<?xml version="1.0" encoding="gb2312"?>
<rss version="2.0">
<channel>
       <title>Shanghai Huabang Industrial Business Network - Low-voltage arrester</title>
       <link>http://www.91way.com</link>
       <description>Low-voltage arrester</description>
       <language>zh-cn</language>
       <generator>Www.91way.com</generator>
       <copyright>Copyright 2011-2012 Www.91way.com, All Rights Reserved</copyright>
       <pubDate>2026-6-21 10:01:33</pubDate>
       <item>
           <title>[Low-voltage arrester]XB-SL-DH Telephone line lightning arrester </title>
           <link>http://www.91way.com/info_en/23526.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:43:14</pubDate>
           <comments></comments>
           <description>Function and application scope:&lt;BR&gt;The XB-SL-DH telephone line lightning arrester is produced using gas discharge tubes, varistors, and imported high-quality fast clamping semiconductor devices. Connected in series at the front end of the communication line interface, it suppresses high voltage pulses on the line and protects backend equipment from damage caused by lightning and industrial surges. With a current carrying capacity of 5KA, it can effectively prevent the data transmission system from being damaged by transient overvoltage caused by electrostatic induction and electromagnetic induction, greatly ensuring the safety of protected equipment. It is the best choice for remote transmission protection of telephone lines. Excellent anti overvoltage characteristics can provide anti-interference protection for communication equipment.&lt;BR&gt;This product is suitable for communication equipment such as fax machines, modems, telephones, and program-controlled switches.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;XB-SL-DH&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;Nominal current capacity (8/20 ¦Ì s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;clamping voltage &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;170/230V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;Insertion wear and tear&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;&amp;lt;0.5dB&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;response time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;&amp;lt;1ns&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;Insert resistor&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;&amp;lt;1 ¦¸&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=347 align=center&gt;
&lt;P align=center&gt;interface method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=346 align=center&gt;
&lt;P align=center&gt;RJ11&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;At the front end of the protected equipment's line, connect the XB-SL-DH telephone line lightning arrester in series, connect the 2-3 input terminal IN to the telephone transmission line, and connect the output terminal OUT to the protected equipment. Make a reliable electrical connection between the lightning arrester grounding terminal and the ground wire.&lt;BR&gt;If it is found that the installed lightning arrester cannot transmit data normally, remove the lightning arrester and directly connect it to the equipment. If it still cannot transmit normally, the lightning arrester is intact and other reasons should be investigated.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]XB-CATV-BNC Video signal lightning arrester </title>
           <link>http://www.91way.com/info_en/23525.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:43:05</pubDate>
           <comments></comments>
           <description>Function and application scope:&lt;BR&gt;The XB-CATV-BNC video signal lightning arrester is produced from imported semiconductor devices, gas discharge tubes, and other components. It has the advantages of fast action time, low insertion loss, accurate clamping, and low output residual voltage. It can effectively suppress overvoltage pulses induced on the signal transmission line of the camera gun and protect video monitoring equipment from damage caused by overvoltage pulses. It is a new generation of video signal protection product.&lt;BR&gt;This product is suitable for video surveillance equipment such as camera guns, video distributors, video matrix switchers, etc.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;XB-CATV-BNC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;Nominal voltage U N&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;-6V/+1V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;Maximum continuous operating voltage&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;-8V/+1.4V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;Nominal discharge current I SN (8/20 ¦Ì s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;2.5kA (core wire/ground) 10kA (shielding/ground)&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;Input/output impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;75¦¸&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;response time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;&amp;lt;1ns&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;insertion loss&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;¡Ü 0.5dB&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;bandwidth&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;200MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;Data transmission rate&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;16Mbps&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P&gt;interface method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P&gt;BNC&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;The grounding resistance should be less than 10 ¦¸ and should be reliably grounded. The distance between grounding wires should be as short as possible, and wires with a diameter of ¡Ý 2.5mm2 should be selected for grounding wires.&lt;BR&gt;Connect the XB-CATV-BNC video signal lightning arrester in series with the video circuit according to the interface.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]XB-WX-G1760 Satellite antenna lightning arrester </title>
           <link>http://www.91way.com/info_en/23524.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:55</pubDate>
           <comments></comments>
           <description>Function and application scope:&lt;BR&gt;The XB-WX-G1760 coaxial satellite antenna lightning arrester is a coaxial lightning arrester specifically designed to protect satellite receivers. This product adopts a shielded shell packaging and is equipped with imported high-speed overvoltage protection devices, which have efficient defense functions against lightning high-voltage pulses induced on satellite antenna lines. A professionally designed ultra-low loss circuit ensures smooth and unobstructed information reception, taking into account the high-frequency characteristics of satellite reception.&lt;BR&gt;This lightning arrester is suitable for a frequency range of 450-1760MHz Z.&lt;BR&gt;This series of products is particularly suitable for the fine protection devices of satellite signal receiving systems in industries such as foreign-related hotels, government agencies, finance, securities, insurance, etc., effectively preventing software and hardware failures caused by equipment interference from lightning pulses.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;model&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;XB-WX-G1760&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;Nominal flow rate (8/20 ¦Ì s)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;5KA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;input impedance&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;50/75 ¦¸&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;Insertion wear and tear&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;1.5dB&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;response time&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;&amp;lt;1ns&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;Scope of application&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;satellite receiver&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;interface method&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;Metric/Imperial&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=345 align=center&gt;
&lt;P align=center&gt;frequency upper limit&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=344 align=center&gt;
&lt;P align=center&gt;1760MHz&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;Simply string the XB-WX-G1760 coaxial satellite antenna lightning arrester into the coaxial cable. The XB-WX-G1760 satellite antenna lightning arrester needs to be grounded.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]XB-SL-DATA Data dedicated line lightning arrester </title>
           <link>http://www.91way.com/info_en/23523.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:46</pubDate>
           <comments></comments>
           <description>Function and application scope:&lt;BR&gt;Suitable for rotary table and rotary cup electrostatic spraying, handheld and fixed electrostatic powder spraying, electrostatic scale removal, electrostatic flocking and other electrostatic new processes.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;100%&quot; border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;model&lt;/TD&gt;
&lt;TD width=345 align=center&gt;XB-SL-DATA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Nominal current capacity (8/20 ¦Ì s)&lt;/TD&gt;
&lt;TD width=345 align=center&gt;5KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;clamping voltage &lt;/TD&gt;
&lt;TD width=345 align=center&gt;24V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Insertion wear and tear&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;0.5dB&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;response time&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;1ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Insert resistor&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;2 ¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;interface method&lt;/TD&gt;
&lt;TD width=345 align=center&gt;terminal block&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;At the front end of the protected equipment's line, connect the XB-SL-DATA data dedicated line lightning arrester in series, with the input terminal (2-3) IN connected to the data transmission line and the output terminal (2-3) OUT connected to the protected equipment, and make a reliable electrical connection between the lightning arrester grounding terminal and the ground wire.&lt;BR&gt;If it is found that the installed lightning arrester cannot transmit data normally, remove the lightning arrester and directly connect it to the equipment. If it still cannot transmit normally, the lightning arrester is intact and other reasons should be investigated.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]RS232-25 Pin interface lightning arrester </title>
           <link>http://www.91way.com/info_en/23522.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:37</pubDate>
           <comments></comments>
           <description>Function and application scope:&lt;BR&gt;RS232 interface lightning arrester, with two types of 25 core or 9-core D-type standard connectors, can provide precise overvoltage protection for communication lines defined by standard or non-standard standards. Advanced American standard integrated overvoltage protection devices not only achieve efficient and reliable anti high voltage pulse impact function, but also make the lightning arrester look beautiful and elegant.&lt;BR&gt;This series of products is particularly suitable for computer systems in industries such as government agencies, finance, securities, and insurance as fine protection for corresponding interfaces, and can be used as anti surge protection devices for printer interfaces, effectively reducing software and hardware failures caused by pulse interference on equipment.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Model:&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;
&lt;P align=center&gt;XB-COM-D25/XB-COM-D15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P align=center&gt;XB-COM- D9&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Number of protection lines:&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;
&lt;P align=center&gt;25 15&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P align=center&gt;nine&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Clamp voltage (V):&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;
