<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - 27.5KV current transformer</title>
       <link>http://www.91way.com</link>
       <description>27.5KV current transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:17:01</pubDate>
       <item>
           <title>[27.5KV current transformer]LZZB8-27.5 type current transformer </title>
           <link>http://www.91way.com/info_en/30296.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV current transformer</category>
           <pubDate>2026-6-20 11:04:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;LZZB8-27.5 type current transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250928134627404.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of LZZB8-27.5 current transformer&quot; src=&quot;/upload2025/202509/20250928134627404.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV current transformer]LZZBJ71-27.5 outdoor current transformer </title>
           <link>http://www.91way.com/info_en/24741.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV current transformer</category>
           <pubDate>2026-6-20 11:04:27</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201403/20140328193532235.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 844px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of LZZBJ71-27.5 outdoor current transformer&quot; src=&quot;/upload2014/201403/20140328193532235.jpg&quot; width=680 height=844&gt;&lt;/A&gt;&lt;BR&gt;LZZBJ71-27.5 Outdoor Current Transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV current transformer]Voltage Transformer for EN_1 Type </title>
           <link>http://www.91way.com/info_en/18070.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV current transformer</category>
           <pubDate>2026-6-20 11:04:18</pubDate>
           <comments></comments>
           <description>JDZX6-20, The 27.5 type CGIS voltage transformer is used in conjunction with the CGIS cabinet, installed outside the SF6 gas chamber and closely matched with the internal cone insulator inside the gas chamber. Used for voltage measurement, energy metering, and relay protection in AC 50-60Hz power systems.&lt;BR&gt;&lt;BR&gt;The JDZX6-20,27.5,35RCQ2 CGIS voltage transformer adopts high-performance iron core, high-quality enameled wire and insulation material. It is insulated by epoxy resin casting and covered with a metal shell or sprayed with metal material to provide shielding and grounding protection, achieving a touchable effect.&lt;BR&gt;&lt;BR&gt;The JDZX6-20,27.5,35RCQ2 CGIS voltage transformer has a small volume, light weight, beautiful appearance, easy installation, adopts advanced design concepts, excellent product performance, accurate measurement, safety and reliability, small partial discharge, and is also equipped with fuse protection. All performance fully meets the GB1207-2006 national standard and IEC60044-2 international electrical standard.&lt;BR&gt;The main technical parameters of JDZX6-20,27.5,35RCQ2 CGIS voltage transformers are as follows:&lt;BR&gt;&lt;BR&gt;Rated insulation level:&lt;BR&gt;24/65/125kV £¨JDZX6-20RCQ2£©&lt;BR&gt;31.5/80/185kV £¨JDZX6-27.5RCQ2£©&lt;BR&gt;40.5/95/200kV £¨JDZX6-35RCQ2£©&lt;BR&gt;&lt;BR&gt;Rated voltage ratio:&lt;BR&gt;24/¡Ì3/0.1/¡Ì3/0.1/¡Ì3/0.1/3kV&lt;BR&gt;27.5/¡Ì3/0.1/¡Ì3/0.1/¡Ì3/0.1/3kV&lt;BR&gt;35/¡Ì3/0.1/¡Ì3/0.1/¡Ì3/0.1/3kV&lt;BR&gt;&lt;BR&gt;Accuracy level: 0.2/0.5/3P&lt;BR&gt;&lt;BR&gt;Rated secondary load:&lt;BR&gt;10/15/50VA&lt;BR&gt;15/20/50 (or 100) VA&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[27.5KV current transformer]LZZBJ-27.5(GYW1) type current transformer </title>
           <link>http://www.91way.com/info_en/8529.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV current transformer</category>
           <pubDate>2026-6-20 11:04:10</pubDate>
           <comments></comments>
           <description>LZZBJ-27.5 (GYW1) current transformer is suitable for areas with an altitude of 1000m and below, and high-altitude products are suitable for areas with an altitude of 2500m and below. It is used for precision electrical measurement and relay protection in power systems with a frequency of 50Hz and a maximum operating voltage of 40.5kV.&lt;BR&gt;Environmental temperature: The normal type is+40 ¡æ~-15 ¡æ; The plateau type ranges from+25 ¡æ to -15 ¡æ.&lt;BR&gt;Product type: Indoor.&lt;BR&gt;Atmospheric conditions: There is no pollution or explosive medium in the installation site that seriously affects the insulation of the transformer.&lt;BR&gt;The installation site has no severe vibrations or bumps.&lt;BR&gt;Open circuit is not allowed during product operation, otherwise there is a high voltage hazard.&lt;BR&gt;The temperature during transportation and storage ranges from+40 ¡æ to -15 ¡æ.&lt;BR&gt;&lt;BR&gt;Technical parameters of LZZBJ-27.5 (GYW1) current transformer&lt;BR&gt;&lt;BR&gt;Product execution standard: GB1208-1997 &quot;Current Transformers&quot;.&lt;BR&gt;Rated secondary current: 5A and 1A.&lt;BR&gt;Instrument security factor: 0.2S level FS ¡Ü 5; Level 0.2 and 0.5 FS ¡Ü 10.&lt;BR&gt;Insulation and heat resistance grade: Grade E.&lt;BR&gt;Secondary structure: two coils, three coils, four coils.&lt;BR&gt;The rated secondary lower limit load is 25% of the rated secondary load.&lt;BR&gt;The rated primary current value, rated secondary load, accurate limit coefficient, rated short-time current value, level combination, and weight are listed in the following table. Please consult with the manufacturer for special specification products.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;insulation level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=406 colSpan=9&gt;
&lt;DIV align=center&gt;Ordinary type: 40.5/95/185kV&lt;BR&gt;Plateau type: 40.5/110/226 kV (below 2500m)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=63 colSpan=2&gt;
&lt;DIV align=center&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=161 colSpan=2&gt;
&lt;DIV align=center&gt;0.2S¡¢0.2¡¢0.5¡¢&lt;BR&gt;5P¡¢10P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;Partial discharge capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=630 colSpan=13&gt;
