           <title>[dual power switch]CAP2 series automatic transfer switch electrical appliances </title>
           <link>http://www.91way.com/info_en/26191.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:39:17</pubDate>
           <comments></comments>
           <description>The CAP2 series automatic transfer switch device (hereinafter referred to as the device) is a PC grade three-stage automatic transfer switch device, mainly used for switching between two neutral grounded power supply systems (common power supply and backup power supply or common power supply and power generation power supply) with AC 50Hz, rated voltage of 400V and below, and rated working current up to 1600A due to an abnormality in one power supply, ensuring the reliability and safety of its power supply.&lt;BR&gt;The device has three working positions: &quot;common power supply&quot;, &quot;disconnection position&quot;, and &quot;backup power supply&quot;, with high connection and disconnection capabilities. It can meet the conversion of conventional loads, as well as high inductance or large motor loads. At the same time, due to its high short-term withstand current capability, it does not require specific SCPD, does not affect the selectivity in the circuit, and can also meet the application on the large capacity power supply side.&lt;BR&gt;&lt;BR&gt;Complies with the standard GB/T14048.11.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center x:str=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Shell code&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD width=235 colSpan=5&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD width=235 colSpan=5&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD width=282 colSpan=6&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR height=61&gt;
&lt;TD height=61 width=176 colSpan=2&gt;model&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-32&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-40&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-50&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-63&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-80&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-100&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-125&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-140&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-160&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-200&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-225&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-250&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-315&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-350&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-400&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-500&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-630&lt;/TD&gt;
&lt;TD width=47&gt;CAP2-400b&lt;/TD&gt;
&lt;TD width=47&gt;CAP2-630b&lt;/TD&gt;
&lt;TD width=47&gt;CAP2&lt;BR&gt;-800&lt;/TD&gt;
&lt;TD width=47&gt;CAP2-1000&lt;/TD&gt;
&lt;TD width=47&gt;CAP2-1250&lt;/TD&gt;
&lt;TD width=47&gt;CAP2-1600&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated working current I&lt;SUB&gt;e&lt;/SUB&gt;£¨A£©&lt;/TD&gt;
&lt;TD width=47&gt;thirty-two&lt;/TD&gt;
&lt;TD width=47&gt;forty&lt;/TD&gt;
&lt;TD width=47&gt;fifty&lt;/TD&gt;
&lt;TD width=47&gt;sixty-three&lt;/TD&gt;
&lt;TD width=47&gt;eighty&lt;/TD&gt;
&lt;TD width=47&gt;one hundred&lt;/TD&gt;
&lt;TD width=47&gt;one hundred and twenty-five&lt;/TD&gt;
&lt;TD align=right&gt;one hundred and forty&lt;/TD&gt;
&lt;TD align=right&gt;one hundred and sixty&lt;/TD&gt;
&lt;TD align=right&gt;two hundred&lt;/TD&gt;
&lt;TD align=right&gt;two hundred and twenty-five&lt;/TD&gt;
&lt;TD align=right&gt;two hundred and fifty&lt;/TD&gt;
&lt;TD align=right&gt;three hundred and fifteen&lt;/TD&gt;
&lt;TD align=right&gt;three hundred and fifty&lt;/TD&gt;
&lt;TD align=right&gt;four hundred&lt;/TD&gt;
&lt;TD align=right&gt;five hundred&lt;/TD&gt;
&lt;TD align=right&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD align=right&gt;four hundred&lt;/TD&gt;
&lt;TD align=right&gt;six hundred and thirty&lt;/TD&gt;
&lt;TD align=right&gt;eight hundred&lt;/TD&gt;
&lt;TD align=right&gt;one thousand&lt;/TD&gt;
&lt;TD align=right&gt;one thousand two hundred and fifty&lt;/TD&gt;
&lt;TD align=right&gt;one thousand and six hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated working voltage U&lt;SUB&gt;e&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=1081 colSpan=23&gt;400/50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated insulation voltage U&lt;SUB&gt;i&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=799 colSpan=17&gt;eight hundred&lt;/TD&gt;
&lt;TD width=282 colSpan=6&gt;one thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;£¨kV£©&lt;/TD&gt;
&lt;TD width=799 colSpan=17&gt;eight&lt;/TD&gt;
&lt;TD width=282 colSpan=6&gt;twelve&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;polar number&lt;/TD&gt;
&lt;TD width=1081 colSpan=23&gt;3. 4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Usage category&lt;/TD&gt;
&lt;TD width=1081 colSpan=23&gt;AC-33B£¨10I&lt;SUB&gt;e&lt;/SUB&gt;Connect/10I&lt;SUB&gt;e&lt;/SUB&gt;Cut off)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=104 rowSpan=4 width=176 colSpan=2&gt;Rated short-time withstand current I&lt;SUB&gt;cw&lt;/SUB&gt;£¨kA/s£©&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;10/0.2&lt;/TD&gt;
&lt;TD colSpan=5&gt;10/0.5&lt;/TD&gt;
&lt;TD colSpan=5&gt;25/0.5&lt;/TD&gt;
&lt;TD rowSpan=4 colSpan=6&gt;42/0.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=329 colSpan=7&gt;8/0.5&lt;/TD&gt;
&lt;TD colSpan=5&gt;8.5/1&lt;/TD&gt;
&lt;TD colSpan=5&gt;20/1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=329 colSpan=7&gt;5.5/1&lt;/TD&gt;
&lt;TD colSpan=5&gt;4.9/3&lt;/TD&gt;
&lt;TD colSpan=5&gt;11.5/3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=329 colSpan=7&gt;3.175/3&lt;/TD&gt;
&lt;TD colSpan=5&gt;2.2/20&lt;/TD&gt;
&lt;TD colSpan=5&gt;4.9/20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated short-circuit connection capacity I&lt;SUB&gt;cm&lt;/SUB&gt;£¨kA£©&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;twenty&lt;/TD&gt;
&lt;TD colSpan=5&gt;thirty&lt;/TD&gt;
&lt;TD colSpan=5&gt;fifty&lt;/TD&gt;
&lt;TD colSpan=6&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Conversion action time (s)&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;one point five&lt;/TD&gt;
&lt;TD colSpan=5&gt;two&lt;/TD&gt;
&lt;TD colSpan=5&gt;three&lt;/TD&gt;
&lt;TD colSpan=6&gt;one point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Rated control power supply voltage U&lt;SUB&gt;s&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=1081 colSpan=23&gt;230/50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=78 rowSpan=3 width=88&gt;Number of operation cycles (times)&lt;/TD&gt;
&lt;TD width=88&gt;No current flow&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;eight thousand and five hundred&lt;/TD&gt;
&lt;TD colSpan=5&gt;seven thousand&lt;/TD&gt;
&lt;TD colSpan=5&gt;three thousand&lt;/TD&gt;
&lt;TD colSpan=6&gt;four thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88&gt;Current flow&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;one thousand and five hundred&lt;/TD&gt;
&lt;TD colSpan=5&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=5&gt;one thousand&lt;/TD&gt;
&lt;TD colSpan=6&gt;one thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=88&gt;total&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;ten thousand&lt;/TD&gt;
&lt;TD colSpan=5&gt;eight thousand&lt;/TD&gt;
&lt;TD colSpan=5&gt;four thousand&lt;/TD&gt;
&lt;TD colSpan=6&gt;five thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=176 colSpan=2&gt;Dimensions (mm) Width x Height x Depth&lt;/TD&gt;
&lt;TD width=329 colSpan=7&gt;238&#215;165&#215;179&lt;/TD&gt;
&lt;TD colSpan=5&gt;311&#215;236&#215;202&lt;/TD&gt;
&lt;TD colSpan=5&gt;408&#215;310&#215;224&lt;/TD&gt;
&lt;TD colSpan=6&gt;340&#215;416&#215;310&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[dual power switch]CAP1 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/26190.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:39:09</pubDate>
           <comments></comments>
           <description>The CAP1 series automatic transfer switch (hereinafter referred to as the device) is suitable for switching between two neutral grounded power systems (common power supply and backup power supply or common power supply and power generation power supply) with a rated working voltage of AC400V50Hz and a rated working current of 32A to 400A due to an abnormality in one power supply, ensuring the reliability and safety of its power supply. The device can be applied to emergency power supply systems to achieve rapid switching between two power supplies.&lt;BR&gt;This device complies with the latest versions of GB/T14048.11 and IEC60947-6-1 standards.&lt;BR&gt;This device is classified as AC-33B and classified as PC grade.&lt;BR&gt;&lt;BR&gt;The CAP1 series automatic transfer switch has obtained the national mandatory product certification &quot;CCC&quot; mark.&lt;BR&gt;&lt;BR&gt;2. Normal usage conditions&lt;BR&gt;The ambient air temperature ranges from -5 ¡æ to+40 ¡æ; And the average value within 24 hours shall not exceed+35 ¡æ;&lt;BR&gt;The altitude of the installation site shall not exceed 2000m;&lt;BR&gt;The relative humidity of the air at the installation site shall not exceed 50% at a maximum temperature of+40 ¡æ, and may have a higher relative humidity at lower temperatures, such as reaching 90% at 20 ¡æ. Special measures should be taken for occasional condensation caused by temperature changes;&lt;BR&gt;Pollution level is 3;&lt;BR&gt;The installation category is Class III;&lt;BR&gt;&lt;BR&gt;The CAP1 series automatic transfer switch is suitable for electromagnetic environment A.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=64&gt;
&lt;P align=center&gt;Shell code&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=61&gt;
&lt;P align=center&gt;polar number&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;P align=center&gt;Rated working current Ie (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=96&gt;
&lt;P align=center&gt;Rated working voltage&lt;/P&gt;
&lt;P align=center&gt;Ue£¨V£©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=111&gt;
&lt;P align=center&gt;Rated insulation voltage&lt;/P&gt;
&lt;P align=center&gt;Ui£¨V £©&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=108&gt;
&lt;P align=center&gt;Rated impulse withstand voltage Uimp (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=86&gt;
&lt;P&gt;Rated limiting short-circuit current (kA)&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=74&gt;
&lt;P&gt;Rated connection and disconnection capacity (A)&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=42 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=42 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=64&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-32&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=61&gt;
&lt;P align=center&gt;3. 4&lt;/P&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;thirty-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=96&gt;
&lt;P align=center&gt;AC50Hz/400&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=111&gt;
&lt;P align=center&gt;eight hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=108&gt;
&lt;P align=center&gt;eight thousand&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=12 width=86&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one hundred and ninety-two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-63&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;sixty-three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;three hundred and seventy-eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-100 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;six hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=5 width=64&gt;
&lt;P align=center&gt;two hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-125 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;one hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;seven hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-140 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;one hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;eight hundred and forty&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-160 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;one hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;nine hundred and sixty&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-200 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand and two hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-225 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;two hundred and twenty-five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand three hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=64&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;
&lt;P&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;CAP1-250&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;two hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand and five hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-315 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;three hundred and fifteen&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;one thousand eight hundred and ninety&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-350 &amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;three hundred and fifty&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;two thousand and one hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;P&gt;CAP1-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;P align=center&gt;four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=74&gt;
&lt;P align=center&gt;two thousand and four hundred&lt;/P&gt;&lt;/TD&gt;
&lt;TD height=21 width=0&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[dual power switch]CA1B series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/26189.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:39:01</pubDate>
           <comments></comments>
           <description>CA1B series automatic transfer switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center x:str=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;model&lt;/TD&gt;
&lt;TD width=262&gt;CA1B-63&lt;/TD&gt;
&lt;TD width=88&gt;CA1B-100&lt;/TD&gt;
&lt;TD width=88&gt;CA1B-250&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Rated working current I&lt;SUB&gt;e&lt;/SUB&gt;£¨A£©&lt;/TD&gt;
&lt;TD width=262&gt;10~63&lt;/TD&gt;
&lt;TD&gt;10~100&lt;/TD&gt;
&lt;TD&gt;100~250&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Rated working voltage U&lt;SUB&gt;e&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;AC400V/ 50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Rated insulation voltage U&lt;SUB&gt;i&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=438 colSpan=3 x:num=&quot;None&quot;&gt;eight hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;£¨kV£©&lt;/TD&gt;
&lt;TD width=438 colSpan=3 x:num=&quot;None&quot;&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;polar number&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;3. 4&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Usage category&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;AC-33iB¡¢AC-33B&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Conversion action time (s)&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;£¼1.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Rated control power supply voltage U&lt;SUB&gt;s&lt;/SUB&gt;£¨V£©&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;AC230/50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Mechanical lifespan (times)&lt;/TD&gt;
&lt;TD width=438 colSpan=3 x:num=&quot;None&quot;&gt;twelve thousand&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Electrical lifespan (times)&lt;/TD&gt;
&lt;TD width=438 colSpan=3 x:num=&quot;None&quot;&gt;seven thousand and five hundred&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256 colSpan=2&gt;Fault tripping output&lt;/TD&gt;
&lt;TD width=438 colSpan=3&gt;1NO for both normal and standby (without B-type controller)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FDQ3-63 Miniature Circuit Breaker Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/25766.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:51</pubDate>
           <comments></comments>
           <description>FDQ3-63 miniature circuit breaker automatic transfer switch is a device used for automatic switching between mains power and generators in the power grid system, which can ensure continuous power supply. Suitable for important occasions that require continuous power supply, such as residential, hospital, hotel, bank, school, municipal, metallurgical, petrochemical, transportation, communication power supply, etc.&lt;BR&gt;Compliant with GB/T1408.11 Low voltage switchgear and control equipment Part 6-1: Multifunctional electrical switching devices&lt;BR&gt;&lt;BR&gt;Structural characteristics of FDQ3-63 miniature circuit breaker automatic transfer switch&lt;BR&gt;Miniaturization, CB level;&lt;BR&gt;Small circuit breakers as main switches (C65, C45, etc.);&lt;BR&gt;Single motor operation has mechanical interlocking;&lt;BR&gt;Permanent magnet synchronous motor, stable operation;&lt;BR&gt;Adopting a unique patented transmission mechanism to ensure that the closing is fully in place;&lt;BR&gt;Separate the status indication from the motor in place power-off switch to ensure the accuracy of the indication and the reliability of the motor power-off;&lt;BR&gt;The use of plastic casing packaging enhances the protective capability of the mechanism, reduces the influx of moisture, and improves reliability;&lt;BR&gt;ODM customers can install circuit breakers themselves quickly and conveniently. Simply connect the sampling line to the switch, install several components as a whole, and cover the casing to complete the installation.&lt;BR&gt;&lt;BR&gt;Function List of FDQ3-63 Miniature Circuit Breaker Automatic Transfer Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=650 align=center ke-zeroborder?=&quot;None&quot; ?msonormaltable=&quot;None&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;serial number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;function&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Basic type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;multi-functional&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;Remarks&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;one&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Loss of voltage or phase failure&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Commonly used three-phase backup one phase&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Commonly used spare three phases&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;two&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;undervoltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;When this function is available, fix the undervoltage point (special customization is available)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;three&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;overvoltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;When this function is available, fix the overvoltage point (special customization is available)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;four&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Self investment and self recovery&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;As long as the common power supply is maintained normally&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Self-investment without self-recovery&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;six&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Grid - Power Generation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Nothing&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;When this function is available, it comes with a power generation signal output port&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;seven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Fault tripping delay&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Fixed delay&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;Adjustable dialing code&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;eight&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Fire dual input terminal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;DC24V active input, customizable passive input port&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Control power indicator light&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;ten&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Manual automatic status indication&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;eleven&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;Closing and tripping alarm status indicator light&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;When the fault is tripped, manual operation can only be performed, and the output signal is an AC230V active signal.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=45&gt;
&lt;P align=center&gt;twelve&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=104&gt;
&lt;P align=center&gt;External closing and tripping alarm status indication&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=90&gt;
&lt;P align=center&gt;have&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=227&gt;
&lt;P align=center&gt;The output signal is an AC230V active signal.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;FDQ3-63 Miniature Circuit Breaker Automatic Transfer Switch Outline Dimensional Drawing&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201409/20140916161123166.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 274px&quot; border=0 hspace=0 alt=&quot;FDQ3-63 Miniature Circuit Breaker Automatic Transfer Switch Appearance and Installation Dimensions&quot; src=&quot;/upload2014/201409/20140916161123166.jpg&quot; width=680 height=274&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]CCQ2 Series Dual Power Switching System </title>
           <link>http://www.91way.com/info_en/24233.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:42</pubDate>
           <comments></comments>
