       <item>
           <title>[Reclosing relay]DH-4 type reclosing relay </title>
           <link>http://www.91way.com/info_en/4371.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 19:26:50</pubDate>
           <comments></comments>
           <description>1. Overview:&lt;BR&gt;DH-4 type reclosing relay is used as the main component in the three-phase primary reclosing connection of transmission lines. Electromagnetic type. Composed of DS-22 time relay, ZJ3 intermediate relay, and RC device.&lt;BR&gt;&lt;BR&gt;2. Model parameters:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR height=30&gt;
&lt;TD width=137&gt;
&lt;DIV align=center&gt;Rated voltage DC (V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=223&gt;
&lt;DIV align=center&gt;Rated holding current of intermediate components DC (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=166&gt;
&lt;DIV align=center&gt;Time element setting range (s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=170&gt;
&lt;DIV align=center&gt;Preparation time for reclosing (S)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=50 width=&quot;None&quot;&gt;
&lt;TD width=137&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;BR&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=223&gt;
&lt;DIV align=center&gt;0.25,0.5&lt;BR&gt;1, 2,2.5&lt;BR&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=166&gt;
&lt;DIV align=center&gt;1.2-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=170&gt;
&lt;DIV align=center&gt;15-25 at rated voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;3. DH-4 type reclosing relay wiring diagram:&lt;BR&gt;&lt;BR&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;HEIGHT: 438px; WIDTH: 268px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DH-4 type reclosing relay wiring diagram&quot; src=&quot;/uploadfiles/200808/2008824115451421.gif&quot; width=268 height=438&gt;&lt;/P&gt;
&lt;P align=center&gt;DH-4 type reclosing relay&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]DH-3 type primary reclosing device </title>
           <link>http://www.91way.com/info_en/2510.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:51:23</pubDate>
           <comments></comments>
           <description>1. Application scope&lt;BR&gt;The DH-3 type primary reclosing device is used as the main component in the three-phase primary reclosing connection of transmission lines. It is composed of time element DS-22, intermediate element ZJ, capacitor C, resistor R, signal light, etc.&lt;BR&gt;&lt;BR&gt;2. Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;DC rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;Intermediate component retention&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Time element&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Prepare for the next action&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;(V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Holding current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Rated range (s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;Time (S)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;110, 220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.25, 0.5, 1, 2.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1. 2-5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;15-25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;3. Internal wiring&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200709/2007925192140921.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 219px; WIDTH: 325px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Contact diagram of DH-3 type primary reclosing device&quot; src=&quot;/uploadfiles/200709/2007925192140921.jpg&quot; width=325 height=219&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;4. Appearance and opening size&lt;BR&gt;The relay adopts JK-3 housing, with external dimensions and installation hole diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200709/200792519224572.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 483px; WIDTH: 582px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of DH-3 type primary reclosing device&quot; src=&quot;/uploadfiles/200709/200792519224572.jpg&quot; width=582 height=483&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DH-3 type primary reclosing device&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]DH-2A type primary reclosing device </title>
           <link>http://www.91way.com/info_en/2509.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:51:15</pubDate>
           <comments></comments>
           <description>1. Application scope&lt;BR&gt;Used as a reclosing element in the three-phase primary reclosing connection of transmission lines&lt;BR&gt;&lt;BR&gt;2. Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;DC rated voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;Intermediate component retention&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Preparation time for reclosing&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;Time element&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;Time element current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;36%&quot;&gt;
