&lt;TD colSpan=6&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated operating short-circuit breaking capacity Ics (kA)&lt;/TD&gt;
&lt;TD colSpan=6&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated short-circuit making capacity Icm (kA)&lt;/TD&gt;
&lt;TD colSpan=6&gt;100%Icu&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Rated short-time withstand current Icw (kA)/1s&lt;/TD&gt;
&lt;TD colSpan=6&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Usage category&lt;/TD&gt;
&lt;TD colSpan=6&gt;B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Opening time (without additional delay) (ms)&lt;/TD&gt;
&lt;TD colSpan=6&gt;30~40&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Closing time (ms)&lt;/TD&gt;
&lt;TD colSpan=6&gt;Maximum 70&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=6&gt;seven thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=194 colSpan=3&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2&gt;maintenance-free&lt;/TD&gt;
&lt;TD colSpan=6&gt;twelve thousand and five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;There is maintenance&lt;/TD&gt;
&lt;TD colSpan=6&gt;twenty-five thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=7 width=64&gt;Overall dimensions&lt;BR&gt;(mm)&lt;/TD&gt;
&lt;TD colSpan=4&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;W&lt;/TD&gt;
&lt;TD colSpan=2&gt;H&lt;/TD&gt;
&lt;TD colSpan=2&gt;L&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4&gt;drawer-type&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;Horizontal connection (rear)&lt;/TD&gt;
&lt;TD&gt;Three pole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and forty-seven&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and thirty-eight&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quadrupole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and forty-two&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and thirty-eight&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2&gt;Vertical connection (rear)&lt;/TD&gt;
&lt;TD&gt;Three pole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and forty-seven&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and thirty-eight&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quadrupole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and forty-two&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and thirty-eight&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;fixed type&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=2&gt;Horizontal connection (rear)&lt;/TD&gt;
&lt;TD&gt;Three pole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and sixty-two&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;
&lt;TD colSpan=2&gt;two hundred and ninety&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quadrupole string&lt;/TD&gt;
&lt;TD colSpan=2&gt;four hundred and fifty-seven&lt;/TD&gt;
&lt;TD colSpan=2&gt;three hundred and ninety-five&lt;/TD&gt;
&lt;TD colSpan=2&gt;two hundred and ninety&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CW3DC DC universal circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GM5-63 Small DC Circuit Breaker </title>
           <link>http://www.91way.com/info_en/18252.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:12</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GM5-63 small DC circuit breaker adopts a special arc extinguishing and current limiting system, which can quickly break the fault current of the DC distribution system, greatly improving the level difference coordination. This series has excellent performance and can avoid the occurrence of accidents such as over level tripping between the measurement and protection screen and the distribution screen in the DC system of power engineering. The differential matching characteristics of this series of products are the best among similar products at home and abroad.&lt;BR&gt;&lt;BR&gt;The GM5-63 series small DC circuit breaker complies with GB10963.2-2003 &quot;Overcurrent Protection Circuit Breakers for Household and Similar Places Part 2: Circuit Breakers for AC and DC&quot;, and is suitable for single pole rated DC voltage not exceeding 220V, two pole rated DC voltage not exceeding 440V, rated current 1-63A, and rated insulation voltage 500V lines. It is used for overcurrent protection of buildings and similar places' line facilities, and can also be used for infrequent on-off operations. This circuit breaker has the characteristics of small size, high breaking capacity, short arcing distance, fast closing, and easy installation. This product is suitable for non professionals to use and does not require maintenance. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216143600300.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 653px; HEIGHT: 370px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GM5-63 small DC circuit breaker&quot; src=&quot;/upload2012/201202/20120216143600300.jpg&quot; width=653 height=370&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GM5B-32 Three stage protection small DC circuit breaker </title>
           <link>http://www.91way.com/info_en/18251.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:48:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GM5B-32 three-stage protection small DC circuit breaker applies advanced electronic delay control technology, fault current sampling components, and a series of proprietary technologies from our factory, which make the short delay action performance independent of the power supply voltage. At rated current, the electronic control circuit has almost no voltage, achieving the goal of small volume, precise delay protection, high product service life and reliability for power protection system requirements, and comprehensively improving the guarantee ability of DC power supply.&lt;BR&gt;&lt;BR&gt;The GM5B-32 three-stage protection small DC circuit breaker is the core project independently developed by our factory as a new product. It is a major technological breakthrough in the field of DC distribution protection. In addition to its outstanding advantages such as precise and reliable delay protection function, it also has the smallest volume compared to the previous year (GMB32 width is 72mm). While effectively reducing the space occupied by distribution appliances, it will also greatly improve the protection level of the DC power system.