           <description>Scope of application&lt;BR&gt;The CCQ2 dual power automatic switching device (hereinafter referred to as CCQ2) is suitable for two power sources (common power source and backup power source or power generation power source) with AC 50Hz, 690V and below. It automatically switches between power sources when one power source fails to ensure the reliability and safety of power supply. This product complies with the IEC 60947-6 &quot;Automatic Transfer Switchgear&quot; standard of the International Electrotechnical Commission.&lt;BR&gt;&lt;BR&gt;3. Model and its meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201312/20131211174105409.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/upload2013/201312/20131211174105409.jpg&quot;&gt;&lt;/A&gt;&lt;BR&gt;4. Structure and Performance&lt;BR&gt;4.1 Structure&lt;BR&gt;The CCQ2 dual power automatic switching device is a switching system consisting of two main parts: the device body and the automatic controller, which are connected by a dedicated cable with a maximum length of 2m. The device body consists of two circuit breakers with electric operating mechanisms and accessories (auxiliary and alarm contacts), mechanical interlocking mechanism, fuses, wiring terminals, etc. (hereinafter referred to as the device), all components are installed on a metal base plate, and the mechanical interlocking mechanism is installed between the two circuit breakers. The control power supply voltage of the device is AC230V, and the mechanical life is 5000 times for CCQ2-63~225, 3000 times for CCQ2-400, and 2500 times for CCQ2-630~800.&lt;BR&gt;The automatic controller has a complete plastic shell, installed on the door panel of the box or cabinet, and uses advanced and reliable electronic components to form a complete control circuit inside. The working power supply voltage of the automatic controller is AC230V.&lt;BR&gt;&lt;BR&gt;4.2 Performance&lt;BR&gt;The CCQ2 series dual power switching system simultaneously detects the voltage of two power sources. The power supply voltage that is higher than 110% of the rated value is judged as overvoltage, while the power supply voltage that is lower than 85% of the rated value is judged as undervoltage. The logic circuit makes logical judgments on the above detection results, and the processing results drive the corresponding command relay to issue opening or closing instructions to the electric operating mechanism through the delay circuit. The above detection results are displayed on the panel with light-emitting diodes.&lt;BR&gt;Automatic controllers can be divided into three types based on their control functions: self switching and self restoring (R), self switching and non self restoring (S), and grid power generation (F). The first two types are suitable for the grid power supply system, while the latter type is suitable for the grid power generation system.&lt;BR&gt;4.2.1 The automatic controller (CCQ2R) with self switching and self recovery automatically switches between two power sources (referred to as the common power source and the backup power source). Under normal conditions, it should be powered by the common power supply. When there is an abnormality in the common power supply (overvoltage, undervoltage, or phase loss in any phase voltage), it will automatically switch to the backup power supply after a set delay; After the commonly used power supply returns to normal, it will automatically return to the commonly used power supply after a set delay; When there is an abnormality in the backup power supply (overvoltage, undervoltage, or phase loss in any phase voltage), the controller emits a backup power alarm sound, which can also be manually turned off.&lt;BR&gt;The functions of the self switching and self resetting automatic controller are shown in Table 1.&lt;BR&gt;&lt;BR&gt;Table 1&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;common power supply&lt;/TD&gt;
&lt;TD&gt;backup power supply&lt;/TD&gt;
&lt;TD&gt;Control function&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Common power supply: Q2 split, Q1 combined&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;Common power supply, backup power supply abnormal alarm (can be turned off)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Q1 opens after t1 delay, and Q2 closes after t2 delay - backup power supply&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;return to normal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;After a delay of t3, Q2 opens, and after a delay of t4, Q1 closes - restoring normal power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing and opening of the circuit breaker that controls the common power supply;&lt;BR&gt;Q2 on and Q2 off indicate the closing and opening of the circuit breaker that controls the backup power supply;&lt;BR&gt;T1: Conversion disconnection delay (maximum 60 seconds, minimum 1.5 seconds, factory set at 20 seconds);&lt;BR&gt;T2: Switching on delay (maximum 2 seconds, minimum 0.7 seconds. Factory set at 1 second);&lt;BR&gt;T3: Return disconnect delay (maximum 60 seconds, minimum 1.5 seconds, factory set at 20 seconds);&lt;BR&gt;T4: Return connection delay (maximum 2 seconds, minimum 0.7 seconds, factory set at 1 second);&lt;BR&gt;The delay setting value is free from user self adjustment. The user requests to set it at another time. Please specify when placing an order.&lt;BR&gt;4.2.2 The automatic controller (CCQ2S) that automatically switches between two power sources (referred to as the common power source and the backup power source, respectively). When there is an abnormality in the common power supply (overvoltage, undervoltage, or phase loss in any phase voltage), it automatically switches to the backup power supply after a set delay. However, when the common power supply returns to normal, it cannot automatically recover until the backup power supply has an abnormality before switching.&lt;BR&gt;The functions of the automatic controller with automatic switching and non automatic recovery are shown in Table 2.&lt;BR&gt;&lt;BR&gt;Table II&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;common power supply&lt;/TD&gt;
&lt;TD&gt;backup power supply&lt;/TD&gt;
&lt;TD&gt;Control function&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Common power supply: Q2 split, Q1 combined&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Q1 opens after t1 delay, and Q2 closes after t2 delay - backup power supply&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;return to normal&lt;/TD&gt;
&lt;TD&gt;Normal&lt;/TD&gt;
&lt;TD&gt;Still powered by backup power supply&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;After a delay of t3, Q2 opens, and after a delay of t4, Q1 closes - powered by the common power supply&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing and opening of the circuit breaker that controls the common power supply;&lt;BR&gt;Q2 on and Q2 off indicate the closing and opening of the circuit breaker that controls the backup power supply;&lt;BR&gt;T1: Conversion disconnection delay (maximum 60 seconds, minimum 1.5 seconds, factory set at 20 seconds);&lt;BR&gt;T2: Switching on delay (maximum 2 seconds, minimum 0.7 seconds, factory set at 1 second);&lt;BR&gt;The delay setting value is free from user self adjustment. The user requests to set it at another time. Please specify when placing an order.&lt;BR&gt;4.2.3 Grid - The automatic controller for power generation (CCQ2F) automatically switches between the grid and the two power sources. When the grid voltage is below 85% of the rated voltage, a power generation command is issued through a power generation delay command (output through a set of normally open and normally closed contacts). When the generated voltage reaches 85% of the rated voltage, the load circuit is first disconnected from the power grid. After a delay in the unloading instruction, the unloading instruction is issued to remove the secondary load (output through another set of normally open and normally closed contacts), and then the generated power supply is connected through a conversion delay. After the grid voltage returns to normal (reaching 85% of the rated voltage or above), the load circuit is disconnected from the power source after a return disconnection delay, and then automatically switched to grid power supply after a return connection delay. The power generation delay (t5=2100 seconds) is adjusted and set by the potentiometer on the right side of the panel (set to 20 seconds at the factory), and the return disconnection delay (t3=1.5 60 seconds) is adjusted and set by the potentiometer on the left side of the panel (set to 20 seconds at the factory).&lt;BR&gt;The functions of the power grid power generation automatic controller are shown in Table 3&lt;BR&gt;&lt;BR&gt;Table 3&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Grid power supply&lt;/TD&gt;
&lt;TD&gt;Power generation source&lt;/TD&gt;
&lt;TD&gt;Automatic control function&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Not generating electricity&lt;/TD&gt;
&lt;TD&gt;Power supply from the power grid; Q2 division, Q1 combination&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;No power generation&lt;/TD&gt;
&lt;TD&gt;After a delay in issuing the power generation command, the generator set generates electricity&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;abnormal&lt;/TD&gt;
&lt;TD&gt;Normal power generation&lt;/TD&gt;
&lt;TD&gt;After a delay of T2, Q1 opens and Q2 closes, powered by the power generation unit&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;return to normal&lt;/TD&gt;
&lt;TD&gt;normal&lt;/TD&gt;
&lt;TD&gt;Request power outage. After a delay of T1, Q2 will be disconnected and Q1 will be closed, automatically restoring power supply to the common power source&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing and opening of the circuit breaker that controls the common power supply;&lt;BR&gt;Q2 on and Q2 off indicate the closing and opening of the circuit breaker that controls the backup power supply.&lt;BR&gt;Other products: CCQ2A series dual power switching system&lt;BR&gt;With the development of society, people's demand for power supply reliability is also increasing. Many fields use two independent power sources to ensure normal power supply, so a device that can automatically switch between the two power sources is needed to ensure uninterrupted power supply. The CCQ2A dual power automatic switching device is a second-generation device that has been redeveloped based on the original CCQ2 dual power automatic switching device, effectively reducing the height of the product. This product can not only switch between two power sources, but also adopts single motor control. Its characteristics are simple structure, easy operation, and reliable performance. This product has two switching functions: self switching and self resetting, and self switching and non self resetting. It detects the two power sources of the three-phase four wire power grid. When any one of the power sources is abnormal, it can automatically switch from the abnormal power source to the normal power source; Products used in power grid generation systems can also emit power generation signals. Therefore, it is a dual power automatic switching device with complete performance, safety and reliability, high degree of automation, and wide range of applications.&lt;BR&gt;CCQ2B Intelligent Dual Power Control System&lt;BR&gt;This product is an upgraded version of the original CCQ2A dual power automatic switching device. In this product, a microcomputer and a fully Chinese interface operating system have been introduced, thus solving some technical problems that were not solved by the original CCQ2A product. This product has two switching functions: self switching and self resetting, and self switching and non self resetting. It performs real-time detection and display of the effective values and phases of the three-phase voltage of the two power sources supplied by the three-phase four wire power grid. When any phase experiences overvoltage or undervoltage (including phase loss), it automatically switches from the abnormal power source to the normal power source; The product used in the power generation system of the power grid can also emit power generation and unloading signals, automatically communicate with the upper computer and perform remote control. Therefore, it is a dual power control system product with complete performance, safety and reliability, easy operation, high degree of intelligence, leading technical level in China, and wide range of applications.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SRMQ3-63 type dual power switch </title>
           <link>http://www.91way.com/info_en/23505.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:33</pubDate>
           <comments></comments>
           <description>Model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130701210038524.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 413px; HEIGHT: 184px&quot; border=0 hspace=0 alt=&quot;SRMQ3-63 Dual Power Switch Model Description&quot; src=&quot;/upload2013/201307/20130701210038524.jpg&quot; width=413 height=184&gt;&lt;/A&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SRMQ3-63L type dual power switch </title>
           <link>http://www.91way.com/info_en/23504.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:23</pubDate>
           <comments></comments>
           <description>Model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130701205741692.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 427px; HEIGHT: 212px&quot; border=0 hspace=0 alt=&quot;SRMQ3-63L Dual Power Switch Model Description&quot; src=&quot;/upload2013/201307/20130701205741692.jpg&quot; width=427 height=212&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Scope and characteristics of application&lt;BR&gt;SRMQ3-63L automatic transfer switch is suitable for AC 50Hz, rated voltage 380V/220V; In a three-phase four wire (or single-phase one wire) dual power supply grid with a rated current of up to 63A, when one power supply fails (only detecting A-phase voltage, only detecting undervoltage and phase loss), one or several load circuits are automatically connected from one power supply to the other to ensure the normal power supply of the load circuit.&lt;BR&gt;The product complies with the IEC60947-6-1 standard and GB/T14048.11 standard, and has the international advanced level of the 1990s.&lt;BR&gt;&lt;BR&gt;Normal working conditions&lt;BR&gt;Surrounding air temperature: The upper limit should not exceed+40 ¡æ, the lower limit should not be lower than -5 ¡æ, and the average value over 24 hours should not exceed -35 ¡æ;&lt;BR&gt;Altitude: The installation location has an altitude not exceeding 2000m; Atmospheric conditions: The air is clean; The relative humidity of the atmosphere does not exceed 50% at a maximum ambient temperature of+40 ¡æ, and can have higher relative humidity at lower temperatures. When the average lowest temperature in the wettest month is -25 ¡æ, the average maximum relative humidity for that month is 90%, taking into account condensation on the surface of the product due to temperature changes. Special measures should be taken for occasional condensation caused by temperature changes.&lt;BR&gt;&lt;BR&gt;structure and performance &lt;BR&gt;The SRMQ3-63L automatic transfer switch is composed of actuating components (small circuit breaker DZ47), single motor electric operating mechanism, mechanical interlocking, auxiliary system, control circuit, etc. All components are installed on the same metal base plate, and the controller panel has clear status indicator lights to accurately indicate the status of the small circuit breaker. The control power supply voltage of the conversion switch is AC220V, and the mechanical life is 10000 times.&lt;BR&gt;The automatic controller (only self switching and self resetting) simultaneously detects the voltage of two power sources (referred to as the common power source and the backup power source). In normal condition, it is powered by the common power source. When the common power source experiences an abnormality, such as voltage loss or phase loss (phase A of the small circuit breaker), the automatic controller will instruct the transfer switch to automatically switch to the backup power source for power supply; After the common power supply is restored to normal, the automatic controller will instruct the conversion switch to automatically return to the common power supply without delay; It is not allowed for two abnormal paths to occur simultaneously.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]End type dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/23503.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:13</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Model meaning&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130701205427424.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 372px; HEIGHT: 226px&quot; border=0 hspace=0 alt=&quot;SRMQ2/63-225 End Type Dual Power Automatic Transfer Switch Model Description&quot; src=&quot;/upload2013/201307/20130701205427424.jpg&quot; width=372 height=226&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Scope and characteristics of application&lt;BR&gt;The SRMQ2 automatic power switch (hereinafter referred to as the switch) is suitable for dual power supply systems with AC 50HZ rated working voltage of 380V and rated working current of 63A-225A. It can be operated automatically or manually to switch between the common power supply and the backup power supply. This toggle switch is mainly used in important occasions such as hospitals, shops, banks, chemical, metallurgical, high-rise buildings, military facilities, etc. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Normal working conditions&lt;BR&gt;1. The installation altitude should not exceed 2000 meters.&lt;BR&gt;2. The upper limit of the ambient temperature shall not exceed+40 ¡æ, the lower limit shall not be lower than -5 ¡æ, and the 24-hour average shall not exceed+35 ¡æ.&lt;BR&gt;3. The relative humidity of the atmosphere should not exceed 50% when the surrounding air temperature is+40 ¡æ. At lower temperatures, there may be higher humidity, and temperature changes should be considered to cause condensation on the surface of the product.&lt;BR&gt;4. The medium has no explosive hazard, and there is no gas or dust that can corrode or damage the insulation.&lt;BR&gt;5. A place without significant shaking or impact vibration. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Installation and usage methods&lt;BR&gt;When wiring, the common power supply N should be connected to the common power supply executing circuit breaker QN, and the backup power supply R should be connected to the backup power supply executing circuit breaker QR. When QN and QR are four wire circuit breakers, the wiring method should follow the wiring diagram, where QN and QR have 1, 3, and 5 as the three-phase (A, B, C) incoming terminals, 2, 4, and 6 as the three-phase outgoing terminals, 7 as the neutral line (N) incoming terminal, and 8 as the neutral line outgoing terminal. If a three pole circuit breaker is selected, the neutral wire NN of the common power supply (N) and the neutral wire NR of the backup power supply (R) must be connected to the three pole dedicated neutral wire terminal KG at the same time. Please refer to the wiring diagram for specific instructions. The working power supply of the dual power switch automatic controller is taken from the input terminals A and neutral wires N of circuit breakers QN and QR. If a three pole circuit breaker is selected, the neutral wires NN and NR must be connected. The dedicated neutral terminal of the three pole wiring is located between the two circuit breakers. During the installation of the automatic power switch, do not connect the original wire to the input terminal of the circuit breaker&lt;BR&gt;Forgetting, breaking or short circuiting of the local controller cable.&lt;BR&gt;1. Common neutral wire&lt;BR&gt;2. Backup neutral wire&lt;BR&gt;3. Indicator light common terminal&lt;BR&gt;4. Common indicator lights&lt;BR&gt;5. Backup indicator light&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130701205441108.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 403px; HEIGHT: 335px&quot; border=0 hspace=0 alt=&quot;SRMQ2/63-225 Terminal Type Dual Power Automatic Transfer Switch Wiring Diagram&quot; src=&quot;/upload2013/201307/20130701205441108.jpg&quot; width=403 height=335&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SRMQH2/63-1250 type dual power switch </title>
           <link>http://www.91way.com/info_en/23502.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:38:04</pubDate>
           <comments></comments>
           <description>Model meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130701205129825.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 450px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;SRMQH2/63-1250 Dual Power Switch Model Description&quot; src=&quot;/upload2013/201307/20130701205129825.jpg&quot; width=450 height=310&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Intelligent controller function&lt;BR&gt;SRMQH2 is a new intelligent dual power conversion switch. The intelligent controller is equipped with keyboard input and LCD display, which can synchronously detect the common power supply (N) and backup power supply (R) in three phases. It has the function of detecting overvoltage, undervoltage, phase failure or loss of voltage. When it is higher than 120% of the rated working voltage value, it is judged as overvoltage, and when it is lower than 75% of the rated working voltage value, it is judged as undervoltage. The backup power supply (R) fault alarm and double division are triggered. The microcomputer processes the detection results and issues corresponding instructions. The processing results can be displayed on the LCD, providing users with a good human-machine dialogue interface. The alarm can also be manually closed by pressing the button. At present, regardless of the working mode, the microcomputer detects abnormal data and delays for 3 seconds to disconnect the abnormal power supply and enter the dual protection state. After a delay of 0-30 seconds, it switches to normal power supply.&lt;BR&gt;Example: In the self switching and self recovery mode, if the common power supply (N) fails, it will automatically switch to the backup power supply (R) for power supply. If the common power supply (N) returns to normal, it will automatically return. If both working power supplies fail, the microcomputer will issue a double split command after 3 seconds. If the power supply returns to normal, it will be prioritized for operation. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Structure and Function&lt;BR&gt;This intelligent conversion switch consists of two main parts: a microcomputer controller and a switch conversion device, which are connected by dedicated cables.&lt;BR&gt;The switch consists of a microcomputer controller, a micro motor, a gear box, a micro switch, an operation keyboard, an LCD display, a molded case circuit breaker, etc. Equipped with automatic, manual, and dual split operation; The characteristics of mechanical and electrical dual interlocking maximize the satisfaction of power supply and distribution needs.&lt;BR&gt;The switch has three status positions for users to choose from: common power (N) on, double off, and backup power (R) on. The switch has the characteristics of small size, light weight, stable operation, and easy use. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;work mode&lt;BR&gt;Self investment and self recovery (R) power grid and power grid&lt;BR&gt;Self investment non self recovery (S) type power grid and power grid&lt;BR&gt;Self investment and self recovery (F) type power grid and power generation&lt;BR&gt;(Additional fire protection function (DC24V) can also be added)&lt;BR&gt;&lt;BR&gt;Self investment and self restoration (R) power grid - power grid&lt;BR&gt;At the initial startup, it is automatically powered by the commonly used power supply. When there is an abnormality in the power supply (overvoltage, undervoltage, undervoltage, or phase failure), the NA, NB, NC, RA, RB, and RC on the controller LCD will disappear accordingly. The common power supply (N) will automatically switch to a dual split state after 3 seconds of abnormal operation, and then switch to the backup power supply (R) for power supply after a delay of 0-30 seconds. The delay time can be set to 3 seconds at the factory. When the common power supply returns to normal, it will automatically switch from the backup power supply to the common power supply (N) for power supply; The backup power supply (R) is abnormal, and the controller will emit a &quot;beep&quot; alarm sound. This alarm can also be manually turned off. The word 'alarm' disappears on the LCD, indicating that the alarm system has been turned off and there is no 'alarm' function at this time. Pressing the down key will display the word &quot;alarm&quot; and make a beep at the same time, indicating that the alarm system has been turned on.&lt;BR&gt;At the initial startup, it is automatically powered by the commonly used power supply. When there is an abnormality in the power supply (overvoltage, undervoltage, undervoltage, or phase failure), the NA, NB, NC, RA, RB, and RC on the controller LCD will disappear accordingly. The commonly used power supply (N) will automatically switch to a dual split state after 3 seconds of abnormality, and then switch to the backup power supply (R) for power supply after a delay of 0-30 seconds. The delay time can be set to 3 seconds at the factory.&lt;BR&gt;After the common power supply returns to normal, the backup power supply (R) cannot automatically return to the common power supply (N) and needs to be manually returned; At this time, the backup power supply (R) is also abnormal, and the controller will emit a &quot;beep&quot; alarm sound. At the same time, if the power supply is restored to normal after switching to the double split position, priority should be given to putting it into operation. This alarm can also be manually turned off. The disappearance of the LCD &quot;alarm&quot; indicates that the alarm system has been turned off, and there is no &quot;alarm&quot; function at this time. Pressing the down key will display the word 'alarm', and a beep will sound at the same time, indicating that the alarm system has been turned on. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Self investment and self restoration (F) power grid - power generation&lt;BR&gt;The controller detects the common power source (N) and the power generation source (R). When the common power source (N) is abnormal, the control system sends a power generation command (normally open contact) to the generator set to start it. When the voltage of the generator set reaches the normal working voltage value, the controller sends a command to put the power generation source into use, ensuring the normal operation of the generator set. When the voltage of the generator drops below 75% of the rated value, the control system automatically disconnects the load and enters a double split state. After the grid voltage (N) returns to normal, the intelligent system will automatically return from the backup power source (R) to the common power source (N) for power supply after a delay, and the generator set needs to be manually shut down.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HZQE Dual power automatic switching device </title>