&lt;P align=center&gt;10V&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;27V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Flow capacity (8/20 ¦Ì S):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;5A&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Maximum data transmission rate (Mbit/s):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;&amp;gt;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Insertion loss (dB):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;&amp;lt;0.3&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Action time (ns):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;&amp;lt;1&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Interface method:&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;25 core, 15 core or 9-core D-type interface&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Scope of application:&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P align=center&gt;Computer serial/parallel port&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Usage:&lt;BR&gt;Simply string the 25 core, 15 core, or 9-core D-type standard connector RS232 interface lightning arrester into the data cable. The XB-COM-D9 RS232 interface lightning arrester needs to be grounded.&lt;BR&gt;Function and application scope:&lt;BR&gt;Suitable for rotary table and rotary cup electrostatic spraying, handheld and fixed electrostatic powder spraying, electrostatic scale removal, electrostatic flocking and other electrostatic new processes.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;model&lt;/TD&gt;
&lt;TD width=345 align=center&gt;XB-SL-DATA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Nominal current capacity (8/20 ¦Ì s)&lt;/TD&gt;
&lt;TD width=345 align=center&gt;5KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;clamping voltage &lt;/TD&gt;
&lt;TD width=345 align=center&gt;24V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Insertion wear and tear&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;0.5dB&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;response time&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;1ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;Insert resistor&lt;/TD&gt;
&lt;TD width=345 align=center&gt;&amp;lt;2 ¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=344 align=center&gt;interface method&lt;/TD&gt;
&lt;TD width=345 align=center&gt;terminal block&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;At the front end of the protected equipment's line, connect the XB-SL-DATA data dedicated line lightning arrester in series, with the input terminal (2-3) IN connected to the data transmission line and the output terminal (2-3) OUT connected to the protected equipment, and make a reliable electrical connection between the lightning arrester grounding terminal and the ground wire.&lt;BR&gt;If it is found that the installed lightning arrester cannot transmit data normally, remove the lightning arrester and directly connect it to the equipment. If it still cannot transmit normally, the lightning arrester is intact and other reasons should be investigated.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]XB-COM-RJ45/8 Network interface lightning arrester </title>
           <link>http://www.91way.com/info_en/23521.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:29</pubDate>
           <comments></comments>
           <description>The XB-COM-RJ45/8 network interface lightning arrester is produced using the latest imported semiconductor clamping devices from abroad, with a transmission rate of 100Mbit/s. It has the characteristics of fast action time, low output residual voltage, accurate clamping, low insertion loss, and good protection performance. It can effectively prevent communication equipment damage caused by overvoltage caused by ground potential rise or line induction in network systems.&lt;BR&gt;&lt;BR&gt;Technical parameters of XB-COM-RJ45/8 network interface lightning arrester:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;model&lt;/TD&gt;
&lt;TD width=343 align=center&gt;XB-COM-RJ45/8&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;Rated voltage Uc&lt;/TD&gt;
&lt;TD width=343 align=center&gt;6 V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=346 align=center&gt;Nominal discharge current Isn&lt;/TD&gt;
&lt;TD width=343 align=center&gt;1.5KA (line/line)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 align=center&gt;5KA (line/ground)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=2 width=346 align=center&gt;Voltage protection level Up at Isn&lt;/TD&gt;
&lt;TD width=343 align=center&gt;¡Ü 35 V (line/wire)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=343 align=center&gt;¡Ü 35 V (line/ground)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;Response time Ta&lt;/TD&gt;
&lt;TD width=343 align=center&gt;&amp;lt;1ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;Data transmission Vs&lt;/TD&gt;
&lt;TD width=343 align=center&gt;155Mbps&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;Number of protection lines&lt;/TD&gt;
&lt;TD width=343 align=center&gt;1~8&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=346 align=center&gt;interface method&lt;/TD&gt;
&lt;TD width=343 align=center&gt;RJ45&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Installation and maintenance methods:&lt;BR&gt;At the front end of the RJ45 interface of the computer network of the protected device, connect the lightning arrester in series, connect the &quot;IN&quot; end to the external line, connect the &quot;OUT&quot; end to the device, and make a reliable electrical connection between the grounding terminal of the lightning arrester and the ground wire.&lt;BR&gt;If it is found that the network interface with installed lightning arrester cannot transmit data normally, remove the lightning arrester and directly connect the RJ45 interface of the network cable to the equipment. If it still cannot transmit normally, the lightning arrester is intact and other reasons should be investigated.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]RS232-9 Pin interface lightning arrester </title>
           <link>http://www.91way.com/info_en/23520.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:20</pubDate>
           <comments></comments>
           <description>RS232 interface lightning arrester, with two types of 25 core or 9-core D-type standard connectors, can provide precise overvoltage protection for communication lines defined by standard or non-standard standards. Advanced American standard integrated overvoltage protection devices not only achieve efficient and reliable anti high voltage pulse impact function, but also make the lightning arrester look beautiful and elegant.&lt;BR&gt;This series of products is particularly suitable for computer systems in industries such as government agencies, finance, securities, and insurance as fine protection for corresponding interfaces, and can be used as anti surge protection devices for printer interfaces, effectively reducing software and hardware failures caused by pulse interference on equipment.&lt;BR&gt;&lt;BR&gt;Technical parameters of RS232-9 pin interface lightning arrester:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Model:&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;XB-COM-D25/XB-COM-D15&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;XB-COM- D9&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Number of protection lines:&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;25 15&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;nine&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Clamp voltage (V):&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;36%&quot; align=center&gt;10V&lt;/TD&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;27V&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Flow capacity (8/20 ¦Ì S):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;5A&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Maximum data transmission rate (Mbit/s):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;&amp;gt;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Insertion loss (dB):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;&amp;lt;0.3&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Action time (ns):&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;&amp;lt;1&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;32%&quot; align=center&gt;
&lt;P&gt;Interface method:&lt;/P&gt;&lt;/TD&gt;
&lt;TD colSpan=2 align=center&gt;25 core, 15 core or 9-core D-type interface&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Usage:&lt;BR&gt;Simply string the 25 core, 15 core, or 9-core D-type standard connector RS232 interface lightning arrester into the data cable. The XB-COM-D9 RS232 interface lightning arrester needs to be grounded.&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DBM-100 Lightning protection module </title>
           <link>http://www.91way.com/info_en/23519.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:11</pubDate>
           <comments></comments>
           <description>DBM-40¡¢ The 20 series lightning surge protector is suitable for AC 50/60Hz power supply systems such as TT, IT, TN, etc., to protect the power grid from lightning strikes or surge overvoltage.&lt;BR&gt;DBM-40¡¢ The 20 series lightning surge protector meets the requirements of IEC 61643-1 and GB18802.1 for Class II or III surge protectors.&lt;BR&gt;&lt;BR&gt;Model Description:&lt;BR&gt;&lt;BR&gt;&lt;A href=&quot;http://www.91way.com/upload2013/201307/20130710153738811.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 165px; WIDTH: 672px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DBM-100 Lightning Protection Module Model Description&quot; src=&quot;/upload2013/201307/20130710153738811.jpg&quot; width=672 height=165&gt;&lt;/A&gt;&lt;BR&gt;Product features:&lt;BR&gt;Equipped with overcurrent and overheat protection and a working status indicator window; Equipped with a remote fault alarm port.&lt;BR&gt;&lt;BR&gt;Technical Specifications:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;Model number&lt;/TD&gt;
&lt;TD width=314 align=center&gt;DBM-100&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Maximum continuous operating voltage Uc (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;385V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=140 align=center&gt;
&lt;P&gt;Protection&lt;BR&gt;grade&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=203 align=center&gt;IEC 61643-1¡¢GB18802.1&lt;/TD&gt;
&lt;TD width=314 align=center&gt;B&lt;BR&gt;Grade I&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Nominal discharge current In (8/20uS)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;
&lt;P&gt;60kA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Maximum discharge current Imax (8/20uS)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;
&lt;P&gt;100kA&lt;/P&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Voltage protection level Up&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;&amp;lt; 3KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Response time TA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;&amp;lt; 25 ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;caution function &lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;Window alarm remote signaling alarm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Cross sectional area of connecting wire&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;6-35 mm2 (single strand, multi strand wire)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;Install&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;35mm guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD colSpan=2 align=center&gt;
&lt;P&gt;temperature range&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;-40¡æ¡«+85¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=6 width=140 align=center&gt;Module N-PE&lt;/TD&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Maximum continuous operating voltage Uc (V)&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;250V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Insulation resistance Rins&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;&amp;gt;100 M¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Nominal discharge current In&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Maximum discharge current Imax&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;100kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Voltage protection level Up&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;&amp;lt; 1.5kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=203 align=center&gt;
