           <title>[Miniature transformer]CT600 type current transformer </title>
           <link>http://www.91way.com/info_en/24273.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:46:12</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Length mm&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=5&gt;
&lt;P&gt;two hundred and eighty&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=4&gt;
&lt;P&gt;three hundred and seventy&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=8&gt;
&lt;P&gt;four hundred and fifty&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Specification A/mv&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;two hundred&lt;/P&gt;
&lt;P&gt;/30&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;three hundred and fifteen&lt;/P&gt;
&lt;P&gt;/50&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four hundred&lt;/P&gt;
&lt;P&gt;/60&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;six hundred and thirty&lt;/P&gt;
&lt;P&gt;/100&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;eight hundred&lt;/P&gt;
&lt;P&gt;/100&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one thousand&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one thousand two hundred and fifty&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;one thousand and six hundred&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;two thousand&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;two thousand and five hundred&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=29&gt;
&lt;P&gt;three thousand one hundred and fifty&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;three thousand and two hundred&lt;/P&gt;
&lt;P&gt;/200&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;three thousand and nine hundred&lt;/P&gt;
&lt;P&gt;/250&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;four thousand&lt;/P&gt;
&lt;P&gt;/250&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;five thousand&lt;/P&gt;
&lt;P&gt;/250&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;five thousand and nine hundred&lt;/P&gt;
&lt;P&gt;/250&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;P&gt;six thousand and three hundred&lt;/P&gt;
&lt;P&gt;/2&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CT600 type current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]VHL series miniature precision current transformer </title>
           <link>http://www.91way.com/info_en/17090.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:46:04</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/upload2011/201108/20110829203848792.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 786px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Technical parameters of VHL series miniature precision current transformer&quot; src=&quot;/upload2011/201108/20110829203848792.jpg&quot; width=680 height=786&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110829203901155.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 775px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;VHL series miniature precision current transformer installation size 1&quot; src=&quot;/upload2011/201108/20110829203901155.jpg&quot; width=680 height=775&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2011/201108/20110829203912408.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 784px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;VHL series miniature precision current transformer installation size 2&quot; src=&quot;/upload2011/201108/20110829203912408.jpg&quot; width=680 height=784&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;VHL series miniature precision current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTS100A,CTS200A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10039.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:54</pubDate>
           <comments></comments>
           <description>Characteristics of CTS100A and CTS200A miniature current transformers:&lt;BR&gt;&lt;BR&gt;1. Active type, customizable input/output current&lt;BR&gt;2. Compact and lightweight, easy to install&lt;BR&gt;3. High electromagnetic isolation, high precision, and no drift&lt;BR&gt;4. ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;CTS100A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;CTS200A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;Application scenarios&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;Fixed terminal output type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;Fixed terminal output type&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;Rated input&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;1.5(6A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;100A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;rated output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;5(20mA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;20mA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;accuracy class&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;0.1%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;0.1%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;Maximum phase shift&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;10＊&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;5＊&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;load resistor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;5/10/20/100次&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;5/10/20/100次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=507 colSpan=2&gt;
&lt;DIV align=center&gt;3000V/50Hz/1min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;overload capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;20A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;120A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;Normal working environment&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=507 colSpan=2&gt;
&lt;DIV&gt;Environmental temperature: -25~60 ⊥&lt;/DIV&gt;
&lt;DIV&gt;Humidity: 5%~95%&lt;/DIV&gt;
&lt;DIV&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=136&gt;
&lt;DIV align=center&gt;Appearance and installation diagram&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125224545584.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 212px; WIDTH: 200px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of CTS100A and CTS200A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125224545584.jpg&quot; width=200 height=212&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/2009112522461446.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 105px; WIDTH: 200px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of CTS100A and CTS200A miniature current transformers&quot; src=&quot;/upload2009/200911/2009112522461446.jpg&quot; width=200 height=105&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125224647572.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 103px; WIDTH: 177px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation diagram 1 of CTS100A and CTS200A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125224647572.jpg&quot; width=177 height=103&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV&gt;&lt;A href=&quot;/upload2009/200911/20091125224655756.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 105px; WIDTH: 133px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation diagram 2 of CTS100A and CTS200A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125224655756.jpg&quot; width=133 height=105&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;DIV align=center&gt;Kind reminder&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;DIV&gt;The input current of the primary side is 1-20A (specified when ordering), and the output current of the secondary side is 1-20mA (specified when ordering). The secondary side can be directly sampled by resistance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;DIV&gt;Primary input current 1~120A (specified when ordering) Secondary output current 10~40mAㄗ&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CTS100A, CTS200A miniature current transformers&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTY500,CTY600 Miniature anti DC shunt current transformer </title>
           <link>http://www.91way.com/info_en/10038.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:45</pubDate>
           <comments></comments>