&lt;DIV align=center&gt;Contact connection current&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Un(V)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Under Un (s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;70% Un (min)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Delay range (s)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Winding power consumption (W)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.25, 0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;15-25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;0.25-3.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;≒1.35&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;After connecting the contacts of the intermediate components in series, the current should be ≡ 8A for 5 seconds&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;3. Internal wiring&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200709/2007925191741831.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 161px; WIDTH: 325px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Contact diagram of DH-2A type primary reclosing device&quot; src=&quot;/uploadfiles/200709/2007925191741831.jpg&quot; width=325 height=161&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;4. Appearance and opening size&lt;BR&gt;The relay adopts a protruding fixed wiring housing, with external dimensions and installation opening diagram.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200709/200792519182124.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 425px; WIDTH: 582px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of DH-2A type primary reclosing device&quot; src=&quot;/uploadfiles/200709/200792519182124.jpg&quot; width=582 height=425&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DH-2A type primary reclosing device&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]JH-3R Recloser relay </title>
           <link>http://www.91way.com/info_en/1532.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:41:45</pubDate>
           <comments></comments>
           <description>JH-3R reclosing relay&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]YCHJ-1 type with remote control reclosing relay </title>
           <link>http://www.91way.com/info_en/1531.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:41:36</pubDate>
           <comments></comments>
           <description>YCHJ-1 type with remote control reclosing relay&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]JH series static reclosing relay </title>
           <link>http://www.91way.com/info_en/1501.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:40:09</pubDate>
           <comments></comments>
           <description>1. Purpose:&lt;BR&gt;JH series static reclosing relay is used as the main component in the three-phase primary reclosing connection of transmission lines&lt;BR&gt;&lt;BR&gt;2. Characteristics&lt;BR&gt;2.1 The DH series reclosing relay can be replaced without changing the wiring of the relay screen, as shown in Table 1;&lt;BR&gt;2.2 Use a digital switch to set the reclosing delay time, with small scale error and high accuracy. Changing the setting value does not require recalibration;&lt;BR&gt;2.3 Preparation time for reclosing, constant at 20 seconds, unaffected by external voltage and ambient temperature;&lt;BR&gt;2.4 External startup reclosing, using optocoupler isolation. Good anti-interference performance.&lt;BR&gt;&lt;BR&gt;3. Main technical data&lt;BR&gt;3.1 DC rated voltage: 48V, 110V, 220V;&lt;BR&gt;3.2 DC rated holding current of intermediate relay current coil: 0.25A, 0.5A, 1A, 2.5A;&lt;BR&gt;3.3 The setting range of the time relay is 0.1S to 9.9S, with a step difference of 0.1s;&lt;BR&gt;3.4 Power consumption&lt;BR&gt;3.4.1 The power consumption of intermediate relays shall not exceed 8W for voltage coils at rated voltages of 110V and 220V, and 4W for current coils at rated current.&lt;BR&gt;3.4.2 Except for intermediate relays, the total power consumption of reclosing relays shall not exceed 5W at 220V rated voltage and 3W at 110V rated voltage.&lt;BR&gt;&lt;BR&gt;Table 1 Replacement Product Model Comparison Table:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=2 width=550 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR vAlign=middle&gt;
&lt;TD height=2 width=&quot;32%&quot;&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=&quot;68%&quot;&gt;
&lt;P align=center&gt;Equivalent replacement product model&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR vAlign=middle&gt;
&lt;TD height=2 width=&quot;32%&quot;&gt;
&lt;P align=center&gt;JH-1&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=&quot;68%&quot;&gt;
&lt;P align=center&gt;DH-1﹜DH-2A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR vAlign=middle&gt;
&lt;TD height=2 width=&quot;32%&quot;&gt;
&lt;P align=center&gt;JH-2&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=&quot;68%&quot;&gt;
