<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Combination type transformer</title>
       <link>http://www.91way.com</link>
       <description>Combination type transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:07:33</pubDate>
       <item>
           <title>[Combination type transformer]JLSZV-12WG type combination transformer </title>
           <link>http://www.91way.com/info_en/30289.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 15:00:11</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JLSZV-12WG type combination transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2025/202509/20250928123511373.jpg&quot; target=_blank&gt;&lt;IMG border=0 alt=&quot;Technical parameters of JLSZV-12WG combination transformer&quot; src=&quot;/upload2025/202509/20250928123511373.jpg&quot; width=680&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV5-10W series high-voltage current voltage combination transformer </title>
           <link>http://www.91way.com/info_en/27935.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 11:21:40</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JLSZV5-10W series high-voltage current voltage combination transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202408/20240807133045864.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 671px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV5-10W series high-voltage current voltage combination transformer&quot; src=&quot;/upload2024/202408/20240807133045864.jpg&quot; width=680 height=671&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2024/202408/20240807133057760.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 617px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JLSZV5-10W series high-voltage current voltage combination transformer&quot; src=&quot;/upload2024/202408/20240807133057760.jpg&quot; width=680 height=617&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZW-6 outdoor dry-type combination transformer </title>
           <link>http://www.91way.com/info_en/26161.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 11:06:07</pubDate>
           <comments></comments>
           <description>&lt;P&gt;JLSZW-6 outdoor dry-type combination transformer&lt;BR&gt;&lt;BR&gt;1. Rated voltage: 6kV&lt;BR&gt;2. Accuracy level: 0.5 and 0.2 levels, 0.5S and 0.2S levels;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141212152352213.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 234px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline and installation dimensions of JLSZW-6 outdoor dry-type combination transformer&quot; src=&quot;/upload2014/201412/20141212152352213.jpg&quot; width=680 height=234&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141212152403614.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 236px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZW-6 outdoor dry-type combination transformer&quot; src=&quot;/upload2014/201412/20141212152403614.jpg&quot; width=680 height=236&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141212152412995.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 252px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZW-6 outdoor dry-type combination transformer&quot; src=&quot;/upload2014/201412/20141212152412995.jpg&quot; width=680 height=252&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]LGXQ type photoelectric current voltage combination transformer </title>
           <link>http://www.91way.com/info_en/24753.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:44:43</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201403/20140329160714818.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 439px; WIDTH: 563px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of LGXQ photoelectric current voltage combination transformer&quot; src=&quot;/upload2014/201403/20140329160714818.jpg&quot; width=563 height=439&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LGXQ type photoelectric current voltage combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]Electronic combination transformer </title>
           <link>http://www.91way.com/info_en/24752.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:44:32</pubDate>
           <comments></comments>
           <description>The JLSGB electronic current voltage combination transformer is an outdoor device designed specifically for 35kV~220kV power systems.&lt;BR&gt;Suitable for power systems with a rated frequency of 50Hz (or 60Hz) and a rated voltage of 35kV~220kV, providing current and voltage in the primary system for metering and relay protection.&lt;BR&gt;reference standard&lt;BR&gt;GB/T 20840.7 &quot;Transformers - Part 7: Electronic Voltage Transformers&quot;&lt;BR&gt;GB/T 20840.8 &quot;Transformers - Part 8: Electronic Current Transformers&quot;&lt;BR&gt;GB/T 1208 &quot;Current Transformers&quot;&lt;BR&gt;&lt;BR&gt;Introduction to the Structure of JLSGB-35~220kV Electronic Combination Transformer&lt;BR&gt;The main insulation adopts the LGB type high-voltage current transformer, and the outer insulation is a silicone rubber outer sheath and umbrella skirt. It is small in size, light in weight, easy to operate and maintain, anti pollution flash, fireproof, and explosion-proof.&lt;BR&gt;The secondary part adopts an iron core coil type low-power current transformer winding, which is connected in series with a &quot;terminal screen current and voltage forming circuit&quot; in the capacitor core grounding (terminal screen) circuit. The analog-to-digital conversion device consists of an analog-to-digital conversion circuit, a digital optical conversion circuit, a merging unit, and a DC power supply. The voltage forming circuit outputs an analog voltage, which is converted into data transmitted in the form of optical signals.&lt;BR&gt;&lt;BR&gt;Technical parameters of JLSGB-35~220kV electronic combination transformer&lt;BR&gt;Rated voltage: 35kV, 66kV, 110kV, 220kV&lt;BR&gt;Rated primary current: 50-3000A&lt;BR&gt;Measurement accuracy: 0.2S&lt;BR&gt;Protection level accuracy: 3P (voltage), 5P, 5TPE (current), 6P (voltage)&lt;BR&gt;The conversion of current and voltage shall use 2D41H (decimal 11585) rated input voltage &#177; 5V analog-to-digital conversion circuit uniformly&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZ8-10GY Outdoor high-voltage electric energy metering box </title>
           <link>http://www.91way.com/info_en/23559.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:31:50</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718062400551.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 448px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box Model Description&quot; src=&quot;/upload2013/201307/20130718062400551.jpg&quot; width=600 height=448&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;This type of voltage and current combination transformer (also known as an energy metering box) is used for measuring active and reactive energy in AC 50Hz, rated voltage 10kV three-phase power lines. Suitable for outdoor substations in rural areas, as well as small substations and distribution stations in industrial enterprises. This product can replace the JLS-10 oil immersed energy metering box.&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;This type of voltage and current combination transformer (also known as an energy metering box) is used for measuring active and reactive energy in AC 50Hz, rated voltage 10kV three-phase power lines. Suitable for outdoor substations in rural areas, as well as small substations and distribution stations in industrial enterprises. This product can replace the JLS-10 oil immersed energy metering box.&lt;BR&gt;&lt;BR&gt;Technical parameters:&lt;BR&gt;Pollution level: Level IV;&lt;BR&gt;This type of combination transformer is composed of a single-phase voltage transformer and a single-phase current transformer combined into three phases, and the voltage transformer is wired with V/V-12;&lt;BR&gt;This type of combination transformer meets the requirements of GB1208 &quot;Current Transformers&quot;, GB1207 &quot;Electromagnetic Voltage Transformers&quot;, and GB17201 &quot;Combination Transformers&quot;;&lt;BR&gt;The rated voltage ratio of the voltage transformer is 10000/100 (V), and the rated secondary output is 0.2 level 15VA;&lt;BR&gt;Load power factor COS ¦Õ=0.8 (lag);&lt;BR&gt;The safety factor FS of the current transformer instrument is ¡Ü 10;&lt;BR&gt;Environmental temperature: between -30 ¡æ and 40 ¡æ. The daily average temperature does not exceed 30 ¡æ;&lt;BR&gt;Altitude: ¡Ü 4000m;&lt;BR&gt;&lt;BR&gt;The technical parameters of JLSZ8-10GY outdoor high-voltage electric energy metering box are shown in the following table:&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718062427215.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 281px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZ8-10GY outdoor high-voltage electric energy metering box&quot; src=&quot;/upload2013/201307/20130718062427215.jpg&quot; width=600 height=281&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;&lt;BR&gt;JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box Appearance and Installation Dimensions:&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718062449787.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 502px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions and wiring diagram of JLSZ8-10GY outdoor high-voltage electric energy metering box&quot; src=&quot;/upload2013/201307/20130718062449787.jpg&quot; width=600 height=502&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZ8-10GY Outdoor High Voltage Electric Energy Metering Box&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZY-35W Combination Transformer </title>
