<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Precision Transformer</title>
       <link>http://www.91way.com</link>
       <description>Precision Transformer</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:08:12</pubDate>
       <item>
           <title>[Precision Transformer]HLMZ-0.66 High precision current transformer </title>
           <link>http://www.91way.com/info_en/24750.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:40:10</pubDate>
           <comments></comments>
           <description>&lt;P&gt;HLMZ-0.66 high-precision current transformer&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2014/201403/20140329142607105.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 561px; WIDTH: 486px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of HLMZ-0.66 high-precision current transformer&quot; src=&quot;/upload2014/201403/20140329142607105.jpg&quot; width=486 height=561&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;HLMZ-0.66 high-precision current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HG type standard voltage transformer </title>
           <link>http://www.91way.com/info_en/23382.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:40:01</pubDate>
           <comments></comments>
           <description>HG type standard voltage transformers are mainly designed and manufactured for grassroots power supply and production departments according to the actual needs of transformer manufacturers. Our company has inflatable voltage standard transformers, oil immersed standard voltage transformers, and dry-type standard voltage transformers.&lt;BR&gt;&lt;BR&gt;Characteristics of HG type standard voltage transformer&lt;BR&gt;Compact structure, small size, easy to carry;&lt;BR&gt;No maintenance required, simple wiring and operation;&lt;BR&gt;Standard transformers with 5VA secondary load can be customized, and standard transformers with 0.2VA secondary load can be supplied in stock&lt;BR&gt;&lt;BR&gt;Technical specifications of HG type standard voltage transformer&lt;BR&gt;Primary voltage: 6KV~220KV&lt;BR&gt;Secondary voltage: 100V, 100/¡Ì 3V, 100/3V&lt;BR&gt;Voltage range: 20% to 120%&lt;BR&gt;Power factor: COS ¦Õ=0.8,1.0&lt;BR&gt;Accuracy level: 0.05-0.01 level&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJ9-1~5 Type Instrument Voltage Transformers </title>
           <link>http://www.91way.com/info_en/19723.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:50</pubDate>
           <comments></comments>
           <description>The HJ9-1-5 series instrument voltage transformers are suitable for measurement in single-phase AC circuits with a rated voltage of 1kV-10kV and a rated frequency of 50Hz.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJ35 Type Instrument Voltage Transformer </title>
           <link>http://www.91way.com/info_en/19722.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:41</pubDate>
           <comments></comments>
           <description>The HJ35 instrument voltage transformer is suitable for measurement in single-phase AC circuits with a rated voltage of 0.5kV and a rated frequency of 50Hz.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]DMG series standard transformers </title>
           <link>http://www.91way.com/info_en/16654.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:32</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;number&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;inductance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;accuracy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;structure&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;DMGa~DMGc&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;1mH~0.1H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;0.2%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Ceramic skeleton&lt;/DIV&gt;
&lt;DIV&gt;Plastic skeleton&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=426 colSpan=3&gt;
&lt;DIV&gt;Scale: 14 * 14 * 10cm&lt;SUP&gt;three&lt;/SUP&gt;£»¦µ15*h160cm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Weight: 1.7kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DMG series standard transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]GB Standard Transformer </title>
           <link>http://www.91way.com/info_en/16653.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:23</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 90%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;90%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;inductance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;accuracy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;structure&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;DMGa~DMGc&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;1mH~0.1H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;0.2%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Ceramic skeleton&lt;/DIV&gt;
&lt;DIV&gt;Plastic skeleton&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=426 colSpan=3&gt;
&lt;DIV&gt;Scale: 14 * 14 * 10cm&lt;SUP&gt;three&lt;/SUP&gt;£»¦µ15*h160cm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Weight: 1.7kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GB standard transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]GA Standard Transformer </title>