&lt;P align=center&gt;DCH-1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR vAlign=middle&gt;
&lt;TD height=2 width=&quot;32%&quot;&gt;
&lt;P align=center&gt;JH-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=&quot;68%&quot;&gt;
&lt;P align=center&gt;DH-3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR vAlign=middle&gt;
&lt;TD height=2 width=&quot;32%&quot;&gt;
&lt;P align=center&gt;JH-4&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=2 width=&quot;68%&quot;&gt;
&lt;P align=center&gt;DH-4&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;JH series static reclosing relay&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]DH-1 type primary reclosing relay </title>
           <link>http://www.91way.com/info_en/1016.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:34:10</pubDate>
           <comments></comments>
           <description>1 Purpose&lt;BR&gt;Used in the control circuit for implementing three-phase primary reclosing on transmission lines.&lt;BR&gt;&lt;BR&gt;Overview of Structure 2&lt;BR&gt;This relay consists of a time relay (DS-112C type, as the time element JS), an electrical code relay (as the intermediate element JZ), and resistance and capacitance elements. They are fixed on an insulated mounting plate, which in turn is fixed on a metal base. The mounting plate is equipped with a metal shell, which is fastened to the base by screws. A dust isolation pad is attached between the shell and the base to ensure sealing. Glass is embedded on the upper part of the metal shell, allowing for inspection of the device's operation from the outside.&lt;BR&gt;Relays can be wired before or after the board.&lt;BR&gt;Internal wiring diagram of relay, Figure 1.&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 253px; WIDTH: 297px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DH-1 type primary reclosing relay wiring diagram&quot; src=&quot;/uploadfiles/200611/2006114102930851.gif&quot; width=297 height=253&gt;&lt;BR&gt;&lt;BR&gt;Figure 1 Internal wiring diagram of DH-1 relay (back view)&lt;BR&gt;&lt;BR&gt;3 Technical data&lt;BR&gt;3.1 The rated voltage of the relay is DCll0V, 220V.&lt;BR&gt;3.2 The rated current of the relay (rated holding current of the intermediate component current winding JZ (1)) is 0.25A; 0.5A; 1A˙2A˙ 4A﹝&lt;BR&gt;3.3 At rated voltage, when the ambient temperature is 20 &#177; 5 ⊥ and the relative humidity is not greater than 70%, the time for the capacitor to charge to the necessary voltage for the intermediate component (the interval time for one reclosing) is within the range of 15s-25s.&lt;BR&gt;3.4 At 70% rated voltage, when the ambient temperature is 20 &#177; 5 ⊥ and the relative humidity is not greater than 70%, the relay should ensure reliable operation. At this time, the time for the capacitor to charge to the voltage necessary for the intermediate components to operate can be extended to 2 minutes.&lt;BR&gt;When there is no voltage in the intermediate component voltage winding and the current winding flows through the rated current, the armature remains in the engaged position.&lt;BR&gt;After the intermediate component contacts JZl and JZ (I) of the relay are connected in series at rated voltage, it should be ensured that a current of 8 times the rated current (not greater than 8A) can be connected for 5 seconds, and there should be no traces of melting or adhesion on the contacts thereafter.&lt;BR&gt;At rated voltage, the power consumption of the intermediate component current winding JZ (1) should not exceed 1.35W.&lt;BR&gt;The delay adjustment range of the 3.8 time element is 0.25s to 3.5s.&lt;BR&gt;The coil of the time element connected in series with an additional resistor should be able to withstand 110% of the rated voltage for a long time.&lt;BR&gt;3.10 Dielectric strength: Each circuit of the relay should withstand a voltage of 2kV between the exposed non charged metal parts, and conduct an AC 50Hz test for 1 minute without breakdown or flashover.&lt;BR&gt;The weight of the 3.11 device shall not exceed 5kg.&lt;BR&gt;3.12 The external dimensions and opening dimensions are shown in Figure 2 and Figure 3.&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 288px; WIDTH: 503px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DH-1 type primary reclosing relay installation size 1&quot; src=&quot;/uploadfiles/200611/2006114102923449.gif&quot; width=503 height=288&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 247px; WIDTH: 472px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DH-1 type primary reclosing relay installation size 2&quot; src=&quot;/uploadfiles/200611/2006114102913850.gif&quot; width=472 height=247&gt;&lt;BR&gt;Figure 2: Dimensions of DH-1 Relay&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 203px; WIDTH: 231px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Hole size of DH-1 type primary reclosing relay&quot; src=&quot;/uploadfiles/200611/200611410291720.gif&quot; width=231 height=203&gt;&lt;BR&gt;Figure 3: Hole size of DH-1 relay&lt;BR&gt;&lt;BR&gt;The parameters of each component inside the 3.13 relay are given in Table 1.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=27 rowSpan=2 width=&quot;8%&quot;&gt;