           <link>http://www.91way.com/info_en/22969.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:11:29</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718063659521.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 600px; HEIGHT: 363px&quot; border=0 hspace=0 alt=&quot;JLSZY-35W Combination Transformer Model Description&quot; src=&quot;/upload2013/201307/20130718063659521.jpg&quot; width=600 height=363&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;The JLSZY-35W combined transformer (also known as an electric energy metering box) is used for measuring active and reactive energy in three-phase power lines with AC 50Hz and rated voltage of 35kV. Suitable for outdoor substations in rural areas, as well as small substations and distribution stations in industrial enterprises. This product can replace the JLS-35 oil immersed energy metering box.&lt;BR&gt;&lt;BR&gt;Structural characteristics:&lt;BR&gt;This type of combination transformer is an outdoor epoxy resin cast, fully enclosed, pillar type structure. Due to the use of outdoor epoxy resin casting, the product has the characteristics of arc resistance, UV resistance, aging resistance, long service life, and maintenance free. This product consists of three single-phase grounded voltage transformers connected in a &quot;Y&quot; shape. Two current transformers are connected in series on phases A and C, and the secondary winding of the current transformers has taps to obtain different current ratios.&lt;BR&gt;The secondary outlet is led out through a metal hose, which is easy to wire, safe and reliable, and can achieve anti-theft measures. There are four mounting holes on the base channel steel for installation.&lt;BR&gt;&lt;BR&gt;Technical parameters of JLSZY-35W combined transformer:&lt;BR&gt;Pollution level: Level IV;&lt;BR&gt;This type of combination transformer consists of three single-phase grounded voltage transformers and two single-phase current transformers combined into three phases, with Y/Y wiring for the voltage transformers;&lt;BR&gt;This type of combination transformer meets the requirements of GB1208 &quot;Current Transformers&quot;, GB1207 &quot;Electromagnetic Voltage Transformers&quot;, and GB17201 &quot;Combination Transformers&quot;;&lt;BR&gt;The rated voltage ratio of the voltage transformer is 35000/100 (V), and the rated secondary output is 0.2 level 30VA;&lt;BR&gt;Load power factor: COS ¦µ=0.8 (lag)&lt;BR&gt;Security factor of current transformer instrument: FS ¡Ü 10;&lt;BR&gt;Environmental temperature: between -30 ¡æ and 40 ¡æ. The daily average temperature does not exceed 30 ¡æ;&lt;BR&gt;Altitude: ¡Ü 4000m;&lt;BR&gt;&lt;BR&gt;Technical parameters of JLSZY-35W combined transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718063714619.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 600px; HEIGHT: 270px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZY-35W combined transformer&quot; src=&quot;/upload2013/201307/20130718063714619.jpg&quot; width=600 height=270&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130718063720508.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 600px; HEIGHT: 523px&quot; border=0 hspace=0 alt=&quot;JLSZY-35W Combination Transformer Appearance and Installation Dimensions&quot; src=&quot;/upload2013/201307/20130718063720508.jpg&quot; width=600 height=523&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZY-35W Combination Transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-10B type combination transformer </title>
           <link>http://www.91way.com/info_en/22831.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:11:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203817698.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 658px; HEIGHT: 148px&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-10B Combination Transformer&quot; src=&quot;/upload2013/201302/20130223203817698.jpg&quot; width=658 height=148&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203826545.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 256px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-10B combination transformer&quot; src=&quot;/upload2013/201302/20130223203826545.jpg&quot; width=680 height=256&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203840621.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 376px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZV-10B combination transformer&quot; src=&quot;/upload2013/201302/20130223203840621.jpg&quot; width=680 height=376&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203849668.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;JLSZV-10B type combination transformer appearance and installation dimensions&quot; src=&quot;/upload2013/201302/20130223203849668.jpg&quot; width=680 height=416&gt;&lt;/A&gt;&lt;BR&gt;JLSZV-10B type combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-6B type combination transformer </title>
           <link>http://www.91way.com/info_en/22830.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:10:55</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203651538.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 658px; HEIGHT: 148px&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-6B Combination Transformer&quot; src=&quot;/upload2013/201302/20130223203651538.jpg&quot; width=658 height=148&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203703743.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 256px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-6B combination transformer&quot; src=&quot;/upload2013/201302/20130223203703743.jpg&quot; width=680 height=256&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203712312.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 376px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZV-6B combination transformer&quot; src=&quot;/upload2013/201302/20130223203712312.jpg&quot; width=680 height=376&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203720904.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;JLSZV-6B type combination transformer appearance and installation dimensions&quot; src=&quot;/upload2013/201302/20130223203720904.jpg&quot; width=680 height=416&gt;&lt;/A&gt;&lt;BR&gt;JLSZV-6B type combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-3B type combination transformer </title>
           <link>http://www.91way.com/info_en/22829.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-14 10:10:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203506294.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 658px; HEIGHT: 148px&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-3B Combination Transformer&quot; src=&quot;/upload2013/201302/20130223203506294.jpg&quot; width=658 height=148&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203516935.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 256px&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-3B combination transformer&quot; src=&quot;/upload2013/201302/20130223203516935.jpg&quot; width=680 height=256&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203525956.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 376px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZV-3B combination transformer&quot; src=&quot;/upload2013/201302/20130223203525956.jpg&quot; width=680 height=376&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201302/20130223203534693.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: none; WIDTH: 680px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JLSZV-3B combination transformer&quot; src=&quot;/upload2013/201302/20130223203534693.jpg&quot; width=680 height=416&gt;&lt;/A&gt;&lt;BR&gt;JLSZV-3B type combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVW7-35 outdoor dry-type three-phase combination transformer </title>