           <link>http://www.91way.com/info_en/16652.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:13</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;inductance&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;accuracy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;structure&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;DMGa~DMGc&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;1mH~0.1H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;0.2%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Ceramic skeleton&lt;/DIV&gt;
&lt;DIV&gt;Plastic skeleton&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=426 colSpan=3&gt;
&lt;DIV&gt;Scale: 14 * 14 * 10cm&lt;SUP&gt;three&lt;/SUP&gt;£»¦µ15*h160cm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Weight: 1.7kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GA standard transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]GC Standard Transformer </title>
           <link>http://www.91way.com/info_en/16651.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:39:04</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;inductance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=142&gt;
&lt;DIV&gt;accuracy&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;structure&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;DMGa~DMGc&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;1mH~0.1H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;0.2%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=142&gt;
&lt;DIV&gt;Ceramic skeleton&lt;/DIV&gt;
&lt;DIV&gt;Plastic skeleton&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=426 colSpan=3&gt;
&lt;DIV&gt;Scale: 14 * 14 * 10cm&lt;SUP&gt;three&lt;/SUP&gt;£»¦µ15*h160cm&lt;SUP&gt;two&lt;/SUP&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=142&gt;
&lt;DIV&gt;Weight: 1.7kg&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;GC standard transformer&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJ series standard voltage transformers </title>
           <link>http://www.91way.com/info_en/14948.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:53</pubDate>
           <comments></comments>
           <description>HJ series standard voltage transformer&lt;BR&gt;&lt;BR&gt;1. High accuracy voltage transformers ranging from 0.0005 to 0.001 levels&lt;BR&gt;Rated voltage ratio: 60-600V/100V&lt;BR&gt;Accuracy level: 0.0005-0.001 level&lt;BR&gt;&lt;BR&gt;Features: High accuracy, good stability&lt;BR&gt;Purpose: Used to expand the voltage range of 0.005-0.01 level digital power meters such as C1-1 and C1-2.&lt;BR&gt;Application: It has been adopted by the National Institute of Metrology and the China Electric Power Research Institute in the national energy benchmark device and the highest three-phase energy standard device of the power system, to expand the voltage range,&lt;BR&gt;It has been widely used in the metrology and power sectors.&lt;BR&gt;&lt;BR&gt;2. Portable precision voltage transformer&lt;BR&gt;Rated voltage ratio: 6 (6/), 10 (10/) KV/100V (100V/)&lt;BR&gt;Accuracy level: 0.02-0.01 level&lt;BR&gt;Features: Small size, light weight, easy to carry&lt;BR&gt;Purpose: Used as a calibration standard for voltage transformers&lt;BR&gt;3. Precision voltage transformer&lt;BR&gt;Rated voltage ratio: 60-750V/100/~150V&lt;BR&gt;Accuracy level: 0.005-0.05&lt;BR&gt;Purpose: Used for installation on precision electric energy meters or electrical measuring instruments inspection tables or for precision measurement&lt;BR&gt;4. Small and micro high-precision voltage transformers&lt;BR&gt;Rated voltage ratio: 60-600V/3V, 1V&lt;BR&gt;Accuracy level: 0.001-0.02 level&lt;BR&gt;Features: High accuracy, small size, light weight&lt;BR&gt;Purpose: For installation in digital power meters&lt;BR&gt;Application situation: It has been installed in the 0.01~0.1 level digital power meter produced by the manufacturer.&lt;BR&gt;5. 0.0002 level high-precision dual stage voltage transformer&lt;BR&gt;Rated voltage ratio: 10KV/100V&lt;BR&gt;Accuracy level: 0.0002 level&lt;BR&gt;Features: High accuracy, good stability&lt;BR&gt;Purpose: Used as a voltage ratio standard for calibrating standard voltage transformers of 0.001 level and below.&lt;BR&gt;6. Multi channel isolated precision voltage transformer&lt;BR&gt;Rated voltage ratio: ¢Ù 220V (power supply)/220V (multiple channels)&lt;BR&gt;¢Ú 60-100-220-380V/60-100-220-380V (multiple channels)&lt;BR&gt;Accuracy level: 0.01 to 0.05&lt;BR&gt;Characteristics: Accurate and reliable&lt;BR&gt;Purpose: Used for electric energy meter calibration platform&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL57 Type 0.1 Class Current Transformer </title>
           <link>http://www.91way.com/info_en/11172.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:44</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The iron core of HL57 type 0.1 level current transformer is made by winding a specially treated high permeability soft magnetic alloy strip. The coil winding adopts the segmented winding method, ensuring that the transformer error is small and the working frequency is 50Hz. This transformer fully complies with the GB1208 national standard.&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;FONT-SIZE: 9pt; WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 width=30&gt;model&lt;/TD&gt;
&lt;TD rowSpan=2 width=26&gt;product&lt;BR&gt;name&lt;/TD&gt;