&lt;BR&gt;&lt;BR&gt;The successful development of GM5B-32 three-stage protection small DC circuit breaker not only meets the demand for high-precision &quot;three-stage&quot; protection DC circuit breakers in domestic and foreign markets, but also comprehensively improves the independent innovation ability of national enterprises in this industry, effectively promotes industry technological progress, and further consolidates and expands our factory's leading advantages in the field of power protection technology at home and abroad.&lt;BR&gt;&lt;BR&gt;The GM5B-32 series plastic shell three-stage protection DC circuit breaker complies with GB14048.2 &quot;Low Voltage Switchgear and Control Equipment - Low Voltage Circuit Breakers&quot; and is suitable for use in power engineering with a nominal DC voltage of 110V or 220V, a maximum working voltage not exceeding 250V, and a rated current of 16A to 32A. It is used for overcurrent protection of line facilities and electrical equipment, and can also be used for infrequent on-off operations. This circuit breaker has the characteristics of small size and short delay action, which is independent of the power supply voltage and only depends on the magnitude of the short-circuit current. This product is suitable for use by non professionals. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216143335557.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 653px; HEIGHT: 322px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GM5B-32 three-stage protection small DC circuit breaker&quot; src=&quot;/upload2012/201202/20120216143335557.jpg&quot; width=653 height=322&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GM5FB Series Selective Protection Molded Case DC Circuit Breaker </title>
           <link>http://www.91way.com/info_en/18249.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GM5FB series selective protection molded case DC circuit breaker is one of the new circuit breakers developed by our factory using internationally leading design and manufacturing technology, with independent intellectual property rights, and based on our factory's higher than international and national standards. Its rated working voltage is DC250V, suitable for infrequent switching and starting in circuits with DC rated current of 63-800A. Circuit breakers have overload and short-circuit short delay protection functions, which can protect distribution lines and power equipment from damage. Its short-circuit short delay has the inverse time characteristic of a fuse, with good current limiting ability and delayed action function. If applied in the protection of important loads in the power system, it can prevent fault current from spreading and provide fully selective protection. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;meet the standard&lt;BR&gt;IEC60947-1 GB14048.1 General Provisions&lt;BR&gt;IEC60947-2 GB14048.2 Low Voltage Circuit Breakers&lt;BR&gt;IEC60947-4 GB14048.4 Contactors and Motor Starters&lt;BR&gt;IEC60947-5-1 GB14048.5 Electromechanical Control Circuit Electrical Appliances&lt;BR&gt;&lt;BR&gt;Technical parameters of GM5FB series selective protection molded case DC circuit breaker&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216141849342.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 771px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GM5FB series selective protection molded case DC circuit breaker&quot; src=&quot;/upload2012/201202/20120216141849342.jpg&quot; width=650 height=771&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GW3B Universal DC Circuit Breaker </title>
           <link>http://www.91way.com/info_en/18248.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;GW3B universal DC circuit breaker is suitable for DC systems with rated voltage of DC250V~DC1000V and rated current of 1000-2000A. It is used to distribute electrical energy and protect lines and power equipment from overload, undervoltage, short circuit and other hazards.&lt;BR&gt;&lt;BR&gt;This circuit breaker has selective protection function, achieving graded coordination protection and backup protection between circuit breaker levels to reduce the scope of accidents in the power grid. Therefore, it is particularly suitable for protection systems of large capacity DC current power supplies.&lt;BR&gt;&lt;BR&gt;The drawer type circuit breaker has an insertable structure, which improves the efficiency of use. Both the main and secondary circuits adopt an insertable structure, omitting the necessary isolating switches for fixed circuits, achieving dual use for one machine. At the same time, it brings great convenience to operation and maintenance, enhances safety, reliability, and flexibility in emergency situations. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;meet the standard&lt;BR&gt;IEC60947-1¡¡GB14048.1&lt;BR&gt;IEC60947-2¡¡GB14048.2&amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical Specifications&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216141649639.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 613px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GW3B universal DC circuit breaker&quot; src=&quot;/upload2012/201202/20120216141649639.jpg&quot; width=650 height=613&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]TIB1Z-63 Small DC Circuit Breaker </title>
           <link>http://www.91way.com/info_en/17506.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:39</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Compliant with standards: GB10963.2, IEC60898-2&lt;BR&gt;Environmental temperature: -5 ¡æ to 40 ¡æ&lt;BR&gt;Wiring capability: Suitable for wires of 25mm2 and below&lt;BR&gt;Mechanical lifespan: 20000&lt;BR&gt;Breaking capacity: 10KA&lt;BR&gt;Release characteristic: C&lt;BR&gt;Rated voltage: 125V (1p), 250V (2p) DC&lt;BR&gt;Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;TIB1Z-63 Small DC Circuit Breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DM8G series magnetic field circuit breaker </title>
           <link>http://www.91way.com/info_en/15668.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:30</pubDate>
           <comments></comments>
           <description>DM8G series magnetic field circuit breaker&lt;BR&gt;&lt;BR&gt;Technical parameters of magnetic field circuit breaker without normally closed secondary contacts&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=137 colSpan=2&gt;