           <link>http://www.91way.com/info_en/18110.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 21:20:54</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201202/20120210094945748.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 838px; WIDTH: 657px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZVW7-35 Outdoor Dry type Three phase Combination Transformer&quot; src=&quot;/upload2012/201202/20120210094945748.jpg&quot; width=657 height=838&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201202/20120210094953660.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 832px; WIDTH: 667px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions and technical parameters of JLSZVW7-35 outdoor dry-type three-phase combination transformer&quot; src=&quot;/upload2012/201202/20120210094953660.jpg&quot; width=667 height=832&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZVW7-35 Outdoor Dry type Three phase Combination Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVW8-10G type combined transformer for anti-theft electricity metering </title>
           <link>http://www.91way.com/info_en/18109.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 21:20:45</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120210094650774.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 828px; WIDTH: 669px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZVW8-10G type combined transformer for anti-theft electricity metering, external dimensions and technical parameters&quot; src=&quot;/upload2012/201202/20120210094650774.jpg&quot; width=669 height=828&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZVW8-10G type combined transformer for anti-theft electricity metering&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVW7-10 outdoor dry-type three-phase combination transformer </title>
           <link>http://www.91way.com/info_en/18108.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 21:20:36</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201202/20120210094409186.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 810px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Selection Instructions for JLSZVW7-10 Outdoor Dry type Three phase Combination Transformer&quot; src=&quot;/upload2012/201202/20120210094409186.jpg&quot; width=680 height=810&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2012/201202/20120210094418168.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 842px; WIDTH: 655px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JLSZVW7-10 outdoor dry-type three-phase combination transformer&quot; src=&quot;/upload2012/201202/20120210094418168.jpg&quot; width=655 height=842&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZVW7-10 Outdoor Dry type Three phase Combination Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZ5-10 Combination Transformer </title>
           <link>http://www.91way.com/info_en/15391.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 21:12:25</pubDate>
           <comments></comments>
           <description>The JLSZ5-10 combination transformer (hereinafter referred to as the combination transformer) is suitable for measuring active and reactive energy in outdoor power systems with a frequency of 50Hz and a voltage of 10kV.&lt;BR&gt;Installation location: Outdoor.&lt;BR&gt;Environmental temperature: up to 40 ¡æ; Minimum -25 ¡æ; The daily average temperature cannot exceed 30 ¡æ.&lt;BR&gt;Altitude: not exceeding 1000m.&lt;BR&gt;Atmospheric conditions: There is no severe pollution in the atmosphere.&lt;BR&gt;The product implementation standard is GB17201 &quot;Combination Transformer&quot;.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLDZ-6R type voltage transformer </title>
           <link>http://www.91way.com/info_en/5760.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:40:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200906/2009628113922345.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 942px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JLDZ-10,6R voltage transformer&quot; src=&quot;/uploadfiles/200906/2009628113922345.jpg&quot; width=680 height=942&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLDZ-10,6R Voltage Transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]YFJLSZ-6,10 Prepaid combination transformer </title>
           <link>http://www.91way.com/info_en/4951.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:37:50</pubDate>
           <comments></comments>
           <description>YFJLSZ-6¡¢ 10 prepaid combination transformers are suitable for pre paid metering and protection in branch and dedicated transformers of rated frequency 50HZ and rated voltage 6-10KV power systems. They are equipped with superior permanent magnet vacuum circuit breakers, which can cut off overload currents (adjustable) and short-circuit currents of 20KA, effectively protecting electrical equipment and completely eliminating the problem of electricity bill collection. The dry-type maintenance free, metering, and protection separate magnetic circuits do not interfere with each other, and the metering accuracy reaches 0.2S level. The current transformation ratio can be selected, and the dual transformation ratio can be used to expand the scope of use. Small metering and large protection make the product more superior, with strong anti-theft ability. The use of aviation plug wiring makes equipment installation easier, and the lead sealing is tight. And it can be sealed with lead. The product has strong integration, reasonable structure, and superior three proof performance. 
&lt;P&gt;YFJLSZ-6, Technical parameters of 10 prepaid combination transformers:&lt;BR&gt;&lt;BR&gt;Rated frequency: 50HZ&lt;BR&gt;Rated primary current: 5-600A&lt;BR&gt;Rated secondary current: 5A&lt;BR&gt;Rated secondary voltage: 100V&lt;BR&gt;Circuit breaker switch power supply voltage: 90V&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200941201558752.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 400px; WIDTH: 523px; FILTER: none&quot; border=0 hspace=0 alt=&quot;YFJLSZ-6, 10. Prepaid combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200904/200941201558752.jpg&quot; width=523 height=400&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/20094120167827.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 128px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;YFJLSZ-6, 10. Wiring diagram of prepaid combination transformer&quot; src=&quot;/uploadfiles/200904/20094120167827.jpg&quot; width=500 height=128&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;YFJLSZ-6¡¢ 10 prepaid combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-35W outdoor three-phase three wire combination transformer </title>
           <link>http://www.91way.com/info_en/4476.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:27:44</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200809/200891673824999.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 480px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-35W Outdoor Three phase Three wire Combination Transformer&quot; src=&quot;/uploadfiles/200809/200891673824999.jpg&quot; width=600 height=480&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200809/200891673839815.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 480px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-35W outdoor three-phase three wire combination transformer&quot; src=&quot;/uploadfiles/200809/200891673839815.jpg&quot; width=600 height=480&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200809/200891673851786.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 762px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline and installation dimensions of JLSZV-35W outdoor three-phase three wire combination transformer&quot; src=&quot;/uploadfiles/200809/200891673851786.jpg&quot; width=600 height=762&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZV-35W outdoor three-phase three wire combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLDZ8-10 outdoor winding injection type combination transformer </title>
           <link>http://www.91way.com/info_en/4471.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:27:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The JLDZ8-10 outdoor winding injection type combination transformer adopts an epoxy resin casting fully enclosed structure, which is maintenance free,&lt;BR&gt;Characteristics of all operating conditions. Voltage transformers have overvoltage resistance and are designed with low magnetic flux density. Current transformers have high dynamic and thermal stability. This type of combination transformer FDK4-12/D400-16 electromagnetic AC high-voltage automatic sectionalizer is used in conjunction with it.&lt;BR&gt;&lt;BR&gt;Technical parameters of JLDZ8-10 outdoor winding injection type combination transformer&lt;BR&gt;Voltage Transformer:&lt;BR&gt;(1) Electrical circuit: (see Figure 1)&lt;BR&gt;(2) Accuracy level:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200809/2008915205225306.