&lt;TD colSpan=6&gt;Main technical indicators&lt;/TD&gt;
&lt;TD rowSpan=2 width=76&gt;Characteristics and Applications&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=4 align=center&gt;Quantity limit&lt;/TD&gt;
&lt;TD width=78 align=center&gt;Overall dimensions&lt;/TD&gt;
&lt;TD width=29 align=center&gt;Factory price (yuan)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=113&gt;
&lt;P&gt;HL57&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=26&gt;current transformer&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;Beginner: 0.1/0.2/0.25/0.5/1/2/2.5/10/15/20/25/50/75/100A&lt;/P&gt;
&lt;P&gt;Secondary: 5A working voltage ¡Ü 500V frequency 50HZ rated load 10VA&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;360x230x211mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;four thousand&lt;/TD&gt;
&lt;TD rowSpan=2 align=left&gt;Internal current comparator, follow-up amplifier, automatic balancing weight ¡Ü 13kg&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=101&gt;HL57-1&lt;/TD&gt;
&lt;TD&gt;current transformer&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.6/0.75/1/&lt;/P&gt;
&lt;P&gt;1.5/2/2.5/3/4/5/6/7.5/8/10/15/20/25/30/40/50A&lt;/P&gt;
&lt;P&gt;Secondary: 5A working voltage ¡Ü 500V frequency 50HZ rated load 10VA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;HL57 type 0.1 level current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL3-0.2 Instrument precision current transformer </title>
           <link>http://www.91way.com/info_en/4896.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:34</pubDate>
           <comments></comments>
           <description>HL1 (A) -0.2 instrument precision current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL23-5 Instrument precision current transformer </title>
           <link>http://www.91way.com/info_en/4895.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:24</pubDate>
           <comments></comments>
           <description>The precision current transformer for HL23-5 instrument has an accuracy of 0.2, 0.1, 0.05, 0.02, and 0.01 levels, with a primary current of 0.05-5000 amperes and secondary currents of 5, 1, 0.5, and 0.4 amperes. The product has the advantages of reasonable parameter selection, appropriate compensation, stable performance, large margin of error, and good appearance quality&lt;BR&gt;&lt;BR&gt;HL23-5 instrument precision current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL55 Instrument precision current transformer </title>
           <link>http://www.91way.com/info_en/4894.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:16</pubDate>
           <comments></comments>
           <description>HL55 instrument precision current transformer&lt;BR&gt;&lt;BR&gt;HL55/HL55A current transformer&lt;BR&gt;&lt;BR&gt;Junior: 10/20/50/100/150/200/300/600A,&lt;BR&gt;Secondary: 5A,&lt;BR&gt;Working voltage ¡Ü 500V,&lt;BR&gt;Working frequency: 50Hz,&lt;BR&gt;Rated load: 5VA&lt;BR&gt;&lt;BR&gt;Level 0.2&lt;BR&gt;0.1 level&lt;BR&gt;Instrument expansion limit&lt;BR&gt;Weight ¡Ü 3Kg&lt;BR&gt;Aperture: 37mm&lt;BR&gt;&lt;BR&gt;HL55-1/HL55-A current transformer&lt;BR&gt;&lt;BR&gt;Primary: 10/20/50/100/150/200/300/600A, Secondary: 1A, Operating voltage ¡Ü 500V, Operating frequency: 50HZ, Rated load: 5VA&lt;BR&gt;Level 0.2&lt;BR&gt;0.1 level&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL70 Instrument precision current transformer </title>
           <link>http://www.91way.com/info_en/4893.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:38:07</pubDate>
           <comments></comments>
           <description>Application range of HL70 HL-0.5 series precision current transformer
&lt;P&gt;HL type precision current transformer is used in conjunction with a transformer calibrator and testing equipment to calibrate current transformers that are one to two levels lower than it; It can also be used to expand the limit device and measure current, power, and electrical energy in conjunction with corresponding precision instruments.&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;model&lt;/TD&gt;
&lt;TD colSpan=4&gt;Main technical indicators&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;standard degree&lt;BR&gt;level&lt;/TD&gt;
&lt;TD&gt;power factor&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Rated load (VA)&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Primary current (A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL1&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Fixed: 15, 50 Thread through: 100-150-200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL1A&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;zero point one&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Fixed: 15, 50 Thread through: 100-150-200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL2&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL3&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-1-2-5-10-20-50&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL5-1&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8 or 1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-6-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300-500-600-750-800-1000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL16&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;300-400-500-600-750-1000-1500-2000-3000-4000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL18&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-6-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300-400-500&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL19&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;500-600-750-800-1000-2000-3000-4000-5000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8 or 1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-1&lt;/TD&gt;