&lt;DIV align=center&gt;model&lt;BR&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;200/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;400/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;630/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;800/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;1000/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;1600/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;2500/800&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage Ue (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Strong excitation voltage (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Main circuit withstand voltage * * (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;four thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated current * (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Breaking current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand eight hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand and eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Building pressure capacity (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;2500 (single fracture ¡Ý 1400)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;7500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Electrical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;DIV align=center&gt;&amp;gt;600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&amp;gt;400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Contact opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;17&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Contact pressure (N)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;180&#177;20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;power control&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;close&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;DC220V&amp;lt;5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;trip&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;DC220V&amp;lt;2A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Closed (ms)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Operating Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;
&lt;DIV align=center&gt;Electric motor closing&lt;/DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;synchronicity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Split excitation (ms)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Operating Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü50&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;synchronicity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Technical parameters of magnetic field circuit breaker with normally closed secondary contacts&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=145 colSpan=2&gt;
&lt;DIV align=center&gt;model&lt;BR&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;200/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;400/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=93&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;630/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;800/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=86&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;1000/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;1600/800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;DIV align=center&gt;DM8G-&lt;BR&gt;2500/800&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage Ue (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Strong excitation voltage (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Main circuit withstand voltage * * (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;four thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated current of normally open main contact * (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand and five hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated current of normally closed auxiliary contact * (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Breaking current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;four hundred&lt;/TD&gt;
&lt;TD&gt;eight hundred&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand and six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Building pressure capacity (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;2500 (single fracture ¡Ý 1400)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;7500&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Electrical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;DIV align=center&gt;&amp;gt;600&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;&amp;gt;400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Normally open main contact opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;17&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Normally closed auxiliary contact opening distance (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;&amp;gt;14&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Normally open main contact pressure (N)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;180&#177;20&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Normally closed auxiliary contact pressure (N)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;49&#177;5.9&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;power control&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;close&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;
&lt;DIV align=center&gt;DC220V&amp;lt;5A&lt;/DIV&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;trip&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;DC220V&amp;lt;2A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Closed (ms)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Operating Time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;Electric motor closing&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;synchronicity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Split excitation (ms)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Operating Time&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü50&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;synchronicity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=7&gt;
&lt;DIV align=center&gt;¡Ü1&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DM8G series magnetic field circuit breaker&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GSB1Z series small DC circuit breaker </title>
           <link>http://www.91way.com/info_en/5127.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:22</pubDate>
           <comments></comments>
           <description>GSB1Z series small DC circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]QDS5 type fast circuit breaker </title>
