           <title>[27.5KV voltage transformer]JZW-27.5KV type outdoor low magnetic density voltage transformer </title>
           <link>http://www.91way.com/info_en/27571.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:07:10</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2018/201809/20180930213825670.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 633px; HEIGHT: 816px&quot; border=0 hspace=0 alt=&quot;Technical parameters and external dimensions of JZW-27.5KV outdoor low magnetic density voltage transformer&quot; src=&quot;/upload2018/201809/20180930213825670.jpg&quot; width=633 height=816&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JZW-27.5KV Outdoor Low Magnetic Density Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDTN1,JDTN2-27.5 type voltage transformer </title>
           <link>http://www.91way.com/info_en/19729.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:07:01</pubDate>
           <comments></comments>
           <description>The JDTN1-27.5 (formerly JDT1-27.5) and JDTN2-27.5 (formerly JDT2-27.5) series voltage transformers are suitable for measuring the voltage on the traction bus in railway electrified electric traction power supply systems with a rated voltage of 27.5kV and a rated frequency of 50Hz. The JDTN1-27.5 (formerly JDT1-27.5) voltage transformer is a semi insulated structure; The JDTN2-27.5 (formerly JDT2-27.5) voltage transformer is a fully insulated structure.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDZ11-27.5Q type indoor low magnetic density voltage transformer </title>
           <link>http://www.91way.com/info_en/18073.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:06:53</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120209224818997.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 649px; HEIGHT: 824px&quot; border=0 hspace=0 alt=&quot;External dimensions and technical parameters of JDZ11-27.5Q indoor low magnetic density voltage transformer&quot; src=&quot;/upload2012/201202/20120209224818997.jpg&quot; width=649 height=824&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDZ11-27.5Q Indoor Low Magnetic Density Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDZ12-35(27.5) Indoor Cast in place Voltage Transformer </title>
           <link>http://www.91way.com/info_en/16052.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:06:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;Technical Parameters of JDZ12-35 (27.5) Indoor Cast in place Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405143725532.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 533px; HEIGHT: 104px&quot; border=0 hspace=0 alt=&quot;Technical Parameters of JDZ12-35 (27.5) Indoor Cast in place Voltage Transformer&quot; src=&quot;/upload2011/201104/20110405143725532.jpg&quot; width=533 height=104&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDZ12-35 (27.5) Indoor Cast in place Voltage Transformer Dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201104/20110405143746752.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 535px; HEIGHT: 284px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JDZ12-35 (27.5) indoor cast voltage transformer&quot; src=&quot;/upload2011/201104/20110405143746752.jpg&quot; width=535 height=284&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDZ12-35 (27.5) Indoor Cast in place Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDZ9-27.5 type voltage transformer </title>
           <link>http://www.91way.com/info_en/8535.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:06:36</pubDate>
           <comments></comments>
           <description>The JDZ9-27.5 voltage transformer is a single-phase double winding and three winding epoxy resin cast fully enclosed indoor device voltage transformer, suitable for precise voltage and energy measurement and relay protection in AC systems with a rated frequency of 50Hz and a maximum working voltage of 40.5kV (nominal voltage 27.5kV).&lt;BR&gt;&#183;Environmental temperature: The normal type is+40 ¡æ~-15 ¡æ; The plateau type ranges from+25 ¡æ to -15 ¡æ.&lt;BR&gt;&#183;Environmental humidity: The daily average relative humidity should not exceed 95%, and the monthly average should not exceed 90%; The daily average saturated vapor pressure shall not exceed 2.2 &#215; 10-3MPa, and the monthly average shall not exceed 1.8 &#215; 10-3MPa.&lt;BR&gt;&#183;Product type: Indoor.&lt;BR&gt;&#183;Atmospheric conditions: There is no pollution or explosive medium in the installation site that seriously affects the insulation of the transformer.&lt;BR&gt;&#183;The installation site has no severe vibrations or bumps-&lt;BR&gt;&#183;Open circuit is not allowed during product operation, otherwise there is a high voltage hazard.&lt;BR&gt;&#183;The temperature during transportation and storage ranges from+40 ¡æ to -15 ¡æ.&lt;BR&gt;&#183;When using the product, the equipotential lead wire should be reliably connected to the high-voltage bus.&lt;BR&gt;¡ù Technical Parameters ¡ù&lt;BR&gt;&#183;Product execution standard: GB1207-1997 &quot;Voltage Transformers&quot;.&lt;BR&gt;&#183;Rated insulation level: 40.5/95/200kV.&lt;BR&gt;&#183;Insulation and heat resistance grade: Grade E.&lt;BR&gt;&#183;The impulse test voltage of JDZ9-27.5 voltage transformer complies with the provisions of GB311-64, that is, the full wave is 200kV, the cut-off wave is 230kV, and the induced test voltage value is 80kV, 15s (400Hz). The secondary winding is connected to ground at 3kV for 1 minute.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 70%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;70%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=105&gt;