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 99px; WIDTH: 360px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Voltage level of JLDZ8-10 outdoor winding injection type combination transformer&quot; src=&quot;/uploadfiles/200809/2008915205225306.jpg&quot; width=360 height=99&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Current transformer:&lt;BR&gt;(1) Electrical circuit diagram: (see Figure 1)&lt;BR&gt;(2) Transformation ratio: 400A/16V&lt;BR&gt;(3) Accuracy:&lt;BR&gt;a. Linearity less than 2%&lt;BR&gt;b. Accuracy better than &#177; 3%&lt;BR&gt;c. The asymmetry between phase A and phase B is less than 1%&lt;BR&gt;(4) Dynamic and thermal stable current:&lt;BR&gt;Thermal stability current: 16KA/2S&lt;BR&gt;Dynamic stable current: 40KA/0.3S&lt;BR&gt;Rated insulation level: 12/42/75KV&lt;BR&gt;Installation, maintenance, and precautions&lt;BR&gt;The installation base plate of this product is welded with channel steel, and the surface is hot-dip galvanized. There are four straight installation holes on the base plate, and users can directly fix the base plate on the metal component. There are two lifting rings on the base plate for easy lifting.&lt;BR&gt;The secondary part of this product is connected to the user equipment control cabinet using an outdoor waterproof aviation plug, making installation very convenient.&lt;BR&gt;The following points should be noted during the use of this product:&lt;BR&gt;¢Ù Short circuits are strictly prohibited at the secondary terminals of voltage transformers.&lt;BR&gt;¢Ú To avoid the impact of external forces on high-voltage insulators, when the insulation surface is damaged, the insulation capacity and internal abnormalities should be checked in a timely manner.&lt;BR&gt;¢Û The product should be stored in a dry, non corrosive gas environment.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200809/2008915205249850.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 800px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLDZ8-10 outdoor winding injection type combination transformer&quot; src=&quot;/uploadfiles/200809/2008915205249850.jpg&quot; width=680 height=800&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLDZ8-10 outdoor winding injection type combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JSZV1-10W dry-type combined voltage transformer </title>
           <link>http://www.91way.com/info_en/4207.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:23:45</pubDate>
           <comments></comments>
           <description>&lt;DIV&gt;The JSZV1-10W dry-type combined voltage transformer is an epoxy resin cast fully enclosed structure used for voltage and energy measurement and relay protection in power systems with a rated frequency of 50HZ and a rated voltage of 10KV and below where the neutral point is not effectively grounded. This transformer is a newly developed V-shaped wiring voltage transformer with fuse protection for the primary winding. It has the characteristics of large creepage distance, low magnetic density, and strong anti resonance ability.&lt;/DIV&gt;
&lt;DIV&gt;&lt;BR&gt;2¡¢ Technical parameters of JSZV1-10W dry-type combined voltage transformer&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;Rated voltage ratio (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;DIV align=center&gt;accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;Rated output (VA)&lt;/DIV&gt;
&lt;DIV align=center&gt;Cos=0.8 (lag)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=55&gt;
&lt;DIV align=center&gt;Maximum output (VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=66&gt;
&lt;DIV align=center&gt;Rated insulation level (KV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=77&gt;
&lt;DIV align=center&gt;Fuse model and rated current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;DIV align=center&gt;Minimum breaking current of fuse&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;1000/100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=62&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=111&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;
&lt;DIV align=center&gt;eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=55&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=66&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=77&gt;
&lt;DIV align=center&gt;XRNP¡õ-12&lt;/DIV&gt;
&lt;DIV align=center&gt;0.3A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=73&gt;
&lt;DIV align=center&gt;0.9A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;10000/220&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=100&gt;
&lt;DIV align=center&gt;10000/100/100&lt;/DIV&gt;
&lt;DIV align=center&gt;10000/100/220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=62&gt;
&lt;DIV align=center&gt;0.2/0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=111&gt;
&lt;DIV align=center&gt;20/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV&gt;Note: If there are special requirements, they can be determined after consultation with our factory.&lt;/DIV&gt;
&lt;DIV&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;3¡¢ Appearance and installation dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/200881212442451.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 294px; WIDTH: 560px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of JSZV1-10W dry-type combined voltage transformer&quot; src=&quot;/uploadfiles/200808/200881212442451.jpg&quot; width=560 height=294&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/200881212458367.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 271px; WIDTH: 551px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of JSZV1-10W dry-type combined voltage transformer&quot; src=&quot;/uploadfiles/200808/200881212458367.jpg&quot; width=551 height=271&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200808/200881212512945.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 354px; WIDTH: 544px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JSZV1-10W dry-type combined voltage transformer&quot; src=&quot;/uploadfiles/200808/200881212512945.jpg&quot; width=544 height=354&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JSZV1-10W dry-type combined voltage transformer&lt;BR&gt;&lt;/DIV&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JDZ8-10C3 series combination transformer </title>
           <link>http://www.91way.com/info_en/3552.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:47</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008517115133996.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 720px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JDZ8-10C3 series combination transformer model description&quot; src=&quot;/uploadfiles/200805/2008517115133996.jpg&quot; width=680 height=720&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517115151173.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 835px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JDZ8-10C3 series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008517115151173.jpg&quot; width=680 height=835&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851711529761.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 805px; WIDTH: 601px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of JDZ8-10C3 series combination transformer&quot; src=&quot;/uploadfiles/200805/200851711529761.jpg&quot; width=601 height=805&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JDZ8-10C3 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]LZZBJ8-10C3 series combination transformer </title>
           <link>http://www.91way.com/info_en/3551.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:38</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008517114919880.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 630px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;LZZBJ8-10C3 series combination transformer model description&quot; src=&quot;/uploadfiles/200805/2008517114919880.jpg&quot; width=680 height=630&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517114946833.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 835px; WIDTH: 588px; FILTER: none&quot; border=0 hspace=0 alt=&quot;LZZBJ8-10C3 series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008517114946833.jpg&quot; width=588 height=835&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851711506535.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 805px; WIDTH: 601px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of LZZBJ8-10C3 series combination transformer&quot; src=&quot;/uploadfiles/200805/200851711506535.jpg&quot; width=601 height=805&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;LZZBJ8-10C3 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]ZJ8-10R series combination transformer </title>
           <link>http://www.91way.com/info_en/3550.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:29</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008517114718183.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 700px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZJ8-10R series combination transformer model description&quot; src=&quot;/uploadfiles/200805/2008517114718183.jpg&quot; width=680 height=700&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517114750232.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 835px; WIDTH: 588px; FILTER: none&quot; border=0 hspace=0 alt=&quot;ZJ8-10R series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008517114750232.jpg&quot; width=588 height=835&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851711488877.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 805px; WIDTH: 601px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of ZJ8-10R series combination transformer&quot; src=&quot;/uploadfiles/200805/200851711488877.jpg&quot; width=601 height=805&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;ZJ8-10R series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV6-12W series combination transformer </title>