&lt;P align=center&gt;wiring diagram&lt;/P&gt;
&lt;P align=center&gt;code name&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 rowSpan=2 width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;name&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 width=&quot;71%&quot; colSpan=2&gt;
&lt;P align=center&gt;Rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=27 rowSpan=2 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;remark&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=29 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;110V&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=29 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;220V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 rowSpan=5 width=&quot;8%&quot;&gt;
&lt;P align=center&gt;ZJ(1)&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;ZJ(V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 rowSpan=5 width=&quot;4%&quot;&gt;
&lt;P align=center&gt;middle&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;interval&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;yuan&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;document&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 rowSpan=5 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;Forehead&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;fixed&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;electricity&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;flow&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;(A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;zero point two five&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=1200 turns W2=8000 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.35ㄛR=12.3次朴=0.12ㄛR=900次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=1200 turns W2=12600 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.35ㄛR=12.3次朴=0.1ㄛR=2100次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 rowSpan=5 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;W1 is&lt;/P&gt;
&lt;P align=center&gt;JZ(1)&lt;/P&gt;
&lt;P align=center&gt;The number of turns&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;W2 is&lt;/P&gt;
&lt;P align=center&gt;Jz(V)&lt;/P&gt;
&lt;P align=center&gt;The number of turns&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=600 turns W2=8000 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.49ㄛR=3.2次 朴=0.12ㄛR=900次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=600 turns W2=12600 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.49ㄛR=3.2次朴=0.1ㄛR=2100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=57 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=300 turns W2=8000 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.69ㄛR=0ㄝ8次朴=0.12ㄛR=900次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=57 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=300 turns W2=12600 turns&lt;/P&gt;
&lt;P align=center&gt;朴=0.69ㄛR=0ㄝ8次朴=0.1ㄛR=2100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=59 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;two point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=300 turns W2=8000 turns&lt;/P&gt;
&lt;P align=center&gt;朴=1ㄛR=0.2次 朴=0.12ㄛR=900次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=59 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;Wl=120 turns W2=12600 turns&lt;/P&gt;
&lt;P align=center&gt;朴=1ㄛR=0.2次 朴=0ㄝ1ㄛR=2100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=56 width=&quot;5%&quot;&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=56 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;W1=75 turns W2=8000 turns&lt;/P&gt;
&lt;P align=center&gt;朴=1.32ㄛR=0.05次朴=0.12ㄛR=900次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=56 width=&quot;35%&quot;&gt;
&lt;P align=center&gt;W1=75 turns W2=12600 turns&lt;/P&gt;
&lt;P align=center&gt;朴=1.32ㄛR=0.05次朴=0.1ㄛR=2100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=173 width=&quot;8%&quot;&gt;
&lt;P align=center&gt;JS&lt;/P&gt;
&lt;P align=center&gt;C&lt;/P&gt;
&lt;P align=center&gt;4R&lt;/P&gt;
&lt;P align=center&gt;5R&lt;/P&gt;
&lt;P align=center&gt;6R&lt;/P&gt;
&lt;P align=center&gt;17R&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=173 width=&quot;14%&quot; colSpan=3&gt;
&lt;P align=center&gt;Time element&lt;/P&gt;
&lt;P align=center&gt;capacitor&lt;/P&gt;
&lt;P align=center&gt;resistor&lt;/P&gt;
&lt;P align=center&gt;resistor&lt;/P&gt;
&lt;P align=center&gt;resistor&lt;/P&gt;
&lt;P align=center&gt;resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=173 width=&quot;35%&quot;&gt;
&lt;P align=justify&gt;W=9800 turns, 朴=0.2, R=450 次&lt;/P&gt;
&lt;P align=justify&gt;CZM〞L〞250-10uf&lt;/P&gt;
&lt;P align=justify&gt;RT-0.5〞2.2M次&lt;/P&gt;
&lt;P align=justify&gt;RXY-20〞1K次&lt;/P&gt;
&lt;P align=justify&gt;RXY-15〞500次&lt;/P&gt;
&lt;P align=justify&gt;RXY〞20-1K次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=173 width=&quot;35%&quot;&gt;