           <link>http://www.91way.com/info_en/2305.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:14</pubDate>
           <comments></comments>
           <description>QDS5 type fast circuit breaker&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]QDS8 series DC fast circuit breaker </title>
           <link>http://www.91way.com/info_en/2187.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:47:05</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=59 colSpan=4&gt;The QDS8 series DC fast circuit breaker is used as a main circuit short circuit and overload protection in subway and light rail vehicles, industrial and mining electric locomotives, and railway traction locomotives. It can also be used as a protective switch for silicon rectification devices and DC motors in industrial fields such as steel rolling and mining, and as a graded protection circuit breaker for small DC feeding devices&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Rated voltage Ue&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;1500V&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;30000 times&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Rated current In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;1250A&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;Operating voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;DC110¡¢50V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Maximum operating voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;1800V&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;Number of auxiliary contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;6 normally open, 6 normally closed&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Maximum breaking capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;35KA(T=15ms)&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;Auxiliary contact capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;AC220V 10A,DC110V 1A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Breaking overvoltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;1.5-2.1Ue&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;Overall dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;420*165*485&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Inherent action time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;2-3ms&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;installation dimensions&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;4-¦Õ9£¬130*145mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Current setting range&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;0.6*1.25; 0.9*1.8;&lt;BR&gt;1.25*2.7KA&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;weight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=148&gt;&amp;lt;37kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=78&gt;
&lt;DIV align=left&gt;Electrical lifespan&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=140&gt;1000 times&lt;/TD&gt;
&lt;TD width=51&gt;
&lt;DIV align=left&gt;&lt;/DIV&gt;
&lt;DIV align=left&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;QDS8 series DC fast circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DS16 DC Fast Circuit Breaker </title>
           <link>http://www.91way.com/info_en/2186.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:57</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Rated voltage (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;1500V&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Control power supply (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;DC110&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;four thousand&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Dimensions (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;761*380*860&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Maximum operating voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;1800V&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Installation size (mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;4-¦Õ11£¬320*160&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Rated limit breaking (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;75(T=15ms)&lt;BR&gt;110(T=15ms)&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Number of auxiliary contacts&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;5NC+5NO&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;twenty thousand&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Weight (Kg)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;one hundred and ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Electrical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;five hundred&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Inherent action time (ms)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;four&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Current setting range (KA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;2-5£¬4-10&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;Auxiliary contact capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=87&gt;AC220V&amp;nbsp;&amp;nbsp;&amp;nbsp; 10A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=99&gt;
&lt;DIV align=left&gt;Current setting range&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;2-8£¬4-15 DC110V 1A&lt;/TD&gt;
&lt;TD width=126&gt;
&lt;DIV align=left&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DS16 DC fast circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DM8B series magnetic field circuit breaker </title>
           <link>http://www.91way.com/info_en/600.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:49</pubDate>
           <comments></comments>
           <description>The DM8B magnetic field circuit breaker is suitable for use as a demagnetization protection circuit breaker in the main excitation circuit of generators with a rated voltage of DC800V and below and a rated current of 6300A and below, when combined with nonlinear resistors. Alternatively, it can be combined with appropriate constant resistance to form a demagnetization combination device for generators, suitable for excitation circuits of 600000 kilowatts and below with rated voltage of DC 500V and below, and rated current of 6300A and below, for demagnetization protection. In addition, it can also be used to disconnect excitation circuits under no-load or rated load, or to carry and analyze other DC circuits.&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 352px; HEIGHT: 174px&quot; border=0 hspace=0 alt=&quot;Model Description of DM8B Series Magnetic Field Circuit Breaker&quot; src=&quot;/uploadfiles/200610/2006102712517266.gif&quot; width=350 height=173&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DS19 series DC fast circuit breaker </title>