&lt;DIV align=center&gt;Rated voltage ratio (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Accurate level or level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;Rated output (VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;Maximum output (VA)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=75&gt;
&lt;DIV align=center&gt;JDZ9-27.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=105&gt;
&lt;DIV align=center&gt;27500/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Level 0.2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=72&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Level 0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;one hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Level 1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;three hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD vAlign=top width=105&gt;
&lt;DIV align=center&gt;27500/100/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Level 0.2/0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;30/50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=72&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JDZ9-27.5 Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDZX9-27.5 type voltage transformer </title>
           <link>http://www.91way.com/info_en/8534.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:06:28</pubDate>
           <comments></comments>
           <description>The JDZX9-27.5 voltage transformer is a single-phase double winding and three winding epoxy resin cast fully enclosed indoor device voltage transformer, suitable for precise voltage and energy measurement and relay protection in AC systems with a rated frequency of 50Hz and a maximum working voltage of 40.5kV (nominal voltage 27.5kV).&lt;BR&gt;&#183;Environmental temperature: The normal type is+40 ¡æ~-15 ¡æ; The plateau type ranges from+25 ¡æ to -15 ¡æ.&lt;BR&gt;&#183;Environmental humidity: The daily average relative humidity should not exceed 95%, and the monthly average should not exceed 90%; The daily average saturated vapor pressure shall not exceed 2.2 &#215; 10-3MPa, and the monthly average shall not exceed 1.8 &#215; 10-3MPa.&lt;BR&gt;&#183;Product type: Indoor.&lt;BR&gt;&#183;Atmospheric conditions: There is no pollution or explosive medium in the installation site that seriously affects the insulation of the transformer.&lt;BR&gt;&#183;The installation site has no severe vibrations or bumps-&lt;BR&gt;&#183;Open circuit is not allowed during product operation, otherwise there is a high voltage hazard.&lt;BR&gt;&#183;The temperature during transportation and storage ranges from+40 ¡æ to -15 ¡æ.&lt;BR&gt;&#183;When using the product, the equipotential lead wire should be reliably connected to the high-voltage bus.&lt;BR&gt;¡ù Technical Parameters ¡ù&lt;BR&gt;&#183;Product execution standard: GB1207-1997 &quot;Voltage Transformers&quot;.&lt;BR&gt;&#183;Rated insulation level: 40.5/95/200kV.&lt;BR&gt;&#183;Insulation and heat resistance grade: Grade E.&lt;BR&gt;&#183;The impulse test voltage of the transformer complies with the provisions of GB311-64, which means that the full wave is 200kV, the cut-off wave is 230kV, and the induced test voltage value is 80kV, 15s (400Hz). The secondary winding is connected to ground at 3kV for 1 minute.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=165&gt;
&lt;DIV align=center&gt;Rated voltage ratio (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Accurate level or level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;Rated output (VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=69&gt;
&lt;DIV align=center&gt;Maximum output (VA)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=75&gt;
&lt;DIV align=center&gt;JDZX9-27.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top rowSpan=3 width=165&gt;
&lt;DIV align=center&gt;27500/¡Ì3&lt;/DIV&gt;
&lt;DIV align=center&gt;100/¡Ì3£º100/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;0.2/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;30/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=69&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;0.5/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;90/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;1/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;180/100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=165&gt;
&lt;DIV align=center&gt;27500/¡Ì3&lt;/DIV&gt;
&lt;DIV align=center&gt;100/¡Ì3£º100/¡Ì3£º100/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;0.2/0.5/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=75&gt;
&lt;DIV align=center&gt;20/30/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=69&gt;
&lt;DIV align=center&gt;three hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JDZX9-27.5 Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[27.5KV voltage transformer]JDT-27.5 High Voltage Voltage Transformer </title>
           <link>http://www.91way.com/info_en/4232.html</link>
           <author></author>
           <guid></guid>
           <category>27.5KV voltage transformer</category>
           <pubDate>2026-6-20 11:06:20</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JDT-27.5 High Voltage Voltage Transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718065702324.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 600px; HEIGHT: 283px&quot; border=0 hspace=0 alt=&quot;JDT-27.5 High Voltage Voltage Transformer Appearance and Installation Dimensions&quot; src=&quot;/upload2013/201307/20130718065702324.jpg&quot; width=600 height=283&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDT-27.5 High Voltage Voltage Transformer&lt;BR&gt;&lt;/P&gt;</description>