&lt;TD rowSpan=5&gt;zero point two&lt;/TD&gt;
&lt;TD rowSpan=5&gt;zero point eight&lt;/TD&gt;
&lt;TD rowSpan=5&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-2&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-3&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;15-30-50-75-150-200-300-400-600-700-800-1200-1400-1600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-4&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-5&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.25-0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-900-1000-1200-1400-1500-1800-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL23-9&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.25-0.5-1-2.5-5-10-25-50-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL24-1&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point two&lt;/TD&gt;
&lt;TD rowSpan=5&gt;zero point eight&lt;/TD&gt;
&lt;TD rowSpan=5&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;10-25-50-100-150-200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL24-2&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;10-25-50-100-200-250-500-1000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL24-1A&lt;/TD&gt;
&lt;TD rowSpan=3&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;10-25-50-100-150-200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL24-2A&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;10-25-50-100-200-250-500-1000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;0.5-1-2-2.5-5-10-15-20-25-30-50-75-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL32-1&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point one&lt;/TD&gt;
&lt;TD rowSpan=2&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL32-2&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-2-2.5-5-10-15-20-25-30-50-75-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL34&lt;/TD&gt;
&lt;TD&gt;zero point zero two&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL35&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL35-1&lt;/TD&gt;
&lt;TD rowSpan=3&gt;zero point one&lt;/TD&gt;
&lt;TD rowSpan=3&gt;0.8-1&lt;/TD&gt;
&lt;TD rowSpan=3&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.5-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-75-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL35-2&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-7.5-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-750-800-1000-1500-2500-3000-4000-5000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL35-4&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;15-20-25-30-40-50-60-80-100-150-200-250-300-400-500-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL36&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL36A&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL36-1&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000 (secondary 1A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL36-1A&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000 (secondary 1A)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL37-4&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;15-20-25-30-40-50-60-80-100-150-200-250-300-400-500-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL41&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL42&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL50A&lt;/TD&gt;
&lt;TD&gt;zero point zero five&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;5-7.5-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000-2500-3000-4000-5000-6000-7500-8000-10000&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL55&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Terminal: 10-20-50 Thread through: 100-150-200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL55A&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;Terminal: 10-20-50 Thread through: 100-150-200-300-600&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL55-1&lt;/TD&gt;
&lt;TD&gt;zero point two&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Terminal: 10-20-50 Thread through: 100-150-200-300-600 (secondary 1A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL55-1A&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Terminal: 10-20-50 Thread through: 100-150-200-300-600 (secondary 1A)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL55T&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point two&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point two&lt;/TD&gt;
&lt;TD rowSpan=2&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Terminal: 5-20-100 Thread through: 200-300-600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL79&lt;/TD&gt;
&lt;TD rowSpan=9&gt;zero point zero five&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seven point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL79-1&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;5/7.5&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL79-2&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL79-3&lt;/TD&gt;