           <description>Technical features of CTY500 and CTY600 miniature anti DC shunt current transformers:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Model number&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;CTY500&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;CTY600&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Physical appearance picture&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125215425288.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 230px; WIDTH: 230px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of CTY500 and CTY600 miniature anti DC shunt current transformers&quot; src=&quot;/upload2009/200911/20091125215425288.jpg&quot; width=230 height=230&gt;&lt;/A&gt;&lt;A href=&quot;/upload2009/200911/2009112521524743.jpg&quot; target=_blank&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125215212443.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 142px; WIDTH: 142px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of CTY500 and CTY600 miniature anti DC shunt current transformers&quot; src=&quot;/upload2009/200911/20091125215212443.jpg&quot; width=142 height=142&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Application scenarios&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Rated input&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;100A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;200A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;rated output&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;20mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;40mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;accuracy class&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Maximum phase shift&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;10 ＊&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;5 ＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;load resistor&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;5/10/20/100 次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;5/10/20/100 次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;power frequency withstand voltage&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=510 colSpan=2&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;overload capacity&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;100A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;200A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Normal working environment&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=510 colSpan=2&gt;
&lt;P&gt;Environmental temperature: -25~60&lt;/FONT&gt;⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/FONT&gt;&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: altitude 2000M and below&lt;/FONT&gt;(For applications in high-altitude areas, please specify when placing an order)&lt;/FONT&gt;)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132&gt;
&lt;P&gt;Appearance and installation diagram&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125215239841.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 158px; WIDTH: 225px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY500, CTY600 miniature anti DC shunt current transformer installation size 1&quot; src=&quot;/upload2009/200911/20091125215239841.jpg&quot; width=225 height=158&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125215246485.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 178px; WIDTH: 223px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation size 2 for CTY500 and CTY600 miniature anti DC shunt current transformers&quot; src=&quot;/upload2009/200911/20091125215246485.jpg&quot; width=223 height=178&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125215253604.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 161px; WIDTH: 169px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY500, CTY600 miniature anti DC shunt current transformer installation size 3&quot; src=&quot;/upload2009/200911/20091125215253604.jpg&quot; width=169 height=161&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112521534694.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 146px; WIDTH: 170px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY500, CTY600 miniature anti DC shunt current transformer installation size 4&quot; src=&quot;/upload2009/200911/2009112521534694.jpg&quot; width=170 height=146&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P&gt;Reminder&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;Primary input current 1~100A&lt;/FONT&gt;(Specify when ordering)&lt;/FONT&gt;ㄘSecondary output current of 1-20mA&lt;/FONT&gt;(Specify when ordering)&lt;/FONT&gt;ㄘSecondary direct resistance sampling&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;P&gt;Primary input current 1-200A&lt;/FONT&gt;(Specify when ordering)&lt;/FONT&gt;ㄘSecondary output current 1~40mA&lt;/FONT&gt;(Specify when ordering)&lt;/FONT&gt;ㄘSecondary direct resistance sampling&lt;/FONT&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;/P&gt;
&lt;P&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125215318148.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 132px; WIDTH: 308px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY500, CTY600 miniature anti DC shunt current transformer model description&quot; src=&quot;/upload2009/200911/20091125215318148.jpg&quot; width=308 height=132&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTY105A,CTY205A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10037.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:36</pubDate>
           <comments></comments>
           <description>Characteristics of CTY105A and CTY205A miniature current transformers:&lt;BR&gt;&lt;BR&gt;1. Active type, customizable input/output current&lt;BR&gt;2. Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;3. High electromagnetic isolation, high precision, and no drift&lt;BR&gt;4. ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;CTY105A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;CTY205A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Application scenarios&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;Printed circuit board direct soldering type&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;Printed circuit board direct soldering type&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Rated input&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;5A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;rated output&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;2.5mA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;2.5mA&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;accuracy class&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;0.1%&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;0.1%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Maximum phase shift&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;10∩&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;5∩&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;load resistor&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;5/10/20/100次&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;5/10/20/500次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;power frequency withstand voltage&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=511 colSpan=2&gt;
&lt;DIV align=center&gt;3000V/50Hz/1min&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;overload capacity&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;50A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;120A&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;DIV align=center&gt;Normal working environment&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=511 colSpan=2&gt;
&lt;DIV&gt;Environmental temperature: -25~60 ⊥&lt;/DIV&gt;
&lt;DIV&gt;Humidity: 5%~95%&lt;/DIV&gt;
&lt;DIV&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132&gt;
&lt;DIV align=center&gt;Appearance and installation diagram&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125213120676.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 196px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY105A, CTY205A Miniature Current Transformer Installation Size 1&quot; src=&quot;/upload2009/200911/20091125213120676.jpg&quot; width=196 height=170&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125213127601.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 175px; WIDTH: 216px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CTY105A and CTY205A miniature current transformers 2&quot; src=&quot;/upload2009/200911/20091125213127601.jpg&quot; width=216 height=175&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125213137488.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 115px; WIDTH: 179px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY105A, CTY205A Miniature Current Transformer Installation Size 3&quot; src=&quot;/upload2009/200911/20091125213137488.jpg&quot; width=179 height=115&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=255&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125213149636.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 139px; WIDTH: 186px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CTY105A, CTY205A miniature current transformers 4&quot; src=&quot;/upload2009/200911/20091125213149636.jpg&quot; width=186 height=139&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125213214401.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 132px; WIDTH: 348px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY105A, CTY205A Miniature Current Transformer Model Description&quot; src=&quot;/upload2009/200911/20091125213214401.jpg&quot; width=348 height=132&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;CTY105A, CTY205A miniature current transformers&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTY4120A Miniature anti DC shunt current transformer </title>