&lt;P&gt;Response time TA&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=314 align=center&gt;&amp;lt;100 ns&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Application:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 95%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;95%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;serial number&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;model&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;polar number&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;purpose&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;protected mode&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;one&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;DBM-100/1+NPE-X&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;Full mode protection of single-phase power supply system&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;L-N N-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;
&lt;P&gt;DBM-100/2+0-X&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;two&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;Common mode protection of single-phase power supply system&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;L-PE N-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;three&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;
&lt;P&gt;DBM-100/3+0-X&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;three&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;Three phase power supply system&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;L1/L2/L3-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;four&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;
&lt;P&gt;DBM-100/4+0-X&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;four&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;Three phase power supply system&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;L1/L2/L3/N-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=&quot;6%&quot; align=center&gt;five&lt;/TD&gt;
&lt;TD width=&quot;27%&quot; align=center&gt;
&lt;P&gt;DBM-100/3+NPE-X&lt;/P&gt;&lt;/TD&gt;
&lt;TD width=&quot;15%&quot; align=center&gt;four&lt;/TD&gt;
&lt;TD width=&quot;29%&quot; align=center&gt;Three phase power supply system&lt;/TD&gt;
&lt;TD width=&quot;23%&quot; align=center&gt;L1/L2/L3-N N-PE&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]Y1.5W-0.8/3.9 type low-voltage lightning arrester </title>
           <link>http://www.91way.com/info_en/18827.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:42:02</pubDate>
           <comments></comments>
           <description>&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=3 width=&quot;98%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Places where lightning arresters are used&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Lightning arrester model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Rated voltage of lightning arrester kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;System nominal voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Continuous operating voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;DC (U1mA) reference voltage kV not less than&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Residual voltage under lightning impulse current KV (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2000 ¦Ô s square wave current A (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4/10 ¦Ô s impulse current kA (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Maximum leakage current ¦Ô A at 0.75 DC reference voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;low pressure&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Y1.5W-0.8/3.9&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point six six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point seven two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;one point eight zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;three point nine zero&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120410222244276.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 281px; WIDTH: 225px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of Y1.5W-0.8/3.9 Low Voltage Surge Arrester&quot; src=&quot;/upload2012/201204/20120410222244276.gif&quot; width=225 height=281&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Y1.5W-0.8/3.9 type low-voltage lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]Y1.5W-0.5/2.6 type low-voltage lightning arrester </title>
           <link>http://www.91way.com/info_en/18826.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:54</pubDate>
           <comments></comments>
           <description>Y1.5W-0.5/2.6 type low-voltage lightning arrester&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=3 width=&quot;98%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center width=&quot;None&quot;&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Places where lightning arresters are used&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Lightning arrester model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Rated voltage of lightning arrester kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;System nominal voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Continuous operating voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;DC (U1mA) reference voltage kV not less than&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Residual voltage under lightning impulse current KV (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2000 ¦Ô s square wave current A (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4/10 ¦Ô s impulse current kA (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Maximum leakage current ¦Ô A at 0.75 DC reference voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;low pressure&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;Y1.5W-0.5/2.6&lt;/TD&gt;
&lt;TD align=center&gt;zero point five zero&lt;/TD&gt;
&lt;TD align=center&gt;zero point three eight&lt;/TD&gt;
&lt;TD align=center&gt;zero point four two&lt;/TD&gt;
&lt;TD align=center&gt;one point two zero&lt;/TD&gt;
&lt;TD align=center&gt;two point six zero&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/upload2012/201204/20120410222031280.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 281px; WIDTH: 225px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of Y1.5W-0.5/2.6 Low Voltage Surge Arrester&quot; src=&quot;/upload2012/201204/20120410222031280.gif&quot; width=225 height=281&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Y1.5W-0.5/2.6 type low-voltage lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]HY3WL1-2.2KV series composite jacket zinc oxide DC lightning arrester </title>
           <link>http://www.91way.com/info_en/18825.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:45</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;HEIGHT: 70px; WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; height=70 cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD width=132&gt;Lightning arrester model&lt;/TD&gt;
&lt;TD width=89&gt;Rated voltage of lightning arrester (kV)&lt;/TD&gt;
&lt;TD width=66&gt;System nominal voltage kV&lt;/TD&gt;
&lt;TD width=75&gt;Direct discharge voltage KV&lt;/TD&gt;
&lt;TD width=69&gt;Impulse discharge voltage KV&lt;/TD&gt;
&lt;TD width=89&gt;8/20WS impact residual voltage not exceeding KV&lt;/TD&gt;
&lt;TD width=76&gt;Leakage current not exceeding KV&lt;/TD&gt;
&lt;TD width=78&gt;Rectified voltage KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;HY3WL1-2.2/5.4&lt;/TD&gt;
&lt;TD&gt;two point two&lt;/TD&gt;
&lt;TD&gt;one point six five&lt;/TD&gt;
&lt;TD&gt;3.4-4.5&lt;/TD&gt;
&lt;TD&gt;five point four&lt;/TD&gt;
&lt;TD&gt;five point four&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HY3WL1-2.2KV series composite jacket zinc oxide DC lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]HY3WL1-1.1KV series composite jacket zinc oxide DC lightning arrester </title>
           <link>http://www.91way.com/info_en/18824.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:37</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center width=&quot;None&quot;&gt;
&lt;TD width=132&gt;Lightning arrester model&lt;/TD&gt;
&lt;TD width=89&gt;Rated voltage of lightning arrester (kV)&lt;/TD&gt;
&lt;TD width=66&gt;System nominal voltage kV&lt;/TD&gt;
&lt;TD width=75&gt;Direct discharge voltage KV&lt;/TD&gt;
&lt;TD width=69&gt;Impulse discharge voltage KV&lt;/TD&gt;
&lt;TD width=89&gt;8/20WS impact residual voltage not exceeding KV&lt;/TD&gt;
&lt;TD width=76&gt;Leakage current not exceeding KV&lt;/TD&gt;
&lt;TD width=78&gt;Rectified voltage KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;HY3WL1-1.1/2.9&lt;/TD&gt;
&lt;TD&gt;one point one&lt;/TD&gt;
&lt;TD&gt;zero point eight two five&lt;/TD&gt;
&lt;TD&gt;1.7-2.2&lt;/TD&gt;
&lt;TD&gt;two point nine&lt;/TD&gt;
&lt;TD&gt;two point nine&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HY3WL1-1.1KV series composite jacket zinc oxide DC lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]FS-0.38  Valve type lightning arrester </title>
           <link>http://www.91way.com/info_en/15358.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:28</pubDate>
           <comments></comments>
           <description>Service conditions for FS-0.38 valve type lightning arrester&lt;BR&gt;&lt;BR&gt;The ambient temperature is &#177; 40 ¡æ&lt;BR&gt;The altitude above sea level shall not exceed 1000m&lt;BR&gt;Power system frequency 50Hz or 60Hz&lt;BR&gt;The maximum wind speed at the installation location is 35m/s&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Specification and model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage of the system kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage of lightning arrester kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Power frequency discharge voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;1.2/50 ¦Ì S impulse discharge voltage kV (peak value) not exceeding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Wavefront impulse discharge voltage kV (peak)&lt;BR&gt;not greater than&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Residual voltage of 5kAkV (peak value) under nominal current of 8/20 ¦Ì S shall not exceed&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Overall dimensions mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FS-0.38&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point three eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point five zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1.10~1.60&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three point nine zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ninety-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;FS-0.38 valve type lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]FS-0.22 Valve type lightning arrester </title>
           <link>http://www.91way.com/info_en/15357.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:20</pubDate>
           <comments></comments>
           <description>Service conditions for FS-0.22 valve type lightning arrester for distribution&lt;BR&gt;&lt;BR&gt;The ambient temperature is &#177; 40 ¡æ&lt;BR&gt;Sea level not exceeding 1000m&lt;BR&gt;Power system frequency 50Hz or 60Hz&lt;BR&gt;The maximum wind speed at the installation location is 35m/s&lt;BR&gt;&lt;BR&gt;Main technical parameters&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Specification and model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage of the system kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Rated voltage of lightning arrester kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Power frequency discharge voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;1.2/50 ¦Ì S impulse discharge voltage kV (peak value) not exceeding&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Wavefront impulse discharge voltage kV (peak)&lt;BR&gt;not greater than&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=2&gt;
&lt;DIV align=center&gt;Residual voltage of 5kAkV (peak value) under nominal current of 8/20 ¦Ì S shall not exceed&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;Overall dimensions mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;H&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;D&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;FS-0.22&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;zero point two five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;0.50~0.90&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one point seven zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two point two one&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one point five zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;one hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;FS-0.22 Valve type lightning arrester for distribution&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]0.22-0.5KV Zinc oxide lightning arrester </title>
           <link>http://www.91way.com/info_en/14714.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:11</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Place of use&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=3&gt;