&lt;TD rowSpan=5&gt;one&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;5-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL79-4&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;five&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;5-7.5-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-750-800-1000-1500-2000-2500-3000-4000-5000&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;ten&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL79-5&lt;/TD&gt;
&lt;TD rowSpan=2&gt;ten&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;HL94&lt;/TD&gt;
&lt;TD rowSpan=4&gt;zero point zero two&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;five&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;seven point five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL94-1&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL94-2&lt;/TD&gt;
&lt;TD&gt;0.8 or 1&lt;/TD&gt;
&lt;TD&gt;ten&lt;/TD&gt;
&lt;TD&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL94-3&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;0.8-1&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL94A&lt;/TD&gt;
&lt;TD rowSpan=2&gt;zero point zero one&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HL94B&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;seven point five&lt;/TD&gt;
&lt;TD&gt;0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-3-4-5-6-7.5-10-15-20-30-40-50-60-75-80-100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HLS3&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;5A-1000A (with 100A or higher core penetration, equipped with a built-in current regulator)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;HLS5&lt;/TD&gt;
&lt;TD&gt;zero point one&lt;/TD&gt;
&lt;TD&gt;zero point five&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;5A-2000A (Over 500A core, with built-in current regulator)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HL70 instrument precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL36 Instrument precision current transformer </title>
           <link>http://www.91way.com/info_en/4892.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:58</pubDate>
           <comments></comments>
           <description>Application range of HL36, HL36A, HL36-1, HL36-1A series precision current transformers&lt;BR&gt;&lt;BR&gt;HL36, HL36A, HL36-1, HL36-1A precision current transformers are used in conjunction with transformer calibrators and testing equipment to calibrate current transformers that are one to two levels lower than them; It can also be used to expand the limit device and measure current, power, and electrical energy in conjunction with corresponding precision instruments.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=1 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;Product Name&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Main technical indicators&lt;/P&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;P&gt;Characteristics and Applications&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Quantity limit&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Overall dimensions&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;HL36&lt;/P&gt;
&lt;P&gt;HL36A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;current transformer&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;Junior: 100/150/200/300/400/500/600/750/800/1000/1200/1500/2000A&lt;BR&gt;Secondary: 5A working voltage ¡Ü 500V frequency 50HZ rated load 10VA&lt;BR&gt;Aperture: 75mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;200&#215;189&#215;89 mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;zero point two&lt;/P&gt;
&lt;P&gt;zero point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;HL36-1&lt;/P&gt;
&lt;P&gt;HL36-1A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;current transformer&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;P&gt;Amperage: 100A150A 200A 250A 300A 500A 600A&lt;BR&gt;Number of through turns: 12 8 6 6 4 3 2&lt;BR&gt;Amperage: 750A800A 1000A 1200A 1500A 2000A&lt;BR&gt;Number of through turns: 2 2 1 1 1 1 1&lt;BR&gt;Primary: Same as above Secondary: 1A&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;zero point two&lt;/P&gt;
&lt;P&gt;zero point one&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HL36 instrument precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJF type inductive voltage divider </title>
           <link>http://www.91way.com/info_en/4550.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:49</pubDate>
           <comments></comments>
           <description>The HJF1 induction voltage divider adopts high nickel Permalloy as the magnetic material, and is uniformly wound with high-strength ester coated wire, with a reasonable and reliable structure. Mainly used for verifying voltage transformers with different voltage ratios from standard voltage transformers (including different primary or secondary voltages). This instrument consists of two parts: a two-stage voltage transformer and an inductive voltage divider. The secondary coil of the two-stage voltage transformer serves as the input coil of the voltage divider. Adopting this structure can not only improve the input impedance but also increase the output voltage of the inductive voltage divider. At this time, the inductive voltage divider is used for boosting. This device has high accuracy, small size, light weight, and easy to use.&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&#183;Accuracy level: 0.005 level&lt;BR&gt;&#183;Input voltage: 100V, 150V, 300V, 600V&lt;BR&gt;&#183;Output voltage: 0.001V-11.11V&lt;BR&gt;&#183;Rated frequency: 50Hz&lt;BR&gt;&#183;Overload capacity: 1.5 times&lt;BR&gt;&#183;Dimensions (mm): 360 &#215; 240 &#215; 180&lt;BR&gt;&#183;Weight: Approximately 8kg&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJS-35 Type Self Boosting Precision Voltage Transformer </title>