           <link>http://www.91way.com/info_en/22960.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:54</pubDate>
           <comments></comments>
           <description>The HZQE series dual power automatic switching device is suitable for AC 50Hz. It is used in the power supply system of the Shu'an Road power supply with a rated voltage of 690V and a rated current of 6300A to achieve automatic switching between the common power supply (N) and the backup power supply (R) (which can also be set to manual switching), enabling dual power supply users to achieve unmanned substations. This product is suitable for special and Class I power systems, high-rise buildings, residential areas, military facilities, hospitals, airports, docks, shopping malls, communication, fire protection, metallurgy, chemical industry, textiles, petroleum, coal mines and other important places that do not allow power outages.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HBK¡õ-16-100 series dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/22917.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:45</pubDate>
           <comments></comments>
           <description>HBK ¡õ -16-100 Series Dual Power Automatic Transfer Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HBK¡õ-16-630 Dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/22916.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:36</pubDate>
           <comments></comments>
           <description>HBK ¡õ-16-630 Dual Power Automatic Transfer Switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HBK Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/22915.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:26</pubDate>
           <comments></comments>
           <description>The HBK series dual power automatic transfer switch uses a reversible motor to control two circuit breakers, and automatically switches between dual power sources through a controller and interlocking mechanism. It has the characteristics of small size, low cost, high performance, and reliability&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]RMQ5 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/21828.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:16</pubDate>
           <comments></comments>
           <description>Characteristics of RMQ5 series automatic transfer switch&lt;BR&gt;&lt;BR&gt;The unique eccentric selection structure design forms a reliable mechanical interlock, ensuring that only one power source is connected, and there is no possibility of two power sources being connected to the load at the same time.&lt;BR&gt;The design of an independent arc extinguishing system ensures reliable extinguishing of various abnormal arcs, with short arc duration and minimal contact loss.&lt;BR&gt;The multi piece contact system design, reasonable contact surface area and pressure of the contacts, prevent overheating and welding of the contacts, effectively extend the service life of the contacts, and ensure the high breaking capacity of the product.&lt;BR&gt;The mechanism design adopts electromagnet, with fast conversion speed.&lt;BR&gt;The transfer switch has different types of two-stage and three-stage, suitable for various application scenarios. Can be equipped with fuse protection and molded case circuit breaker protection, facilitating user system design.&lt;BR&gt;Equipped with an intelligent controller, it can achieve functions such as self switching and self recovery, self switching and non self recovery, and power grid generator selection. The intelligent controller adopts microprocessor technology, and the conversion action voltage and time delay can be adjusted and set by the user.&lt;BR&gt;Voltage and time values are displayed on digital tubes.&lt;BR&gt;Adopting Modbus RTU communication protocol for easy access to smart grid systems.&lt;BR&gt;The commonly used power supply and backup power supply inside the intelligent controller are isolated by the system for higher safety.&lt;BR&gt;It has fire protection function and can meet fire protection requirements.&lt;BR&gt;Simple structure and small volume; Easy installation, operation, and maintenance; Reliable and stable conversion, long service life; No noise, low impact.&lt;BR&gt;&lt;BR&gt;RMQ5 series automatic transfer switch specifications&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;Model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=left&gt;RMQ5 III (three-stage)/RMQ5 II (two-stage)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;Shell level&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=118&gt;
&lt;P align=center&gt;63A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;125A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;250A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P align=center&gt;500A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;P align=center&gt;800A (without two-stage)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=118&gt;
&lt;P align=center&gt;16A¡¢ 20A¡¢ 25A¡¢ 32A¡¢ 40A¡¢ 50A¡¢ 63A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=119&gt;
&lt;P align=center&gt;80A¡¢ 100A¡¢ 125A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;P align=center&gt;160A¡¢ 200A¡¢ 225A¡¢ 250A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=110&gt;
&lt;P&gt;350A¡¢ 400A¡¢ 500A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;P align=center&gt;630A£¬ 800A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;rated voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=center&gt;AC380V/400V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;wiring method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=455 colSpan=4&gt;
&lt;P align=center&gt;counter&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=112&gt;
&lt;P align=center&gt;Behind the board&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;Usage category&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=center&gt;AC-33B (10Ie on, 10Ie off) COS ¦µ=0.35, when (Ie ¡Ü 100A, COS¦µ=0.45)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;Rated impulse withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=center&gt;8kV (main circuit), 4kV (auxiliary circuit)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P&gt;Rated insulation voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=center&gt;AC800V (main circuit), AC300V (auxiliary circuit)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=131&gt;
&lt;P align=left&gt;Electrical grade&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=567 colSpan=5&gt;
&lt;P align=center&gt;PC level&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMQ5 series automatic transfer switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]XSTC Dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/20151.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:37:07</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120819161306727.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 662px; HEIGHT: 441px&quot; border=0 hspace=0 alt=&quot;Selection Instructions for XSTC Dual Power Automatic Transfer Switch&quot; src=&quot;/upload2012/201208/20120819161306727.jpg&quot; width=662 height=441&gt;&lt;/A&gt;&lt;BR&gt;XSTC dual power automatic transfer switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]XSTE Dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/20150.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:59</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201208/20120819161149237.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 670px; HEIGHT: 525px&quot; border=0 hspace=0 alt=&quot;Selection Instructions for XSTE Dual Power Automatic Transfer Switch&quot; src=&quot;/upload2012/201208/20120819161149237.jpg&quot; width=670 height=525&gt;&lt;/A&gt;&lt;BR&gt;XSTE dual power automatic transfer switch&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]GQ1 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/18253.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:50</pubDate>
           <comments></comments>
           <description>Scope of application&lt;BR&gt;GQ1 series dual power automatic transfer switch is suitable for dual power supply systems with AC 50, 60Hz, rated voltage below 690V, and rated current below 1250A. It can achieve automatic switching between the commonly used power source (N) and the backup power source (R) (which can also be set to manual switching), and can also automatically start the generator with the generator as the backup power source. The generator should have automatic starting hardware without the need for manual operation. Instantaneous interruption of power supply to the load during the conversion period. Mainly used in important places where power outages are not allowed, such as high-rise buildings, residential areas, hospitals, airports, docks, shopping malls, communication, fire protection, metallurgy, chemical industry, textiles, petroleum, coal mines, etc. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;meet the standard&lt;BR&gt;GB 14048.1 General Principles for Low Voltage Switchgear and Control Equipment&lt;BR&gt;GB 14048.2 &quot;Low voltage switchgear and control gear - Low voltage circuit breakers&quot;&lt;BR&gt;GB 14048.11 &quot;Low voltage switchgear and control equipment - Part 6: Multifunctional electrical switching devices&quot;&lt;BR&gt;GB 10963 &quot;Overcurrent protection circuit breakers for household and similar use&quot;&lt;BR&gt;GB 7251 &quot;Low voltage switchgear and control equipment - Low voltage circuit breakers&quot;&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]GQ1B Series Dual Power Switching Device </title>
           <link>http://www.91way.com/info_en/18240.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:42</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The GQ1B series intelligent dual power automatic conversion device (ATSE) is a specialized intelligent product developed to achieve reliable conversion between two power sources. Suitable for dual power supply system with AC 50Hz and 380V, it can automatically switch between common power supply and backup power supply to ensure power supply reliability and safety. Mainly used in important places such as hospitals, shopping malls, finance, national defense, subways, chemical, metallurgical, mining, high-rise buildings, and fire protection where power outages are not allowed. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;meet the standard&lt;BR&gt;GB 14048.1 General Principles for Low Voltage Switchgear and Control Equipment&lt;BR&gt;GB 14048.2 &quot;Low voltage switchgear and control gear - Low voltage circuit breakers&quot;&lt;BR&gt;GB 14048.11 &quot;Low voltage switchgear and control equipment - Part 6: Multifunctional electrical switching devices&quot;&lt;BR&gt;GB 10963 &quot;Overcurrent protection circuit breakers for household and similar use&quot;&lt;BR&gt;GB 7251 &quot;Low voltage switchgear and control equipment - Low voltage circuit breakers&quot;&lt;BR&gt;&lt;BR&gt;technical parameters&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201202/20120216134805871.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 521px&quot; border=0 hspace=0 alt=&quot;Technical parameters of GQ1B series dual power switching device&quot; src=&quot;/upload2012/201202/20120216134805871.jpg&quot; width=650 height=521&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]CA1 series dual power conversion switch </title>
           <link>http://www.91way.com/info_en/17523.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:33</pubDate>
           <comments></comments>
           <description>The main performance, control functions, appearance and installation dimensions of the CA1 series automatic transfer switch, and electrical schematic diagram&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P align=center&gt;CA1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;controller type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=498 colSpan=7&gt;
&lt;P align=center&gt;Electronic type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;Intelligent type (intelligent communicable type)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;Converter model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=258 colSpan=3&gt;
&lt;P align=center&gt;W-shaped&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=240 colSpan=4&gt;
&lt;P align=center&gt;Q-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=left&gt;Main performance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=258 colSpan=3&gt;
&lt;P&gt;Detect the voltage of either phase of the commonly used or backup power supply. If the detected phase voltage drops below 30% of the rated control power supply voltage, there is a phase loss, or the power supply is cut off, action will be taken.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=240 colSpan=4&gt;
&lt;P&gt;Detect the voltage of each phase of the commonly used power supply and any phase voltage of the backup power supply. If the detected phase experiences overvoltage, undervoltage, phase loss, or power outage, the action will be taken.&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=300 colSpan=2&gt;
&lt;P align=center&gt;Detect the voltage of each phase of the commonly used power supply and the A-phase voltage of the backup (or power generation) power supply. If the detected phase experiences overvoltage, undervoltage, phase loss, or power outage, take action.&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=4 width=121&gt;
&lt;P align=left&gt;Four position working status&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P&gt;a. Automatic operation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P&gt;b. Mandatory use of &quot;common&quot; power sources (or grid power sources)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P&gt;c. Mandatory backup power source (or power generation source)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P align=center&gt;d. Stop (all closed)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;Automatic controller status indication&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=798 colSpan=9&gt;
&lt;P align=center&gt;Closing, opening, and fault tripping&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;Undervoltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=194 colSpan=2&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=196 colSpan=3&gt;
&lt;P align=center&gt;50% to 90% rated voltage, user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=408 colSpan=4&gt;
&lt;P align=center&gt;65%, 75%, 85% rated voltage, user adjustable&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;overvoltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=194 colSpan=2&gt;
&lt;P align=center&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=196 colSpan=3&gt;
&lt;P align=center&gt;105% to 120% rated voltage, adjustable by the manufacturer&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=408 colSpan=4&gt;
&lt;P align=center&gt;115% rated voltage&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=121&gt;
&lt;P align=left&gt;control function&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=97&gt;
&lt;P align=center&gt;R-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=97&gt;
&lt;P align=center&gt;S-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98 colSpan=2&gt;
&lt;P align=center&gt;Fire linkage type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;F-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;R-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 colSpan=2&gt;
&lt;P align=center&gt;S-type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=242&gt;
&lt;P align=center&gt;F-type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=97&gt;
&lt;P align=center&gt;Self switching and self recovery in the common backup room&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=97&gt;
&lt;P align=center&gt;The automatic switching and non recovery of the common backup room&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98 colSpan=2&gt;
&lt;P align=center&gt;Optional R/S type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;Self switching and self recovery between commonly used power sources&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83&gt;
&lt;P align=center&gt;Self switching and reuse between common and backup rooms&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=83 colSpan=2&gt;
&lt;P align=center&gt;Self switching between common and backup rooms without reuse&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=242&gt;
&lt;P align=center&gt;Self switching and reuse between commonly used power generation sources&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=121&gt;
&lt;P align=center&gt;Control characteristics*&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=292 colSpan=4&gt;
&lt;P align=center&gt;T1 and t3 are user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=98&gt;
&lt;P align=center&gt;T1, t2, t3, t4, t5, t6 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=166 colSpan=3&gt;
&lt;P align=center&gt;T1, t2, t3, t4 are user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=242&gt;
&lt;P align=left&gt;T1, t2, t3, t4, t5, t6 user adjustable&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&#183;Introduction to the Three Control Functions of CA1 Series Automatic Transfer Switch Controller: R-Type, S-Type, and F-Type&lt;BR&gt;&#183;Automatic switching and restoration between power grids (R-type)&lt;BR&gt;The R-type controller automatically switches between two power sources, namely the common power source and the backup power source. When in normal condition, it should be powered by the common power supply. When there is an abnormality in the common power supply (overvoltage, undervoltage, phase loss, or power outage of the detected phase voltage), it will automatically switch to the backup power supply after a set delay time; After the common power supply returns to normal, it will automatically return to the common power supply after the set delay time.&lt;BR&gt;&lt;BR&gt;The functions of the R-type controller are shown in the table below:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;common power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;backup power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P align=center&gt;control function&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;Common power supply: Q1 on, Q2 off&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;abnormal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;After t1 delay, Q1 is divided, and after t2 delay, Q2 is closed - backup power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;return to normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;After a delay of t3, Q2 is divided, and after a delay of t4, Q1 is closed - restoring normal power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing or opening of the circuit breaker that controls the common power supply;&lt;BR&gt;Q2 on and Q2 off indicate the closing or opening of the circuit breaker that controls the backup power supply.&lt;BR&gt;Self switching and non self recovery between power grids (S-type)&lt;BR&gt;The controller that automatically switches between two power sources (referred to as the common power source and the backup power source, respectively) without self restoration. When there is an abnormality in the commonly used power supply (overvoltage, undervoltage, phase loss, or power outage of the detected phase voltage), it automatically switches to the backup power supply after a set delay. However, when the commonly used power supply returns to normal, it cannot automatically recover. Only switch when there is an abnormality in the backup power supply.&lt;BR&gt;&lt;BR&gt;The functions of the S-type controller are shown in the table below:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;common power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Backup power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P align=center&gt;control function&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;Common power supply: Q1 on, Q2 off&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;abnormal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;After t1 delay, Q1 is divided, and after t2 delay, Q2 is closed - backup power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;return to normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;Still powered by backup power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=115&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P align=center&gt;Abnormal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=475&gt;
&lt;P&gt;After a delay of t3, Q2 is divided, and after a delay of t4, Q1 is closed - powered by a common power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing or opening of the circuit breaker that controls the common power supply;&lt;BR&gt;Q2 on and Q2 off indicate the closing or opening of the circuit breaker that controls the backup power supply.&lt;BR&gt;Self switching and self restoration between power grid and power generation source (F-type)&lt;BR&gt;The F-type controller automatically switches between two power sources, namely the grid power source and the power generation power source. When there is an abnormality in the power supply of the grid (overvoltage, undervoltage, phase loss, or power outage of the detected phase voltage), the controller delays the power generation command and sends a power generation command request. When the power supply voltage reaches 50% to 90% of the rated voltage (for Q-type converters) or 70% of the rated control power supply voltage (for W-type adapters), the device disconnects the load circuit from the grid and automatically switches to the power supply. After the grid voltage returns to normal, it automatically returns to the grid for power supply and issues a command to stop power generation.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Grid power supply&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=151&gt;
&lt;P align=center&gt;Power generation source&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=471&gt;
&lt;P align=center&gt;control function&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=151&gt;
&lt;P align=center&gt;No power generation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=471&gt;
&lt;P&gt;Grid power supply: Q1 on, Q2 off&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;abnormal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=151&gt;
&lt;P align=center&gt;No power generation&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=471&gt;
&lt;P&gt;Delayed issuance of power generation command t5, waiting for power generation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;abnormal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=151&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=471&gt;