           <link>http://www.91way.com/info_en/10036.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:27</pubDate>
           <comments></comments>
           <description>CTY4120A miniature anti DC shunt current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;CTY&amp;gt;4120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;Printed circuit board direct soldering type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;5-120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;2-25mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;5＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=511&gt;
&lt;P align=center&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;160A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=511&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;BR&gt;Humidity: 5%~95%&lt;BR&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132&gt;
&lt;P align=center&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=256&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125212558989.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 188px; WIDTH: 188px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation size 1 of CTY4120A miniature anti DC shunt current transformer&quot; src=&quot;/upload2009/200911/20091125212558989.jpg&quot; width=188 height=188&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/2009112521267812.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 121px; WIDTH: 206px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation size 2 of CTY4120A miniature anti DC shunt current transformer&quot; src=&quot;/upload2009/200911/2009112521267812.jpg&quot; width=206 height=121&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=256&gt;
&lt;P&gt;Primary input current 1-10A (specified when ordering) Secondary output current 1-25mA (specified when ordering)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical features:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTY3100A Miniature anti DC shunt current transformer </title>
           <link>http://www.91way.com/info_en/10035.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:17</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;CTY3100A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;Printed circuit board direct soldering type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;5-100A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;2-20mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;10＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=511&gt;
&lt;P align=center&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=511&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=132&gt;
&lt;P align=center&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=256&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125212144493.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 174px; WIDTH: 169px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Appearance and installation dimensions of CTY3100A miniature anti DC shunt current transformer&quot; src=&quot;/upload2009/200911/20091125212144493.jpg&quot; width=169 height=174&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=256&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125212159265.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 154px; WIDTH: 198px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CTY3100A miniature anti DC shunt current transformer&quot; src=&quot;/upload2009/200911/20091125212159265.jpg&quot; width=198 height=154&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=132&gt;
&lt;P align=center&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=256&gt;
&lt;P&gt;Primary input current 1-100A (specified when ordering) Secondary output current 1-20mA (specified when ordering)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical characteristics:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125212221154.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 306px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model description of CTY3100A miniature anti DC shunt current transformer&quot; src=&quot;/upload2009/200911/20091125212221154.jpg&quot; width=306 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CTY610A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10023.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:45:08</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;CTY610A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;500A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;10＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=508&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;1000A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=508&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=135&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125155248186.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 219px; WIDTH: 275px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CTY610A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125155248186.jpg&quot; width=275 height=219&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125155258403.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 167px; WIDTH: 263px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CTY610A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125155258403.jpg&quot; width=263 height=167&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;The input current of the primary side is 1-1000A (specified when ordering), and the output current of the secondary side is 1010mA~1A (specified when ordering). The secondary side can be directly sampled by resistance&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical characteristics:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112515535479.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 306px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CTY610A Miniature Current Transformer Model Description&quot; src=&quot;/upload2009/200911/2009112515535479.jpg&quot; width=306 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT640A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10022.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:59</pubDate>
           <comments></comments>
           <description>CT640A Miniature Current Transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;CT640A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;Fixed terminal output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;300A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;5＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;5次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=508&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;800A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=508&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;BR&gt;Humidity: 5%~95%&lt;BR&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=135&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125154736255.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 216px; WIDTH: 274px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CT640A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125154736255.jpg&quot; width=274 height=216&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125154747544.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 175px; WIDTH: 255px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT640A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125154747544.jpg&quot; width=255 height=175&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=135&gt;
&lt;P&gt;hint&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;P&gt;Primary input current 1~800A (specified when ordering) Secondary output current 1~5A (specified when ordering)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Technical features of CT640A miniature current transformer:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT480A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10021.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:50</pubDate>
           <comments></comments>