&lt;DIV align=center&gt;The applied voltage is 80% of the power frequency withstand voltage, and after 60 seconds, it drops to the measured voltage of 28 kV with a discharge capacity of ¡Ü 20pC.&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=91&gt;
&lt;DIV align=center&gt;rated&lt;/DIV&gt;
&lt;DIV align=center&gt;once&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨A£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=364 colSpan=8&gt;
&lt;DIV align=center&gt;Rated secondary load (VA) COS ¦Õ=0.8&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=98 colSpan=2&gt;
&lt;DIV align=center&gt;5P and 10P level standards&lt;/DIV&gt;
&lt;DIV align=center&gt;Limit coefficient&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=84 colSpan=2&gt;
&lt;DIV align=center&gt;1S short-term&lt;/DIV&gt;
&lt;DIV align=center&gt;Thermal current&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=84&gt;
&lt;DIV align=center&gt;Dynamic stability&lt;/DIV&gt;
&lt;DIV align=center&gt;current&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨kA£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91 colSpan=2&gt;
&lt;DIV align=center&gt;0.2S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=91 colSpan=2&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=98 colSpan=2&gt;
&lt;DIV align=center&gt;5P¡¢10P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49&gt;
&lt;DIV align=center&gt;1A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;1A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;1A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;DIV align=center&gt;1A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=42&gt;
&lt;DIV align=center&gt;1A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=56&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=49&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=42&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=42&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=42&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=42&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=49&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=49&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=49&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=42&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=10 width=56&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;six point three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;four point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;twelve&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;six point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;sixteen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;twelve point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;twenty-two point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;thirty-one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;300~500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=91&gt;
&lt;DIV align=center&gt;600~1500&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84 colSpan=2&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;one hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;1. Two coils: Appearance: 405 &#215; 300 &#215; 550 (length &#215; width &#215; height), Level combination: 0.2S/0.2S; 0.2S/5P¡£&lt;BR&gt;2. Three coils: Appearance: 420 &#215; 300 &#215; 550 (length &#215; width &#215; height), Level combination: 0.2S/0.2S/0.2S; 0.2S/0.2S/5P¡£&lt;BR&gt;3. Four coils: Appearance: 480 &#215; 300 &#215; 550 (length &#215; width &#215; height), Level combination: 0.2S/0.2S/0.2S/0.2S; 0.2S/0.2S/5P/5P¡£&lt;BR&gt;4. The measurement levels are interchangeable, and special products with two coils can also be produced using three coil and four coil shapes.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;LZZBJ-27.5 (GYW1) type current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV current transformer]LZZB7-27.5,LZZB7-35GYW1 type current transformer </title>
           <link>http://www.91way.com/info_en/2879.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV current transformer</category>
           <pubDate>2026-6-20 11:04:02</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The LZZB7-27.5 and LZZB7-35GYW1 current transformers are epoxy resin cast fully enclosed pillar structures. Suitable for indoor power systems with a rated voltage of 35KV and below, and a rated frequency of 50HZ or 60HZ, used for current and energy metering and relay protection. The characteristics of this product include high dynamic and thermal stability parameters, large secondary output capacity, stable insulation performance, strong resistance to pollution and moisture, etc. It can completely replace old similar products such as LCZ-35 and LZZ-35Q.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200711/2007119121612943.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 419px; HEIGHT: 95px&quot; border=0 hspace=0 alt=&quot;LZZB7-27.5, LZZB7-35GYW1 Type Current Transformer Model Description&quot; src=&quot;/uploadfiles/200711/2007119121612943.jpg&quot; width=419 height=95&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;3.1 Installation site indoor&lt;BR&gt;3.2 Environmental temperature -5 ¡æ~+40 ¡æ&lt;BR&gt;3.3 Altitude not exceeding 3000 meters&lt;BR&gt;3.4 Pollution level is Level II, with a climbing distance greater than 1000mm&lt;BR&gt;When the relative humidity of the air does not exceed 90 and the temperature is 25 ¡æ&lt;BR&gt;3.6 Gas, steam, dust, and other explosive or corrosive media that do not seriously affect the insulation of transformers&lt;BR&gt;3.7 Installation site without severe vibration and turbulence&lt;BR&gt;&lt;BR&gt;4.1 The product complies with the standards GB1208 and IEC185;&lt;BR&gt;4.2 Rated insulation level 42/95/2000KV;&lt;BR&gt;4.3 Rated secondary current 5A or 1A.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200711/2007119121627203.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 640px; HEIGHT: 609px&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of LZZB7-27.5 and LZZB7-35GYW1 current transformers&quot; src=&quot;/uploadfiles/200711/2007119121627203.jpg&quot; width=640 height=609&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;LZZB7-27.5, LZZB7-35GYW1 current transformers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