&lt;DIV align=center&gt;Low voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Product model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;HY1.5W-0.28/1.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV&gt;HY1.5W-0.5/2.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;HY1.5W-0.8/3.9&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of rated voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of nominal voltage of the system (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point three eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point six six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of continuous operating voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point four two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point seven two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;DC (U1mA) reference voltage not less than (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;one point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;one point eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=103&gt;
&lt;DIV align=center&gt;Maximum residual voltage peak value (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under steep wave impulse current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under lightning impulse current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;one point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;two point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;three point nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under the impact current of operation&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;2000 ¦Ì s square wave current capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;4/10 ¦Ì s peak impulse current (kA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Maximum leakage current under 0.75 DC reference voltage (¦Ì A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;0.22-0.5kV zinc oxide lightning arrester&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]MSK type feeder surge protector </title>
           <link>http://www.91way.com/info_en/4610.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:41:02</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200901/200911383942817.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 399px; WIDTH: 427px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of MSK type feeder surge protector&quot; src=&quot;/uploadfiles/200901/200911383942817.jpg&quot; width=427 height=399&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;MSK-¦Ë/4-N2&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911384010682.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 406px; WIDTH: 441px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 2 of MSK type feeder surge protector&quot; src=&quot;/uploadfiles/200901/200911384010682.jpg&quot; width=441 height=406&gt;&lt;/A&gt;&lt;BR&gt;MSK-E-N2&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911384036764.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 416px; WIDTH: 475px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 3 of MSK type feeder surge protector&quot; src=&quot;/uploadfiles/200901/200911384036764.jpg&quot; width=475 height=416&gt;&lt;/A&gt;&lt;BR&gt;MSK-G-BNC1&amp;nbsp;&lt;BR&gt;&lt;BR&gt;Technical specifications - ¦Ë/4 series&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=99&gt;model&lt;/TD&gt;
&lt;TD width=101&gt;MSK-¦Ë/4-N1&lt;/TD&gt;
&lt;TD width=103&gt;MSK-¦Ë/4-N2&lt;/TD&gt;
&lt;TD width=103&gt;MSK-¦Ë/4-N3&lt;/TD&gt;
&lt;TD width=98&gt;MSK-¦Ë/4-N4&lt;/TD&gt;
&lt;TD width=90&gt;MSK-¦Ë/4-N5&lt;/TD&gt;
&lt;TD width=97&gt;MSK-¦Ë/4-N6&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Interface type&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;characteristic impedance&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;frequency range&lt;/TD&gt;
&lt;TD&gt;130~470MHz&lt;/TD&gt;
&lt;TD&gt;800~960MHz&lt;/TD&gt;
&lt;TD&gt;1700~2400MHz&lt;/TD&gt;
&lt;TD&gt;800~2500MHz&lt;/TD&gt;
&lt;TD&gt;3350~3600MHz&lt;/TD&gt;
&lt;TD&gt;5000~6000MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Applicable power&lt;/TD&gt;
&lt;TD&gt;300W&lt;/TD&gt;
&lt;TD&gt;300W&lt;/TD&gt;
&lt;TD&gt;150W&lt;/TD&gt;
&lt;TD&gt;300W&lt;/TD&gt;
&lt;TD&gt;150W&lt;/TD&gt;
&lt;TD&gt;25W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Standing wave coefficient&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;P&gt;Nominal discharge current&lt;/P&gt;&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23&gt;Limit voltage&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22&gt;purpose&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;GSM base station&lt;/TD&gt;
&lt;TD&gt;GSM base station&lt;/TD&gt;
&lt;TD&gt;3G system and radio&lt;/TD&gt;
&lt;TD&gt;Microwave communication station&lt;/TD&gt;
&lt;TD&gt;Wireless communication station&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=99&gt;model&lt;/TD&gt;
&lt;TD width=161&gt;MSK-1/4-DIN7/16&lt;/TD&gt;
&lt;TD width=143&gt;MSK-1/4-DIN/N2&lt;/TD&gt;
&lt;TD width=162&gt;MSK-1/4-DIN/1N3&lt;/TD&gt;
&lt;TD width=130&gt;MSK-1/4-N7&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Interface type&lt;/TD&gt;
&lt;TD&gt;DIN7/16£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;DIN/N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;DIN/N£¨K/J£©&lt;/TD&gt;
&lt;TD width=130&gt;N£¨K/J&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;characteristic impedance&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD width=130&gt;50¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;frequency range&lt;/TD&gt;
&lt;TD&gt;800~1000£» 1600~2500MHz&lt;/TD&gt;
&lt;TD&gt;800~960MHz&lt;/TD&gt;
&lt;TD&gt;800~960MHz&lt;/TD&gt;
&lt;TD width=130&gt;800~960MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power consumption&lt;/TD&gt;
&lt;TD&gt;500W&lt;/TD&gt;
&lt;TD&gt;500W&lt;/TD&gt;
&lt;TD&gt;500W&lt;/TD&gt;
&lt;TD width=130&gt;20W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Standing wave coefficient&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD width=130&gt;¡Ü1.15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;¡Ü0.15db&lt;/TD&gt;
&lt;TD&gt;¡Ü0.15db&lt;/TD&gt;
&lt;TD&gt;¡Ü0.15db&lt;/TD&gt;
&lt;TD width=130&gt;¡Ü0.15db&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current&lt;/TD&gt;
&lt;TD&gt;40kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD width=130&gt;20kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current&lt;/TD&gt;
&lt;TD&gt;60kA&lt;/TD&gt;
&lt;TD&gt;60kA&lt;/TD&gt;
&lt;TD&gt;60kA&lt;/TD&gt;
&lt;TD width=130&gt;60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23&gt;Limit voltage&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD width=130&gt;¡Ü100V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=22&gt;purpose&lt;/TD&gt;
&lt;TD&gt;High power, broadband communication equipment&lt;/TD&gt;
&lt;TD&gt;GSM base station&lt;/TD&gt;
&lt;TD&gt;3G base station&lt;/TD&gt;
&lt;TD width=130&gt;Wireless transceiver equipment&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Technical specifications - Microstrip series&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=99&gt;model&lt;/TD&gt;
&lt;TD width=101&gt;MSK-E-N1&lt;/TD&gt;
&lt;TD width=103&gt;MSK-E-N2&lt;/TD&gt;
&lt;TD width=103&gt;MSK-E-N3&lt;/TD&gt;
&lt;TD width=98&gt;MSK-E-N4&lt;/TD&gt;
&lt;TD width=90&gt;MSK-E-N5&lt;/TD&gt;
&lt;TD width=97&gt;MSK-E-N6&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Interface type&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;characteristic impedance&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;frequency range&lt;/TD&gt;
&lt;TD&gt;100~500MHz&lt;/TD&gt;
&lt;TD&gt;100~500MHz&lt;/TD&gt;
&lt;TD&gt;100~500MHz&lt;/TD&gt;
&lt;TD&gt;100~500MHz&lt;/TD&gt;
&lt;TD&gt;1500~2000MHz&lt;/TD&gt;
&lt;TD&gt;1500~2000MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power consumption&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Standing wave coefficient&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;&amp;amp;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23&gt;Limit voltage&lt;/TD&gt;
&lt;TD&gt;¡Ü190V&lt;/TD&gt;
&lt;TD&gt;¡Ü190V&lt;/TD&gt;
&lt;TD&gt;¡Ü100V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;purpose&lt;/TD&gt;
&lt;TD&gt;Communication equipment&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;GSM base station&lt;/TD&gt;
&lt;TD&gt;PHS base station&lt;/TD&gt;
&lt;TD&gt;W. TD base station wireless LAN&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=99&gt;model&lt;/TD&gt;
&lt;TD width=101&gt;MSK-E-L16N&lt;/TD&gt;
&lt;TD width=103&gt;MSK-E-TNE&lt;/TD&gt;
&lt;TD width=103&gt;MSK-E-DIN7/164&lt;/TD&gt;
&lt;TD width=98&gt;MSK-1E-N8&lt;/TD&gt;
&lt;TD width=90&gt;MSK-E-N7&lt;/TD&gt;
&lt;TD width=97&gt;MSK-E-N11&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Interface type&lt;/TD&gt;
&lt;TD&gt;L16N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;TNC£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;L16N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;characteristic impedance&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;frequency range&lt;/TD&gt;
&lt;TD&gt;3~30MHz&lt;/TD&gt;
&lt;TD&gt;3~30MHz&lt;/TD&gt;
&lt;TD&gt;700~1000MHz&lt;/TD&gt;
&lt;TD&gt;800~1000MHz&lt;/TD&gt;
&lt;TD&gt;700~1000MHz&lt;/TD&gt;
&lt;TD&gt;800~1000MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power consumption&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;60W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;300W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;300W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Standing wave coefficient&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD&gt;¡Ü1.15&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.2dB&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=23&gt;Limit voltage&lt;/TD&gt;
&lt;TD&gt;¡Ü300V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26&gt;DC power supply&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;12V&lt;/TD&gt;
&lt;TD&gt;5V&lt;/TD&gt;
&lt;TD&gt;12V&amp;nbsp;&lt;/TD&gt;
&lt;TD&gt;5V&amp;nbsp;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;purpose&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;PHS base station&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;Communication equipment, 3G base station&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;Communication equipment, 3G base station&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Technical Specifications - Coaxial Series&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD height=25 width=98&gt;model&lt;/TD&gt;
&lt;TD width=81&gt;MSK-TNC3&lt;/TD&gt;
&lt;TD width=88&gt;MSK-G-BNC1&lt;/TD&gt;
&lt;TD width=84&gt;MSK-G-N2&lt;/TD&gt;
&lt;TD width=96&gt;MSK-G-DIN7/16&lt;/TD&gt;
&lt;TD width=90&gt;MSK-G-F1&lt;/TD&gt;
&lt;TD width=80&gt;MSK-G-F2&lt;/TD&gt;
&lt;TD width=72&gt;MSK-G-FL10&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Interface type&lt;/TD&gt;
&lt;TD&gt;TNC£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;BNC£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;N£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;DIN7/16£¨K/J£©&lt;/TD&gt;
&lt;TD&gt;F (K/J) 3/8 &quot;thread&lt;/TD&gt;
&lt;TD&gt;F (K/J) 3/8 &quot;thread&lt;/TD&gt;
&lt;TD&gt;FL10£¨K/J£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;characteristic impedance&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;50¦¸&lt;/TD&gt;
&lt;TD&gt;75¦¸&lt;/TD&gt;
&lt;TD&gt;75¦¸&lt;/TD&gt;
&lt;TD&gt;75¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;frequency range&lt;/TD&gt;
&lt;TD&gt;DC~2500MHz&lt;/TD&gt;
&lt;TD&gt;DC~2500MHz&lt;/TD&gt;
&lt;TD&gt;DC~2500MHz&lt;/TD&gt;
&lt;TD&gt;DC~2500MHz&lt;/TD&gt;
&lt;TD&gt;DC~2500MHz&lt;/TD&gt;
&lt;TD&gt;DC~1500MHz&lt;/TD&gt;
&lt;TD&gt;DC~1500MHz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;power consumption&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;
&lt;TD&gt;100W&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Standing wave coefficient&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü1.5&lt;/TD&gt;
&lt;TD&gt;¡Ü1.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;¡Ü0.3dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.3dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.3dB&lt;/TD&gt;
&lt;TD&gt;¡Ü0.3dB&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2&lt;/TD&gt;
&lt;TD&gt;¡Ü2.0&lt;/TD&gt;
&lt;TD&gt;¡Ü1.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24&gt;Maximum discharge current&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26&gt;Limit voltage&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;
&lt;TD&gt;¡Ü700V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=26&gt;DC power supply&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;230V&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;230V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=25&gt;purpose&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;communication equipment&lt;/TD&gt;