&lt;P&gt;After a delay of t1, Q1 is divided and an unloading instruction is issued. After a delay of t2, Q2 is closed - the power supply is used for power generation&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;return to normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=151&gt;
&lt;P align=center&gt;normal&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=471&gt;
&lt;P&gt;After the stable time of the power grid reaches the t6 setting value, a command to stop power generation is issued. After a delay of t3, Q2 is divided, and then after a delay of t4, Q1 is closed - automatically returning to the power grid for power supply&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Note: Q1 on and Q1 off indicate the closing or opening of the circuit breaker that controls the power supply of the power grid;&lt;BR&gt;Q2 on and Q2 off indicate the closing or opening of the circuit breaker that controls the backup power supply.&lt;BR&gt;&lt;BR&gt;Control characteristics of R-type, S-type, and F-type automatic controllers:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;Rated control power supply voltage Us (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;Conversion disconnection delay time t1 (s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;Switching on delay time t2 (s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;Return disconnect delay time t3 (s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;Return the connection delay time t4 (s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;Power generation instruction delay time t5 (s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;Delay time t6 (s) for power generation shutdown command&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;CA1R&lt;BR&gt;CA1S&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;AC230&amp;nbsp;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;zero point five&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;¡ª¡ª&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;¡ª¡ª&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;CA1F&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;AC230&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=94&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=95&gt;
&lt;P align=center&gt;0.5-64 user adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=88&gt;
&lt;P align=center&gt;1-180 users adjustable&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=102&gt;
&lt;P align=center&gt;32 to 600 users adjustable&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Main specifications and selection of circuit breakers for CA1 automatic transfer switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;Circuit breaker executed&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Number of poles and short-circuit breaking capacity level of circuit breaker&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;rated current&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;Rated working voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=78&gt;
&lt;P align=center&gt;Rated insulation voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=79&gt;
&lt;P align=center&gt;rated frequency&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-63&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-63&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (L, M)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;(6) 10, 16, 20, 25, 32, 40, 50, 63&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=78&gt;
&lt;P align=center&gt;400V&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=78&gt;
&lt;P align=center&gt;500V&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=7 width=79&gt;
&lt;P align=center&gt;50Hz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-100&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (C, L, M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;(10) 16, 20, 25, 32, 40, 50, 63, 80, 100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-160&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-160&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (C, L, M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;100, 125, 140, 160&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-225&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-225&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (C, L, M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;100, 125, 140, 160, 180, 200, 225&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-400&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (C, L, M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;225, 250, 315, 350, 400&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-630&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-630&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (C, L, M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;400, 500, 630&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=106&gt;
&lt;P align=center&gt;CA1-800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=107&gt;
&lt;P align=center&gt;CM1-800&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=144&gt;
&lt;P align=center&gt;Three poles (M, H)&lt;BR&gt;quadrupole&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=163&gt;
&lt;P align=center&gt;630, 700, 800&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CA1 series dual power conversion switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]TIQ1 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/17510.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:24</pubDate>
           <comments></comments>
           <description>The TIQ1 series dual power automatic transfer switch has overvoltage, undervoltage, and phase failure automatic switching functions to ensure the high reliability operation of the distribution system. Its characteristics are:&lt;BR&gt;There is a reliable mechanical interlocking mechanism and an intelligent electrical interlocking dual protection system with MOTOROLA microcontroller as the core between the two circuit breakers;&lt;BR&gt;Equipped with automatic switching and intelligent alarm functions for overvoltage, undervoltage, and phase failure;&lt;BR&gt;Equipped with intelligent protection and control functions for motor operation;&lt;BR&gt;Parameters can be freely set externally;&lt;BR&gt;Compact size, safe and convenient to use;&lt;BR&gt;Energy saving and noise free operation;&lt;BR&gt;Equipped with a fire control terminal, when the fire control center sends a full closing signal to the intelligent controller, both circuit breakers enter the open state;&lt;BR&gt;The product structure is made of high-quality cold-rolled steel plates processed by CNC, with a beautiful and novel appearance. The surface adopts advanced electrostatic powder spraying technology, and the coating has strong corrosion resistance and good strength;&lt;BR&gt;The product has a high degree of standardization and strong universality. The external dimensions and installation dimensions of the three pole and four pole automatic transfer switches are unified, which can facilitate user design and selection.&lt;BR&gt;This product complies with GB/T14048.11 &quot;Low voltage switchgear and control equipment - Part 6: Multifunctional electrical appliances - Part 1: Automatic transfer switching devices&quot;, equivalent to IEC60947-6-1:1998 &quot;Low voltage switchgear and control equipment - Part 6: Automatic transfer switching devices&quot;, and complies with &quot;Code for Fire Protection of Tall Buildings&quot;, &quot;Code for Fire Protection Design of Buildings&quot;, &quot;Guidelines for Emergency Lighting Design&quot;, &quot;Code for Electrical Design of Civil Buildings&quot;, etc. Widely used in important places such as hospitals, shopping malls, banks, chemical plants, high-rise buildings, military facilities, fire protection, etc. that do not allow power outages&lt;BR&gt;&lt;BR&gt;TIQ1 series dual power automatic transfer switch&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]TIQ2 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/17496.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:15</pubDate>
           <comments></comments>
           <description>The TIQ2 series dual power automatic transfer switch is a new generation PC level automatic transfer switch designed and produced in accordance with the GB/T 14048.11 standard.&lt;BR&gt;&lt;BR&gt;The product has strong environmental adaptability and high reliability.&lt;BR&gt;Building block structure, small size, half the volume of the same CB grade ATSE.&lt;BR&gt;Can be installed vertically or horizontally.&lt;BR&gt;The main contact structure is interlocked with itself, which will not cause the phenomenon of simultaneously connecting two power sources.&lt;BR&gt;The operating mechanism is a single coil bidirectional operation, with a simple mechanism and fast conversion speed.&lt;BR&gt;The main contact has a large switching capacity and can be switched with 6In. It can also switch under different phase sequences of two power sources.&lt;BR&gt;Equipped with user terminal blocks and indicator lights, it can display the status of the power supply and the closing position of the automatic transfer switch.&lt;BR&gt;The intelligent real-time online monitoring of the controller can simultaneously monitor six phases (two power sources).&lt;BR&gt;The system parameters and functions (undervoltage, overvoltage, delay, etc.) can be set and changed on-site through the Chinese LCD menu, and displayed on the LCD screen.&lt;BR&gt;&lt;BR&gt;The TIQ2 series dual power automatic transfer switch complies with GB/T14048.11 &quot;Low voltage switchgear and control equipment - Part 6: Multifunctional appliances - Part 1: Automatic transfer switch&quot;, equivalent to IEC60947-6-1 &quot;Low voltage switchgear and control equipment - Part 6- Part 1: Automatic transfer switch&quot;, GB 50245-95 &quot;Fire protection code for high-rise civil buildings&quot;, GBJ 16-87 &quot;Code for fire protection design of buildings&quot;, JGJ/T 16-92 &quot;Code for electrical design of civil buildings&quot;, etc. Widely used in important places such as hospitals, shopping malls, banks, chemical plants, high-rise buildings, military facilities, fire protection, etc. where power outages are not allowed.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]TIQ3 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/17495.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:36:06</pubDate>
           <comments></comments>
           <description>The TIQ3 series automatic transfer switch is suitable for important power supply systems with AC 50Hz, rated working voltage of 400V, electrical grade of CB, and rated current up to 63A, used for the conversion of two power sources.&lt;BR&gt;&lt;BR&gt;ATSE has the function of automatic switching between undervoltage and phase failure to ensure the reliable operation of the distribution system. Its characteristics are:&lt;BR&gt;Equipped with dual electrical and mechanical interlocking devices to ensure reliable operation of the dual power supply.&lt;BR&gt;It has protection functions such as undervoltage, phase failure, and prevention of secondary reclosing&lt;BR&gt;The switch conversion is driven by a motor, which ensures reliable and smooth switching, energy saving, noise free, impact free, and anti-interference&lt;BR&gt;The safe and perfect TCL circuit breaker has precise thermal magnetic protection, complete performance, and reliability for executing circuit breakers&lt;BR&gt;The power conversion delay time and return delay time are visually easy and externally adjustable&lt;BR&gt;Product panel power status indication or lead out indication for easy user observation on the switchgear panel&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HSQ6 series automatic transfer switch electrical appliances </title>
           <link>http://www.91way.com/info_en/16101.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:58</pubDate>
           <comments></comments>
           <description>HSQ6 series automatic transfer switch electrical details:&lt;BR&gt;&lt;BR&gt;100A¡¢200A¡¢400A¡¢&lt;BR&gt;PC level&lt;BR&gt;Single blade double throw structure, self interlocking&lt;BR&gt;Fast conversion speed&lt;BR&gt;Switching large capacity&lt;BR&gt;High detection accuracy, easy to use and adjust&lt;BR&gt;&lt;BR&gt;HSQ6 series automatic transfer switch electrical appliance&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HSQ1 series automatic transfer switch electrical appliances </title>
           <link>http://www.91way.com/info_en/16100.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:49</pubDate>
           <comments></comments>
           <description>HSQ1 series automatic transfer switch electrical details:&lt;BR&gt;&lt;BR&gt;It has overload and short circuit protection functions and is a CB level ATSE&lt;BR&gt;Having a middle position for simultaneously disconnecting two circuit breakers, facilitating maintenance of lower level lines&lt;BR&gt;Test both power sources to ensure that the load receives a power supply that meets the usage requirements.&lt;BR&gt;Multiple specifications of electronic controllers are available to meet users' functional requirements for different usage scenarios&lt;BR&gt;The secondary circuit has been fully connected before leaving the factory, making it easy to install and use&lt;BR&gt;&lt;BR&gt;Types of HSQ1 series automatic transfer switch electrical appliances:&lt;BR&gt;HSQ1j integrated type&lt;BR&gt;HSQ1y Simplified Type&lt;BR&gt;HSQ1 Split Grid - Grid Type&lt;BR&gt;HSQ1 Split Grid - Generator Model&lt;BR&gt;Main circuit frame current: 63, 125, 160, 250, 400, 630, 800&lt;BR&gt;(Using HSM8 terminal appliances and HSM1 series molded case circuit breakers)&lt;BR&gt;1000, 2000, 3200, 4000, 6300 (using HSW1 intelligent universal circuit breaker)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]XHTQ1 series automatic transfer switch electrical appliances </title>
           <link>http://www.91way.com/info_en/16089.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:41</pubDate>
           <comments></comments>
           <description>Product details:&lt;BR&gt;Equipped with overload and short circuit protection functions, it is a CB level ATSE&lt;BR&gt;Having a middle position for simultaneously disconnecting two circuit breakers, facilitating maintenance of lower level lines&lt;BR&gt;Test both power sources to ensure that the load receives a power supply that meets the usage requirements. &amp;nbsp;&lt;BR&gt;Multiple specifications of electronic controllers are available to meet users' functional requirements for different usage scenarios&lt;BR&gt;The secondary circuit has been fully connected before leaving the factory, making it easy to install and use&lt;BR&gt;&lt;BR&gt;Type:&lt;BR&gt;XHTQ1j integrated type&lt;BR&gt;XHTQ1y Simple Type&lt;BR&gt;XHTQ1 Split Grid - Grid Type&lt;BR&gt;XHTQ1 Split Grid - Generator Model&lt;BR&gt;Main circuit frame current: 63, 125, 160, 250, 400, 630, 800&lt;BR&gt;(Using HSM8 terminal appliances and HSM1 series molded case circuit breakers)&lt;BR&gt;1000, 2000, 3200, 4000, 6300 (using HSW1 intelligent universal circuit breaker)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HQ6 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/13282.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:32</pubDate>
           <comments></comments>
           <description>HQ6 series automatic transfer switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HQ5 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/13281.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:24</pubDate>
           <comments></comments>
           <description>HQ5 series automatic transfer switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]BQ2 Series Dual Power Switching Device </title>
           <link>http://www.91way.com/info_en/6242.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:15</pubDate>
           <comments></comments>
           <description>Detailed information&lt;BR&gt;The BQ2 series dual power switching device uses two motors to operate two plastic shell circuit breakers respectively to achieve the conversion between power sources. It is a dual power automatic switching product with complete performance, safety and reliability, and high degree of automation.&lt;BR&gt;&lt;BR&gt;Performance Description of BQ2 Series Dual Power Switching Device&lt;BR&gt;1. It can be divided into three types: self restoration (R), self restoration without self restoration (S), and grid generation (F)&lt;BR&gt;2. Easy to operate, safe and reliable.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FDQ2A Intelligent Dual Power Switching Device </title>
           <link>http://www.91way.com/info_en/6241.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:35:06</pubDate>
           <comments></comments>
           <description>The FDQ2A intelligent dual power switch device uses one motor to operate two circuit breakers to achieve the conversion between power sources. It is a type of cabinet with complete performance, safety and reliability, simple structure, ultra-low height, and easy to install as a whole.&lt;BR&gt;&lt;BR&gt;Performance Description of FDQ2A Intelligent Dual Power Switching Device&lt;BR&gt;1. It can be divided into three types: self restoration (R), self restoration without self restoration (S), and grid generation (F);&lt;BR&gt;2. Adopting an integrated installation mechanism, low height, safe and reliable.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FDQ2B type dual power switching device </title>
           <link>http://www.91way.com/info_en/6240.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:57</pubDate>
           <comments></comments>
           <description>FDQ2B is an intelligent dual power switching device developed in FDQ2A. The controller is controlled by a microcomputer and is a remote control operation device that can communicate with the computer.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FDQ2 Dual power switching device </title>
           <link>http://www.91way.com/info_en/6239.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:49</pubDate>
           <comments></comments>
           <description>The FDQ2 dual power switching device uses one motor to operate two circuit breakers to achieve the conversion between power sources. It is a type of cabinet with complete performance, safety and reliability, simple structure, ultra-low height, and easy to install as a whole.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FDQ21 type dual power switch </title>
           <link>http://www.91way.com/info_en/6238.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:40</pubDate>
           <comments></comments>
           <description>FDQ21 dual power switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]FZQ1 series dual power switch </title>
           <link>http://www.91way.com/info_en/6237.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:32</pubDate>
           <comments></comments>
           <description>The FZQ1 series dual power switch uses a motor to operate the upper and lower load switches to achieve the conversion between power sources. It is a dual power automatic switching product with complete performance, safety and reliability, simple structure, and easy installation with the cabinet.&lt;BR&gt;&lt;BR&gt;performance description&lt;BR&gt;1. Adopting a modular structure, with a small volume and easy installation;&lt;BR&gt;2. Each position is equipped with a safety padlock device;&lt;BR&gt;3. Having reliable electrical and mechanical interlocking;&lt;BR&gt;4. Manual operation with clutch device, low operating force.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]GSA6 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/5130.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:23</pubDate>
           <comments></comments>
           <description>GSA6 series automatic transfer switch&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HYQ2 Dual power automatic switch </title>
           <link>http://www.91way.com/info_en/4964.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:15</pubDate>
           <comments></comments>
           <description>The HYQ2 series dual power automatic switching device (hereinafter referred to as the device) is a supporting product specially developed, designed and produced for the HYM1 series plastic shell circuit breaker. It is suitable for two power sources (common power source and backup power source) with AC 50Hz and rated voltage of 690V and below. It switches between power sources when one power source is abnormal, protecting the reliability and safety of power supply. This product complies with the IEC947-6-1 (1989) standard for automatic transfer switching devices.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;Model/Size&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;W1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;3P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;
&lt;DIV align=center&gt;4P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;3P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;4P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-63&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and forty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-160&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and forty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-225&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and forty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-630&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ&lt;SUP&gt;one&lt;/SUP&gt;&lt;SUB&gt;two&lt;/SUB&gt;-800&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;seven hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-nine&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HYQ2 Dual Power Automatic Switching Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HYQ30 Dual power automatic switch </title>
           <link>http://www.91way.com/info_en/4963.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:34:06</pubDate>
           <comments></comments>
           <description>HYQ30 Dual Power Automatic Switching Switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=&quot;19%&quot;&gt;
&lt;DIV align=center&gt;Model/Size&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;L1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;W1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3P/4P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3P/4P&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventeen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30-225&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30-400&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30-630(800)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;720/830&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;700/810&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and eighty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30M-100&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and seventeen&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYQ30M-225&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and forty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HYQ30 Dual Power Automatic Switching Switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HYQ30PW-63 Dual power automatic switch </title>
           <link>http://www.91way.com/info_en/4962.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:58</pubDate>
           <comments></comments>
           <description>The economical HYQ30PW-63 (terminal) automatic power switch (hereinafter referred to as A.T.S) is an electrical device specifically designed for terminal dual power switching, following the HYQ30 series automatic power switch produced by our factory. It is suitable for a one main and one backup power switching system, and is used as the main power supply location for fire protection, hospitals, shopping malls, military engineering, high-rise buildings, etc. where power outages are not allowed. It complies with GB/T14048.11-2002 &quot;Low voltage switchgear and control equipment - Part 6: Automatic transfer switchgear&quot;, &quot;Fire protection code for high-rise civil buildings&quot;, &quot;Building design code&quot;, &quot;Guidelines for emergency lighting design&quot;, &quot;Code for electrical design of civil buildings&quot; and other specifications or standards.&lt;BR&gt;&lt;BR&gt;Technical parameters of HYQ30PW-63 dual power automatic switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 550px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=550 align=center&gt;