           <link>http://www.91way.com/info_en/3549.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:21</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008517105928444.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV6-12W Series Combination Transformer&quot; src=&quot;/uploadfiles/200805/2008517105928444.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517105938434.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV6-12W series combination transformer&quot; src=&quot;/uploadfiles/200805/2008517105938434.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008517105948876.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 556px; WIDTH: 580px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV6-12W series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/2008517105948876.jpg&quot; width=580 height=556&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085171102405.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV6-12W series combination transformer current transformer parameters&quot; src=&quot;/uploadfiles/200805/20085171102405.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZV6-12W series combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-10W series combination transformer </title>
           <link>http://www.91way.com/info_en/3548.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:11</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200851795813187.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-10W Series Combination Transformer&quot; src=&quot;/uploadfiles/200805/200851795813187.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851795826261.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 449px; WIDTH: 621px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV-10W series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200851795826261.jpg&quot; width=621 height=449&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851795838395.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-10W series combination transformer&quot; src=&quot;/uploadfiles/200805/200851795838395.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851795848275.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV-10W series combination transformer current level&quot; src=&quot;/uploadfiles/200805/200851795848275.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZV-10W series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV-10 series combination transformer </title>
           <link>http://www.91way.com/info_en/3547.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:12:03</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200851795429653.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLSZV-10 Series Combination Transformer&quot; src=&quot;/uploadfiles/200805/200851795429653.jpg&quot; width=680 height=170&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851795446824.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 130px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV-10 series combination transformer&quot; src=&quot;/uploadfiles/200805/200851795446824.jpg&quot; width=680 height=130&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085179553834.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 230px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV-10 series combination transformer current level&quot; src=&quot;/uploadfiles/200805/20085179553834.jpg&quot; width=680 height=230&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851795515453.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 784px; WIDTH: 550px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV-10 series combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200805/200851795515453.jpg&quot; width=550 height=784&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2019/201905/20190513142656474.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 262px; WIDTH: 451px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of JLSZV-10 series combination transformer&quot; src=&quot;/upload2019/201905/20190513142656474.jpg&quot; width=451 height=262&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;JLSZV-10 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLDZ-10R series combination transformer </title>
           <link>http://www.91way.com/info_en/3546.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:11:54</pubDate>
           <comments></comments>
           <description>1¡¢ Overview&lt;BR&gt;The JLDZ-10R combination transformer is a fully enclosed structure with epoxy resin casting insulation, suitable for measuring current, voltage, and energy in indoor power systems with a rated voltage of 6 kV, 10 kV, and below, and for relay protection.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110816091706367.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 196px; WIDTH: 324px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of JLDZ-10R Series Combination Transformer&quot; src=&quot;/upload2011/201108/20110816091706367.jpg&quot; width=324 height=196&gt;&lt;/A&gt;&lt;BR&gt;3¡¢ Structure Introduction&lt;BR&gt;The JLDZ-10R series combination transformer has the characteristics of small size, beautiful appearance, and excellent insulation performance. In addition, a high-voltage fuse is added at the connection between the primary winding of the voltage transformer and the primary winding of the current transformer, which has self-protection and other features.&lt;BR&gt;&lt;BR&gt;4¡¢ Technical parameters&lt;BR&gt;1. Current section&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;DIV align=center&gt;rated current ratio&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨A£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=106&gt;
&lt;DIV align=center&gt;Accurate level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;DIV align=center&gt;rated output&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨VA£©&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;Rated short-time thermal current (kA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;Rated dynamic stability current (kA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=125&gt;
&lt;DIV align=center&gt;Rated insulation level (kV)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;DIV align=center&gt;10-200/5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=106&gt;
&lt;DIV align=center&gt;0.2S&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;
&lt;DIV align=center&gt;0.5S&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;
&lt;DIV align=center&gt;0.2S/0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=94&gt;
&lt;DIV&gt;ten&lt;/DIV&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;
&lt;DIV align=center&gt;10/15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;100I1n&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;250I1n&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=125&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;DIV align=center&gt;300/5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;seventy-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;DIV align=center&gt;400-1000/5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=96&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;DIV align=center&gt;one hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;2. Voltage section&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=102&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV align=center&gt;Rated voltage ratio&lt;/DIV&gt;
&lt;DIV align=center&gt;(kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;Accurate level combination&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;DIV align=center&gt;rated output&lt;/DIV&gt;
&lt;DIV align=center&gt;(VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;DIV align=center&gt;Extreme output&lt;/DIV&gt;
&lt;DIV align=center&gt;(VA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Rated insulation level&lt;/DIV&gt;
&lt;DIV align=center&gt;£¨kV£©&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102&gt;
&lt;DIV align=center&gt;JLDZ-6R(G)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV align=center&gt;6/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=85&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=95&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=82&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;7.2/32/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=102&gt;