&lt;P align=justify&gt;W=17600 turns, 朴=0.13, R=1930 次&lt;/P&gt;
&lt;P align=justify&gt;CZM〞L-630〞4uf&lt;/P&gt;
&lt;P align=justify&gt;RT-0.5-6.8M次&lt;/P&gt;
&lt;P align=justify&gt;RXY-20〞4K次&lt;/P&gt;
&lt;P align=justify&gt;RXY-15-500次&lt;/P&gt;
&lt;P align=justify&gt;RXY-20-3K次&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=173 width=&quot;7%&quot;&gt;
&lt;P align=center&gt;two&lt;/P&gt;
&lt;P align=center&gt;parallel connection&lt;/P&gt;
&lt;P align=center&gt;two&lt;/P&gt;
&lt;P align=center&gt;parallel connection&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=7 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=35 width=&quot;38%&quot;&gt;
&lt;P align=center&gt;Rated current of circuit breaker closing contactor coil (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;0.3-0.6&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;0.6-1.2&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;1.2-3&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;3-7.5&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=35 width=&quot;38%&quot;&gt;
&lt;P align=center&gt;Rated current of relay (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;zero point two five&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=35 width=&quot;15%&quot;&gt;
&lt;P align=center&gt;two point five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;4 Ordering Instructions&lt;BR&gt;Please indicate when placing an order&lt;BR&gt;4.1 Name and model of relay.&lt;BR&gt;4.2 The rated voltage of the operating circuit and the rated current of the intermediate component current winding JZ (I).&lt;BR&gt;4.3 Wiring method (front or back).&lt;BR&gt;When selecting the specifications for the device, the rated current of the intermediate component current winding JZ (I) should be less than the rated current of the circuit breaker closing contactor coil. Specific options can be selected according to Table 2.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]JCH-2 series static reclosing relay </title>
           <link>http://www.91way.com/info_en/1004.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:33:43</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;The JCH-2 series static reclosing relay is used in transmission lines to cooperate with relay protection devices to achieve three-phase primary reclosing.&lt;BR&gt;Features:&lt;BR&gt;2.1 Static relays composed of digital integrated circuits.&lt;BR&gt;2.2 Adopting a crystal oscillation time loop, the delay action time error is small and the consistency is good.&lt;BR&gt;2.3 The preparation time for a reclosing is not determined by the conventional capacitor charging circuit, but by a pulse timing circuit. Therefore, the preparation time for the action is constant at 20 seconds (internally adjustable to 10 seconds, 20 seconds, 24 seconds, and adjusted to 20 seconds when the product leaves the factory), which is not affected by voltage changes and environmental temperature, improving the reliability of the action.&lt;BR&gt;2.4 The outlet relay adopts a small charged current self holding type, without using mechanical time mechanism and large volume charging capacitors and resistors, so the relay has a small volume and light weight.&lt;BR&gt;&lt;BR&gt;JCH-2 series static reclosing relay model name:&lt;BR&gt;Relays are equivalent to replacing old products. The model comparison table is shown in Table 1&lt;BR&gt;Note: If the export relay uses a large capacity intermediate relay, please specify it when ordering.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/20061132283764.bmp&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 358px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-2 series static reclosing relay model description&quot; src=&quot;/uploadfiles/200611/20061132283764.bmp&quot; width=680 height=358&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Working Principle:&lt;BR&gt;The schematic diagram is shown in Figure 1:&lt;BR&gt;The relay adopts imported CMOS digital and logic integrated circuits. When the relay is connected to the DC power supply, a pulse forming circuit starts timing. After 20 seconds, the preparation light is on, and the reclosing preparation is completed, allowing reclosing. If the transmission line is in normal condition, the relay remains in the above prepared action state. When a fault occurs in the transmission line and the circuit breaker trips, the reclosing will be initiated. After a delay setting, the driving output relay will be triggered, and its current holding circuit will be maintained until the circuit breaker is closed. At the same time, a pulse forms a circuit reset. If the transmission line is experiencing a temporary fault, after the circuit breaker is successfully closed, a pulse will form a circuit to re time and the relay will be in a ready to operate state again. If there is a permanent fault in the transmission line, the reclosing will not be successful and the circuit breaker will trip for the second time. However, this period of time is much shorter than the 20 second countdown time for a pulse to form a circuit, so the relay is guaranteed not to operate.