&lt;TBODY&gt;
&lt;TR width=&quot;None&quot;&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;M&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;M1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;H1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C45&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;295(324)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;C65 type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;255(295)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty-two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HYQ30PW-63 Dual Power Automatic Switching Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HYCQ1 Dual power conversion switch </title>
           <link>http://www.91way.com/info_en/4961.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:49</pubDate>
           <comments></comments>
           <description>HYCQ1 automatic transfer switch integrates switch and logic control, without the need for an external controller. The automatic transfer switch that truly realizes mechatronics integration has functions such as voltage detection, frequency detection, communication interface, electrical and mechanical interlocking, and can achieve automatic, electric remote, and emergency manual control. The operation is managed by the logic control board using various logic commands to control the operation actions of the motor and gearbox. The motor drives the switch spring to store energy, and the instantaneous release of the acceleration mechanism quickly connects and disconnects the circuit or performs circuit conversion. Safety isolation is achieved through obvious visible states, greatly improving the performance of various electrical and mechanical devices. Switches below 100A are designed with a metal casing, which is compact and sturdy. For switches above 125A, the control part is made of metal shell, and the switch part is made of glass fiber unsaturated polyester resin shell, which has strong dielectric properties, protective ability, and reliable operational safety. The switch is suitable for automatic conversion between the main power supply and backup power supply of the power supply system, or automatic conversion and complete isolation of two load devices. The switch manufacturing is beautiful, novel, simple, small in size, and fully functional, making it the best choice for similar products.&lt;BR&gt;&lt;BR&gt;Technical parameters of HYCQ1 dual power conversion switch&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=157&gt;
&lt;DIV align=center&gt;specification&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=18&gt;
&lt;DIV align=center&gt;External dimensions and installation dimensions&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;HYCQ1-16-100A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;a&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;b&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;c&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;d&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;a1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;a2&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;d1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;e&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;e1&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;f&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;g&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;i&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;j&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;l&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;m&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;n&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;§æ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;§æ£±&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16A-32A/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;16A-32A/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40A-63A/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40A-63A/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80A-100A/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and eighteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80A-100A/4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;one hundred and twenty-eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;two hundred and seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;sixty-two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=15&gt;
&lt;DIV align=center&gt;seven&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;seventeen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;fifty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=27&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=25&gt;
&lt;DIV align=center&gt;six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=44&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;HYCQ1 Dual Power Conversion Switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HYCQ30 Dual power conversion switch </title>
           <link>http://www.91way.com/info_en/4960.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:40</pubDate>
           <comments></comments>
           <description>The HYCQ30 dual power conversion switch adopts a high-speed embedded microcontroller system as the control core, electromagnetic compatibility design, fast switching speed, strong anti-interference ability, and long-term stable and reliable operation. The HYCQ30 dual power automatic transfer switch is suitable for two power supply systems with AC 50/60HZ, rated voltage below 400V, and rated current below 1250A. It can achieve automatic transfer between the common power supply (N) and the backup power supply (R) (or be set to manual transfer). This product is suitable for special and Class 1 power systems, high-rise buildings, residential areas, military facilities, hospitals, airports, docks, shopping malls, communication, fire protection, metallurgy, chemical industry, textiles, petroleum, coal mines and other important places that do not allow power outages.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]DTSQ2 Intelligent dual power automatic switching device </title>
           <link>http://www.91way.com/info_en/4648.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:32</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application&lt;BR&gt;The switch is suitable for dual power supply switches with a frequency of 50/60Hz, rated voltage below 1140, and rated current below 5000A. It can achieve automatic or manual switching between the common power supply (N) and the backup power supply (R). The main and backup power sources can be the power grid, self starting generator sets, batteries, etc. The main and backup power sources are determined by the user. Enable dual power customers to achieve unmanned operation. This switch is suitable for special or first level load users specified by the state, such as high-rise buildings, postal and telecommunications, coal mining ships, industrial assembly lines, medical and health care, military facilities, airports, fire protection, metallurgy, chemical industry, textiles, petroleum and other important places that do not allow power outages.&lt;BR&gt;&lt;BR&gt;Normal working conditions&lt;BR&gt;The ambient air temperature ranges from -25 ¡æ to+40 ¡æ, with an average of no more than+35 ¡æ over 24 hours; At a maximum temperature of+40 ¡æ, the relative humidity should not exceed 50%. Higher relative humidity is allowed at lower temperatures, such as 90% at+20 ¡æ, but condensation may occur due to temperature changes. &amp;nbsp;&lt;BR&gt;The altitude of the installation location shall not exceed 2000m. It is classified as Class IV. The inclination angle shall not exceed &#177; 23 &#176;. The pollution level is level 3. &amp;nbsp;&lt;BR&gt;If the above conditions cannot be met, the order should be negotiated with the manufacturer. When this switch is used in offshore, petroleum, and nuclear power plants, a separate technical agreement should be signed. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Model and meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161747616.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 514px; HEIGHT: 247px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Model Description&quot; src=&quot;/uploadfiles/200903/200938161747616.gif&quot; width=514 height=247&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The DTSQ2 ATS, as the main and backup dual power automatic switching switch, adopts electromagnetic drive and electrical mechanical interlocking mechanism. The main circuit contacts are static and dynamic structures, and the dynamic contacts are designed in a V-shape. To avoid long-term electrification of the electromagnetic coil, electric closing and mechanical holding are adopted, and the control power supply is drawn from the main and backup current AC 220V (without the need for additional control current). Due to its superior structural characteristics, accidents will not occur when the main and backup power supplies are connected at the same time. The switch has electrical or mechanical closing indication, and can also provide customers with normally open and normally closed passive auxiliary contacts for other purposes. The DTSQ A-T-S switching time is adjustable from 1 to 30 seconds (usually 3 seconds when leaving the factory). If you need a longer time, please contact the manufacturer.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/20093816181480.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 544px; HEIGHT: 201px&quot; border=0 hspace=0 alt=&quot;Outline drawing of DTSQ2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200903/20093816181480.gif&quot; width=544 height=201&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Model specifications and technical parameters&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161835897.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 589px; HEIGHT: 480px&quot; border=0 hspace=0 alt=&quot;Technical parameters of DTSQ2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200903/200938161835897.gif&quot; width=589 height=480&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;installation diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162039683.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 552px; HEIGHT: 225px&quot; border=0 hspace=0 alt=&quot;Dimensions of DTSQ2 Intelligent Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200903/200938162039683.gif&quot; width=552 height=225&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162059449.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 494px; HEIGHT: 400px&quot; border=0 hspace=0 alt=&quot;Wiring Layout of DTSQ2 Intelligent Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200903/200938162059449.gif&quot; width=494 height=400&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Switch body, external dimensions, installation dimensions&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/20093816221882.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 565px; HEIGHT: 191px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Dimensions 1&quot; src=&quot;/uploadfiles/200903/20093816221882.gif&quot; width=565 height=191&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162215584.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 558px; HEIGHT: 452px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Dimensions 2&quot; src=&quot;/uploadfiles/200903/200938162215584.gif&quot; width=558 height=452&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162322726.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 564px; HEIGHT: 307px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Dimensions 3&quot; src=&quot;/uploadfiles/200903/200938162322726.gif&quot; width=564 height=307&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162337946.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 558px; HEIGHT: 376px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Dimensions 4&quot; src=&quot;/uploadfiles/200903/200938162337946.gif&quot; width=558 height=376&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162353550.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 561px; HEIGHT: 371px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Dimensions 5&quot; src=&quot;/uploadfiles/200903/200938162353550.gif&quot; width=561 height=371&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Model specifications and technical parameters&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938162415840.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 550px; HEIGHT: 233px&quot; border=0 hspace=0 alt=&quot;DTSQ2 Intelligent Dual Power Automatic Switching Device Wiring Diagram&quot; src=&quot;/uploadfiles/200903/200938162415840.gif&quot; width=550 height=233&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Fault analysis and troubleshooting&lt;BR&gt;After turning on, there is no response. After pressing the command button, the electric operating mechanism does not move. Please check the power wiring of the switch and the connection of the special cable. The three-phase power supply and neutral wire must be properly connected. After power on, although there is voltage in each phase, the panel shows undervoltage. Please check if the switch power supply is connected properly, if there is a phase loss phenomenon, and if the fuse on the body is blown due to the high current of the electric operating mechanism. Replace it with a suitable fuse tube and try again. &amp;nbsp;&lt;BR&gt;Frequent burning of fuse tubes, please check if the electric operating mechanism is stuck and adjust it appropriately before testing. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;Precautions for use and maintenance&lt;BR&gt;&lt;BR&gt;The incoming and outgoing wires of the switch should be wired according to the markings. If a 3-pole switch is used, the neutral wires (NN, RN) of the main and backup power supplies cannot be connected incorrectly. Otherwise, it will affect usage.&lt;BR&gt;&lt;BR&gt;The bottom plate of the switch should be reliably grounded to ensure power supply and safe use.&lt;BR&gt;&lt;BR&gt;Mechanical interlock debugging, rotate the switch handle 2 in the direction indicated on the panel. At this time, the common power supply (N) is closed. Then follow Figure 1-3, with the main and backup power sources in the disconnected position. Then press Figure 1-4 (do not release) and rotate the switch handle Z in the direction indicated on the panel. At this point, the backup power supply (R) of the switch will be turned on.&lt;BR&gt;Neither the main nor backup power sources can be turned on when the other power source is turned on. You must first follow Figure 1-3 to select one of the main and backup power sources for switching on again.&lt;BR&gt;&lt;BR&gt;This switch also has a function of &quot;double disconnection&quot; (i.e. both the main and backup power supplies are in the disconnected position). This function is mainly used when the load is overloaded or short circuited.&lt;BR&gt;Customers should specify when placing orders, otherwise manufacture according to standard enterprise specifications (i.e. excluding the above functions).&lt;BR&gt;&lt;BR&gt;Insert the dedicated plug of the intelligent controller into the dedicated socket of the switch.&lt;BR&gt;&lt;BR&gt;Check whether the contact parts of each electrical appliance are reliable, tightened, and whether the fuses are intact.&lt;BR&gt;&lt;BR&gt;After the above inspection and debugging, the system can be put into use. Suggest setting the work status to &quot;Common (N) Automatic&quot;. Press the power switch again and set the switching time as needed&lt;BR&gt;&lt;BR&gt;Precautions for use and maintenance&lt;BR&gt;This intelligent system should be regularly inspected and maintained according to the selected switch requirements. The intelligent controller is maintenance free under normal usage conditions. &amp;nbsp;&lt;BR&gt;Long term use of this intelligent system should pay attention to moisture and dust prevention. Before use, it should be debugged according to the above content before being put into operation. &amp;nbsp;&lt;BR&gt;The warranty period of this intelligent system is one year, during which the &quot;three guarantees&quot; are implemented, namely warranty, replacement, and return. Outside the warranty period, our company can provide lifelong maintenance, and the cost will be borne by the user. &amp;nbsp;&lt;BR&gt;To enable users to quickly master the maintenance and operation of this intelligent system, our company can provide free training for professional maintenance and operation personnel for customers. &amp;nbsp;&lt;BR&gt;When placing an order, the switch and operation mode should be selected based on the meaning and capacity of the model. &amp;nbsp;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]DTSQ1 series intelligent dual power automatic switching system </title>
           <link>http://www.91way.com/info_en/4647.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;DTSQ1 series intelligent dual power automatic switching system&lt;BR&gt;&lt;BR&gt;Overview&lt;BR&gt;With the rapid development of technology today, power system equipment is gradually moving towards centralized monitoring and intelligence, that is, weak current (electronic) control of strong current. Our company has developed a new generation of intelligent dual power automatic switching system based on advanced foreign technology and the actual needs of domestic electricity users. It is based on the latest microcomputer control system, with electromagnetic compatibility design, strong anti-interference ability, stable and reliable long-term operation, and is equipped with a large backlit LCD display to form a good human-machine dialogue interface for users. The operation and warning are simple and highly intelligent, making it an ideal new type of electromechanical integrated dual power automatic switching system. This product adopts a microcomputer interface, with 254 controllable intelligent dual power supplies running simultaneously, greatly reducing manpower, material resources, and financial resources. At the same time, it has opened up a new era of intelligent and networked development for dual power automatic switching systems, and is also an updated product of similar products in China. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;Scope of application&lt;BR&gt;The DTSQ1 series intelligent dual power automatic switching system is suitable for dual power supply systems with AC 50/60Hz, rated voltage below 1000V, and rated current below 2000A. It can achieve automatic switching (or manual switching) between the common power supply (N) and the backup power supply (R), allowing dual power supply users to achieve unmanned substations. This product is suitable for special and Class I power systems, high-rise buildings, residential areas, military facilities, hospitals, airports, docks, shopping malls, communication, fire protection, metallurgy, chemical industry, textiles, petroleum, coal mines and other important places that do not allow power outages.&lt;BR&gt;&lt;BR&gt;Normal working conditions&lt;BR&gt;The ambient air temperature is between -25 &#176; C and+40 &#176; C, and the average value over 24 hours does not exceed+35 &#176; C&lt;BR&gt;&lt;BR&gt;Atmospheric conditions: The air is clean, with a relative humidity not exceeding 50% at a maximum temperature of+40 &#176; C. Higher relative humidity is allowed at lower temperatures, such as 90% at+20 &#176; C, but it should be considered that condensation may occur due to humidity changes.&lt;BR&gt;&lt;BR&gt;The installation location shall not exceed an altitude of 2000 meters and shall be used indoors.&lt;BR&gt;&lt;BR&gt;This product should be installed in a location where there is no severe vibration or impact, and where electrical components are not subjected to undue corrosion.&lt;BR&gt;&lt;BR&gt;If the above conditions cannot be met, it should be resolved through negotiation between the user and the manufacturer.&lt;BR&gt;&lt;BR&gt;When this product is used for offshore oil and nuclear power plants, a separate technical agreement should be signed. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161116737.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 477px; HEIGHT: 234px&quot; border=0 hspace=0 alt=&quot;Model Description of DTSQ1 Series Intelligent Dual Power Automatic Switching System&quot; src=&quot;/uploadfiles/200903/200938161116737.gif&quot; width=477 height=234&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Structural characteristics&lt;BR&gt;The DTSQ1 intelligent dual power automatic switching system (hereinafter referred to as the intelligent system) consists of two main parts: the device body and the intelligent automatic controller. &amp;nbsp;&lt;BR&gt;1. The device body consists of two circuit breakers with motor operating mechanisms (model specifications refer to the technical parameter terms) and accessories (auxiliary alarm contacts, etc.), mechanical interlocking mechanism, electrical interlocking, fuses, wiring terminals, etc. All components are installed on a metal plate.&lt;BR&gt;2. The intelligent automatic controller is composed of a novel microcontroller and various output modules. &amp;nbsp;&amp;nbsp;&lt;BR&gt;The two are connected through a dedicated aviation plug interface and a shielded cable with a length not exceeding 2 meters to form an intelligent control system. The intelligent system controls the power supply voltage to be 220V, 50/60Hz. &amp;nbsp;&lt;BR&gt;This intelligent system has dual mechanical and electrical interlocking protection functions, providing a safe and reliable guarantee for your power supply. &amp;nbsp;&amp;nbsp;&lt;BR&gt;This intelligent system can automatically switch between dual power supply of three-phase three wire and three-phase four wire. &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;Performance of DTSQ1 series intelligent dual power automatic switching system&lt;BR&gt;&lt;BR&gt;One Working principle of intelligent system&lt;BR&gt;The controller simultaneously detects two voltages, and determines overvoltage for power voltages higher than 110% (adjustable) of the rated value and undervoltage (or loss) for power voltages lower than 85% (adjustable) of the rated value. The microcomputer control circuit logically judges the above detection results, and the processing results are sent to the electric operating mechanism through a delay (adjustable) circuit to drive the corresponding instructions to open or close the circuit. The above detection results can be displayed on the LCD screen of the intelligent automatic controller panel, or connected to the computer through a serial port and controlled by software for users to find the cause, so that users can repair the faulty line in the shortest time and restore the dual power supply to its original state.