&lt;TD&gt;Satellite TV Ground Station Cable TV&lt;/TD&gt;
&lt;TD&gt;Satellite TV Ground Station Cable TV&lt;/TD&gt;
&lt;TD&gt;Satellite TV Ground Station Cable TV&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;MSK type feeder surge protector&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]MSS type signal/power combination surge protector </title>
           <link>http://www.91way.com/info_en/4609.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:53</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;MSS type signal/power combination surge protector&lt;BR&gt;&lt;BR&gt;Monitoring system three in one or two in one SPD&lt;BR&gt;Multi functional overvoltage protection&lt;BR&gt;Large current capacity, fast response time, and high protection level&lt;BR&gt;Low insertion loss and superior signal transmission performance&lt;BR&gt;Small size, easy installation, and convenient maintenance&lt;BR&gt;Can protect the power, video, and control circuits of the video surveillance system&lt;BR&gt;&lt;BR&gt;Technical specifications of signal/power combination SPD MSC-31/21&lt;/P&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200901/200911382554356.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 544px; WIDTH: 540px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing of MSS type signal/power combination surge protector&quot; src=&quot;/uploadfiles/200901/200911382554356.jpg&quot; width=540 height=544&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911382621865.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 242px; WIDTH: 630px; FILTER: none&quot; border=0 hspace=0 alt=&quot;External dimensions of MSS type signal/power combination surge protector&quot; src=&quot;/uploadfiles/200901/200911382621865.jpg&quot; width=630 height=242&gt;&lt;/A&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=167&gt;Product model&lt;/TD&gt;
&lt;TD width=199&gt;TYPE&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum continuous operating voltage&lt;/TD&gt;
&lt;TD&gt;Uc&lt;/TD&gt;
&lt;TD&gt;385V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current (8/20)&lt;/TD&gt;
&lt;TD&gt;In&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current (8/20)&lt;/TD&gt;
&lt;TD align=center&gt;Imax&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Voltage protection level (In)&lt;/TD&gt;
&lt;TD&gt;Up&lt;/TD&gt;
&lt;TD&gt;¡Ü1200V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Control and protect parameters&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum continuous operating voltage&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;24V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current (8/20)&lt;/TD&gt;
&lt;TD&gt;In&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD height=24 align=center&gt;Maximum discharge current (8/20)&lt;/TD&gt;
&lt;TD&gt;Imax&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Voltage protection level (In)&lt;/TD&gt;
&lt;TD&gt;Up&lt;/TD&gt;
&lt;TD&gt;¡Ü40V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;transmission rate&lt;/TD&gt;
&lt;TD&gt;Vs&lt;/TD&gt;
&lt;TD&gt;2MBit/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Video protection parameters&lt;/TD&gt;
&lt;TD align=center&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum continuous operating voltage&lt;/TD&gt;
&lt;TD align=center&gt;&lt;/TD&gt;
&lt;TD&gt;8V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current (8/20)&lt;/TD&gt;
&lt;TD&gt;In&lt;/TD&gt;
&lt;TD&gt;5kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum discharge current (8/20)&lt;/TD&gt;
&lt;TD&gt;Imax&lt;/TD&gt;
&lt;TD&gt;10kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Voltage protection level (In)&lt;/TD&gt;
&lt;TD&gt;Up&lt;/TD&gt;
&lt;TD&gt;¡Ü20V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;transmission rate&lt;/TD&gt;
&lt;TD&gt;Vs&lt;/TD&gt;
&lt;TD&gt;20MBit/s&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;insertion loss&lt;/TD&gt;
&lt;TD&gt;aE&lt;/TD&gt;
&lt;TD&gt;¡Ü0.5dB&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;MSS type signal/power combination surge protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]MSS Signal Surge Protector </title>
           <link>http://www.91way.com/info_en/4608.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:44</pubDate>
           <comments></comments>
           <description>&lt;P align=left&gt;MSS-RJ45 series&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911382912245.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 168px; WIDTH: 238px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 1 of MSS signal surge protector&quot; src=&quot;/uploadfiles/200901/200911382912245.jpg&quot; width=238 height=168&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200901/200911382927735.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 162px; WIDTH: 271px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Wiring Diagram 1&quot; src=&quot;/uploadfiles/200901/200911382927735.jpg&quot; width=271 height=162&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;The network signal lightning arrester connected by RJ45 has a large current capacity, fast response time, high protection level, low loss, and superior signal transmission performance, which can protect the lines of various computer network devices&lt;/P&gt;
&lt;P align=center&gt;MSS-BNC series&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911383035870.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 137px; WIDTH: 282px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Outline Drawing 2&quot; src=&quot;/uploadfiles/200901/200911383035870.jpg&quot; width=282 height=137&gt;&lt;/A&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911383113877.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 170px; WIDTH: 373px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Wiring Diagram 2&quot; src=&quot;/uploadfiles/200901/200911383113877.jpg&quot; width=373 height=170&gt;&lt;/A&gt;&lt;/P&gt;
&lt;P align=left&gt;The video signal SPD with coaxial connection has a large current capacity, wide operating frequency band, low insertion loss, fast response time, high protection level, and superior signal transmission performance&lt;BR&gt;Can protect the lines of single port cable TV, video surveillance and other systems&lt;BR&gt;&lt;BR&gt;MSS-J series&lt;/P&gt;
&lt;P align=left&gt;&lt;A href=&quot;/uploadfiles/200901/20091138333266.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 143px; WIDTH: 240px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Outline drawing 3 of MSS signal surge protector&quot; src=&quot;/uploadfiles/200901/20091138333266.jpg&quot; width=240 height=143&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200901/200911383333997.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 164px; WIDTH: 319px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Wiring Diagram 3&quot; src=&quot;/uploadfiles/200901/200911383333997.jpg&quot; width=319 height=164&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;The SPD hot swappable separation structure of twisted pair signal using terminal connection method consists of a base and a pluggable protection module, with large current capacity, fast response time, and high protection level&lt;BR&gt;Low loss, superior signal transmission performance, multi-level voltage protection, 35mm DIN rail installation suitable for various signal lines&lt;BR&gt;&lt;BR&gt;MSS-RJ11 series&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200901/200911383433767.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 139px; WIDTH: 175px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Outline Drawing 4&quot; src=&quot;/uploadfiles/200901/200911383433767.jpg&quot; width=175 height=139&gt;&lt;/A&gt;&lt;A href=&quot;/uploadfiles/200901/200911383452175.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 163px; WIDTH: 307px; FILTER: none&quot; border=0 hspace=0 alt=&quot;MSS Signal Surge Protector Wiring Diagram 4&quot; src=&quot;/uploadfiles/200901/200911383452175.jpg&quot; width=307 height=163&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;The twisted pair signal SPD connected by RJ11 has a large current capacity, fast response time, high protection level, low loss, and superior signal transmission performance, providing full protection for 2/4 wires&lt;BR&gt;Multi level voltage protection circuit design can protect TEL, ADSL, ISDN, DDN and other lines&lt;BR&gt;&lt;BR&gt;Signal SPD technical specifications&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P align=left&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=167&gt;Product model&lt;/TD&gt;
&lt;TD width=115&gt;MSS-RJ11&lt;/TD&gt;
&lt;TD width=106&gt;MSS-RJ45-5&lt;/TD&gt;
&lt;TD width=112&gt;MSS-J-24/12&lt;/TD&gt;
&lt;TD width=99&gt;MSS-BNC-5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Working voltage (V)&lt;/TD&gt;
&lt;TD&gt;one hundred and ten&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;24/12&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;connection type&lt;/TD&gt;
&lt;TD&gt;RJ11&lt;/TD&gt;
&lt;TD&gt;RJ45&lt;/TD&gt;
&lt;TD&gt;A pair of wire connection terminals&lt;/TD&gt;
&lt;TD&gt;BNC&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Characteristic impedance (¦¸)&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Transmission rate (bit/s)&lt;/TD&gt;
&lt;TD&gt;2M&lt;/TD&gt;
&lt;TD&gt;100M&lt;/TD&gt;
&lt;TD&gt;2M&lt;/TD&gt;
&lt;TD&gt;100M&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Insertion loss (dB)&lt;/TD&gt;
&lt;TD&gt;¡Ü0.5&lt;/TD&gt;
&lt;TD&gt;¡Ü0.1&lt;/TD&gt;
&lt;TD&gt;¡Ü0.3&lt;/TD&gt;
&lt;TD&gt;¡Ü0.5&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current (8/20 ¦Ì s) (kA)&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;SE-PE£º5 L-PE£º3&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;five&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Limiting voltage (10/700 ¦Ì s) (V)&lt;/TD&gt;
&lt;TD&gt;¡Ü300&lt;/TD&gt;
&lt;TD&gt;¡Ü30&lt;/TD&gt;
&lt;TD&gt;¡Ü60/¡Ü40&lt;/TD&gt;
&lt;TD&gt;¡Ü30&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Quality (g)&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;ninety-five&lt;/TD&gt;
&lt;TD&gt;seventy&lt;/TD&gt;
&lt;TD&gt;seventy-five&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;MSS signal surge protector&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DBM-80 series lightning protection module </title>
           <link>http://www.91way.com/info_en/4569.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:35</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application:&lt;BR&gt;The DBM-80 series lightning surge protector is suitable for AC 50/60Hz power supply systems such as TT, IT, TN, etc., to protect the power grid from lightning strikes or surge overvoltage.&lt;BR&gt;The DBM-80 series lightning surge protector meets the requirements of IEC61643-1 and GB18802.1 for I-pole surge protectors.&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD height=19 width=&quot;27%&quot;&gt;model&lt;/TD&gt;
&lt;TD width=&quot;62%&quot;&gt;DBM-60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Maximum continuous operating voltage Uc (V)&lt;/TD&gt;
&lt;TD&gt;275 385 440&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;DIV VDE 0675&lt;BR&gt;protection level&lt;BR&gt;IEC 61643-1¡¢GB 18802.1&lt;/TD&gt;
&lt;TD&gt;B&lt;BR&gt;&lt;BR&gt;Level I&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Nominal discharge current In (8/20)&lt;/TD&gt;
&lt;TD&gt;40KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Maximum discharge current Imax (8/20)&lt;/TD&gt;
&lt;TD&gt;80KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Impulse current (10/350) Iimp&lt;/TD&gt;
&lt;TD&gt;25KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Voltage protection level Up&lt;/TD&gt;
&lt;TD&gt;2.5KV 2.5KV 3.0KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Response time TA&lt;/TD&gt;
&lt;TD&gt;©‚25ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;caution function &lt;/TD&gt;
&lt;TD&gt;Window alarm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Cross sectional area of connecting wire&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35mm2 (single strand, multi strand wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Install&lt;/TD&gt;
&lt;TD&gt;35mm guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;temperature range&lt;/TD&gt;
&lt;TD&gt;-40¡æ~ +85¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;IP rating&lt;/TD&gt;
&lt;TD&gt;IP20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;External dimensions (single pole)&lt;/TD&gt;
&lt;TD&gt;90mm&#215;27mm&#215;62mm&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD height=19 width=&quot;7%&quot;&gt;serial number&lt;/TD&gt;
&lt;TD width=&quot;45%&quot;&gt;model&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;polar number&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;purpose&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;one&lt;/TD&gt;