           <description>CT480A Miniature Current Transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;CT480A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;50A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;20mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;10＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;80A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;BR&gt;Humidity: 5%~95%&lt;BR&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=138&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112515409356.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 202px; WIDTH: 221px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CT480A miniature current transformer&quot; src=&quot;/upload2009/200911/2009112515409356.jpg&quot; width=221 height=202&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125154018336.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 103px; WIDTH: 185px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT480A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125154018336.jpg&quot; width=185 height=103&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Primary input current 1~80A (specified when ordering) Secondary output current 1~40mA (specified when ordering) Secondary direct resistance sampling is available&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical features:&lt;BR&gt;&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125154026190.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 308px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CT480A Miniature Current Transformer Model Description&quot; src=&quot;/upload2009/200911/20091125154026190.jpg&quot; width=308 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT305A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10020.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:42</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;CT305A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;10＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;50A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;BR&gt;Humidity: 5%~95%&lt;BR&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=138&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125153354310.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 194px; WIDTH: 188px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CT305A miniature current transformer&quot; src=&quot;/upload2009/200911/20091125153354310.jpg&quot; width=188 height=194&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112515343688.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 100px; WIDTH: 184px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT305A miniature current transformer&quot; src=&quot;/upload2009/200911/2009112515343688.jpg&quot; width=184 height=100&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;The input current of the primary side is 1-50A (specified when ordering), and the output current of the secondary side is 1-20mA (specified when ordering). The secondary side can be directly sampled by resistance&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Technical features:&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125153414181.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 308px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Selection Instructions for CT305A Miniature Current Transformer&quot; src=&quot;/upload2009/200911/20091125153414181.jpg&quot; width=308 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT5100 Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10019.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:33</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;CT5100 Miniature Current Transformer&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;CT5100A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Physical appearance picture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125152146982.jpg&quot; target=_blank&gt;&lt;IMG border=0 src=&quot;/upload2009/200911/20091125152146982.jpg&quot;&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;100A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;40mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;120A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=505&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=138&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125152157700.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 178px; WIDTH: 198px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CT5100 miniature current transformer&quot; src=&quot;/upload2009/200911/20091125152157700.jpg&quot; width=198 height=178&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=168&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125152214883.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 98px; WIDTH: 198px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT5100 miniature current transformer&quot; src=&quot;/upload2009/200911/20091125152214883.jpg&quot; width=198 height=98&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=138&gt;
&lt;P&gt;hint&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=168&gt;
&lt;P&gt;The input current of the primary side can be 1-10A (specified when ordering), and the output current of the secondary side can be 1-50mA (specified when ordering)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical characteristics:&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;/upload2009/200911/20091125152233236.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 308px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Selection Instructions for CT5100 Miniature Current Transformer&quot; src=&quot;/upload2009/200911/20091125152233236.jpg&quot; width=308 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT264A,CT274A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/10018.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:24</pubDate>
           <comments></comments>
           <description>Micro current transformer - CT series&lt;BR&gt;&lt;BR&gt;Technical features:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;CT264A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;CT274A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Physical appearance picture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/2009112514584355.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 182px; WIDTH: 150px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of CT264A and CT274A miniature current transformers&quot; src=&quot;/upload2009/200911/2009112514584355.jpg&quot; width=150 height=182&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091125145812942.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 174px; WIDTH: 150px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of CT264A and CT274A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125145812942.jpg&quot; width=150 height=174&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;Lead output type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;5A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;2.5mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;2.5mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;10＊&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;5＊&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;5/10/20/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=499 colSpan=2&gt;
&lt;P align=center&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;50A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P align=center&gt;80A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P align=center&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=499 colSpan=2&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=136&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125145843658.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 165px; WIDTH: 134px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CT264A, CT274A miniature current transformers with external dimensions of 1&quot; src=&quot;/upload2009/200911/20091125145843658.jpg&quot; width=134 height=165&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125145850451.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 212px; WIDTH: 263px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CT264A, CT274A miniature current transformers with external dimensions of 2&quot; src=&quot;/upload2009/200911/20091125145850451.jpg&quot; width=263 height=212&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=249&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125145859767.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 119px; WIDTH: 163px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CT264A, CT274A Miniature Current Transformer Installation Size 1&quot; src=&quot;/upload2009/200911/20091125145859767.jpg&quot; width=163 height=119&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125145910658.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 168px; WIDTH: 178px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation size 2 for CT264A and CT274A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125145910658.jpg&quot; width=178 height=168&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=136&gt;