&lt;BR&gt;&lt;BR&gt;II Intelligent automatic controllers are divided into three types according to their control functions&lt;BR&gt;Self investment and self recovery (R) are applicable to power grids. The intelligent automatic controller automatically switches between two power sources, namely the common power source and the backup power source. When the common power source fails or is abnormal (overvoltage, undervoltage, undervoltage or phase loss of any phase voltage), it automatically switches to the backup power source after a set (adjustable) delay time. When the common power source returns to normal, it automatically returns to the common power source after a set (adjustable) delay time. When the backup power source fails or is abnormal (overvoltage, undervoltage, undervoltage or phase loss of any phase voltage), the controller issues an alarm for the common or backup power source. &amp;nbsp;&lt;BR&gt;Self investment without self recovery (S) is applicable to power grids. The automatic controller that automatically switches between two power sources (i.e. the common power source and the backup power source) without self recovery. When any power source experiences an abnormality (overvoltage, undervoltage, or phase loss in any phase voltage), it will automatically switch to another normal power source for recovery after a set delay. &amp;nbsp;&lt;BR&gt;Grid and Power Generation (F) [When used in a grid and power generation system, the conversion time should be set to 15 seconds] The automatic controller for grid and power generation automatically switches between the two power sources. When the grid voltage is below 85% of the rated voltage, a power generation delay command is issued (output through a set of normally open and normally closed contacts). When the generated voltage reaches 85% of the rated voltage, the load circuit is first disconnected from the power grid, and the secondary load is removed (output through another set of normally open and normally closed contacts) through unloading instructions. Then, the generated power supply is connected with a delay through conversion. After the power grid returns to normal (reaching 85% of the rated voltage or above), the intelligent controller will automatically disconnect the load circuit from the power source and switch to power supply from the grid. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;III When the commonly used power supply is abnormal, the microcomputer will detect whether the working state (manual, automatic, self recovery, non self recovery, etc.) and the pre-set backup power supply are normal to decide whether to switch. The startup backup power supply will be used, and the system load will be powered by the backup power supply. &amp;nbsp;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/200938161140876.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 633px; HEIGHT: 204px&quot; border=0 hspace=0 alt=&quot;Technical data of DTSQ1 series intelligent dual power automatic switching system&quot; src=&quot;/uploadfiles/200903/200938161140876.gif&quot; width=633 height=204&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;4 Dual power supply dual split state:&lt;BR&gt;When the system is loaded in a dual split state, regardless of whether the two power supplies are normal or the preset states of &quot;manual&quot; and &quot;automatic&quot;, the system still remains in a dual split state. Only after operating the keyboard (manual) (automatic), will the system be switched to a non dual split state (manual - common - standby or automatic - self recovery - no self recovery), and the load will be powered and processed as described above. &amp;nbsp;&lt;BR&gt;Five Protection function:&lt;BR&gt;Overload and short circuit protection for phase failure, open circuit protection for voltage loss, and undervoltage protection&lt;BR&gt;VI Equipped with automatic switching time adjustable from 1 second to 30 seconds&lt;BR&gt;7 High performance microcontroller program control, strong anti-interference ability, high protection accuracy&lt;BR&gt;8 It has the advantages of small size, high stability, and reliable continuous operation&lt;BR&gt;Nine Equipped with a central microcomputer controlled communication interface&lt;BR&gt;Ten Silent operation, energy-saving and consumption reducing, in compliance with national green electrical product standards&lt;BR&gt;Eleven Equipped with remote control of fire signal output &amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;BR&gt;The specifications and technical parameters are shown in the table&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/20093816128890.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 623px; HEIGHT: 335px&quot; border=0 hspace=0 alt=&quot;Technical parameters of DTSQ1 series intelligent dual power automatic switching system&quot; src=&quot;/uploadfiles/200903/20093816128890.gif&quot; width=623 height=335&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Installation diagram and wiring diagram&lt;BR&gt;Intelligent controller dimensions, installation dimensions, and opening dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/20093816134650.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 586px; HEIGHT: 243px&quot; border=0 hspace=0 alt=&quot;DTSQ1 series intelligent dual power automatic switching system external dimensions&quot; src=&quot;/uploadfiles/200903/20093816134650.gif&quot; width=586 height=243&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions of split type intelligent dual power automatic switching device&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161321836.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 540px; HEIGHT: 181px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of DTSQ1 series intelligent dual power automatic switching system&quot; src=&quot;/uploadfiles/200903/200938161321836.gif&quot; width=540 height=181&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions of DTSQ1A split type intelligent dual power automatic switching device&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161342941.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 536px; HEIGHT: 282px&quot; border=0 hspace=0 alt=&quot;DTSQ1 series intelligent dual power automatic switching system installation size table 1&quot; src=&quot;/uploadfiles/200903/200938161342941.gif&quot; width=536 height=282&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions of DTSQ1B integrated intelligent dual power automatic switching device&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/20093816141688.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 544px; HEIGHT: 288px&quot; border=0 hspace=0 alt=&quot;DTSQ1 series intelligent dual power automatic switching system installation size table 2&quot; src=&quot;/uploadfiles/200903/20093816141688.gif&quot; width=544 height=288&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Dimensions and installation dimensions of intelligent modular devices&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161432233.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 545px; HEIGHT: 407px&quot; border=0 hspace=0 alt=&quot;DTSQ1 series intelligent dual power automatic switching system installation size table 3&quot; src=&quot;/uploadfiles/200903/200938161432233.gif&quot; width=545 height=407&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Principle of wiring diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200903/200938161455920.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 529px; HEIGHT: 332px&quot; border=0 hspace=0 alt=&quot;DTSQ1 series intelligent dual power automatic switching system wiring diagram&quot; src=&quot;/uploadfiles/200903/200938161455920.gif&quot; width=529 height=332&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Intelligent Controller Panel Description&lt;BR&gt;1. NA, NB, NC are commonly used power indicators: lit up indicates normal operation, flashing indicates undervoltage or phase failure; RA, RB, and RC are backup power sources. &amp;nbsp;&lt;BR&gt;2. Press the auto button to select the auto reset or non auto reset function. Pressing the double key can disconnect the load from the common or backup power source.&lt;BR&gt;3. When the system malfunctions, the OA flashes and the alarm flashes while emitting an alarm sound. Pressing the button can terminate the alarm. If the fault still persists, the alarm will sound again 30 seconds later. &amp;nbsp;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/200938161528877.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 212px; HEIGHT: 186px&quot; border=0 hspace=0 alt=&quot;Outline drawing of DTSQ1 series intelligent dual power automatic switching system&quot; src=&quot;/uploadfiles/200903/200938161528877.gif&quot; width=212 height=186&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Panel Instructions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200903/200938161551726.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 547px; HEIGHT: 189px&quot; border=0 hspace=0 alt=&quot;Panel layout of DTSQ1 series intelligent dual power automatic switching system&quot; src=&quot;/uploadfiles/200903/200938161551726.gif&quot; width=547 height=189&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DTSQ1 series intelligent dual power automatic switching system&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HGQ2 Series Dual Power Automatic Switching Switch </title>
           <link>http://www.91way.com/info_en/3789.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:15</pubDate>
           <comments></comments>
           <description>Purpose:&lt;BR&gt;The HGQ2 series dual power automatic switch is suitable for two power supplies (common power supply and backup power supply or power generation power supply) with AC 50HZ, 690V and below. It automatically switches between power supplies in case of a failure of one power supply to ensure the reliability and safety of power supply.&lt;BR&gt;&lt;BR&gt;This product has two switching functions: self switching and self resetting, and self switching and non self resetting. It can simultaneously detect the three-phase power supply of two power sources in a three-phase four wire power grid. When any one of them experiences overvoltage or undervoltage (including phase loss), it will automatically switch from the abnormal power supply to the normal power supply; The product used in the power generation system of the power grid also has power generation and unloading signals, making it a dual power automatic switching product with complete performance, safety and reliability, automation level, and wide range of applications. This product complies with the IEC60947-6-1 (1989) standard for automatic transfer switch circuit breakers.&lt;BR&gt;&lt;BR&gt;HGQ2 series dual power automatic switch model and meaning:
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/200852718433642.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 416px&quot; border=0 hspace=0 alt=&quot;HGQ2 Series Dual Power Automatic Switching Switch Model Description&quot; src=&quot;/uploadfiles/200805/200852718433642.jpg&quot; width=680 height=416&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008527184356811.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 460px&quot; border=0 hspace=0 alt=&quot;Technical parameters of HGQ2 series dual power automatic switch&quot; src=&quot;/uploadfiles/200805/2008527184356811.jpg&quot; width=680 height=460&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;HGQ2 series dual power automatic switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]M-ATS3 Intelligent dual power automatic switching device </title>
           <link>http://www.91way.com/info_en/3451.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:33:06</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Model meaning&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851401053195.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 247px&quot; border=0 hspace=0 alt=&quot;Model Description of M-ATS3 Intelligent Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200805/200851401053195.gif&quot; width=500 height=247&gt;&lt;/A&gt;&lt;BR&gt;Specifications and Technical Parameters of M-ATS3 Intelligent Dual Power Automatic Switching Device&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851401120617.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 168px&quot; border=0 hspace=0 alt=&quot;Dimensions of M-ATS3 Intelligent Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200805/200851401120617.gif&quot; width=680 height=168&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851401130884.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 68px&quot; border=0 hspace=0 alt=&quot;Technical parameters of M-ATS3 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/200851401130884.gif&quot; width=680 height=68&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;M-ATS3 intelligent dual power automatic switching device&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]M-ATS2 Intelligent dual power automatic switching device </title>
           <link>http://www.91way.com/info_en/3450.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:57</pubDate>
           <comments></comments>
           <description>Overview of M-ATS2 Intelligent Dual Power Automatic Switching Device&lt;BR&gt;&lt;BR&gt;Good safety&lt;BR&gt;By adopting double row composite contacts, cross connection mechanism, micro motor pre energy storage, and microelectronic control technology, zero arcing (no arcing cover) is basically achieved&lt;BR&gt;Adopting reliable mechanical and electrical interlocking technology&lt;BR&gt;Adopting zero crossing technique (double division)&lt;BR&gt;It has obvious on/off position indication and padlock function, reliably achieving isolation between power supply and load&lt;BR&gt;High reliability, with a service life of over 8000 times&lt;BR&gt;Integrated electromechanical design, accurate, flexible, and reliable switch conversion&lt;BR&gt;Good electromagnetic compatibility, strong anti-interference ability, and no external interference&lt;BR&gt;High degree of automation&lt;BR&gt;Fully automatic type does not require any external control components&lt;BR&gt;Beautiful appearance, small size, and light weight&lt;BR&gt;&lt;BR&gt;The logic control board manages the operation of the motor and gearbox directly installed inside the switch with different logics to ensure the position of the switch.&lt;BR&gt;The motor is a chloroprene rubber insulated wet heat type motor equipped with a safety device that trips when the temperature exceeds 110 ¡æ and there is an overcurrent state. After the fault disappears, it will automatically start working, and the reversible reduction gear adopts spur gear.&lt;BR&gt;&lt;BR&gt;Installation dimensions of M-ATS2 intelligent dual power automatic switching device&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140238707.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 200px&quot; border=0 hspace=0 alt=&quot;Appearance and installation dimensions of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140238707.gif&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Main technical indicators of M-ATS2 intelligent dual power automatic switching device&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Agreed Civil Heating Power Supply I&lt;SUB&gt;th&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;63A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated insulation voltage U&lt;SUB&gt;one&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;750V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated impulse withstand voltage U&lt;SUB&gt;imp&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;8KV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working voltage U&lt;SUB&gt;e&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC440V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working current I&lt;SUB&gt;e&lt;/SUB&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;20A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;40A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;63A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;80A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;load characteristic&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC31A¡¢AC35A¡¢AC33A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated connection capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10Ie&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated breaking capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;8Ie&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated limit short-circuit current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;100KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time withstand current IS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;7KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Convert time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.45S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Control power supply voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;AC220V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Motor energy consumption&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Start 300W, normal 55W&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Weight (Kg)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four point four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four point five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Terminal wiring diagram (without double division)&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140316177.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 140px&quot; border=0 hspace=0 alt=&quot;Wiring diagram of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140316177.gif&quot; width=680 height=140&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Note: HL1 and HL2 are indicators for incoming calls from the common power supply and backup power supply, respectively; HD1 and HD2 respectively indicate the activation of the common power supply and backup power supply; FU1 and FU2 are 2A fuses; 302~305 are switch terminals.&lt;BR&gt;&lt;BR&gt;Terminal wiring diagram (with double split)&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140338879.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 613px; HEIGHT: 365px&quot; border=0 hspace=0 alt=&quot;Contact diagram of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140338879.gif&quot; width=613 height=365&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;M-ATS2-100-1600A external installation dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008514048726.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;Installation dimensions of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/2008514048726.gif&quot; width=650 height=220&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140436565.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 150px&quot; border=0 hspace=0 alt=&quot;Technical parameters of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140436565.gif&quot; width=650 height=150&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;M-ATS2-2000A-3200A external installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/20085140458201.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 330px&quot; border=0 hspace=0 alt=&quot;Installation diagram of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140458201.gif&quot; width=680 height=330&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140528749.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 70px&quot; border=0 hspace=0 alt=&quot;Installation dimension table of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140528749.gif&quot; width=680 height=70&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;M-ATS2-100A-3200A Terminal Wiring Diagram&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140554805.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 446px; HEIGHT: 221px&quot; border=0 hspace=0 alt=&quot;Contact diagram 1 of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140554805.gif&quot; width=446 height=221&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140623770.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 209px&quot; border=0 hspace=0 alt=&quot;Contact diagram 2 of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140623770.gif&quot; width=500 height=209&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140712167.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 406px; HEIGHT: 253px&quot; border=0 hspace=0 alt=&quot;Contact diagram 3 of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140712167.gif&quot; width=406 height=253&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140729849.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 500px; HEIGHT: 248px&quot; border=0 hspace=0 alt=&quot;Contact diagram 4 of M-ATS2 intelligent dual power automatic switching device&quot; src=&quot;/uploadfiles/200805/20085140729849.gif&quot; width=500 height=248&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/20085140753920.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 180px&quot; border=0 hspace=0 alt=&quot;M-ATS2 Intelligent Dual Power Automatic Switching Device Contact Diagram 5&quot; src=&quot;/uploadfiles/200805/20085140753920.gif&quot; width=680 height=180&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;Fire control signal&lt;BR&gt;The switch has a normally open contact for external connection to provide users with fire control signals. When a fire occurs, the fire control center sends a control signal to enter intelligent control. At this time, the dual power supply body enters the open state and cuts off the power supply at the load end. When the fire signal is not released, regardless of whether it is in the &quot;manual&quot; or &quot;automatic&quot; state, the common and backup power supply execution switches of the automatic transfer switch cannot be closed. Only after the fire control signal is released, the switch automatically switches to normal power supply from the common power source.&lt;BR&gt;&lt;BR&gt;function&lt;BR&gt;&lt;BR&gt;Control function:&lt;BR&gt;The &quot;normally&quot; switch in the three status positions is closed, and the &quot;standby&quot; switch is open; The 'backup' switch is closed; The 'normally' switch is disconnected; Both switches are disconnected to the 0 position.&lt;BR&gt;Multiple operation modes: emergency manual operation, manual control operation, automatic control operation.&lt;BR&gt;The switch is controlled by a single-chip control device to achieve automatic operation function, and the reliable working voltage of the control motor of the main circuit is: the upper limit is 220 &#215; 115% V, the lower limit is 220 &#215; 75% V, and the frequency is 50HZ+10%.&lt;BR&gt;&lt;BR&gt;Detection and protection function:&lt;BR&gt;The working voltage of the various wiring terminals of the power supply is considered overvoltage when it reaches 115% of the rated working voltage; When the working voltage of the various wiring terminals of the power supply drops to 75% of the rated working voltage, it is considered undervoltage; If the working voltage of any phase terminal of the power supply drops to 75% or below of the rated working voltage, it is considered as voltage loss, which is abnormal. The common power supply and backup power supply are both part of the mains power supply system, and one power supply can be determined as the common power supply. When any phase of the common power supply circuit loses voltage, the switch will automatically switch to the backup power supply circuit after a delay of 3 seconds. When the common voltage circuit returns to normal, the switch will automatically switch to the common power supply circuit after a delay of seconds; The commonly used power supply circuit is the mains power supply, and the backup power supply circuit is the power supply system of the oil engine. When any phase of the commonly used power supply circuit loses voltage or all phases simultaneously experience overvoltage or undervoltage, the momentary switch will automatically switch to the disconnect position after a delay. At the same time, the control device will send a signal to start the oil engine. After the start is complete (i.e. no fault), the momentary switch will automatically switch to the backup circuit of the oil engine after a warm-up delay. When the backup power circuit of the oil engine is supplying power and the common power circuit returns to normal, after a delay of 3 seconds, the switch automatically switches to the common power circuit.&lt;BR&gt;When the backup power circuit of the oil engine is supplying power, if any phase loses voltage or all phases simultaneously experience overvoltage or undervoltage, and if the common power circuit returns to normal, the switch will automatically switch to the disconnected position after a delay of 3 seconds.&lt;BR&gt;When the switch is in the off position, as long as the common power circuit returns to normal and after a delay of 3 seconds, regardless of the state of the oil machine, the switch will automatically switch to the common power circuit first. When both the common power supply and the backup power supply fail, the switch should automatically switch to the disconnected position.&lt;BR&gt;When the common power supply and the backup power supply lose voltage or undervoltage to 220 &#215; 75% or below simultaneously, the switch fails and remains in its original position.&lt;BR&gt;Computer communication function:&lt;BR&gt;After connecting to the computer, this machine can directly monitor and control the conversion switch (please specify this function when ordering).&lt;BR&gt;&lt;BR&gt;Function annotation:&lt;BR&gt;Self investment and self recovery (R) are applicable to power grids. After the commonly used power supply returns to normal, it will automatically return to the commonly used power supply after a set (adjusted) delay time.&lt;BR&gt;Self investment without self recovery (S) is applicable to power grids. The automatic controller that automatically switches between two pairs of intermediate power sources (i.e., the common power source and the backup power source) without self restoration. When any power supply experiences an abnormality (overvoltage, undervoltage, or phase loss in any phase voltage), it will automatically switch to another power supply after a set delay. However, when the abnormal power supply returns to normal, it cannot automatically recover.&lt;BR&gt;When used in the power grid and power generation system, the self controller automatically switches between the power grid and the two power sources. When the grid voltage is below 85% of the rated voltage, a power generation command is issued through a power generation delay command (output as a set of normally closed contacts). When the generated voltage reaches 85% of the rated voltage, the load circuit is disconnected from the power grid first, and then the generated power supply is connected after a delay. After the power grid returns to normal (reaching 85% of the rated voltage or above), the intelligent controller will automatically disconnect the load circuit from the power source and switch to power supply from the grid&lt;BR&gt;&lt;BR&gt;Fire release device:&lt;BR&gt;DC24V is added, immediately cut off the two currents.&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]M-ATS1 series intelligent dual power automatic switching switch </title>