&lt;TD&gt;DBM-80/275-2&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TN single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;two&lt;/TD&gt;
&lt;TD&gt;DBM-80/275-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;three&lt;/TD&gt;
&lt;TD&gt;DBM-80/275-4&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;four&lt;/TD&gt;
&lt;TD&gt;DBM-80/385-2&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TT single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;five&lt;/TD&gt;
&lt;TD&gt;DBM-80/385-4&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TT three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;six&lt;/TD&gt;
&lt;TD&gt;DBM-80/440-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;IT three-phase system&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DBM-80 series lightning protection module&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DBM-60 series lightning protection module </title>
           <link>http://www.91way.com/info_en/4568.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:26</pubDate>
           <comments></comments>
           <description>&lt;P&gt;The DBM-60 series lightning surge protector is suitable for AC 50/60Hz power supply systems such as TT, IT, TN, etc., to protect the power grid from lightning strikes or surge overvoltage. &amp;nbsp;&lt;BR&gt;The DBM-60 series lightning surge protector meets the requirements of IEC 61643-1 and GB 18802.1 for II pole surge protectors.&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;model&lt;/TD&gt;
&lt;TD&gt;DBM-60&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Maximum continuous operating voltage Uc (V)&lt;/TD&gt;
&lt;TD&gt;275 385 440&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;DIV VDE 0675&lt;BR&gt;protection level&lt;BR&gt;IEC 61643-1¡¢GB 18802.1&lt;/TD&gt;
&lt;TD&gt;C&lt;BR&gt;Level II&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Nominal discharge current In (8/20)&lt;/TD&gt;
&lt;TD&gt;30KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Maximum discharge current Imax (8/20)&lt;/TD&gt;
&lt;TD&gt;60KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Voltage protection level Up&lt;/TD&gt;
&lt;TD&gt;2.0KV 2.0KV 2.5KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Response time TA&lt;/TD&gt;
&lt;TD&gt;©‚25ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;caution function &lt;/TD&gt;
&lt;TD&gt;Window alarm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Cross sectional area of connecting wire&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;6-35mm2 (single strand, multi strand wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Install&lt;/TD&gt;
&lt;TD&gt;35mm guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;temperature range&lt;/TD&gt;
&lt;TD&gt;-40¡æ~ +85¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;IP rating&lt;/TD&gt;
&lt;TD&gt;IP20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;External dimensions (single pole)&lt;/TD&gt;
&lt;TD&gt;90mm&#215;18mm&#215;62mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=6 width=&quot;11%&quot;&gt;module&lt;BR&gt;N-PE&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;Nominal voltage Un&lt;/TD&gt;
&lt;TD&gt;255V/50-60Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Insulation resistance Rins&lt;/TD&gt;
&lt;TD&gt;&amp;gt;100M¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Nominal discharge current In&lt;/TD&gt;
&lt;TD&gt;30KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Maximum discharge current Imax&lt;/TD&gt;
&lt;TD&gt;60KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Voltage protection level Up&lt;/TD&gt;
&lt;TD&gt;2.0KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Response time TA&lt;/TD&gt;
&lt;TD&gt;&amp;lt;100ns&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;7%&quot;&gt;serial number&lt;/TD&gt;
&lt;TD width=&quot;45%&quot;&gt;model&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;polar number&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;purpose&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;DBM-60/275-2&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TN single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;DBM-60/275-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;DBM-60/275-4&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;DBM-60/385-2¡¢DBM-60/275-1N&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TT single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;DBM-60/385-4¡¢DBM-60/275-3N&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TT three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;DBM-60/440-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;IT three-phase system&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;DBM-60 series lightning protection module&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DBM40,DBM20 series lightning protection module </title>
           <link>http://www.91way.com/info_en/4567.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:17</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Scope of application:&lt;BR&gt;The DBM-40 and DBM-20 series lightning surge protectors are suitable for AC 50/60Hz power supply systems such as TT, IT, TN, etc., to protect the power grid from lightning strikes or surge overvoltage.&lt;BR&gt;DBM-40 and DBM-20 series lightning surge protectors meet the requirements of IEC 61643-1 and GB18802.1 for II pole surge protectors&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;model&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;DBM-40&lt;/TD&gt;
&lt;TD width=&quot;32%&quot;&gt;DBM-20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Maximum continuous operating voltage Uc (V)&lt;/TD&gt;
&lt;TD&gt;275 385 440&lt;/TD&gt;
&lt;TD&gt;275 385 440&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;DIV VDE 0675&lt;BR&gt;protection level&lt;BR&gt;IEC 61643-1¡¢GB 18802.1&lt;BR&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;D&lt;BR&gt;&lt;BR&gt;Level II&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Nominal discharge current In (8/20)&lt;/TD&gt;
&lt;TD&gt;20KVA&lt;/TD&gt;
&lt;TD&gt;10KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Maximum discharge current Imax (8/20)&lt;/TD&gt;
&lt;TD&gt;40KVA&lt;/TD&gt;
&lt;TD&gt;20KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Voltage protection level Up&lt;/TD&gt;
&lt;TD&gt;1.5KV 1.8KV 2.0KV&lt;/TD&gt;
&lt;TD&gt;1.2KV 1.2KV 1.5KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Response time TA&lt;/TD&gt;
&lt;TD colSpan=2&gt;¡´25ns&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;caution function &lt;/TD&gt;
&lt;TD colSpan=2&gt;Visual alert&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Cross sectional area of connecting wire&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;6-35mm2 (single strand, multi strand wire)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Install&lt;/TD&gt;
&lt;TD colSpan=2&gt;35mm guide rail&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;temperature range&lt;/TD&gt;
&lt;TD colSpan=2&gt;-40¡æ~ +85¡æ&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;IP rating&lt;/TD&gt;
&lt;TD colSpan=2&gt;IP20&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;External dimensions (single pole)&lt;/TD&gt;
&lt;TD colSpan=2&gt;90mm&#215;18mm&#215;62mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=6 width=&quot;11%&quot;&gt;module&lt;BR&gt;N-PE&lt;/TD&gt;
&lt;TD width=&quot;24%&quot;&gt;Nominal voltage Un&lt;/TD&gt;
&lt;TD colSpan=2&gt;255V/50-60Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Insulation resistance Rins&lt;/TD&gt;
&lt;TD colSpan=2&gt;&amp;gt;100M¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Nominal discharge current In&lt;/TD&gt;
&lt;TD colSpan=2&gt;20KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Maximum discharge current Imax&lt;/TD&gt;
&lt;TD colSpan=2&gt;40KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Voltage protection level Up&lt;/TD&gt;
&lt;TD colSpan=2&gt;1.5KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Response time TA&lt;/TD&gt;
&lt;TD colSpan=2&gt;&amp;lt;100ns&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;7%&quot;&gt;serial number&lt;/TD&gt;
&lt;TD width=&quot;45%&quot;&gt;model&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;polar number&lt;/TD&gt;
&lt;TD width=&quot;34%&quot;&gt;purpose&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;one&lt;/TD&gt;
&lt;TD&gt;DBM-40/275-2¡¢DBM-20/275-2&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TN single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;DBM-40/275-3¡¢DBM-20/275-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;DBM-40/275-4¡¢DBM-20/275-4&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TN-C, TN-C-S three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;DBM-40/385-2¡¢DBM-20/385-2&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;
&lt;TD&gt;TT single-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;five&lt;/TD&gt;
&lt;TD&gt;DBM-40/385-4¡¢DBM-20/385-4&lt;BR&gt;DBM-40/275-3N¡¢DBM-20/275-3N&lt;/TD&gt;
&lt;TD&gt;four&lt;/TD&gt;
&lt;TD&gt;TT three-phase system&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;six&lt;/TD&gt;
&lt;TD&gt;DBM-40/440-3¡¢DBM-20/440-3&lt;/TD&gt;
&lt;TD&gt;three&lt;/TD&gt;
&lt;TD&gt;IT three-phase system&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DB-4A series power lightning arrester </title>
           <link>http://www.91way.com/info_en/4566.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:40:08</pubDate>
           <comments></comments>
           <description>DB-4A series power lightning arrester&lt;BR&gt;&lt;BR&gt;Product use: DB-4A series power lightning arrester is used in LPZ1 and LPZ2 strong lightning protection zones to protect against overvoltage caused by lightning strikes in 220/380V three-phase distribution systems.&lt;BR&gt;Industries of use: Aerospace industry, aviation ports, aviation flight, military combat command centers, telecommunications and telephone systems, RF equipment, satellite/microwave communication systems, wireless television stations and networks, computer systems, banking, investment and securities industry, medical equipment, printing machinery, boiler manufacturers, and all electrical equipment.&lt;BR&gt;Product features: Adopting a four way protection mode of three-phase phase line to neutral line and neutral line to ground line;&lt;BR&gt;Using specially designed high-energy MOV circuit breakers, with a 1mA voltage sensitivity of 620V, it can be safely used in 220V/380V AC power supply systems.&lt;BR&gt;The use of high-energy MOV gate diversion technology (national patented technology) ensures that each gate uniformly bears the lightning current, so that the protective current of each phase can withstand a strong 140KA lightning current after diversion.&lt;BR&gt;Automatic disconnection device: When any protective gate exceeds its allowable lightning current and is damaged, the circuit will automatically disconnect from the entire power supply circuit to ensure normal power supply.&lt;BR&gt;Failure indication;&lt;BR&gt;&lt;BR&gt;Automatic lightning strike counting;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD&gt;project&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Technical performance)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Working Voltage&lt;/TD&gt;
&lt;TD&gt;220/380V AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Surge starting voltage&lt;/TD&gt;
&lt;TD&gt;600V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s rated flow rate&lt;/TD&gt;
&lt;TD&gt;70KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s maximum flow rate&lt;/TD&gt;
&lt;TD&gt;140KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;10/350 ¦Ì s maximum flow rate&lt;/TD&gt;
&lt;TD&gt;30KA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;10/350 ¦Ì s30KA residual voltage&lt;/TD&gt;
&lt;TD&gt;¡´1.2KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s 70KA residual voltage&lt;/TD&gt;
&lt;TD&gt;¡´2.2KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Wiring resistance&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;The grounding resistance should be less than 10 ¦¸, and the grounding wire should use a wire with a diameter of ¡Ý 16mm&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;wiring method&lt;/TD&gt;
&lt;TD&gt;The connecting wire should use a wire with a diameter of ¡Ý 10mm &amp;sup2;.&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Installation method&lt;/TD&gt;
&lt;TD&gt;Fixed installation&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200811/200811381939425.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 227px; WIDTH: 421px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Schematic diagram of DB-4A series power lightning arrester&quot; src=&quot;/uploadfiles/200811/200811381939425.gif&quot; width=421 height=227&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;DB-4A series power lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DB-3A series power lightning arrester </title>