&lt;P&gt;Kind reminder&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P&gt;The input current of the primary side is 1-50A (specified when ordering), and the output current of the secondary side is 1-20mA (specified when ordering). The secondary side can be directly sampled by resistance or standard amplification circuit can be used&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=249&gt;
&lt;P&gt;The input current of the primary side is 1~80A (specified when ordering), and the output current of the secondary side is 1~20mA (specified when ordering). The secondary side can be directly sampled by resistance or used&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091125145921609.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 132px; WIDTH: 308px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Selection instructions for CT264A and CT274A miniature current transformers&quot; src=&quot;/upload2009/200911/20091125145921609.jpg&quot; width=308 height=132&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT286A,CT254A Miniature current transformer </title>
           <link>http://www.91way.com/info_en/9972.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:15</pubDate>
           <comments></comments>
           <description>CT286A, CT254A miniature current transformers&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;Model number&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;CT254A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;CT286A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;Physical appearance picture&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091124213713698.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 150px; WIDTH: 164px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of CT286A and CT254A miniature current transformers&quot; src=&quot;/upload2009/200911/20091124213713698.jpg&quot; width=164 height=150&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2009/200911/20091124213723469.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 120px; WIDTH: 120px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of CT286A and CT254A miniature current transformers&quot; src=&quot;/upload2009/200911/20091124213723469.jpg&quot; width=120 height=120&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;Application scenarios&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;Printed circuit board direct soldering type&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;Printed circuit board direct soldering type&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;Rated input&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;5A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;150A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;rated output&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;2.5mA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;2.5mA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;accuracy class&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;0.1%&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;Maximum phase shift&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;10'&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;5'&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;load resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;/100次&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;/100次&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;power frequency withstand voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=509 colSpan=2&gt;
&lt;P align=center&gt;3000V/50Hz/1min&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P align=center&gt;overload capacity&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;100A&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P align=center&gt;80A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;Normal working environment&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=509 colSpan=2&gt;
&lt;P&gt;Environmental temperature: -25~60 ⊥&lt;/P&gt;
&lt;P&gt;Humidity: 5%~95%&lt;/P&gt;
&lt;P&gt;Atmospheric pressure: at an altitude of 2000M or below (for use in high-altitude areas, please specify when placing an order)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=134&gt;
&lt;P&gt;Appearance and installation diagram&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;&lt;A href=&quot;/upload2009/200911/20091124213741676.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 134px; WIDTH: 185px; FILTER: none&quot; border=0 hspace=0 alt=&quot;CT286A, CT254A Miniature Current Transformer Installation Size 1&quot; src=&quot;/upload2009/200911/20091124213741676.jpg&quot; width=185 height=134&gt;&lt;/A&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091124213749296.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 139px; WIDTH: 205px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation size 2 for CT286A and CT254A miniature current transformers&quot; src=&quot;/upload2009/200911/20091124213749296.jpg&quot; width=205 height=139&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112421380637.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 174px; WIDTH: 197px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT286A and CT254A miniature current transformers 3&quot; src=&quot;/upload2009/200911/2009112421380637.jpg&quot; width=197 height=174&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=254&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/2009112421389572.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 197px; WIDTH: 225px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT286A and CT254A miniature current transformers 4&quot; src=&quot;/upload2009/200911/2009112421389572.jpg&quot; width=225 height=197&gt;&lt;/A&gt;&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=134&gt;
&lt;P&gt;hint&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;P&gt;The input current of the primary side is 1-100A (specified when ordering), and the output current of the secondary side is 1-20mA (specified when ordering). The secondary side can be directly sampled by resistance or standard amplification circuit can be used. (See Figure P...)&lt;/P&gt;&lt;/TD&gt;
&lt;TD vAlign=top width=254&gt;
&lt;P&gt;The input current of the primary side can be 1~80A (specified when ordering), and the output current of the secondary side can be 1~16mA (specified when ordering). The secondary side can be directly sampled by resistance or standard amplification circuit can be used. (See Figure P...)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P&gt;&lt;BR&gt;Technical features of CT286A and CT254A miniature current transformers:&lt;BR&gt;Active type, customizable input/output current&lt;BR&gt;Compact and lightweight, easy to solder directly onto printed circuit boards&lt;BR&gt;High electromagnetic isolation, high precision, and no drift&lt;BR&gt;&lt;BR&gt;ABS flame retardant shell, fully resin sealed, high pressure resistance, high reliability&lt;/P&gt;
&lt;P&gt;&lt;A href=&quot;/upload2009/200911/20091124213839166.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 129px; WIDTH: 307px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Model Description of CT286A and CT254A Miniature Current Transformers&quot; src=&quot;/upload2009/200911/20091124213839166.jpg&quot; width=307 height=129&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT21 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4949.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:44:06</pubDate>
           <comments></comments>
           <description>CT21 series miniature current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]PT35 series miniature voltage transformers </title>
           <link>http://www.91way.com/info_en/4944.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:58</pubDate>
           <comments></comments>
           <description>Product specifications: 100V/1V, 100V/1V * 2&lt;BR&gt;Product advantages: high precision, wide linearity&lt;BR&gt;Main Market: Instruments and Meters&lt;BR&gt;&lt;BR&gt;PT35 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]PT01-4 series miniature voltage transformers </title>
           <link>http://www.91way.com/info_en/4943.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:47</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Input voltage: 100V, 150V, 220V, 380V, 450V (0--1000V)&lt;BR&gt;Output voltage: 0.1V (100 ohm load)&lt;BR&gt;&lt;BR&gt;When in use, a current limiting resistor should be added to the primary to convert the primary current into milliampere level current, and the secondary can obtain any voltage through an operational amplifier. Easy to use, completely electrically isolated.&lt;BR&gt;Belonging to current type voltage transformer&lt;BR&gt;Current ratio: 1 mA/1mA&lt;BR&gt;2mA/2mA&lt;BR&gt;High precision, 0.1 level&lt;BR&gt;&lt;BR&gt;compact size&lt;BR&gt;PT01-3: Length x Width x Height=20.7x19.2x20.7 (Unit: mm)&lt;BR&gt;Pin distance: 12.7 * 10.2&lt;BR&gt;Electrical isolation, withstand voltage up to 2500V&lt;BR&gt;Instruments and meters, power transmitters, intelligent high-voltage switches&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/200941143438569.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 304px; WIDTH: 384px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of PT01-4 series miniature voltage transformer&quot; src=&quot;/uploadfiles/200904/200941143438569.jpg&quot; width=384 height=304&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;PT01-4 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]PT01-3 series miniature voltage transformers </title>