           <link>http://www.91way.com/info_en/3449.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:48</pubDate>
           <comments></comments>
           <description>M-ATS1 series intelligent dual power automatic switch&lt;BR&gt;&lt;BR&gt;Overview and Scope of Application&lt;BR&gt;With the rapid development of technology today, power system equipment is gradually moving towards centralized monitoring and intelligence, that is, weak current (electronic) control of weak current Our company has developed a new generation of intelligent dual power automatic switching system based on advanced foreign technology and the actual needs of domestic electricity users It is based on the latest microcomputer control system, designed for electromagnetic compatibility, and resistant to&lt;BR&gt;Strong interference, stable and reliable long-term operation, equipped with a large screen light LCD display, providing users with a good human-machine dialogue interface, easy operation and warning, and highly intelligent&lt;BR&gt;An ideal mechatronics integrated new dual power automatic switching system This product uses 254 computer-controlled intelligent dual power supplies to operate simultaneously, greatly reducing manpower, material resources, and financial resources At the same time, it has ushered in a new era of intelligent and networked development for dual power automatic switching systems, and is also an updated product of similar products in China&lt;BR&gt;&lt;BR&gt;Model and meaning&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008513235447659.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 650px; HEIGHT: 312px&quot; border=0 hspace=0 alt=&quot;Model Description of M-ATS1 Series Intelligent Dual Power Automatic Switching Switch&quot; src=&quot;/uploadfiles/200805/2008513235447659.jpg&quot; width=650 height=312&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Scope of application&lt;BR&gt;The M-ATS1 system intelligent dual power automatic switching system is suitable for dual power supply with AC 50Hz/60Hz, rated voltage below 1000V, and rated current below 2000A&lt;BR&gt;The electrical system can automatically switch between the common power supply (N) and the equipment power supply (R) (manual switching can also be set), enabling dual power supply users to achieve unmanned substations this&lt;BR&gt;The product is suitable for special categories, power systems, high-rise buildings, residential areas, military facilities, hospitals, airports, docks, shopping malls, communication, fire protection, metallurgy, chemical industry, textiles, petroleum, coal mines and other important places that do not allow power outages&lt;BR&gt;&lt;BR&gt;Normal working conditions&lt;BR&gt;1. The ambient air temperature ranges from -25 ¡æ to 40 ¡æ, and the average value over 24 hours does not exceed+35 ¡æ&lt;BR&gt;2. Atmospheric conditions: The air is clean, and the relative temperature does not exceed 50% at the highest temperature of+40 ¡æ. Higher relative temperatures are allowed at lower temperatures, such as 90% at+20 ¡æ, but condensation may occur due to temperature changes&lt;BR&gt;3. The installation location shall not exceed an altitude of 2000 meters and shall be used indoors&lt;BR&gt;4. This product should be installed in a location where there is no severe vibration or impact, and where electrical components are not subjected to undue corrosion&lt;BR&gt;If the above conditions cannot be met, the user manufacturer should negotiate and resolve the issue&lt;BR&gt;When this product is used in offshore oil and nuclear power plants, a separate technical agreement should be signed&lt;BR&gt;&lt;BR&gt;structural characteristics&lt;BR&gt;The M-ATS1 intelligent dual power automatic switching system (hereinafter referred to as the intelligent system) consists of two main parts: the device body and the intelligent automatic controller&lt;BR&gt;a. The device body consists of two circuit breakers with motor operating mechanisms (see technical parameter terms for model specifications) and accessories (auxiliary alarm contacts, etc.) with mechanical interlocking mechanisms and electrical interlocking&lt;BR&gt;Fuses and wiring terminals are composed of isosceles triangles, and all components are installed on a single piece of metal&lt;BR&gt;b. The intelligent automatic controller is composed of a novel microcontroller and various horizontal blocks such as outputs&lt;BR&gt;2. The two are connected through a dedicated aviation plug interface and a shielded cable with a length not exceeding 2 meters Form an intelligent control system that controls the power supply voltage to 220V, 50/60Hz&lt;BR&gt;3. This intelligent system has mechanical and electrical interlock protection functions, providing a safe and reliable guarantee for your power supply&lt;BR&gt;4. This intelligent system can automatically switch between dual power supply of three-phase three wire and three-phase four wire&lt;BR&gt;&lt;BR&gt;performance&lt;BR&gt;&lt;BR&gt;Working principle of intelligent system&lt;BR&gt;a. The controller simultaneously detects two voltages, and judges any voltage higher than 110% (adjustable) of the rated value as overvoltage, and any voltage lower than 85% (adjustable) of the rated value as undervoltage (or loss) voltage. The microcomputer control circuit makes logical judgments on the above detection results, and the processing results are sent to the electric operating mechanism through a delay (reliable) circuit to drive the corresponding instructions to open or close the circuit. The above detection results can be displayed on the LCD screen of the intelligent automatic controller panel, or connected to the computer through a serial port and controlled by software for the user to find the cause. The user can restore the fault line in a short time and restore the dual power supply to its original state&lt;BR&gt;&lt;BR&gt;Intelligent automatic controllers are divided into three types according to their control functions&lt;BR&gt;&lt;BR&gt;Self investment and self recovery (R) are applicable to power grids and power grids The intelligent automatic controller automatically switches between two power sources, namely the common power source and the backup power source. In normal state, the standby power source supplies power. When the common power source fails or is abnormal (overvoltage, undervoltage, undervoltage or undervoltage of any phase), it automatically switches to the backup power source for a set (adjustable) delay time. When the common power source returns to normal, the set (adjustable) delay time automatically returns to the common power source for power supply. When the backup power source fails or is abnormal (overvoltage, undervoltage, undervoltage or undervoltage of any phase), the controller triggers an alarm for the permanent or backup power source&lt;BR&gt;&lt;BR&gt;Specifications and Technical Parameters&lt;BR&gt;1. Self investment without self recovery (S) is applicable to power grids and power grids&lt;BR&gt;The automatic controller that automatically switches between two power sources (i.e. common power source and backup power source) without self recovery Any abnormality occurs in any power supply (overvoltage occurs in any phase voltage)&lt;BR&gt;When under voltage or phase loss occurs, it automatically switches to a normal power supply after a set delay, but cannot automatically recover when the abnormal power supply returns to normal&lt;BR&gt;When used in the power grid and power generation system, the conversion time should be set at 15 seconds. The automatic controller of the power grid and power generation automatically controls the two power sources of the power grid and power generation&lt;BR&gt;Switching, when the grid voltage is below 85% of the rated voltage, a power generation command is issued through a power generation delay command (output through a set of normally open and closed contacts) When the generated voltage reaches 85% of the rated voltage, the load circuit is first disconnected from the power grid, and the secondary load is unloaded (output through another set of normally open and closed contacts) through unloading instructions. Then, the generated power supply is connected with a delay through conversion After the power grid returns to normal (reaching 85% of the rated voltage or above), the intelligent controller will automatically disconnect the load circuit from the power source and switch to the power grid for power generation based on logical judgment&lt;BR&gt;When the commonly used power supply is abnormal, the microcomputer will detect the current preset working status (manual, automatic, self resetting, non self resetting) and whether the backup power supply is normal to decide whether to switch and start the backup&lt;BR&gt;Using power supply, the system load is powered by a backup power source&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 colSpan=2&gt;
&lt;DIV align=center&gt;Current power supply for the load&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;DIV align=center&gt;The current preset status of the system&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=112&gt;
&lt;DIV align=center&gt;Is the current power supply faulty and is the other set of power supplies functioning properly&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;Handling of power supply failures&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 colSpan=3&gt;
&lt;DIV align=center&gt;When the current backup power supply is normal, it will be detected and processed when there is power available again&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=14 colSpan=2&gt;
&lt;DIV align=center&gt;manual&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;automatic&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=63&gt;
&lt;DIV align=center&gt;Do not switch to&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;switch to&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;common&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;backup&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=33&gt;
&lt;DIV align=center&gt;common&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=31&gt;
&lt;DIV align=center&gt;backup&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=30&gt;
&lt;DIV align=center&gt;self-recovery&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=41&gt;
&lt;DIV align=center&gt;Not self recovering&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;common&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=39&gt;
&lt;DIV align=center&gt;backup&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=73&gt;
&lt;DIV align=center&gt;Is it commonly used normally&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=45&gt;
&lt;DIV align=center&gt;Do not switch&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=43&gt;
&lt;DIV align=center&gt;switch to&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=38&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2 width=51&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=6&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;&lt;/TD&gt;
&lt;TD height=18&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;&lt;/TD&gt;
&lt;TD height=14&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;normal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;abnormal&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡ñ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;1. Dual power supply with dual split state&lt;BR&gt;When the system load is in the dual split state, regardless of whether the two power supplies are normal or the preset states of &quot;manual&quot; and &quot;automatic&quot;, the system still protects in the dual split state Only after operating the keyboard (manual) (automatic), will the system be switched to a non dual split state (manual - common - standby or automatic - self recovery - no self recovery), and the load will be powered and processed as described above&lt;BR&gt;2. Protection function&lt;BR&gt;Overload and short circuit protection; Phase failure, open circuit protection; Voltage loss and undervoltage protection&lt;BR&gt;3. It has an automatic switching time that can be adjusted from 1 second to 30 seconds&lt;BR&gt;4. High performance microcontroller program control, strong anti-interference ability, high protection accuracy&lt;BR&gt;5. It has the advantages of small size, high stability, and reliable continuous operation&lt;BR&gt;6. Equipped with a central microcomputer control communication port&lt;BR&gt;7. Silent operation, energy-saving and consumption reducing, in compliance with national green electrical product standards&lt;BR&gt;8. Equipped with remote control of fire signal output&lt;BR&gt;&lt;BR&gt;Specifications and Technical Parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR bgColor=#d1e9d3&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;specification&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;circuit breaker model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;6%&quot;&gt;
&lt;DIV align=center&gt;Cabinet current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;
&lt;DIV align=center&gt;Rated working current A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;Breaking current KA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;5%&quot;&gt;
&lt;DIV align=center&gt;Rated working voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;4%&quot;&gt;
&lt;DIV align=center&gt;Insulation voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;
&lt;DIV align=center&gt;frequency&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;switch time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;8%&quot;&gt;
&lt;DIV align=center&gt;Intelligent controller voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;
&lt;DIV align=center&gt;mechanical life&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-63/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;P align=center&gt;M-NZM series&lt;BR&gt;&lt;BR&gt;M-NZS series&lt;BR&gt;&lt;BR&gt;M-NZA series&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;3. 6, 10, 20, 25, 32, 40, 50, 63&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;Refer to the specific model circuit breaker manual&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;50~60Hz&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;Adjustable from 1 to 30 seconds&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;AC220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=14&gt;
&lt;DIV align=center&gt;Split and merge into one 5000&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-63/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-100/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;10. 16, 20, 32, 40, 50, 63, 80, 100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-100/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-225/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;two hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;100, 125, 140, 160, 180, 200, 225&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-225/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-400/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;200, 250, 315, 350, 400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-400/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-630/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;250, 315, 350, 40, 500, 630&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-630/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-800/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-800/4&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-1250/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;two thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;M-ATS1-2000/3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Installation diagram and wiring diagram&lt;BR&gt;Intelligent controller dimensions, installation dimensions, and opening dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851323570431.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;Installation and wiring diagram of M-ATS1 series intelligent dual power automatic switch&quot; src=&quot;/uploadfiles/200805/200851323570431.gif&quot; width=680 height=310&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Split type appearance and installation dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008513235724503.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 220px&quot; border=0 hspace=0 alt=&quot;M-ATS1 series intelligent dual power automatic switch technical parameters 1&quot; src=&quot;/uploadfiles/200805/2008513235724503.gif&quot; width=680 height=220&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Integrated appearance and installation dimensions&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/2008513235746731.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 230px&quot; border=0 hspace=0 alt=&quot;M-ATS1 series intelligent dual power automatic switch technical parameters 2&quot; src=&quot;/uploadfiles/200805/2008513235746731.gif&quot; width=680 height=230&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Principle of wiring diagram&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200805/200851323589936.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 310px&quot; border=0 hspace=0 alt=&quot;M-ATS1 series intelligent dual power automatic switching switch contact diagram&quot; src=&quot;/uploadfiles/200805/200851323589936.gif&quot; width=680 height=310&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Intelligent Controller Description and Settings&lt;BR&gt;Intelligent Controller Panel Description&lt;BR&gt;a. NA, NB, NC are commonly used power indicators; Illuminated indicates normal operation, idle indicates undervoltage or phase failure; RA and RB=RC are backup power sources.&lt;BR&gt;b. Press the auto button to select the auto reset or non auto reset function. Pressing the double key can disconnect the load from the common or backup power source.&lt;BR&gt;c. When the system malfunctions, the OA flashes, the alarm flashes, and an alarm sound is detected. Pressing the button can terminate the alarm. If the fault still persists, the alarm will sound again 30 seconds later.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200805/2008513235833330.gif&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 140px&quot; border=0 hspace=0 alt=&quot;M-ATS1 series intelligent dual power automatic switch appearance layout&quot; src=&quot;/uploadfiles/200805/2008513235833330.gif&quot; width=680 height=140&gt;&lt;/A&gt;&lt;BR&gt;M-ATS1 series intelligent dual power automatic switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SGATS3 Series Dual Power Automatic Switching Switch </title>
           <link>http://www.91way.com/info_en/2722.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:39</pubDate>
           <comments></comments>
           <description>The SGATS3 dual power automatic transfer switch series automatic transfer switch is a new generation of automatic transfer switch developed by our company using microcomputer control technology. This switch uses Schneider Electric's Multi9 series and Compact series circuit breakers or load switches as actuating components, and is equipped with a new type of control mechanism that integrates mechanical and electrical components and has dual mechanical and electrical interlocking. It is particularly suitable for use in important power supply areas where power outages are not allowed. To meet the on-site requirements, the automatic transfer switch can achieve three different working modes: self switching and self resetting, self switching without self resetting, and mutual backup.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SGATS2 Series Dual Power Automatic Switching Switch </title>
           <link>http://www.91way.com/info_en/2721.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:30</pubDate>
           <comments></comments>
           <description>SGATS2 series dual power automatic switch&lt;BR&gt;&lt;BR&gt;With the rapid development of technology today, power system equipment is gradually moving towards centralized monitoring and intelligence, that is, weak current (electronic) control of strong current.&lt;BR&gt;&lt;BR&gt;The SGATS2 series dual power automatic switch is based on the latest microcomputer control system, with electromagnetic compatibility design, strong anti-interference ability, and long-term stable and reliable operation. It is equipped with a large backlit LCD display, forming a good human-machine dialogue interface for users. The operation is easy to warn and highly intelligent, making it an ideal new type of electromechanical integrated dual power automatic switch. At the same time, it has ushered in a new era of intelligent and networked development for dual power automatic switching systems, and is also an updated product of similar products in China.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SGATS1 Series Dual Power Automatic Switching Switch </title>
           <link>http://www.91way.com/info_en/2720.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:22</pubDate>
           <comments></comments>
           <description>Environmental conditions for the use of SGATS1 series dual power automatic switch&lt;BR&gt;&lt;BR&gt;1. The ambient air temperature shall not exceed -5 ¡æ -+40 ¡æ, and the average temperature within 24 hours shall not exceed+35 ¡æ;&lt;BR&gt;2. Installation location with an altitude not exceeding 2000m&lt;BR&gt;3. In places where there is no explosive hazard in the medium and the medium is insufficient to corrode metals and damage insulation with gases and conductive dust;&lt;BR&gt;4. A place without rain or snow erosion.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]RMQ3 series automatic transfer switch </title>
           <link>http://www.91way.com/info_en/2392.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:13</pubDate>
           <comments></comments>