           <link>http://www.91way.com/info_en/599.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:40</pubDate>
           <comments></comments>
           <description>DS19 DC fast circuit breaker (hereinafter referred to as circuit breaker) is mainly used for short-circuit and overload protection of rectifier units, DC motors, and feeder lines in circuits with rated voltage of 1600V DC and below and rated current of 4000A and below. It is particularly suitable as a power supply protection switch for subway and light rail traction substations, and can also be used as a protection switch for rectifier devices and DC motors in important industrial fields such as steel rolling and mining.&lt;BR&gt;&lt;BR&gt;DS19 series DC fast circuit breaker models and their meanings:&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 350px; HEIGHT: 173px&quot; border=0 hspace=0 alt=&quot;DS19 series DC fast circuit breaker model description&quot; src=&quot;/uploadfiles/200610/20061027124856676.gif&quot; width=350 height=173&gt;&lt;BR&gt;Main technical parameters of DS19 series DC fast circuit breaker:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 86px&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center height=86&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=52 width=&quot;10%&quot; align=middle&gt;Rated voltage (Ue)&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Maximum operating voltage&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;Rated ultimate breaking capacity&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; align=middle&gt;Inherent working hours&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;Electrical lifespan&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;Number of auxiliary contacts&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;Overall dimensions&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;Operating voltage&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;1600V&lt;/TD&gt;
&lt;TD align=middle&gt;1800V&lt;/TD&gt;
&lt;TD align=middle&gt;75KA(T=15ms)&lt;/TD&gt;
&lt;TD align=middle&gt;6ms&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;BR&gt;two hundred&lt;/TD&gt;
&lt;TD align=middle&gt;5NC+5ND&lt;/TD&gt;
&lt;TD align=middle&gt;500, 400, 100, 50&lt;/TD&gt;
&lt;TD align=middle&gt;DC220¡¢110¡¢50V;&lt;BR&gt;AC220V&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse; HEIGHT: 86px&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center height=86&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=52 width=&quot;10%&quot; align=middle&gt;Rated current (In)&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Rated insulation voltage&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Breaking overvoltage&lt;/TD&gt;
&lt;TD width=&quot;25%&quot; align=middle&gt;Current setting range&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;mechanical life&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Auxiliary contact capacity&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;installation dimensions&lt;/TD&gt;
&lt;TD width=&quot;6%&quot; align=middle&gt;weight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;2500A/4000A&lt;/TD&gt;
&lt;TD align=middle&gt;4000V&lt;/TD&gt;
&lt;TD align=middle&gt;(1.5¡«2.0)Ue&lt;/TD&gt;
&lt;TD align=middle&gt;(1.25¡«2.7)KA; (2¡«5)KA&lt;BR&gt;(2¡«8)KA; (4¡«10)KA&lt;BR&gt;/(2¡«5)KA; (4¡«10)KA&lt;BR&gt;(2¡«8)KA; (4¡«15)KA&lt;BR&gt;&lt;/TD&gt;
&lt;TD align=middle&gt;twenty thousand&lt;/TD&gt;
&lt;TD align=middle&gt;AC220V 10A;&lt;BR&gt;DC110V 1A&lt;/TD&gt;
&lt;TD align=middle&gt;4£­¦µ11,&lt;BR&gt;320*160(mm)&lt;/TD&gt;
&lt;TD align=middle&gt;86kg&lt;BR&gt;98kg&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DS19 series DC fast circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]QDS7 series electric locomotive DC fast circuit breaker </title>
           <link>http://www.91way.com/info_en/598.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:32</pubDate>
           <comments></comments>
           <description>The QDS7 series DC fast circuit breaker for electric locomotives is suitable for short-circuit and overload protection in DC circuits with a rated current of 2000A and below in coal mines, mines, and industrial and mining electric locomotives.&lt;BR&gt;&lt;BR&gt;Model and its meaning:&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;Rated voltage UeV&lt;/TD&gt;
&lt;TD width=&quot;8%&quot; align=middle&gt;Maximum operating voltage V&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;Set current range A&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;Breaking ability (KA)&lt;BR&gt;six&lt;BR&gt;(di/dt=3&#215;10 A/S)&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Overvoltage during disconnection/test voltage&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;Full break time (ms)&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD width=&quot;16%&quot; align=middle&gt;Rated breaking capacity (times)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=20 align=middle&gt;one thousand and five hundred&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and eight hundred&lt;/TD&gt;
&lt;TD align=middle&gt;£¨0.8-2)Ie&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü3&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü30&lt;/TD&gt;
&lt;TD align=middle&gt;twenty thousand&lt;/TD&gt;
&lt;TD align=middle&gt;2Ie£¬180&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DM8 series magnetic field circuit breaker </title>
           <link>http://www.91way.com/info_en/597.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:24</pubDate>
           <comments></comments>
           <description>The main specifications of DM8 series magnetic field circuit breakers are:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;DM8-200¡¢400¡¢630¡¢800¡¢1000¡¢1600¡¢2500/500-£¨1/0¡¢1/1¡¢2/0¡¢2/2£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;DM8-200¡¢400¡¢630¡¢800¡¢1000¡¢1600¡¢2500/800-£¨1/0¡¢1/1¡¢2/0¡¢2/2£©&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=5&gt;Main technical parameters:&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;DM4 series magnetic field circuit breaker&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;DM8 series magnetic field circuit breaker&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;eight hundred&lt;/TD&gt;