           <link>http://www.91way.com/info_en/4942.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:37</pubDate>
           <comments></comments>
           <description>&lt;P&gt;PT01-3 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;Product specifications: Input voltage: 100V, 150V, 220V, 380V, 450V (0-1000V)&lt;BR&gt;Output voltage: 0.1V (100 ohm load)&lt;BR&gt;&lt;BR&gt;When in use, a current limiting resistor should be added to the primary to convert the primary current into milliampere level current, and the secondary can obtain any voltage through an operational amplifier. Easy to use, completely electrically isolated.&lt;BR&gt;Belonging to current type voltage transformer&lt;BR&gt;Current ratio: 1 mA/1mA&lt;BR&gt;2mA/2mA&lt;BR&gt;Product advantages: High precision, 0.1 level&lt;BR&gt;&lt;BR&gt;compact size&lt;BR&gt;PT01-3: Length x Width x Height=20.7x19.2x20.7 (Unit: mm)&lt;BR&gt;Pin distance: 12.7 * 10.2&lt;BR&gt;Electrical isolation, withstand voltage up to 2500V&lt;BR&gt;Main markets: Instruments and meters, power transmitters, intelligent high-voltage switches&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200941143258865.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 304px; WIDTH: 384px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of PT01-3 series miniature voltage transformer&quot; src=&quot;/uploadfiles/200904/200941143258865.jpg&quot; width=384 height=304&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;PT01-3 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]PT01-2 series miniature voltage transformers </title>
           <link>http://www.91way.com/info_en/4941.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:28</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: Input voltage: 100V, 150V, 220V, 380V, 450V (0-1000V)&lt;BR&gt;Output voltage: 0.4V (200 ohm load)&lt;BR&gt;Length x width x height=27x26.4x15.7 (unit: mm)&lt;BR&gt;&lt;BR&gt;Pin distance: 22.8 * 16&lt;BR&gt;Product advantages: Accuracy level: 0.1&lt;BR&gt;&lt;BR&gt;Voltage isolation&lt;BR&gt;When in use, a current limiting resistor should be added to the primary level&lt;BR&gt;Current ratio: 1mA/1mA; 2mA/2mA&lt;BR&gt;Main markets: Instruments and meters, power transmitters, intelligent high-voltage switches&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/20094114319962.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 352px; WIDTH: 352px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of PT01-2 series miniature voltage transformers&quot; src=&quot;/uploadfiles/200904/20094114319962.jpg&quot; width=352 height=352&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;PT01-2 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]PT01-1 series miniature voltage transformers </title>
           <link>http://www.91way.com/info_en/4940.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:19</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: Input voltage: 100V, 150V, 220V, 380V, 450V&lt;BR&gt;Output voltage: 0.1V&lt;BR&gt;Length x width x height=26.7x17.7x28.4 (unit: mm)&lt;BR&gt;&lt;BR&gt;Pin distance: 20 * 10&lt;BR&gt;&lt;BR&gt;Please add a current limiting resistor when using,&lt;BR&gt;1mA/1mA; 2mA/2mA&lt;BR&gt;Product advantages: Accuracy level: 0.1&lt;BR&gt;The linearity is up to 0.1%, with a difference of less than 5 '&lt;BR&gt;Main markets: Instruments and meters, power transmitters, intelligent high-voltage switches, voltage measurement&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/200941142748339.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 352px; WIDTH: 432px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of PT01-1 series miniature voltage transformer&quot; src=&quot;/uploadfiles/200904/200941142748339.jpg&quot; width=432 height=352&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;PT01-1 series miniature voltage transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT17 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4939.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:10</pubDate>
           <comments></comments>
           <description>CT17 series miniature current transformer specifications: CT17-100:40A/40mA;&lt;BR&gt;&lt;BR&gt;CT17-200:40A/20mA; 20A/10mA;&lt;BR&gt;Product advantages: ID/OD * H &amp;pound; &amp;ordm; 10.4/26.5 * 15&lt;BR&gt;pin space:15.0/4.2*10.8&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT15-5 series miniature precision current transformer </title>
           <link>http://www.91way.com/info_en/4938.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:43:01</pubDate>
           <comments></comments>
           <description>Current ratio: 5A/2.5mA&lt;BR&gt;&lt;BR&gt;Size specifications:&lt;BR&gt;Length x width x height=19.2X17.6x17.6 (unit: mm)&lt;BR&gt;&lt;BR&gt;Through hole: 朴 4.0&lt;BR&gt;Pin distance: 12.5/10.8 * 16.4&lt;BR&gt;Product specifications: Current ratio: 5A/2.5mA&lt;BR&gt;&lt;BR&gt;CT15-5 series miniature precision current transformer&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT15-4 series miniature precision current transformer </title>
           <link>http://www.91way.com/info_en/4937.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:52</pubDate>
           <comments></comments>
           <description>&lt;P&gt;CT15-4 series miniature precision current transformer&lt;BR&gt;&lt;BR&gt;Product specifications: Current ratio: 5A/1mA, 5A/2mA, 5A/2.5mA&lt;BR&gt;1A/2mA,&amp;nbsp;1A/2.5mA&lt;BR&gt;Size specifications:&lt;BR&gt;Length x width x height=21.4x19.7x19 (unit: mm)&lt;BR&gt;&lt;BR&gt;Through hole: 朴 3.4&lt;BR&gt;Pin distance: 11.2//13.2 * 16.4&lt;BR&gt;Product advantages: High precision, 0.1, 0.2&lt;BR&gt;Main markets: Instruments and meters, power transmitters, automatic control systems&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/20094182641572.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 384px; WIDTH: 448px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT15-4 series miniature precision current transformer&quot; src=&quot;/uploadfiles/200904/20094182641572.jpg&quot; width=448 height=384&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CT15-4 series miniature precision current transformer&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT14 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4936.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:44</pubDate>
           <comments></comments>
           <description>CT14 series miniature current transformer&lt;BR&gt;&lt;BR&gt;CT14 : 5A/5mA&lt;BR&gt;5A/2.5mA&lt;BR&gt;5A/2mA&lt;BR&gt;&lt;BR&gt;Product specifications: Size: Inner diameter/Outer diameter * Thickness (mm)&lt;BR&gt;4.8/16.8*10&lt;BR&gt;Foot distance: 12.5 (mm),&lt;BR&gt;Product advantages: Small size&lt;BR&gt;Main markets: instrumentation, electrical measuring instruments, automatic control, power systems&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT11 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4935.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: Current ratio:&lt;BR&gt;5A/5mA,5A/7.5mA,10A/5mA,10A/10mA,20A/10mA,25A/10mA,30A/10mA; 50A/10mA; 50A/50mA&lt;BR&gt;&lt;BR&gt;&lt;BR&gt;Mechanical dimensions: 8.4/30 * 16.5&lt;BR&gt;Product advantages: Accuracy level: 0.1, 0.2&lt;BR&gt;Main markets: Instruments and meters, power transmitters, and electricity meters&lt;BR&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/2009418224836.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 304px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT11 series miniature current transformers&quot; src=&quot;/uploadfiles/200904/2009418224836.jpg&quot; width=400 height=304&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CT11 series miniature current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT10 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4934.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:26</pubDate>
           <comments></comments>
           <description>CT10 series miniature current transformer&lt;BR&gt;&lt;BR&gt;Product specifications: CT10-1:5A/2.5mA, 5A/2mA, 10A/4mA;&lt;BR&gt;&lt;BR&gt;CT10-2:20A/8mA,40A/16mA,30A/15m:&lt;BR&gt;CT10-3:60A/24mA,50A/20mA,100A/50mA;&lt;BR&gt;CT10-4:200A/100mA,150A/75mA;&lt;BR&gt;&lt;BR&gt;Mechanical dimensions: (ID/OD * HT) (mm)&lt;BR&gt;CT10-1: 6.9/23.5*11&lt;BR&gt;CT10-2: 9.0/26*17&lt;BR&gt;CT10-3: 12.8/37.5*14&lt;BR&gt;CT10-4: 18.6/50*20&lt;BR&gt;&lt;BR&gt;Foot distance: (mm)&lt;BR&gt;CT10-1ㄩ15.2 / 19* 10&lt;BR&gt;CT10-2: 15.2 / 19* 16&lt;BR&gt;CT10-3ㄩ25.4 / 33* 13&lt;BR&gt;CT10-4: 30 / 37.5* 19&lt;BR&gt;Product advantages: Accuracy level: 0.1, 0.2&lt;BR&gt;&lt;BR&gt;The CT10 series miniature current transformer can achieve a linearity of 0.1% and a phase difference of less than 5＆&lt;BR&gt;&lt;BR&gt;Main markets: Instruments and meters, power transmitters, automatic control