&lt;DIV align=center&gt;JLDZ-10R(G)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV align=center&gt;10/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=108&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=188&gt;
&lt;DIV align=center&gt;10/0.1/0.1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=85&gt;
&lt;DIV align=center&gt;0.2/0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;DIV align=center&gt;15/20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=82&gt;
&lt;DIV align=center&gt;two hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102&gt;
&lt;DIV align=center&gt;JLDZ-6R(G)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV&gt;6/¡Ì3/0.1/¡Ì3/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=85&gt;
&lt;DIV align=center&gt;0.2/6P&lt;/DIV&gt;
&lt;DIV align=center&gt;0.5/6P&lt;/DIV&gt;
&lt;DIV align=center&gt;1/6P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=95&gt;
&lt;DIV align=center&gt;20/50&lt;/DIV&gt;
&lt;DIV align=center&gt;50/50&lt;/DIV&gt;
&lt;DIV align=center&gt;90/50&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=82&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;7.2/32/60&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=102&gt;
&lt;DIV align=center&gt;JLDZ-10R(G)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=188&gt;
&lt;DIV&gt;10/¡Ì3/0.1/¡Ì3/0.1/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;12/42/75&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;5¡¢ Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201108/20110816091944241.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 516px; WIDTH: 640px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLDZ-10R series combination transformer appearance and installation dimensions&quot; src=&quot;/upload2011/201108/20110816091944241.jpg&quot; width=640 height=516&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110816091953734.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 366px; WIDTH: 426px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLDZ-10R series combination transformer external dimensions 1&quot; src=&quot;/upload2011/201108/20110816091953734.jpg&quot; width=426 height=366&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110816092003503.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 360px; WIDTH: 477px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLDZ-10R series combination transformer external dimensions 2&quot; src=&quot;/upload2011/201108/20110816092003503.jpg&quot; width=477 height=360&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110816092013940.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 346px; WIDTH: 448px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLDZ-10R series combination transformer external dimensions 3&quot; src=&quot;/upload2011/201108/20110816092013940.jpg&quot; width=448 height=346&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110816092022812.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 361px; WIDTH: 389px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLDZ-10R series combination transformer&quot; src=&quot;/upload2011/201108/20110816092022812.jpg&quot; width=389 height=361&gt;&lt;/A&gt;&lt;BR&gt;JLDZ-10R series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLS(J)8-10GYW1 series combination transformer </title>
           <link>http://www.91way.com/info_en/3178.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:09:16</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200853105149364.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1840px; WIDTH: 575px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JLS (J) 8-10GYW1 series combination transformer&quot; src=&quot;/uploadfiles/200805/200853105149364.jpg&quot; width=575 height=1840&gt;&lt;/A&gt;&lt;BR&gt;JLS (J) 8-10GYW1 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLS(J)7-10GYW1 series combination transformer </title>
           <link>http://www.91way.com/info_en/3177.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 19:09:08</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085310505452.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1623px; WIDTH: 560px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of JLS (J) 7-10GYW1 series combination transformer&quot; src=&quot;/uploadfiles/200805/20085310505452.jpg&quot; width=560 height=1623&gt;&lt;/A&gt;&lt;BR&gt;JLS (J) 7-10GYW1 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVR6-10 series combination transformer </title>
           <link>http://www.91way.com/info_en/2933.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:59:33</pubDate>
           <comments></comments>
           <description>JLSZVR6-10 series combination transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVK-3,6,10 series combination transformer </title>
           <link>http://www.91way.com/info_en/2932.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:59:25</pubDate>
           <comments></comments>
           <description>JLSZVK-3¡¢ 6. The 10 series combination transformer is an outdoor dry-type transformer suitable for measuring voltage, current, electrical energy, and power in AC 10kV, 50 (60) Hz power systems.&lt;BR&gt;JLSZVK-3¡¢ 6. The 10 series combination transformer adopts oil-free and maintenance free design, and has the advantages of high measurement accuracy, good insulation performance, anti-theft, and light weight.&lt;BR&gt;JLSZVK-3¡¢ 6. The 10 series combination transformer consists of a voltage transformer and a current transformer connected through V/V wiring to form a three-phase device.&lt;BR&gt;&lt;BR&gt;JLSZVK-3, Introduction to the Structure of 6,10 Series Combination Transformers&lt;BR&gt;1. The primary and secondary coils of the current transformer are in a chain structure, and the measuring grade iron core is made of ultrafine crystalline alloy. The secondary wires are uniformly wound on the iron core. The primary coil is made of high-quality soft copper strip or glass wire enameled wire.&lt;BR&gt;2. The iron core of the voltage transformer adopts a ring shape, with secondary winding and primary winding sleeved on the core column. The secondary winding is wound on an insulating cylinder, and the outermost layers of the first and last sections of the primary winding are equipped with electrostatic screens. Both windings are multi-layer cylindrical, with the primary winding wrapped around the secondary winding and insulation left between the windings.&lt;BR&gt;3. The current and voltage transformers are installed and fixed on the component board inside the box, which is connected to the cover plate and can be lifted out of the oil tank for maintenance.&lt;BR&gt;4. The secondary terminal is equipped with lead sealing screws to prevent electricity theft.&lt;BR&gt;3¡¢ Technical data (if you want to order product technical data beyond the following range, please consult with me to determine)&lt;BR&gt;1. The product performance complies with IEC standards and GB17201-1997 'Combination Transformer';&lt;BR&gt;2. Rated insulation level: 12/42/75kV;&lt;BR&gt;3. Rated frequency: 50/60Hz;&lt;BR&gt;4. Allow operation at 120% rated current and voltage;&lt;BR&gt;5. Load power factor: COS ¦Õ=0.8 (lag);&lt;BR&gt;6. Rated secondary current: 5A&lt;BR&gt;7. The rated output and dynamic thermal stability current can be found on the product nameplate.&lt;BR&gt;&lt;BR&gt;4¡¢ Scope of application (if you want to order a product, please consult with me to determine if the scope of application exceeds the following)&lt;BR&gt;1. Equipment type: outdoor;&lt;BR&gt;2. The altitude of the installation site shall not exceed 1000m;&lt;BR&gt;3. Environmental temperature: -40 ¡æ -+40 ¡æ;&lt;BR&gt;4. There is no serious pollution in the atmosphere that affects the insulation performance of transformers&lt;BR&gt;&lt;BR&gt;JLSZVK-3, 6,10 series combination transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSJV1-10 series oil immersed combination transformer </title>
           <link>http://www.91way.com/info_en/2931.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:59:16</pubDate>
           <comments></comments>