&lt;BR&gt;The relay can be externally locked through the locking terminal to prevent reclosing, and the relay preparation light will not light up at this time.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/200611322843386.bmp&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 246px; WIDTH: 547px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-2 series static reclosing relay schematic&quot; src=&quot;/uploadfiles/200611/200611322843386.bmp&quot; width=547 height=246&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Usage:&lt;BR&gt;6.1 After the relay is connected to the DC power supply for 20 seconds, the indicator light is ready to light up and the relay is in normal working condition.&lt;BR&gt;6.2 The delay setting of the reclosing action adopts a two digit 8421 code digital dial switch, and the formula for time setting is t=0.1 &#215; MN (s).&lt;BR&gt;There are two sets of two digit switches on the JCH-2C type reclosing relay panel. The upper set of digital switches sets the reclosing delay time (J3), and the lower set of digital switches sets the J relay delay time (J2, J4). The time setting formula is t=0.1 &#215; MN (s).&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;8.1 DC rated voltage: 48V, 110V, 220V.&lt;BR&gt;8.2 Closing current: 0.5A, 1A, 2A, 5A.&lt;BR&gt;8.3 Delay range: 0.1-9.9s, with a difference of 0.1s.&lt;BR&gt;The interval time for one reclosing is 20s &#177; 0.05s.&lt;BR&gt;8.5 Under rated conditions, at any point within the delay range, the absolute value of delay error shall not exceed (0.1%+10ms), and the absolute value of delay consistency shall not exceed (0.1%+10ms).&lt;BR&gt;8.6 Power consumption shall not exceed 5W.&lt;BR&gt;8.7 Dielectric Strength&lt;BR&gt;The circuits of the relay and the exposed non-conductive metal and shell should be able to withstand an effective value of 2Kv, 50Hz AC voltage for 1 minute, and there should be no insulation breakdown or flashover phenomenon.&lt;BR&gt;8.8 Contact breaking capacity&lt;BR&gt;Under the conditions of current not exceeding 2A and voltage not exceeding 250V, the external output contact can disconnect a DC inductive load of 50W with a time constant of 5ms &#177; 0.75ms.&lt;BR&gt;8.9 Working conditions&lt;BR&gt;a) The usage location does not allow explosive media, and the surrounding media should not contain corrosive metals, gases that damage insulation, or conductive media. It is not allowed to be filled with water vapor or have serious mold presence;&lt;BR&gt;b) Strong vibrations and impacts are not allowed in the usage location;&lt;BR&gt;c) The usage location should have facilities to defend against rain, snow, wind, and sand;&lt;BR&gt;d) The usage location does not allow an external magnetic induction intensity exceeding 1.5mT.&lt;BR&gt;8.10 Electrical anti-interference relays shall comply with GB7261 and GB6261 &quot;Electrical anti-interference tests for static relays and protective devices&quot;.&lt;BR&gt;&lt;BR&gt;JCH-2 series static reclosing relay back wiring diagram:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006113221016199.bmp&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 444px; WIDTH: 235px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-2 series static reclosing relay contact diagram&quot; src=&quot;/uploadfiles/200611/2006113221016199.bmp&quot; width=235 height=444&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Relay external dimensions and opening dimensions:&lt;BR&gt;The JCH-2A relay adopts an upward protruding fixed structure, and its external dimensions and installation hole dimensions are shown in Appendix Figure 1;&lt;BR&gt;The JCH-2B relay adopts an A-Ji protruding plug-in structure (code JK-3), and its external dimensions and installation hole dimensions are shown in Appendix Figure 2;&lt;BR&gt;The JCH-2C relay adopts an A-Ji protruding plug-in structure (code JK-3), and its external dimensions and installation hole dimensions are shown in Appendix Figure 2;&lt;BR&gt;The JCH-2D relay adopts the Xuji embedded plug-in structure (code A32K), and its external dimensions and installation hole dimensions are shown in Appendix Figure 3.&lt;BR&gt;&lt;BR&gt;Ordering instructions:&lt;BR&gt;9.1 Product model and name;&lt;BR&gt;9.2 Rated voltage and closing current;&lt;BR&gt;9.3 Order quantity;&lt;BR&gt;9.4 If there are special requirements, please specify.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Reclosing relay]JCH-1A type reclosing relay </title>
           <link>http://www.91way.com/info_en/918.html</link>
           <author></author>
           <guid></guid>
           <category>Reclosing relay</category>