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/20094182038472.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 236px; WIDTH: 205px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of CT10 series miniature current transformers&quot; src=&quot;/uploadfiles/200904/20094182038472.gif&quot; width=205 height=236&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT09 type miniature current transformer </title>
           <link>http://www.91way.com/info_en/4933.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:17</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: Current ratio:&lt;BR&gt;&lt;BR&gt;CT09-100:5A/5mA; 10A/10mA;&lt;BR&gt;CT09-200:10A/5mA;; 20A/10mA;&lt;BR&gt;CT09-250:25A/10mA; 5A/2mA&lt;BR&gt;CT09-300:30A/10mA;&lt;BR&gt;&lt;BR&gt;Size: Inner diameter/outer diameter * thickness (mm)&lt;BR&gt;7.0/23.5*12.5&lt;BR&gt;Foot distance: 15.2/19 * 11 (mm),&lt;BR&gt;Pin: 1 mm&lt;BR&gt;Another lead output method available:&lt;BR&gt;&lt;BR&gt;Product advantages: Accuracy level: 0.1; zero point two&lt;BR&gt;&lt;BR&gt;Can achieve a linearity of 0.1%,&lt;BR&gt;Difference less than 5＆&lt;BR&gt;Main markets: instrumentation, electrical measuring instruments, automatic control, power systems&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/20094181848558.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 288px; WIDTH: 352px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT09 miniature current transformer&quot; src=&quot;/uploadfiles/200904/20094181848558.jpg&quot; width=352 height=288&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CT09 type miniature current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT31 type miniature current transformer </title>
           <link>http://www.91way.com/info_en/4932.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:08</pubDate>
           <comments></comments>
           <description>CT31 miniature current transformer specifications: 1.5A (6)/5mA, 1.5A (6)/7.5mA, 3A (9)/5mA&lt;BR&gt;&lt;BR&gt;Including three components and two components&lt;BR&gt;&lt;BR&gt;Size:&lt;BR&gt;99*23*32 (in:mm)&lt;BR&gt;Product advantages: Accuracy level: 0.1 level&lt;BR&gt;&lt;BR&gt;High precision current transformers with precision levels of 0.05 and 0.02; Input 1.5A (6), output 50 (200) mV, non-linear ratio difference&amp;lt;&amp;lt;0.02%, non-linear angle difference&amp;lt;&amp;lt;0.6 points&lt;BR&gt;&lt;BR&gt;Main markets: Electronic energy meters, IC card energy meters, 0.2S energy meters&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT19-1 series miniature current transformers </title>
           <link>http://www.91way.com/info_en/4931.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:42:00</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: 5A (20)/5mA, 10A (40)/5mA,&lt;BR&gt;5A(30)/5mA,5A(30)/3.33mA,&lt;BR&gt;10A(40)/10mA,10A(60)/5mA,&lt;BR&gt;10A(80)/5mA,10A(100)/5mA,&lt;BR&gt;20A(80)/20mA,20(100)/20mA,&lt;BR&gt;15A(60)/15mA,1.5A(6)/5mA,&lt;BR&gt;1.5A(9)/5mA,1.5A(6)/7.5mA,&lt;BR&gt;2.5A(10)/5mA;&lt;BR&gt;&lt;BR&gt;Mechanical dimensions: 30.6 * 33 * 32.5 (mm)&lt;BR&gt;&lt;BR&gt;Mainly used for electronic energy meters, prepaid, and multi rate energy meters&lt;BR&gt;Product advantages: Accuracy level: 0.1, 0.2&lt;BR&gt;&lt;BR&gt;High precision current transformers with precision levels of 0.05 and 0.02; Input 1.5A (6), output 50 (200) mV, non-linear difference&amp;lt;&amp;lt;0 02%, non-linear angle difference&amp;lt;&amp;lt;0.6 points&lt;BR&gt;&lt;BR&gt;Main markets: Electronic energy meters, IC card meters&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200904/2009418936554.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 304px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT19-1 series miniature current transformers&quot; src=&quot;/uploadfiles/200904/2009418936554.jpg&quot; width=400 height=304&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CT19-1 series miniature current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT08 type miniature current transformer </title>
           <link>http://www.91way.com/info_en/4930.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:41:51</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product specifications: Current ratio:&lt;BR&gt;1mA/1mA; &amp;nbsp;2mA/1mA; &amp;nbsp;10mA/1mA; 100mA/1mA;&lt;BR&gt;1A/1mA; 1A/2mA; 2A/1mA;&lt;BR&gt;2mA/2mA&lt;BR&gt;5mA/5mA; &amp;nbsp;10mA/5mA; &amp;nbsp;50mA/5mA&lt;BR&gt;20mA/10mA; 20mA/20mA; 50mA/10mA; 100mA/10mA; &amp;nbsp;&lt;BR&gt;5A/2mA; &amp;nbsp;5A/2.5mA; 20A/10mA&lt;BR&gt;&lt;BR&gt;Primary current: 1mA -1 A, any suitable, with built-in winding&lt;BR&gt;5A or above is considered as external piercing&lt;BR&gt;&lt;BR&gt;Product advantages: length x width x height=27x26.4x17.5 (unit: mm)&lt;BR&gt;&lt;BR&gt;Pin distance: 22.8 * 16&lt;BR&gt;&lt;BR&gt;Through hole: 6mm&lt;BR&gt;Accuracy level: 0.1&lt;BR&gt;&lt;BR&gt;Instrumentation, transmitters, intelligent control series&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200904/2009418738303.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 352px; WIDTH: 352px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of CT08 miniature current transformer&quot; src=&quot;/uploadfiles/200904/2009418738303.jpg&quot; width=352 height=352&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;CT08 type miniature current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT20 type miniature current transformer </title>
           <link>http://www.91way.com/info_en/4929.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:41:42</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=3 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;Product specifications:&lt;/TD&gt;
&lt;TD&gt;Model Initial Current (A)/Secondary Current (A)&lt;BR&gt;Type IP (A) / Is (A)&lt;BR&gt;CT20-50 50 / 0.1 ㄗ0.5,1 or 5)&lt;BR&gt;CT20-100 100 / 0.1 ㄗ0.5,1 or 5)&lt;BR&gt;CT20-150 150 / 0.1 ㄗ0.5,1 or 5)&lt;BR&gt;CT20-200 200 / 0.1 ㄗ0.5,1 or 5)&lt;BR&gt;CT20-250 250 / 0.1 ㄗ0.5,1 or 5)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Product advantages:&lt;/TD&gt;
&lt;TD&gt;Accuracy:&lt;BR&gt;0.5 ; zero point two&lt;BR&gt;Mechanical dimensions: 60 * 33 * 80&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Main markets:&lt;/TD&gt;
&lt;TD&gt;Automatic control, overload protection, power system.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;CT20 type miniature current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CA series current transformers </title>
           <link>http://www.91way.com/info_en/4928.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:41:33</pubDate>
           <comments></comments>
           <description>&lt;P&gt;&lt;A href=&quot;/uploadfiles/200903/200933122368437.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 1500px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions and Technical Parameters of CA Series Current Transformers&quot; src=&quot;/uploadfiles/200903/200933122368437.jpg&quot; width=680 height=1500&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=center&gt;CA series current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]A250 type active transient current transformer </title>
           <link>http://www.91way.com/info_en/3576.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:41:25</pubDate>
           <comments></comments>
           <description>Technical characteristics and related parameters of A250 active transient current transformer:&lt;BR&gt;Characteristics:&lt;BR&gt;&lt;BR&gt;The A250 active transient current transformer does not contain ferromagnetic materials, has no hysteresis effect, and has almost zero phase error; There is no magnetic saturation phenomenon, so the measurement range can range from several amperes to several hundred kiloamperes of current; The structure is simple and there is no direct circuit connection between it and the measured current; The response bandwidth is 0.1HZ-1MHz. Compared with traditional transformers with iron cores, it has a wide measurement range, high accuracy, stability and reliability, response frequency bandwidth, as well as measurement and relay protection functions. It is small in size, light in weight, safe, and meets environmental protection requirements. Due to the characteristics of real-time current measurement, fast response speed, no saturation, and almost no phase error, this type of current transformer can be applied in situations where signal distortion is severe, such as relay protection, thyristor rectification, frequency conversion speed regulation, resistance welding, etc.&lt;BR&gt;&lt;BR&gt;Disadvantages:&lt;BR&gt;Due to limitations in manufacturing processes and materials, the accuracy of a normal 50Hz sine wave is not as good as that of conventional transformers. It can reach a maximum level of 0.2.&lt;BR&gt;&lt;BR&gt;Parameters:&lt;BR&gt;Input current: 0-300A&lt;BR&gt;Output voltage: current differential di/dt 1mV5%/A (50Hz)&lt;BR&gt;Response frequency: 1Hz~500KHz&lt;BR&gt;Linearity: 0.5%, 0.2%&lt;BR&gt;Appearance: 17X16X19 5 through-hole mm&lt;BR&gt;&lt;BR&gt;Mainly used for measuring severely distorted sine wave current, impulse current, and pulse current (cannot measure pure DC current).&lt;BR&gt;Note: YX250 series transformers can be customized according to user requirements.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Miniature transformer]CT-0.3(1.5)-5BA series current transformers </title>