&lt;TD align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Strong excitation voltage (V)&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD width=&quot;26%&quot; align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Main circuit withstand voltage (V)&lt;/TD&gt;
&lt;TD colSpan=4 align=middle&gt;four thousand and two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Rated current (A)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;1000, 1600, 2500, 4000&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;200, 400, 630, 800, 1000, 1600, 2500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Breaking current (A)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;3000, 4800, 7500, 12000&lt;/TD&gt;
&lt;TD align=middle&gt;400, 800, 1260, 1600, 2000, 3200, 5000&lt;/TD&gt;
&lt;TD align=middle&gt;600, 1200, 1890, 2400, 3000, 4800, 7500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;
&lt;P&gt;Building pressure capacity&lt;BR&gt;(Loop inductance 1H)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;gt;1500&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P&gt;&amp;gt;2500 (single fracture&amp;gt;1400)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;four hundred&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;seven thousand and five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Closing operation action time (ms)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;110&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Electric motor closing&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Excitation operation action time (ms)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;135&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;50&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DM8 series magnetic field circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DM4 series magnetic field circuit breaker </title>
           <link>http://www.91way.com/info_en/596.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The main specifications of DM4 series magnetic field circuit breakers are:&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;52%&quot;&gt;DM4-1000¡¢1600¡¢2500¡¢4000/500-(1¡¢2)&lt;/TD&gt;
&lt;TD width=&quot;48%&quot;&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;DM4-1000¡¢1600¡¢2500¡¢4000/800-(1¡¢2)&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;DM4 series magnetic field circuit breaker&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;DM8 series magnetic field circuit breaker&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Rated voltage (V)&lt;/TD&gt;
&lt;TD width=&quot;18%&quot; align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;13%&quot; align=middle&gt;eight hundred&lt;/TD&gt;
&lt;TD align=middle&gt;five hundred&lt;/TD&gt;
&lt;TD width=&quot;24%&quot; align=middle&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;19%&quot; align=middle&gt;Strong excitation voltage (V)&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;
&lt;TD width=&quot;26%&quot; align=middle&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD align=middle&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Main circuit withstand voltage (V)&lt;/TD&gt;
&lt;TD colSpan=4 align=middle&gt;four thousand and two hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Rated current (A)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;1000, 1600, 2500, 4000&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;200, 400, 630, 800, 1000, 1600, 2500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Breaking current (A)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;3000, 4800, 7500, 12000&lt;/TD&gt;
&lt;TD align=middle&gt;400, 800, 1260, 1600, 2000, 3200, 5000&lt;/TD&gt;
&lt;TD align=middle&gt;600, 1200, 1890, 2400, 3000, 4800, 7500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;
&lt;P&gt;Building pressure capacity&lt;BR&gt;(Loop inductance 1H)&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;gt;1500&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;
&lt;P&gt;&amp;gt;2500 (single fracture&amp;gt;1400)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;four hundred&lt;/TD&gt;
&lt;TD align=middle&gt;six hundred&lt;/TD&gt;
&lt;TD align=middle&gt;four hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;five thousand&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;seven thousand and five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Closing operation action time (ms)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;110&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;Electric motor closing&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD align=middle&gt;Excitation operation action time (ms)&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;135&lt;/TD&gt;
&lt;TD colSpan=2 align=middle&gt;&amp;lt;50&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DM4 series magnetic field circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DS12 series DC fast circuit breaker </title>
           <link>http://www.91way.com/info_en/592.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:46:06</pubDate>
           <comments></comments>
           <description>The DS12/DS14 series DC fast circuit breaker is suitable for short-circuit and overload protection in DC circuits with a rated current of 6300A and below at 1500V. Suitable for protection switches of silicon rectifier units and DC motor units in electrified railways, urban traction, mining, steel rolling, chemical industry, and other fields.&lt;BR&gt;&lt;BR&gt;DS12 series DC fast circuit breaker models and their meanings:&lt;BR&gt;&lt;BR&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 461px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;DS12 series DC fast circuit breaker model description&quot; src=&quot;/uploadfiles/200610/2006102711354634.gif&quot; width=461 height=291&gt;&lt;/DIV&gt;Main technical parameters of DS12 series DC fast circuit breaker:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse; HEIGHT: 86px&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center height=86&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=52 width=&quot;13%&quot; align=middle&gt;Set current range A&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=middle&gt;Breaking ability (KA)&lt;BR&gt;six&lt;BR&gt;£¨di/dt=3&#215;10 A/S)&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=middle&gt;Overvoltage during disconnection/test voltage&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;Full break time (ms)&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;Current limiting coefficient&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;Electrical lifespan (times)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=18 align=middle&gt;£¨0.8-2)Ie&lt;/TD&gt;