           <description>The JLSJV1-10 series oil immersed combination transformer is suitable for measuring voltage, current, electrical energy, and power in AC 10kV, 50 (60) Hz power systems.&lt;BR&gt;This product has the advantages of high measurement accuracy, good insulation performance, anti-theft, good leakage effect, and light weight. It is an ideal energy metering device for the current power supply system.&lt;BR&gt;This product consists of a three-phase device composed of voltage transformers and current transformers connected by V/V.&lt;BR&gt;&lt;BR&gt;Structure Introduction&lt;BR&gt;1. The current transformer adopts a secondary coil wound on an amorphous alloy iron core, cast and molded with epoxy resin. After the primary coil is wound through the core, it is fastened to the high-voltage ceramic through an insulation sheath.&lt;BR&gt;2. The high-voltage coil of the voltage transformer is wound on a reinforced nylon skeleton that is formed in one go, avoiding gap creepage, uniform electric field, low dielectric loss, high insulation resistance, and high withstand voltage strength, greatly improving the reliability of the product.&lt;BR&gt;3. The current and voltage transformers are installed and fixed on the component board inside the box, which is connected to the cover plate and can be lifted out of the oil tank for maintenance.&lt;BR&gt;4. The fuel tank is rectangular in shape, with an oil dipstick installed on the side of the tank. The tank contains transformer oil and adopts vacuum oil filtration and vacuum oil injection technology.&lt;BR&gt;5. The secondary terminal is equipped with lead sealing screws to prevent electricity theft.&lt;BR&gt;6. The box cover is equipped with a moisture absorber. Please install the moisture absorber when it is put into operation.&lt;BR&gt;&lt;BR&gt;Technical data (if you want to order product technical data beyond the following range, please consult with me to determine)&lt;BR&gt;&lt;BR&gt;1. The product performance complies with IEC standards and GB17201-1997 'Combination Transformer';&lt;BR&gt;2. Rated insulation level: 12/42/75kV;&lt;BR&gt;3. Rated frequency: 50/60Hz;&lt;BR&gt;4. Allow operation at 120% rated current and voltage;&lt;BR&gt;5. Load power factor: COS ¦Õ=0.8 (lag);&lt;BR&gt;6. Rated secondary current: 5A&lt;BR&gt;7. The rated output and dynamic thermal stability current can be found on the product nameplate.&lt;BR&gt;&lt;BR&gt;The applicable scope of JLSJV1-10 series oil immersed combination transformer (if you want to order a product with an applicable scope beyond the following range, please consult with me to determine)&lt;BR&gt;1. Equipment type: outdoor;&lt;BR&gt;2. The altitude of the installation site shall not exceed 1000m;&lt;BR&gt;3. Environmental temperature: -25 to+40 ¡æ;&lt;BR&gt;4. There is no pollution, corrosive or explosive medium in the atmosphere that seriously affects the insulation performance of transformers&lt;BR&gt;&lt;BR&gt;JLSJV1-10 series oil immersed combination transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVW1-10 series combination transformer </title>
           <link>http://www.91way.com/info_en/2930.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:59:07</pubDate>
           <comments></comments>
           <description>The JLSZVW1-10 combination transformer is a three-phase integral casting outdoor product. Suitable for measuring voltage, current, electrical energy, and power in AC 50-60Hz 10kV power systems where the neutral point is not directly grounded.&lt;BR&gt;The JLSZVW1-10 series combination transformer adopts single components and is composed of a three-phase device through V/V wiring.&lt;BR&gt;This series of products are fully enclosed, all working condition, and maintenance free products made by one-time casting of outdoor epoxy resin imported from Switzerland. Strong weather resistance and stain resistance, only need to regularly wipe the surface dust. The surface creepage distance is large, suitable for use in high temperature and high humidity areas.&lt;BR&gt;This series of products has strong short-circuit resistance and can withstand large dynamic and thermal stable currents. Considering the long distance from the substation metering point to the control room and the high secondary impedance, this series of products has increased the secondary capacity. And it can meet the requirements of the substation for oil-free transformers, high dynamic and thermal stability, large capacity, and complex transformation ratio.&lt;BR&gt;This series of products has strong anti electricity theft function. The secondary junction boxes of the transformers are all equipped with lead sealed screws to prevent unauthorized disassembly of the secondary junction boxes and electricity theft. The secondary side lead out requires the use of armored cables. In order to prevent electricity thieves from changing the nameplate and stealing electricity, the product has a current transformation ratio cast on the body of the current transformer at the factory, which is convenient for meter readers to verify.&lt;BR&gt;&lt;BR&gt;Structure Introduction&lt;BR&gt;1. The PT core of JLSZVW1-10 combination transformer adopts a ring type, with secondary winding and primary winding sleeved on the core column. The secondary winding is wound on an insulating cylinder, and the outermost layers of the first and last sections of the primary winding are equipped with electrostatic screens. Both windings are multi-layer cylindrical, with the primary winding wrapped around the secondary winding and insulation left between the windings.&lt;BR&gt;The primary and secondary coils of the current transformer are in a chain structure. The iron core is made of ultrafine crystalline alloy, and the secondary coil is uniformly wound on the iron core. The primary coil is made of high-quality soft copper strip or glass enameled wire.&lt;BR&gt;2. The casting body is fixed to the base bracket with bolts. The secondary junction box has an outlet at the bottom, and a nameplate is riveted on the junction box cover. There are four screw holes on the bracket for users to install and use. There is a dedicated grounding bolt on the bracket.&lt;BR&gt;&lt;BR&gt;Technical data (if you want to order product technical data beyond the following range, please consult with me to determine)&lt;BR&gt;1. The product performance complies with IEC standards and GB17201-1997 'Combination Transformer';&lt;BR&gt;2. Rated insulation level: 12/42/75kV;&lt;BR&gt;3. Rated frequency: 50/60Hz;&lt;BR&gt;4. Allow operation at 120% rated current and voltage;&lt;BR&gt;5. Load power factor: COS ¦Õ=0.8 (lag);&lt;BR&gt;6. Rated secondary current: 5A&lt;BR&gt;7. The rated output and dynamic thermal stability current can be found on the product nameplate.&lt;BR&gt;&lt;BR&gt;Scope of application (if you want to order a product, please consult with me to determine if the scope of application exceeds the following)&lt;BR&gt;1. Equipment type: outdoor;&lt;BR&gt;2. The altitude of the installation site shall not exceed 1000m;&lt;BR&gt;3. Environmental temperature: -40 to+40 ¡æ;&lt;BR&gt;4. There is no pollution, corrosive or explosive medium in the atmosphere that seriously affects the insulation performance of transformers. 
&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201104/20110404092448497.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 690px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZVW1-10 series combination transformer appearance and installation dimensions&quot; src=&quot;/upload2011/201104/20110404092448497.jpg&quot; width=680 height=690&gt;&lt;/A&gt;&lt;BR&gt;JLSZVW1-10 series combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZVW2-10 type combination transformer </title>
           <link>http://www.91way.com/info_en/2895.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:58:41</pubDate>
           <comments></comments>
           <description>The JLSZVW2-10 combination transformer is a three-phase integral casting outdoor product. Suitable for measuring voltage, current, electrical energy, and power in AC 50-60Hz 10kV power systems where the neutral point is not directly grounded.&lt;BR&gt;This series of products adopts single components and is composed of three-phase devices through V/V wiring.&lt;BR&gt;This series of products are fully enclosed, all working condition, and maintenance free products made by one-time casting of outdoor epoxy resin imported from Switzerland. Strong weather resistance and stain resistance, only need to regularly wipe the surface dust. The surface creepage distance is large, suitable for use in high temperature and high humidity areas.&lt;BR&gt;This series of products has strong short-circuit resistance and can withstand large dynamic and thermal stable currents. Considering the long distance from the substation metering point to the control room and the high secondary impedance, this series of products has increased the secondary capacity. And it can meet the requirements of the substation for oil-free transformers, high dynamic and thermal stability, large capacity, and complex transformation ratio.&lt;BR&gt;This series of products has strong anti electricity theft function. The secondary junction boxes of the transformers are all equipped with lead sealed screws to prevent unauthorized disassembly of the secondary junction boxes and electricity theft. The secondary side lead out requires the use of armored cables. In order to prevent electricity thieves from changing the nameplate and stealing electricity, the product has a current transformation ratio cast on the body of the current transformer at the factory, which is convenient for meter readers to verify.&lt;BR&gt;2¡¢ Structure Introduction&lt;BR&gt;1. The PT core of JLSZVW2-10 combination transformer adopts a ring type, with secondary winding and primary winding sleeved on the core column. The secondary winding is wound on an insulating cylinder, and the outermost layers of the first and last sections of the primary winding are equipped with electrostatic screens. Both windings are multi-layer cylindrical, with the primary winding wrapped around the secondary winding and insulation left between the windings.