           <link>http://www.91way.com/info_en/4565.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:59</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product use: DB-3A series power lightning arrester is suitable for protection against overvoltage caused by lightning strikes in LPZ1 and LPZ2 strong lightning protection zones, 220/380V three-phase distribution systems. &amp;nbsp;&amp;nbsp;&lt;BR&gt;Industries of use: telecommunications industry, broadcasting industry, petrochemical industry, transportation and highway industry, financial industry, and government agencies at all levels.&lt;BR&gt;Product features: large flow capacity;&lt;BR&gt;Full mode protection design: L-N, L-PE, N-PE seven channel protection mode;&lt;BR&gt;Adopting multi piece parallel current sharing technology;&lt;BR&gt;Remote signaling output: provides two sets of normally open and normally closed relay contact signals;&lt;BR&gt;Fault automatic disconnection: Each pressure-sensitive component is equipped with overload protection, which can automatically disconnect from the circuit when it is damaged;&lt;BR&gt;Deterioration indication, damage sound and light alarm;&lt;BR&gt;Automatic lightning strike counting;&lt;BR&gt;Kevin wiring: eliminate the voltage drop of the wiring inductance;&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;project&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Technical performance&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Working Voltage&lt;/TD&gt;
&lt;TD&gt;220/380V¡¡AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Voltage sensitive (1mA)&lt;/TD&gt;
&lt;TD&gt;620V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;8/20 ¦Ì s nominal discharge current&lt;/TD&gt;
&lt;TD&gt;40kA¡¢60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;8/20 ¦Ì s maximum discharge current&lt;/TD&gt;
&lt;TD&gt;100kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Residual voltage (8/20 ¦Ì s3 kA)&lt;/TD&gt;
&lt;TD&gt;0.9kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;protected mode&lt;/TD&gt;
&lt;TD&gt;L-N¡¢L-PE¡¢N-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;wiring method&lt;/TD&gt;
&lt;TD&gt;Terminal connection (4-25mm2)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Installation method&lt;/TD&gt;
&lt;TD&gt;Fixed installation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;working environment&lt;/TD&gt;
&lt;TD&gt;Temperature -40 ¡æ~+80 ¡æ, relative humidity ¡Ü 95%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;Dimensions (length x width x height)&lt;/TD&gt;
&lt;TD&gt;245mm&#215;130mm&#215;110mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=19&gt;weight&lt;/TD&gt;
&lt;TD&gt;2.2©K&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;/P&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD height=28 width=&quot;12%&quot;&gt;model&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;Power supply capacity&lt;BR&gt;£¨KVA£©&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;Nominal discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;/TD&gt;
&lt;TD width=&quot;27%&quot;&gt;Maximum discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;22%&quot;&gt;Overall dimensions&lt;BR&gt;Height x Width x Depth&lt;/TD&gt;
&lt;TD width=&quot;9%&quot;&gt;weight&lt;BR&gt;£¨KG£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;DB-3A&lt;BR&gt;(Three phase)&lt;/TD&gt;
&lt;TD&gt;No requirements&lt;/TD&gt;
&lt;TD height=19&gt;forty&lt;/TD&gt;
&lt;TD height=19&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;110&#215;130&#215;245&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;DB-3A&lt;BR&gt;(Three phase)&lt;/TD&gt;
&lt;TD&gt;No requirements&lt;/TD&gt;
&lt;TD height=19&gt;sixty&lt;/TD&gt;
&lt;TD&gt;100KA(8/20¦Ìs)&lt;BR&gt;Or 15KA (10/350 ¦Ì s)&lt;/TD&gt;
&lt;TD&gt;110&#215;130&#215;245&lt;/TD&gt;
&lt;TD&gt;two&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;&lt;A href=&quot;/uploadfiles/200811/20081138176315.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 249px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DB-3A series power lightning arrester wiring diagram&quot; src=&quot;/uploadfiles/200811/20081138176315.gif&quot; width=400 height=249&gt;&lt;/A&gt;&lt;BR&gt;DB-3A series power lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DDB-3J type pager lightning arrester </title>
           <link>http://www.91way.com/info_en/4564.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:50</pubDate>
           <comments></comments>
           <description>The DDB-3J type pager lightning arrester can provide lightning protection and overvoltage protection for communication equipment, prevent high-frequency electromagnetic wave interference, and has the ability to improve equipment electromagnetic compatibility.&lt;BR&gt;&lt;BR&gt;Industry of use: Small base station equipment in the communication industry (telecommunications pager base station);&lt;BR&gt;Lightning protection for base station transmitter equipment and broadcasting room equipment in the broadcasting and television industry;&lt;BR&gt;Lightning protection for petrochemical field equipment;&lt;BR&gt;Lightning protection for power supply of financial institutions and various government equipment&lt;BR&gt;&lt;BR&gt;Product features: sensitive response, high 1mA voltage sensitive (600V)&lt;BR&gt;Residual voltage at the power output terminal (¡Ü 600V);&lt;BR&gt;Fast response time and strong protection capability&lt;BR&gt;L-N, L-PE, N-PE protection mode design.&lt;BR&gt;&lt;BR&gt;The design of the DDB-3J type pager lightning arrester adopts a new concept of lightning protection, with the aim of protecting electrical equipment from lightning strikes, and particularly strengthening the protection of both ends of the phase and neutral lines. A discharge circuit consisting of eight sets of zinc oxide varistors and discharge tubes is formed with L-PE protection, a discharge circuit consisting of discharge tubes is formed with N-PE protection, and a voltage limiting and discharge circuit consisting of eight sets of zinc oxide varistors, iron core inductors, and capacitors is formed with L-N protection.&lt;BR&gt;The DDB-3J type pager lightning protection overvoltage protection box has the characteristics of high 1mA pressure-sensitive voltage (600V), low residual voltage at the power output terminal (¡Ü 600V), fast response time, and strong protection capability. It is installed at the front end of the electrical equipment to ensure the normal operation of any electronic device under 8/20 ¦Ì s lightning waveform and 40kA simulated lightning impulse.&lt;BR&gt;The DDB-3J type pager lightning protection overvoltage protection box is specially designed for pager base stations, with a power equipment capacity limit of 800 VA. Its technical performance indicators are shown in the attached table. If users have special requirements, our company can also produce according to their needs. This product has reliable quality, superior performance, low price, and easy installation and use. Simply connect the wires as shown in the diagram to use it. This product has been used by communication departments in various provinces and cities, with good feedback. Welcome to choose.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD&gt;model&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;DDB-3J (single-phase)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Allowable working voltage&lt;/TD&gt;
&lt;TD&gt;AC 220V&#177;35%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Lightning arrester model&lt;/TD&gt;
&lt;TD&gt;20621 and R500W05&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s rated current (KA)&lt;/TD&gt;
&lt;TD&gt;forty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s maximum flow rate (KA)&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Residual voltage between phase and neutral lines under rated flow rate of 8/20 ¦Ì s&lt;/TD&gt;
&lt;TD&gt;&amp;lt; 600V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Voltage drop under rated load&lt;/TD&gt;
&lt;TD&gt;&amp;lt; 4V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;The ability to suppress high-frequency electromagnetic waves&lt;/TD&gt;
&lt;TD&gt;The cut-off frequency of the low-pass filter inside the box is ¡Ü 2000 Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;insulation resistance&lt;/TD&gt;
&lt;TD&gt;£¾2M¦¸&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;pressure rating&lt;/TD&gt;
&lt;TD&gt;AC 1500V£» 1min&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;equipment capacity&lt;/TD&gt;
&lt;TD&gt;800VA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Overall dimensions&lt;/TD&gt;
&lt;TD&gt;155&#215;115&#215;90&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200811/200811381350365.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 227px; WIDTH: 421px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Electrical schematic diagram of DDB-3J type pager lightning arrester&quot; src=&quot;/uploadfiles/200811/200811381350365.gif&quot; width=421 height=227&gt;&lt;/A&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DDB-2J type power lightning arrester </title>
           <link>http://www.91way.com/info_en/4563.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:42</pubDate>
           <comments></comments>
           <description>Product Usage&lt;BR&gt;The DDB-2J power lightning arrester is suitable for use in 220/380V single-phase AC power grids with a power supply capacity of less than 10kVA, for lightning protection against overvoltage, electromagnetic interference, and high-order harmonics. Especially in areas where lightning protection zoning is difficult and it is not easy to implement multi-level protection for precision equipment.&lt;BR&gt;Industries of use: telecommunications industry, broadcasting industry, petrochemical industry, transportation and highway industry, financial industry, and government agencies at all levels.&lt;BR&gt;Product features: Large flow capacity (8/20 ¦Ì S 100kA);&lt;BR&gt;Residual voltage (&amp;lt;600V);&lt;BR&gt;Prevent high-frequency electromagnetic waves and electromagnetic interference;&lt;BR&gt;Improve power factor and enhance the load capacity of the power grid;&lt;BR&gt;Full mode protection design;&lt;BR&gt;Multi channel interception and current sharing technology;&lt;BR&gt;Automatic fault detachment (lightning protection unit);&lt;BR&gt;Lightning strike count.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;project&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Technical performance&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Working Voltage&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;220V¡¡AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=18 colSpan=2&gt;Rated power supply capacity&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;10kVA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Voltage sensitive (1mA)&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;620V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s nominal discharge current&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;40kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s maximum discharge current&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;100kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=39 rowSpan=2 width=&quot;29%&quot;&gt;Residual voltage 60kA (8/20 ¦Ì s)&lt;/TD&gt;
&lt;TD height=20 width=&quot;16%&quot;&gt;L-N&lt;/TD&gt;
&lt;TD height=20 width=&quot;55%&quot;&gt;&amp;lt; 600V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;16%&quot;&gt;L-PE&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;&amp;lt; 1400V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;line entry and exit method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Incoming and outgoing lines&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;wiring method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Terminal connection (6-25 mm2)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Installation method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Fixed installation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;working environment&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Temperature -40 ¡æ~+80 ¡æ, relative humidity ¡Ü 95%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Dimensions (length x width x height)&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;195mm&#215;360mm&#215;115mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;weight&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;8.1©K&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;13%&quot;&gt;model&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;Power supply capacity&lt;BR&gt;£¨KVA£©&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;Nominal discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;Maximum discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;Overall dimensions&lt;BR&gt;Height x Width x Depth&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;weight&lt;BR&gt;£¨KG£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2&gt;DDB-2J&lt;BR&gt;(Single phase)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;five&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2&gt;DDB-2J&lt;BR&gt;(Single phase)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;ten&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200811/200811381050795.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 152px; WIDTH: 400px; FILTER: none&quot; border=0 hspace=0 alt=&quot;DDB-2J type power lightning arrester wiring diagram&quot; src=&quot;/uploadfiles/200811/200811381050795.gif&quot; width=400 height=152&gt;&lt;/A&gt;&lt;BR&gt;DDB-2J type power lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DB-2C type power lightning arrester </title>