&lt;TD align=middle&gt;30, 40, 50&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü3&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü0.65&lt;BR&gt;¡Ü0.7&lt;/TD&gt;
&lt;TD align=middle&gt;five thousand&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;model&lt;BR&gt;project&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;DS12-&lt;BR&gt;10/08&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;DS12-&lt;BR&gt;20/08&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;DS12-&lt;BR&gt;30/08&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;DS12-&lt;BR&gt;60/08&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80&gt;
&lt;DIV align=center&gt;DS14-&lt;BR&gt;10/15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;DIV align=center&gt;DS14-&lt;BR&gt;20/15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=76&gt;
&lt;DIV align=center&gt;DS14-&lt;BR&gt;32/15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;DIV align=center&gt;DS14-&lt;BR&gt;63/15&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;800V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;1500V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26 colSpan=2&gt;
&lt;DIV align=center&gt;Rated current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three thousand and two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six thousand and three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Rated current range A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;800-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1600-4000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2400-6000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4800-12000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;800-2000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1600-4000&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2400-6300&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4800-12600&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Mechanical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Electrical lifespan (times)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=50 width=41&gt;
&lt;DIV align=center&gt;close the circuit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;DIV align=center&gt;Voltage V&lt;BR&gt;£¨AC,DC£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/28&lt;BR&gt;110/56&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/28&lt;BR&gt;110/56&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/34&lt;BR&gt;110/68&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/56&lt;BR&gt;110/78&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/28&lt;BR&gt;110/56&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/28&lt;BR&gt;110/56&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/34 110/68&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;220/56&lt;BR&gt;110/98&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DS12 series DC fast circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]DS14 series DC fast circuit breaker DS14-10/15   20/15    32/15</title>
           <link>http://www.91way.com/info_en/591.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:45:57</pubDate>
           <comments></comments>
           <description>Model and its meaning:&lt;BR&gt;&lt;BR&gt;
&lt;DIV align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 461px; HEIGHT: 291px&quot; border=0 hspace=0 alt=&quot;DS14 series DC fast circuit breaker model description&quot; src=&quot;/uploadfiles/200610/200610271121678.gif&quot; width=461 height=291&gt;&lt;/DIV&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=52 width=&quot;13%&quot; align=middle&gt;Set current range A&lt;/TD&gt;
&lt;TD width=&quot;22%&quot; align=middle&gt;Breaking ability (KA)&lt;BR&gt;&lt;SPAN class=style3&gt;six&lt;/SPAN&gt;&lt;BR&gt;£¨di/dt=3&#215;10 A/S)&lt;/TD&gt;
&lt;TD width=&quot;20%&quot; align=middle&gt;Overvoltage during disconnection/test voltage&lt;/TD&gt;
&lt;TD width=&quot;14%&quot; align=middle&gt;Full break time (ms)&lt;/TD&gt;
&lt;TD width=&quot;9%&quot; align=middle&gt;Current limiting coefficient&lt;/TD&gt;
&lt;TD width=&quot;12%&quot; align=middle&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD width=&quot;10%&quot; align=middle&gt;Electrical lifespan (times)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=18 align=middle&gt;£¨0.8-2)Ie&lt;/TD&gt;
&lt;TD align=middle&gt;30, 40, 50&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü3&lt;/TD&gt;
&lt;TD align=middle&gt;thirty&lt;/TD&gt;
&lt;TD align=middle&gt;¡Ü0.65&lt;BR&gt;¡Ü0.7&lt;/TD&gt;
&lt;TD align=middle&gt;five thousand&lt;/TD&gt;
&lt;TD align=middle&gt;500, 400, 100, 50&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DS14 series DC fast circuit breaker&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GMB series three-stage protection DC molded case circuit breaker </title>
           <link>http://www.91way.com/info_en/380.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:45:49</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GMB series three-stage protection DC plastic case circuit breaker is a new type of circuit breaker developed by Beijing People's Electric Appliance Factory using international advanced design and manufacturing technology. Its rated working voltage is DC660V and below, and its rated working current is up to 1250A in circuits. Circuit breakers have short-circuit, overload, and undervoltage protection functions, which can protect the circuit and power equipment from damage.&lt;BR&gt;[Compliant with standards]&lt;BR&gt;IEC60947-1 GB14048.1 General Provisions&lt;BR&gt;IEC60947-2 GB14048.2 Low Voltage Circuit Breakers&lt;BR&gt;IEC60947-4 GB14048.4 Contactors and Motor Starters&lt;BR&gt;IEC60947-5 GB14048.5 Electromechanical Control Circuit Electrical Appliances&lt;BR&gt;&lt;BR&gt;[Features]&lt;BR&gt;The G series fully selective three-stage protection DC circuit breaker adopts the internationally pioneering patented arc extinguishing technology CCV, which is the quadruple acceleration and narrow gap breaking free arc extinguishing technology, making the arcing distance shorter and the breaking capacity higher (DC250V) 20kA, (DC440) 15kA, and Ics=100% Icu.