           <link>http://www.91way.com/info_en/4549.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:39</pubDate>
           <comments></comments>
           <description>The HJS type precision voltage transformer is made of cold-rolled oriented silicon steel sheets with high magnetic density and permeability, which are rolled and heat-treated. It has independent boosters and transformers inside. The booster adopts magnetic shielding, and the high voltage output of the booster is connected in parallel with the primary voltage winding of the standard transformer through the high voltage terminal as the boost output, providing high voltage to the tested voltage transformer. The transformer adopts a fully insulated structure between high and low voltage, and the high voltage winding uses special materials and effective oil-free insulation technology, eliminating the disadvantages of oil immersed boosters.&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&#183;Rated primary voltage: 35KV&lt;BR&gt;&#183;Rated secondary voltage: 100V, 100/3V, 100/3V&lt;BR&gt;&#183;Accuracy: 0.01, 0.02, 0.05 levels (selected by the user)&lt;BR&gt;&#183;Rated secondary load: 0.2VA&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HJS-10 Type Self Boosting Precision Voltage Transformer </title>
           <link>http://www.91way.com/info_en/4548.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:31</pubDate>
           <comments></comments>
           <description>The HJS standard voltage transformer is made of high nickel Permalloy magnetic material and uniformly wound with high-strength ester coated wire, with a reasonable and reliable structure. Mainly used for verifying lower level voltage transformers. This device has high accuracy, small size, light weight, and is easy to use.&lt;BR&gt;&lt;BR&gt;Main technical indicators:&lt;BR&gt;&#183;Accuracy level: 0.01, 0.02, 0.05 (selected by the user)&lt;BR&gt;&#183;Rated primary voltage: 3KV, 6KV, 10KV or other special requirements for rated primary voltage&lt;BR&gt;&#183;Rated secondary voltage: 100V, 100/3V, 100/3V&lt;BR&gt;&#183;Rated secondary load: 0.2VA&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HLB type precision current transformer </title>
           <link>http://www.91way.com/info_en/4545.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:22</pubDate>
           <comments></comments>
           <description>The HLB type precision current transformer is made of high-quality iron core rolled surface and undergoes strict heat treatment, effectively improving the accuracy and width of the transformer. The transformer has a small volume, beautiful appearance, high accuracy, and simple wiring. Used to calibrate lower level current transformers. In addition, it can also be used as an expansion limit device, which can be used in conjunction with corresponding precision instruments to accurately measure power and electrical energy. Due to its small size, light weight, and easy portability, this model of equipment is more suitable for on-site testing and use.&lt;BR&gt;&lt;BR&gt;Main technical specifications of HLB type precision current transformer&lt;BR&gt;&#183;Accuracy level: 0.01 (S) level, 0.02 (S) level, 0.05 (S) level optional&lt;BR&gt;&#183;Rated primary current: 0.1A-100A, 5A-600A, 5A-2000A, 5A-3150A&lt;BR&gt;5A-5000A&lt;BR&gt;&#183;Rated secondary current: 5A, 1A&lt;BR&gt;&#183;Dimensions (mm): Depending on the specific model&lt;BR&gt;&#183;Weight: 15kg-20kg (depending on specific model)&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HLS type (with current transformer) precision current transformer </title>
           <link>http://www.91way.com/info_en/4544.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:13</pubDate>
           <comments></comments>
           <description>The HLS type (with current transformer) precision current transformer is made of high-quality iron core rolled and undergoes strict heat treatment, effectively improving the accuracy of the transformer. The transformer has a small volume, beautiful appearance, high accuracy, and simple wiring. Used to calibrate lower level current transformers. In addition, it can also be used as an expansion limit device, which can be used in conjunction with corresponding precision instruments to accurately measure power and electrical energy.&lt;BR&gt;&lt;BR&gt;Main technical specifications of HLS type (with current transformer) precision current transformer:&lt;BR&gt;&#183;Accuracy level: 0.01 (S) level, 0.02 (S) level, 0.05 (S) level optional&lt;BR&gt;&#183;Rated primary current: 5A-2000A, 5A-3150A, 5A-5000A optional&lt;BR&gt;&#183;Rated secondary current: 5A, 1A&lt;BR&gt;&#183;Dimensions (mm): Depending on the specific model&lt;BR&gt;&#183;Weight: 35kg-40kg (depending on specific model)&lt;BR&gt;&lt;BR&gt;Precision current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL24 series precision current transformer </title>