           <description>RMQ3 series automatic transfer switch product usage:&lt;BR&gt;&lt;BR&gt;The RMQ3-63 automatic transfer switch belongs to CB level and is mainly used in three-phase four wire dual circuit power supply grids with a rated working voltage of 50Hz 400V and a rated current of 63A or below. When one power supply encounters an abnormal situation or the C-phase is disconnected, it can automatically switch to another normal power supply and has short-circuit and overcurrent protection for the load circuit.&lt;BR&gt;&lt;BR&gt;Technical data and performance:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=680 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Shell level rated current (Inm) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working current (In) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working voltage (Ue) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated insulation voltage (Ui) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated control power supply voltage (Us) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated connection and disconnection capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit breaking capacity (Icn) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-circuit making capacity (Icm) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;polar number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Conversion action time s&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Electrical lifespan (number of operating cycles)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Mechanical lifespan (number of operating cycles)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Electric motor power W&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6. 10, 16, 20, 25, 32, 40, 50, 63&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;50HzAC220&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6le&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.53lcm&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3P¡¢4P&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&amp;lt;2.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five thousand&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P align=center&gt;50HzAC220&lt;BR&gt;20W&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMQ3 series automatic transfer switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]RMQ2 Series Dual Power Automatic Switching Device </title>
           <link>http://www.91way.com/info_en/2391.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:32:04</pubDate>
           <comments></comments>
           <description>Product Usage&lt;BR&gt;&lt;BR&gt;The RMQ2 series dual power automatic switching device is CB level, suitable for three-phase four wire dual power supply (common power supply and backup power supply or generator power supply) with AC 50Hz 400V rated current up to 800A and below. When one power supply fails, it can automatically switch to the other normal power supply and has overcurrent trip protection for the load circuit. &amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical data and performance of RMQ2 series dual power automatic switching device:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;Shell level rated current (Inm) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;Model of plastic shell circuit breaker used&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;Polar number (P)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;Breaking capacity (Icu) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;
&lt;DIV align=center&gt;Rated current (In) A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-63H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-63H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10. 12.5, 16, 20, 25, 32, 40, 50, 63&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-100H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-100H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;16. 20, 32, 40, 50, 63, 80, 100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;
&lt;DIV align=center&gt;RMQ2-100S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-100S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-250H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-250H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;100, 125, 160, 180, 200, 225, 250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-250S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-250S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-400H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-400H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;250, 315, 350, 400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-400S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-400S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-630H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-630H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;500, 600, 630&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-630S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-630S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-800H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-800H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;700, 800&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ2-800S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-800S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMQ2 series dual power automatic switching device&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]HQ2 series intelligent dual power automatic switching switch </title>
           <link>http://www.91way.com/info_en/2185.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:56</pubDate>
           <comments></comments>
           <description>The HQ2 series intelligent dual power automatic switch is suitable for AC 50HZ, 400V dual power supply systems, and can automatically switch between common power supply and backup power supply to ensure the reliability and safety of power supply.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]STK8 Dual power automatic transfer switch </title>
           <link>http://www.91way.com/info_en/768.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:47</pubDate>
           <comments></comments>
           <description>STK dual power automatic transfer switch (A.T.S) is a three pole or four pole switch that can perform automatic or remote automatic transfer. It can ensure the switching and isolation of dual power sources. Its main product, dual power automatic transfer switch and its matching intelligent display, is mainly suitable for important occasions such as high-rise buildings, postal and telecommunications, coal mines, ships, military facilities, industrial assembly lines, railways, highways, airports, etc. In the inevitable trend of rapid increase in urban electricity consumption, it can better meet the higher requirements of electricity reliability.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]RMT1 series dual power conversion switch </title>
           <link>http://www.91way.com/info_en/272.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:39</pubDate>
           <comments></comments>
           <description>The RMT1 series transfer switch is mainly suitable for circuits with AC 50Hz, rated voltage 400V, rated current 630A and below, to complete the conversion between two sets of circuits. After being equipped with the RMAT1 intelligent controller, it has the function of automatically detecting the line voltage of commonly used three-phase power supplies, adjusting the conversion voltage range and time, and has a disconnect position in the middle during conversion. This product can be applied to factories, banks, hospitals, shopping malls, high-rise buildings, and other important occasions, especially suitable for achieving power conversion between mains electricity.&lt;BR&gt;&lt;BR&gt;Technical data and performance of RMT1 series dual power conversion switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=650 align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;30%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;RMT1-250&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;RMT1-630&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Shell level current (Inm) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=3&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated insulation voltage (Ui) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;DIV align=center&gt;six hundred and ninety&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Agreed heating current (Ith) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;10%&quot;&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated impulse withstand voltage (Uimp) kV&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working voltage (Ue) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;DIV align=center&gt;Communication 50Hz AC400V&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated working current (Ie) V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated limit short-circuit current (peak) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated value of fuse (NT type fuse) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and sixty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Rated short-time withstand current (1s) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twelve point six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMT1 series dual power conversion switch&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]RMQ1 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/269.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:30</pubDate>
           <comments></comments>
           <description>RMQ1 series dual power automatic transfer switch product usage:&lt;BR&gt;The RMQ1 series automatic switching CB level is suitable for three-phase four wire dual power supply (common power supply and backup power supply or generator power supply) with AC 50Hz, rated working voltage of 400V, and rated current up to 800A and below. When one power supply experiences undervoltage, overvoltage or phase failure, it can automatically switch to the other normal power supply and has overcurrent protection for the load circuit. In places and load power systems that require continuous uninterrupted power supply, when the common power supply fails or loses power, the backup power supply is required to be put into use in a very short time. The RMQ1 automatic transfer switch has the function to meet the above requirements&lt;BR&gt;&lt;BR&gt;Technical data and performance of RMQ1 series dual power automatic transfer switch:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; border=1 cellSpacing=0 cellPadding=1 width=&quot;100%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;13%&quot;&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;17%&quot;&gt;
&lt;DIV align=center&gt;Shell level rated current (Inm) A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;
&lt;DIV align=center&gt;Model of plastic shell circuit breaker used&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;7%&quot;&gt;
&lt;DIV align=center&gt;Polar number (P)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot;&gt;
&lt;DIV align=center&gt;Breaking capacity (Icu) kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;
&lt;DIV align=center&gt;Rated current (In) A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-63H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-63H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;10. 12.5, 16, 20, 25, 32, 40, 50, 63&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-100H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-100H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;16. 20, 32, 40, 50, 63, 80, 100&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;
&lt;DIV align=center&gt;RMQ1-100S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-100S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-250H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-250H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;100, 125, 160, 180, 200, 225, 250&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-250S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-250S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;thirty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-400H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-400H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;250, 315, 350, 400&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-400S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-400S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-630H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-630H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;500, 600, 630&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-630S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;six hundred and thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-630S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;3. 4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-800H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-800H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;sixty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;700, 800&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMQ1-800S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;eight hundred&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;RMM1-800S&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;RMQ1 series dual power automatic transfer switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SQP1 series automatic power transfer switch </title>
           <link>http://www.91way.com/info_en/256.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:21</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Name: SQP1 Series Automatic Power Transfer Switch&lt;BR&gt;Compliant with standards:&lt;BR&gt;Product price: negotiable&lt;BR&gt;Scope of application:&lt;BR&gt;The SQP1 series automatic power transfer switch is a new generation of PC level automatic power transfer switch with patented technology jointly developed by our unit and Shanghai Electric Science Research Institute. It is suitable for rated insulation voltage of 690V, frequency of 50Hz, rated working voltage of 400V and below, and rated current from 32A (or below) to 1600A. It is suitable for high-rise buildings, hospitals, shopping malls, banks, fire protection, chemical industry, metallurgy and other places that require uninterrupted normal power supply. It completes the automatic power transfer of dual circuit power supply system to ensure the reliability of power supply for important users. This product complies with the national standard GB/T14048.11-2002 &quot;Automatic Transfer Switchgear&quot;.&lt;BR&gt;&lt;BR&gt;SQP1 series automatic power transfer switch product model:&lt;/P&gt;
&lt;P&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 429px; HEIGHT: 232px&quot; border=0 hspace=0 alt=&quot;SQP1 series automatic power transfer switch model description&quot; align=top src=&quot;/uploadfiles/200610/200610239561365.gif&quot; width=429 height=232&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SQG1 series automatic power transfer switch </title>
           <link>http://www.91way.com/info_en/255.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:13</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;Scope of application:&lt;BR&gt;&lt;BR&gt;The SQG1 series automatic power transfer switch (referred to as SQG1) is a new generation of PC level automatic power transfer switch with patented technology in our unit. It is suitable for rated insulation voltage of 690V, frequency of 50Hz, rated working voltage of 400V and below, and rated current from 63A (or below) to 1600A. SQG1 is suitable for high-rise buildings, hospitals, shopping malls, banks, fire protection, chemical, metallurgical and other places that require uninterrupted normal power supply. It completes the automatic power transfer of the dual circuit power supply system to ensure the reliability of power supply for important users. This product complies with the national standard GB/T14048.11-2002 &quot;Automatic Transfer Switchgear&quot;.&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;Product Model:&lt;IMG style=&quot;FILTER: ; WIDTH: 389px; HEIGHT: 209px&quot; border=0 hspace=0 alt=&quot;SQG1 series automatic power transfer switch model description&quot; align=top src=&quot;/uploadfiles/200610/2006102395151304.gif&quot; width=389 height=209&gt;&lt;BR&gt;SQG1 series automatic power transfer switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SQ40E series ultra small automatic power transfer switch </title>
           <link>http://www.91way.com/info_en/254.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:31:04</pubDate>
           <comments></comments>
           <description>Product Name: SQ40E Series Ultra Small Automatic Power Conversion Switch&lt;BR&gt;Compliant with standards:&lt;BR&gt;Product price:&lt;BR&gt;&lt;BR&gt;Scope of application:&lt;BR&gt;The SQ40E-63 series small automatic power transfer switch (ATSE) is an extension product of the SQ40 series automatic power transfer switch. It mainly consists of two ZB30 series small circuit breakers, a single motor operating mechanism with mechanical and electrical dual interlocking, and an intelligent controller. This product has many advantages such as small size, high reliability, complete protection functions, and easy operation, and has obtained multiple national patents. It is suitable for dual circuit power supply systems at the end of the line. If users need higher short-circuit breaking capacity, SQ40-63 series products can be selected. The SQ40E-63 series small automatic power transfer switch is suitable for high-rise buildings, hospitals, shopping malls, banks, fire protection, chemical, metallurgical and other places that require uninterrupted normal power supply. It completes the automatic power transfer of the dual circuit power supply system to ensure the reliability of power supply for important users. This product complies with the IEC60947-6-1-1998 &quot;Automatic Transfer Switchgear&quot; standard and the GB/T14048.11-2002 &quot;Automatic Transfer Switchgear&quot; standard.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SQ40 series automatic power transfer switch </title>
           <link>http://www.91way.com/info_en/253.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:30:56</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Name: SQ40 Series Automatic Power Transfer Switch&lt;BR&gt;&lt;BR&gt;Compliant with IEC60947-6-1-1998 &quot;Automatic Transfer Switchgear&quot; standard and GB/T14048.11-2002 &quot;Automatic Transfer Switchgear&quot; standard.&lt;BR&gt;&lt;BR&gt;Product Overview:&lt;BR&gt;The SQ40 series automatic power transfer switch (ATSE) mainly consists of two SM40 circuit breakers with high breaking capacity, a single motor operating mechanism with mechanical and electrical dual interlocking developed by our company, and an intelligent controller with high reliability performance. It is suitable for high-rise buildings, hospitals, shopping malls, banks, fire protection, chemical industry, metallurgy and other places that require uninterrupted normal power supply. It completes the automatic power transfer of the dual circuit power supply system to ensure the reliability of power supply for important users. This product complies with the IEC60947-6-1-1998 &quot;Automatic Transfer Switchgear&quot; standard and the GB/T14048.11-2002 &quot;Automatic Transfer Switchgear&quot; standard. Our unit can also provide users with non-standard &quot;self switching but not self resetting&quot; automatic power transfer switches (automatic transfer switches specified in IEC60947-6-1-1998 and GB/T14048.11-2002 standards are self switching and self resetting).&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Product Model:&lt;IMG style=&quot;FILTER: ; WIDTH: 514px; HEIGHT: 254px&quot; border=0 hspace=0 alt=&quot;SQ40 series automatic power transfer switch model description&quot; align=top src=&quot;/uploadfiles/200610/2006102392211617.gif&quot; width=514 height=254&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;SQ40 series automatic power transfer switch&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SJMQ3 Series Dual Power Automatic Switching Device </title>
           <link>http://www.91way.com/info_en/198.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:30:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;SJMQ3 series dual power automatic switching device&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 652px&quot; border=0 hspace=0 alt=&quot;Outline drawing of SJMQ3 series dual power automatic switching device&quot; src=&quot;/uploadfiles/200610/20061021113346729.jpg&quot; width=652 height=652&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Model Description of SJMQ3 Series Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200610/20061021113359249.jpg&quot; width=652 height=850&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;SJMQ3 series dual power automatic switching device appearance and installation dimensions&quot; src=&quot;/uploadfiles/200610/20061021113429116.jpg&quot; width=652 height=850&gt;&lt;BR&gt;&lt;BR&gt;SJMQ3 series dual power automatic switching device&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SJMQ2 Series Dual Power Automatic Switching Device </title>
           <link>http://www.91way.com/info_en/197.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:30:39</pubDate>
           <comments></comments>
           <description>SJMQ2 series dual power automatic switching device&lt;BR&gt;
&lt;TABLE style=&quot;BORDER-COLLAPSE: collapse; TABLE-LAYOUT: fixed&quot; cellSpacing=1 cellPadding=5 width=&quot;97%&quot; align=center&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD style=&quot;FONT-SIZE: 10.5pt&quot; id=zoom&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 652px&quot; border=0 hspace=0 alt=&quot;SJMQ2 series dual power automatic switching device appearance and technical parameters&quot; src=&quot;/uploadfiles/200610/20061021112338700.jpg&quot; width=680 height=652&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Model Description of SJMQ2 Series Dual Power Automatic Switching Device&quot; src=&quot;/uploadfiles/200610/20061021112350945.jpg&quot; width=652 height=850&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Technical data of SJMQ2 series dual power automatic switching device&quot; src=&quot;/uploadfiles/200610/2006102111242443.jpg&quot; width=652 height=850&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;SJMQ2 series dual power automatic switching device&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[dual power switch]SJMQ1 Series Dual Power Automatic Transfer Switch </title>
           <link>http://www.91way.com/info_en/196.html</link>
           <author></author>
           <guid></guid>
           <category>dual power switch</category>
           <pubDate>2026-6-16 12:30:30</pubDate>
           <comments></comments>
           <description>&lt;P&gt;SJMQ1 series dual power automatic transfer switch&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;
&lt;P align=center&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 680px; HEIGHT: 666px&quot; border=0 hspace=0 alt=&quot;Outline drawing of SJMQ1 series dual power automatic transfer switch&quot; src=&quot;http://www.91way.com/uploadfiles/200610/2006102111139667.jpg&quot; width=680 height=666&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Model Description of SJMQ1 Series Dual Power Automatic Transfer Switch&quot; src=&quot;http://www.91way.com/uploadfiles/200610/2006102111151627.jpg&quot; width=652 height=850&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE border=0 cellSpacing=0 cellPadding=0 width=&quot;100%&quot;&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;100%&quot;&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Technical Description of SJMQ1 Series Dual Power Automatic Transfer Switch&quot; src=&quot;http://www.91way.com/uploadfiles/200610/200610211122632.jpg&quot; width=652 height=850&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201412/20141212174559800.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;FILTER: ; WIDTH: 652px; HEIGHT: 850px&quot; border=0 hspace=0 alt=&quot;Technical parameters of SJMQ1 series dual power automatic transfer switch&quot; src=&quot;/upload2014/201412/20141212174559800.jpg&quot; width=652 height=850&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;SJMQ1 series dual power automatic transfer switch&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