&lt;BR&gt;Small size, accurate short circuit delay, complete specifications&lt;BR&gt;Normally, according to standard specifications, for the differential coordination of battery pack power systems, the calculation of short-circuit current can be simplified without considering parameters such as resistance, cable cross-sectional area, copper content, current limiting coefficient, and cable thermal stability. The upper and lower level circuit breakers only need to be selected according to the rated current level to achieve fully selective three-stage protection, which meets international standards.&lt;BR&gt;The GMB series three-stage protective plastic case circuit breaker adopts the most advanced international hardness and anti-corrosion surface treatment process of soft nitriding and matte electroplating in terms of anti-corrosion performance, which makes the product's anti-corrosion performance higher than nickel plating and suitable for high protection level use.&lt;BR&gt;&lt;BR&gt;[Basic Parameters]&lt;BR&gt;Rated current of shell level: 1002254008001250A&lt;BR&gt;Polar number: 2P&lt;BR&gt;Rated working voltage: DC250V&lt;BR&gt;Ultimate short-circuit breaking capacity: M standard type, H high type, R advanced type&lt;BR&gt;Operation mode: direct operation of the body, P electric operating mechanism, Z rotating handle operation;&lt;BR&gt;Wiring methods: front board wiring, B-board rear wiring, C plug-in wiring&lt;BR&gt;&lt;BR&gt;[Model meaning]&lt;BR&gt;GMB 225 M/2 3 00R 125A&lt;BR&gt;The GMB series shell level rated current is 225A, with a maximum short-circuit breaking capacity of M standard type two pole three-stage protection DC plastic shell circuit breaker. It adopts a compound release (overload long delay+short-circuit short delay), rated working current is 125A, and is wired in front of the board.&lt;BR&gt;&lt;BR&gt;[Operating Environment]&lt;BR&gt;Altitude of 2000m and below;&lt;BR&gt;The temperature of the surrounding medium should not be lower than -5 ¡æ and not higher than 40 ¡æ. If it is higher than 40 ¡æ, it can be used with reduced capacity;&lt;BR&gt;Can withstand the influence of humid air;&lt;BR&gt;Capable of withstanding the effects of salt spray and oil mist;&lt;BR&gt;Can tolerate the influence of mold;&lt;BR&gt;Can work reliably under normal ship vibration;&lt;BR&gt;In a medium without explosive hazards, and where there is no gas or conductive dust that can corrode metals or damage insulation;&lt;BR&gt;In a place without rain or snow invasion.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216142105483.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 653px; HEIGHT: 362px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GMB series three-stage protection DC molded case circuit breaker&quot; src=&quot;/upload2012/201202/20120216142105483.jpg&quot; width=653 height=362&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[DC circuit breaker]GM series DC molded case circuit breaker </title>
           <link>http://www.91way.com/info_en/379.html</link>
           <author></author>
           <guid></guid>
           <category>DC circuit breaker</category>
           <pubDate>2026-6-10 10:45:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The GM series DC molded case circuit breaker is a new type of circuit breaker developed by Beijing People's Electric Appliance Factory using international advanced design and manufacturing technology. Its rated working voltage is DC250V, DC440V, DC660V, DC1140V, and rated working current is up to 1250A in circuits. Circuit breakers have short-circuit, overload, and undervoltage protection functions, which can protect the circuit and power equipment from damage.&lt;BR&gt;&lt;BR&gt;[Compliant with standards]&lt;BR&gt;IEC60947-1 GB14048.1 General Provisions&lt;BR&gt;IEC60947-2 GB14048.2 Low Voltage Circuit Breakers&lt;BR&gt;&lt;BR&gt;[Features]&lt;BR&gt;The GM series molded case circuit breaker adopts patented arc extinguishing technology CCV, which includes quadruple acceleration and narrow gap breaking to eliminate free arc extinguishing technology, achieving zero arcing and higher breaking capacity (DC250V) 20kA, (DC440) 15kA, and Ics=100% Icu. In terms of anti-corrosion performance, the most advanced international process of increasing hardness and anti-corrosion surface treatment, soft nitriding and matte electroplating, is adopted to make the product's anti-corrosion performance higher than nickel plating, suitable for high protection level use, small size, and beautiful appearance. The world's first GM100 series with load indicator lights eliminates the need for dedicated indicator lights on the screen panel, saving space and simplifying the wiring inside the screen.&lt;BR&gt;&lt;BR&gt;[Basic Parameters]&lt;BR&gt;Rated current of shell level: 1002254008001250A&lt;BR&gt;Polar numbers: 2P, 3P, 4P&lt;BR&gt;Rated working voltage: DC250V, DC440V, DC660V, DC1140V&lt;BR&gt;Ultimate short-circuit breaking capacity: M standard type, H high type, R advanced type&lt;BR&gt;Operation mode: direct operation of the body, P electric operating mechanism, Z rotating handle operation;&lt;BR&gt;Wiring methods: front board wiring, B-board rear wiring, C plug-in wiring&lt;BR&gt;&lt;BR&gt;[Model meaning]&lt;BR&gt;GM 225 M/2 3 00R 125A&lt;BR&gt;That is, the GM series shell level rated current is 225A, the ultimate short-circuit breaking capacity is M standard type two pole DC plastic shell circuit breaker, using a compound release (overload long delay+short circuit instantaneous), the rated working current is 125A, and the wiring is in front of the board.&lt;BR&gt;&lt;BR&gt;[Operating Environment]&lt;BR&gt;Altitude of 2000m and below;&lt;BR&gt;The temperature of the surrounding medium should not be lower than -5 ¡æ and not higher than 40 ¡æ. If it is higher than 40 ¡æ, it can be used with reduced capacity;&lt;BR&gt;Can withstand the influence of humid air;&lt;BR&gt;Capable of withstanding the effects of salt spray and oil mist;&lt;BR&gt;Can tolerate the influence of mold;&lt;BR&gt;Can work reliably under normal ship vibration;&lt;BR&gt;In a medium without explosive hazards, and where there is no gas or conductive dust that can corrode metals or damage insulation;&lt;BR&gt;In a place without rain or snow invasion.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216142400705.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 653px; HEIGHT: 362px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GM series DC molded case circuit breaker&quot; src=&quot;/upload2012/201202/20120216142400705.jpg&quot; width=653 height=362&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>