&lt;BR&gt;The primary and secondary coils of the current transformer are in a chain structure. The iron core is made of ultrafine crystalline alloy, and the secondary coil is uniformly wound on the iron core. The primary coil is made of high-quality soft copper strip or glass enameled wire.&lt;BR&gt;2. The casting body is fixed to the base bracket with bolts. The secondary junction box has an outlet at the bottom, and a nameplate is riveted on the junction box cover. There are four screw holes on the bracket for users to install and use. There is a dedicated grounding bolt on the bracket.&lt;BR&gt;3¡¢ Technical data (if you want to order product technical data beyond the following range, please consult with me to determine)&lt;BR&gt;1. The product performance complies with IEC standards and GB17201-1997 'Combination Transformer';&lt;BR&gt;2. Rated insulation level: 12/42/75kV;&lt;BR&gt;3. Rated frequency: 50/60Hz;&lt;BR&gt;4. Allow operation at 120% rated current and voltage;&lt;BR&gt;5. Load power factor: COS ¦Õ=0.8 (lag);&lt;BR&gt;6. Rated secondary current: 5A&lt;BR&gt;7. The rated output and dynamic thermal stability current can be found on the product nameplate.&lt;BR&gt;4¡¢ Scope of application (if you want to order a product, please consult with me to determine if the scope of application exceeds the following)&lt;BR&gt;1. Equipment type: outdoor;&lt;BR&gt;2. The altitude of the installation site shall not exceed 1000m;&lt;BR&gt;3. Environmental temperature: -40 to+40 ¡æ;&lt;BR&gt;4. There is no pollution, corrosive or explosive medium in the atmosphere that seriously affects the insulation performance of transformers.&lt;BR&gt;&lt;BR&gt;JLSZVW2-10 type combination transformer&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]LMZS1,2-0.66W series outdoor current combination transformer </title>
           <link>http://www.91way.com/info_en/1299.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:36:59</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;LMZS1,2-0.66W series outdoor current combination transformer&lt;BR&gt;&lt;BR&gt;Comparison table of transformer capacity and matched transformers (for reference only)&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061110121754732.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 240px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of LMZS1,2-0.66W series outdoor current combination transformer&quot; src=&quot;/uploadfiles/200611/20061110121754732.jpg&quot; width=680 height=240&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006111012189900.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 750px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;LMZS1,2-0.66W series outdoor current combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200611/2006111012189900.jpg&quot; width=680 height=750&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;LMZS1,2-0.66W series outdoor current combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZV series three-phase dry-type outdoor combination transformer </title>
           <link>http://www.91way.com/info_en/154.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:25:05</pubDate>
           <comments></comments>
           <description>JLSZV series three-phase dry-type outdoor combination transformer structure&lt;BR&gt;Rated insulation level: 12/42/75kV&lt;BR&gt;Minimum surface creepage distance&lt;BR&gt;The parameters of the current transformer are shown in the table (rated secondary current is 5A or 2A, 1A)&lt;BR&gt;Voltage transformer rated secondary voltage 100V, three-phase rated secondary output; Level 0.2: 3 &#215; 20&lt;BR&gt;Level 0.5: 30 &#215; 50 (VA) Maximum output: 3 &#215; 400 (VA)&lt;BR&gt;Class 0.2:3&#215;20(VA) Class 0.5:30&#215;50(VA) Output terminal :3&#215;400(VA)&lt;BR&gt;Rated primary current, secondary output, and rated dynamic and thermal stability current:&lt;BR&gt;&lt;BR&gt;Table 1 
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 381px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZV series three-phase dry-type outdoor combination transformer&quot; src=&quot;http://www.91way.com/uploadfiles/200610/20061020101858571.jpg&quot; width=680 height=381&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD height=&quot;30&quot;&gt;&lt;BR&gt;JLSZV series three-phase dry-type outdoor combination transformer appearance and installation dimensions&lt;/TD&gt;&lt;/TR&gt; 
&lt;P align=center&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 426px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZV series three-phase dry-type outdoor combination transformer appearance and installation dimensions&quot; src=&quot;http://www.91way.com/uploadfiles/200610/20061020101913172.jpg&quot; width=680 height=426&gt;&lt;BR&gt;&lt;BR&gt;JLSZV series three-phase dry-type outdoor combination transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZ¡õ Series Outdoor Dry type Combination Transformer </title>
           <link>http://www.91way.com/info_en/152.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:24:57</pubDate>
           <comments></comments>
           <description>Main performance of JLSZ ¡õ series outdoor dry-type combination transformer&lt;BR&gt;&lt;BR&gt;1. Rated voltage: divided into 3 &#215; 6kV, 3 &#215; 10kV, 3 &#215; 35kV&lt;BR&gt;2. Rated transformation ratio: Voltage ratio: 6000/100V, 10000/100V, 35000/100V.&lt;BR&gt;Current ratio: 1-1000/5A, and divided into single transformation ratio and dual transformation ratio.&lt;BR&gt;The primary wiring P1 and P2 of the dual ratio measuring box have a high current ratio.&lt;BR&gt;P1 and P3 are small current ratios.&lt;BR&gt;3. Rated capacity: PT components are divided into three types: 15, 25, and 50VA.&lt;BR&gt;CT components are divided into three types: 10, 25, and 30VA.&lt;BR&gt;4. Accuracy levels: 0.5, 0.2, 0.5S, 0.2S.&lt;BR&gt;&lt;BR&gt;Wiring diagram of JLSZ ¡õ series outdoor dry-type combination transformer 
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 460px; WIDTH: 465px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZ ¡õ series outdoor dry-type combination transformer&quot; src=&quot;/uploadfiles/200610/2006102010851260.jpg&quot; width=465 height=460&gt;&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 871px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZ ¡õ series outdoor dry-type combination transformer appearance and installation dimensions&quot; src=&quot;/uploadfiles/200610/2006102010912988.jpg&quot; width=680 height=871&gt;&lt;BR&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD&gt;&lt;IMG style=&quot;HEIGHT: 871px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JLSZ ¡õ series outdoor dry-type combination transformer external dimensions&quot; src=&quot;/uploadfiles/200610/2006102010107673.jpg&quot; width=680 height=871&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt; 
&lt;P align=center&gt;JLSZ ¡õ series outdoor dry-type combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Combination type transformer]JLSZW-10 outdoor dry-type combination transformer </title>
           <link>http://www.91way.com/info_en/151.html</link>
           <author></author>
           <guid></guid>
           <category>Combination type transformer</category>
           <pubDate>2026-6-13 18:24:48</pubDate>
           <comments></comments>
           <description>JLSZW-10 outdoor dry-type combination transformer&lt;STRONG&gt;&lt;BR&gt;&lt;/STRONG&gt;&lt;BR&gt;1. Rated voltage: 10kV&lt;BR&gt;2. Accuracy level: 0.5 and 0.2 levels, 0.5S and 0.2S levels; &amp;nbsp;&lt;BR&gt;&lt;BR&gt;&lt;TD&gt;&lt;IMG style=&quot;HEIGHT: 262px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Wiring diagram of JLSZW-10 outdoor dry-type combination transformer&quot; src=&quot;/uploadfiles/200610/200610201042858.jpg&quot; width=680 height=262&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD height=&quot;30&quot;&gt;Wiring diagram&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD&gt;&lt;IMG style=&quot;HEIGHT: 244px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline and installation dimensions of JLSZW-10 outdoor dry-type combination transformer&quot; src=&quot;/uploadfiles/200610/2006102010413575.jpg&quot; width=680 height=244&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD height=&quot;30&quot;&gt;Outline drawing of electric meter box&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD&gt;&lt;IMG style=&quot;HEIGHT: 246px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of JLSZW-10 outdoor dry-type combination transformer&quot; src=&quot;/uploadfiles/200610/2006102010436763.jpg&quot; width=680 height=246&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt; 
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;JLSZW-10 outdoor dry-type combination transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