           <link>http://www.91way.com/info_en/405.html</link>
           <author></author>
           <guid></guid>
           <category>Miniature transformer</category>
           <pubDate>2026-6-15 20:41:16</pubDate>
           <comments></comments>
           <description>&lt;DIV align=left&gt;CT-0.3 (1.5) -5BA series current transformer&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;appearance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=521 colSpan=27&gt;
&lt;DIV align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2010/201005/20100519113425198.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 341px; WIDTH: 218px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of CT 0.3 (1.5) -5BA series current transformers&quot; src=&quot;/upload2010/201005/20100519113425198.jpg&quot; width=218 height=341&gt;&lt;/A&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=84&gt;
&lt;DIV align=center&gt;Basic Parameters&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=4&gt;
&lt;DIV align=center&gt;Rated once&lt;/DIV&gt;
&lt;DIV align=center&gt;current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=101 colSpan=5&gt;
&lt;DIV align=center&gt;Rated secondary current (mA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=5&gt;
&lt;DIV align=center&gt;rated load&lt;/DIV&gt;
&lt;DIV align=center&gt;Rbㄗ次ㄘ&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=4&gt;
&lt;DIV align=center&gt;Maximum current (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=5&gt;
&lt;DIV align=center&gt;accuracy class&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=101 colSpan=4&gt;
&lt;DIV align=center&gt;remark&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=80 colSpan=4&gt;
&lt;DIV align=center&gt;zero point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=101 colSpan=5&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=5&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=4&gt;
&lt;DIV align=center&gt;one point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=80 colSpan=5&gt;
&lt;DIV align=center&gt;zero point one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=101 colSpan=4&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=84&gt;
&lt;DIV align=center&gt;Error limit&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3 width=48 colSpan=2&gt;
&lt;DIV align=center&gt;Accuracy level&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=113 colSpan=6&gt;
&lt;DIV align=center&gt;Current error &#177; (%)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=360 colSpan=19&gt;
&lt;DIV align=center&gt;Phase error &#177; (杓)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=113 colSpan=6&gt;
&lt;DIV align=center&gt;At the following currents&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=360 colSpan=19&gt;
&lt;DIV align=center&gt;At the following currents&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;0.01In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64 colSpan=3&gt;
&lt;DIV align=center&gt;≡0.05In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;0.01In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;0.05In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;0.2In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;1In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;2In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=4&gt;
&lt;DIV align=center&gt;3In&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=69 colSpan=2&gt;
&lt;DIV align=center&gt;Imax&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48 colSpan=2&gt;
&lt;DIV align=center&gt;zero point one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64 colSpan=3&gt;
&lt;DIV align=center&gt;zero point one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=4&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=69 colSpan=2&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=48 colSpan=2&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;zero point four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=64 colSpan=3&gt;
&lt;DIV align=center&gt;zero point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=3&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=48 colSpan=3&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=49 colSpan=4&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=69 colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=521 colSpan=27&gt;
&lt;DIV&gt;Note: (1) Within the current range of 0.2In~Imax, take the average value of the maximum phase difference 汛 max and the minimum phase difference 汛 min, 汛 e. The difference between the phase difference 汛 i and the average value 汛 e at point i operating current is defined as the phase error at point i: 忖 汛 i=汛 i - 汛 e&lt;/DIV&gt;
&lt;DIV align=left&gt;(2) Temperature measurement range: 10 ⊥ to 30 ⊥&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;working environment&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=521 colSpan=27&gt;
&lt;DIV align=center&gt;Temperature: -25 ⊥ to+60 ⊥; Relative humidity: ≒ 95%&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;Main electrical performance&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=521 colSpan=27&gt;
&lt;DIV align=center&gt;The withstand voltage between the primary winding and the secondary winding shall not be less than 3kV, and the insulation resistance shall not be less than 1G 次&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=84&gt;
&lt;DIV align=center&gt;Reference size&lt;/DIV&gt;
&lt;DIV align=center&gt;(mm)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;A&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;B&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;C&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;E&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;F&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;G&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;I&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;J&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;K&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;L&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;M&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;five point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;fifteen point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;six point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;twenty-one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;one hundred and fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;five point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;four point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;fifteen point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;six point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;twenty-four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=3&gt;
&lt;DIV align=center&gt;fourteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37 colSpan=2&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=37&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=84&gt;&lt;/TD&gt;
&lt;TD width=37&gt;&lt;/TD&gt;
&lt;TD width=11&gt;&lt;/TD&gt;
&lt;TD width=26&gt;&lt;/TD&gt;
&lt;TD width=6&gt;&lt;/TD&gt;
&lt;TD width=17&gt;&lt;/TD&gt;
&lt;TD width=15&gt;&lt;/TD&gt;
&lt;TD width=37&gt;&lt;/TD&gt;
&lt;TD width=12&gt;&lt;/TD&gt;
&lt;TD width=20&gt;&lt;/TD&gt;
&lt;TD width=5&gt;&lt;/TD&gt;
&lt;TD width=24&gt;&lt;/TD&gt;
&lt;TD width=14&gt;&lt;/TD&gt;
&lt;TD width=35&gt;&lt;/TD&gt;
&lt;TD width=3&gt;&lt;/TD&gt;
&lt;TD width=37&gt;&lt;/TD&gt;
&lt;TD width=9&gt;&lt;/TD&gt;
&lt;TD width=29&gt;&lt;/TD&gt;
&lt;TD width=6&gt;&lt;/TD&gt;
&lt;TD width=14&gt;&lt;/TD&gt;
&lt;TD width=17&gt;&lt;/TD&gt;
&lt;TD width=31&gt;&lt;/TD&gt;
&lt;TD width=6&gt;&lt;/TD&gt;
&lt;TD width=11&gt;&lt;/TD&gt;
&lt;TD width=26&gt;&lt;/TD&gt;
&lt;TD width=5&gt;&lt;/TD&gt;
&lt;TD width=32&gt;&lt;/TD&gt;
&lt;TD width=37&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;BR&gt;CT 0.3 (1.5) -5BA series current transformer&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
</channel>
</rss>