           <link>http://www.91way.com/info_en/3345.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:37:04</pubDate>
           <comments></comments>
           <description>&lt;P&gt;HL24 series precision current transformer&lt;BR&gt;&lt;BR&gt;The HL24 instrument current transformer is suitable for laboratory measurements in AC single-phase circuits with a rated frequency of 50Hz and a rated voltage of 0.5kV, and is used as a standard instrument for verifying current transformers and instrument devices.&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2012/201207/20120727094830360.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 185px; WIDTH: 250px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of HL24 series precision current transformer&quot; src=&quot;/upload2012/201207/20120727094830360.jpg&quot; width=250 height=185&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL24-1,HL24-2(A) series 0.5KV precision current transformers </title>
           <link>http://www.91way.com/info_en/1647.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:36:51</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/2006125151822621.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 793px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;HL24-1 (A) HL24-2 (A) series 0.5KV precision current transformer external dimensions and technical parameters&quot; src=&quot;/uploadfiles/200612/2006125151822621.jpg&quot; width=600 height=793&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;HL24-1 (A) HL24-2 (A) series 0.5KV precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL23-1,3,5 series 0.5KV precision current transformer </title>
           <link>http://www.91way.com/info_en/1646.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:36:42</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/2006125151636385.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 793px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of HL23-1 3 5 series 0.5KV precision current transformer&quot; src=&quot;/uploadfiles/200612/2006125151636385.jpg&quot; width=600 height=793&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;HL23-1 3 5 series 0.5KV precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL3£¬HL3A series 0.5KV precision current transformers </title>
           <link>http://www.91way.com/info_en/1645.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:36:33</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/2006125151438884.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 793px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of HL3 HL3A series 0.5KV precision current transformer&quot; src=&quot;/uploadfiles/200612/2006125151438884.jpg&quot; width=600 height=793&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;HL3 HL3A series 0.5KV precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]HL1/HL1A series 0.5KV precision current transformer </title>
           <link>http://www.91way.com/info_en/1644.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:36:24</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;Level: 0.2&lt;BR&gt;Primary current (A): 15-50-100-150-200-300-600&lt;BR&gt;Secondary current (A): 5&lt;BR&gt;Rated load: 5VA&lt;BR&gt;Power factor: 0.8&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200612/2006125151035728.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 793px; WIDTH: 600px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters and installation dimensions of HL1/HL1A series 0.5KV precision current transformers&quot; src=&quot;/uploadfiles/200612/2006125151035728.jpg&quot; width=600 height=793&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130725070320287.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 332px; WIDTH: 500px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of HL1/HL1A series 0.5KV precision current transformers&quot; src=&quot;/upload2013/201307/20130725070320287.gif&quot; width=500 height=332&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;HL1/1A series 0.5KV precision current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Precision Transformer]SCT series ultra small precision current transformer </title>
           <link>http://www.91way.com/info_en/1304.html</link>
           <author></author>
           <guid></guid>
           <category>Precision Transformer</category>
           <pubDate>2026-6-15 20:36:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Technical parameters of SCT series ultra small precision current transformer&lt;BR&gt;&lt;BR&gt;1. Secondary current: 2.5mA (10mA)~30mA (120mA) optional&lt;BR&gt;2. Accuracy: 0.1 level, linearity:&amp;lt;0.1%&lt;BR&gt;3. Load: 5-40 COS¦Õ=1.0&lt;BR&gt;4. Primary to secondary power frequency withstand voltage:&amp;gt;2.5KV&lt;BR&gt;5. Insulation: ¡Ý 100Mohm (500VDC)&lt;BR&gt;&lt;BR&gt;Appearance and installation dimensions&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200611/20061110123438795.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 200px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of SCT series ultra small precision current transformers&quot; src=&quot;/uploadfiles/200611/20061110123438795.jpg&quot; width=680 height=200&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;SCT series ultra small precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>