           <pubDate>2026-6-13 18:31:30</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;JCH-1A reclosing relay is used for automatic reclosing in transmission lines. If the fault is temporary, it can be restored to operation. If the fault is permanent, it will trip again after overlapping.&lt;BR&gt;&lt;BR&gt;Relay model name:&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006111195849221.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 100px; WIDTH: 187px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-1A type reclosing relay model description&quot; src=&quot;/uploadfiles/200611/2006111195849221.gif&quot; width=187 height=100&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Working Principle:&lt;BR&gt;Relays are composed of electronic components such as transistors, voltage regulators, operational amplifiers, resistors, capacitors, and intermediate relays. All components are installed on a printed circuit board. There are time setting dial switches and DIP switches installed on the nameplate of the relay.&lt;BR&gt;Relays are composed of integrated circuits and electronic components. The delay time setting circuit adopts the linear integral timing principle, and the preparation time for one closing circuit adopts the RC charging timing principle. The principle diagram is shown in Figure 1.&lt;BR&gt;The delay setting circuit adopts two 8421 code digital dial switches and DIP switches for setting. The K1 dial switch time is set to (1-9) seconds, and the K2 dial switch time is set to (0.1-0.9) seconds. The formula for time setting is t=tn * (1+M.N)+10ms. Tn is the data of DIP switch, MN is the data of K1 and K2, as shown in Figure 2.&lt;BR&gt;After the relay is powered on, the RC in the closing circuit starts charging. After (17-25) seconds, the preparation light comes on and the relay is in the preparation closing state. After the delay setting of the closing start signal, a closing circuit is triggered, the outlet relay is activated, and self-protection is carried out by the current coil.&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/200611119594608.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 387px; WIDTH: 300px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-1A type reclosing relay schematic&quot; src=&quot;/uploadfiles/200611/200611119594608.gif&quot; width=300 height=387&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Main technical parameters:&lt;BR&gt;6.1 Rated voltage: DC 110V, 220V.&lt;BR&gt;6.2 Closing current: 0.5A, 1A, 2A, 4A.&lt;BR&gt;6.3 Delay range: 0.11s-17.45s, with a grading difference of 0.1s.&lt;BR&gt;6.4 Relay delay setting value with a delay consistency of less than 1 second shall have an absolute value of no more than 20ms. The relative value of delay consistency with a delay consistency of no less than 1 second shall not exceed 1%.&lt;BR&gt;6.5 The minimum holding current is 50% of the rated value.&lt;BR&gt;6.6 The interval between one reclosing is between 17-25 seconds.&lt;BR&gt;6.7 Closing pulse width 200ms (positive and negative deviation 20ms).&lt;BR&gt;6.8 The relay can start the reclosing time setting circuit for positive and negative power sources (determined by user requirements) and lock the reclosing circuit for negative power sources. The delay setting circuit adopts two 8421 code digital dial switches and DIP switches for setting. The K1 dial switch time is set to (1-9) seconds, and the K2 dial switch time is set to (0.1-0.9) seconds. The formula for time setting is t=tn * (1+M.N)+10ms. Tn is the data of DIP switch, MN is the data of K1 and K2, as shown in Figure 2.&lt;BR&gt;6.9 Power consumption&lt;BR&gt;See figure&lt;BR&gt;The dynamic contact of the 6.10 electric life relay should be able to disconnect no more than 250V and no more than 1A, and the contact should reliably operate no less than 1000 times in a DC circuit with a capacity of 30W and an inductive load (time constant 5ms &#177; 0.75ms). The long-term allowable current for connection is 2A, and the allowable time for the current self-protection circuit at rated current is 10s.&lt;BR&gt;6.11 The following parts of the dielectric strength relay should be able to withstand an effective value of the AC voltage specified in the table below, with a frequency of 50Hz, for 1 minute without breakdown or flashover.&lt;BR&gt;6.12 The anti-interference performance complies with the provisions of ZBK-33004 &quot;General Technical Conditions for Automatic Electrical Appliances and Devices for Power System Protection&quot;.&lt;BR&gt;&lt;BR&gt;JCH-1A type reclosing relay back wiring diagram:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200611/2006111195919940.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 115px; WIDTH: 118px; FILTER: none&quot; border=0 hspace=0 alt=&quot;JCH-1A type reclosing relay wiring diagram&quot; src=&quot;/uploadfiles/200611/2006111195919940.gif&quot; width=118 height=115&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;JCH-1A type reclosing relay external dimensions and opening dimensions:&lt;BR&gt;&lt;BR&gt;Refer to Figures 2 and 6 in the protruding modular insertion structure.&lt;BR&gt;&lt;BR&gt;Ordering instructions:&lt;BR&gt;8.1 Indicate the model, rated voltage, and closing current of the relay.&lt;BR&gt;8.2 Polarity of starting voltage (starting from positive or negative power supply).&lt;BR&gt;</description>
       </item>