           <link>http://www.91way.com/info_en/4562.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:32</pubDate>
           <comments></comments>
           <description>Product use: DB-2C power lightning arrester is suitable for 220/380V, power supply capacity less than 1000kVA three-phase AC power grid, to prevent lightning overvoltage, electromagnetic interference, and high-order harmonics. Especially in areas where lightning protection zoning is difficult and it is not easy to implement multi-level protection for precision equipment. &amp;nbsp;&lt;BR&gt;Industries of use: telecommunications industry, broadcasting industry, petrochemical industry, transportation and highway industry, financial industry, and government agencies at all levels.&lt;BR&gt;Product features: Large flow capacity (8/20 ¦Ì S 100kA);&lt;BR&gt;Residual voltage (&amp;lt;600V);&lt;BR&gt;Prevent high-frequency electromagnetic waves and electromagnetic interference; &amp;nbsp;&lt;BR&gt;Improve power factor and enhance the load capacity of the power grid; &amp;nbsp;&lt;BR&gt;Seven mode protection design; &amp;nbsp;&lt;BR&gt;Multi channel interception and current sharing technology; &amp;nbsp;&lt;BR&gt;Automatic fault disengagement (lightning protection module); &amp;nbsp;&lt;BR&gt;Deterioration indication, damage sound and light alarm; &lt;BR&gt;Clock and calendar display;&lt;BR&gt;Power grid voltage monitoring;&lt;BR&gt;Record of lightning strike time and frequency;&lt;BR&gt;RS485 or RS232 communication interface.&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;project&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Technical performance&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Working Voltage&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;220/380V¡¡AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Rated power supply capacity&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;50¡«1000kVA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Voltage sensitive (1mA)&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;620V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s nominal discharge current&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s maximum discharge current&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;100kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 width=&quot;31%&quot;&gt;Residual voltage 60kA (8/20 ¦Ì s)&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;L-N&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;&amp;lt; 600V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;14%&quot;&gt;N-PE&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;&amp;lt; 1400V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Lightning strike count&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;LCD counter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;caution function &lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Deterioration indication, sound and light alarm, remote signaling output&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;line entry and exit method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Bottom inlet and outlet (below 100kVA) or top inlet and top outlet (above 100kVA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;wiring method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Terminal post (below 100kVA) or busbar (above 100kVA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Installation method&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Wall mounted (below 100kVA) or vertical (above 100kVA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;working environment&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;Temperature -40 ¡æ~+80 ¡æ, relative humidity ¡Ü 95%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD height=21 colSpan=2&gt;Dimensions (length x width x height)&lt;/TD&gt;
&lt;TD height=21 width=&quot;55%&quot; align=center&gt;500mm &#215; 320mm &#215; 750mm (below 100kVA) 800mm &#215; 800mm &#215; 2000mm (above 100kVA)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;weight&lt;/TD&gt;
&lt;TD width=&quot;55%&quot;&gt;43kg (below 100kVA)&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;13%&quot;&gt;model&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;12%&quot;&gt;Power supply capacity&lt;BR&gt;£¨KVA£©&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;Nominal discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;/TD&gt;
&lt;TD width=&quot;20%&quot;&gt;Maximum discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;Overall dimensions&lt;BR&gt;Height x Width x Depth&lt;/TD&gt;
&lt;TD width=&quot;13%&quot;&gt;weight&lt;BR&gt;£¨KG£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2&gt;DDB-2J&lt;BR&gt;(Single phase)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;five&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2&gt;DDB-2J&lt;BR&gt;(Single phase)&lt;/TD&gt;
&lt;TD rowSpan=2&gt;ten&lt;/TD&gt;
&lt;TD&gt;twenty&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;forty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;115&#215;360&#215;195&lt;/TD&gt;
&lt;TD&gt;eight&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/uploadfiles/200811/2008112181341706.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 288px; WIDTH: 465px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Electrical schematic diagram of DB-2C power lightning arrester&quot; src=&quot;/uploadfiles/200811/2008112181341706.gif&quot; width=465 height=288&gt;&lt;/A&gt;&lt;BR&gt;DB-2C power lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DB-1A,DDB1A type power lightning arrester (lightning arrester) </title>
           <link>http://www.91way.com/info_en/4561.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:23</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product use: This product is suitable for protection against overvoltage caused by induction, operation, and other reasons in LPZ1 and LPZ2 lightning protection zones, 220/380V single-phase and three-phase distribution systems. &amp;nbsp;&amp;nbsp;&lt;BR&gt;Industries of use: telecommunications industry, broadcasting industry, petrochemical industry, transportation and highway industry, financial industry, and government agencies at all levels.&lt;BR&gt;Product features: large flow capacity;&lt;BR&gt;Residual voltage (&amp;lt;1.2kV);&lt;BR&gt;Design of L-N and N-PE protection modes;&lt;BR&gt;Current equalization technology; &amp;nbsp;&lt;BR&gt;Automatic fault disengagement (lightning protection unit).&lt;/P&gt;
&lt;P&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD&gt;project&lt;/TD&gt;
&lt;TD&gt;Technical performance&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Working Voltage&lt;/TD&gt;
&lt;TD&gt;220/380V¡¡AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Voltage sensitive (1mA)&lt;/TD&gt;
&lt;TD&gt;620V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s nominal discharge current&lt;/TD&gt;
&lt;TD&gt;20kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;8/20 ¦Ì s maximum discharge current&lt;/TD&gt;
&lt;TD&gt;60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Residual pressure (8/20 ¦Ì s)&lt;/TD&gt;
&lt;TD&gt;£¼0.9kV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;protected mode&lt;/TD&gt;
&lt;TD&gt;L-N¡¢N-PE&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;wiring method&lt;/TD&gt;
&lt;TD&gt;Terminal connection (2.5-10mm2)&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Installation method&lt;/TD&gt;
&lt;TD&gt;Fixed installation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;working environment&lt;/TD&gt;
&lt;TD&gt;Temperature -40 ¡æ~+80 ¡æ, relative humidity ¡Ü 95%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;Dimensions (length x width x height)&lt;/TD&gt;
&lt;TD&gt;90mm&#215;150mm&#215;70mm&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;&lt;SPAN&gt;JD-DB-1 Jingda Thunder God Defense:&lt;BR&gt;&lt;/SPAN&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 600px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=600 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;model&lt;/TD&gt;
&lt;TD width=&quot;28%&quot;&gt;circulation&lt;BR&gt;KA&lt;/TD&gt;
&lt;TD width=&quot;33%&quot;&gt;Dimensions (mm)&lt;BR&gt;Width x Thickness x Height&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 colSpan=2&gt;DB-1 Type A&lt;/TD&gt;
&lt;TD&gt;20/60&lt;/TD&gt;
&lt;TD&gt;172&#215;127&#215;80&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;40/100&lt;/TD&gt;
&lt;TD&gt;210&#215;178&#215;80&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 colSpan=2&gt;DB-1 B (Excellent) type&lt;/TD&gt;
&lt;TD&gt;20/60&lt;/TD&gt;
&lt;TD&gt;360&#215;250&#215;500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;40/100&lt;/TD&gt;
&lt;TD&gt;360&#215;250&#215;500&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 colSpan=2&gt;DB-1 C-type 50KVA&lt;/TD&gt;
&lt;TD&gt;20/60&lt;/TD&gt;
&lt;TD&gt;500&#215;300&#215;700&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;40/100&lt;/TD&gt;
&lt;TD&gt;500&#215;300&#215;700&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 width=&quot;22%&quot;&gt;DB-J3KVA&lt;BR&gt;The following access networks are used&lt;/TD&gt;
&lt;TD height=13 width=&quot;17%&quot;&gt;DDB-J1 single-phase&lt;/TD&gt;
&lt;TD&gt;20/60&lt;/TD&gt;
&lt;TD&gt;215&#215;130&#215;80&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;DDB-J2 single-phase&lt;/TD&gt;
&lt;TD&gt;40/100&lt;/TD&gt;
&lt;TD&gt;215&#215;130&#215;80&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;P align=center&gt;&lt;BR&gt;DB-1A, DDB1A type power lightning arrester (lightning arrester)&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]DB-2B type power lightning arrester </title>
           <link>http://www.91way.com/info_en/4560.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:15</pubDate>
           <comments></comments>
           <description>&lt;P&gt;Product Usage: This product is suitable for use in 220/380V, 30-50kVA three-phase AC power grids, to prevent lightning overvoltage, electromagnetic interference, and high-order harmonics. Especially in areas where lightning protection zoning is difficult and it is not easy to implement multi-level protection for precision equipment.&lt;BR&gt;Industries of use: telecommunications industry, broadcasting industry, petrochemical industry, transportation and highway industry, financial industry, and government agencies at all levels.&lt;BR&gt;Product features: Large flow capacity (8/20 ¦Ì S 100kA);&lt;BR&gt;Residual voltage (&amp;lt;600V);&lt;BR&gt;Prevent high-frequency electromagnetic waves and electromagnetic interference;&lt;BR&gt;Improve power factor and enhance the load capacity of the power grid;&lt;BR&gt;Seven mode protection design;&lt;BR&gt;Multi channel interception and current sharing technology;&lt;BR&gt;Automatic fault disengagement (lightning protection module);&lt;BR&gt;Damage indication alarm;&lt;BR&gt;Lightning strike count.&lt;/P&gt;
&lt;P align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;project&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;Technical performance&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Working Voltage&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;220/380V¡¡AC50Hz&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Rated power supply capacity&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;30¡«50kVA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Voltage sensitive (1mA)&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;620V&#177;10%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s nominal discharge current&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;60kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;8/20 ¦Ì s maximum discharge current&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;100kA&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=2 width=&quot;35%&quot;&gt;60kA (8/20 ¦Ì s) limited voltage&lt;/TD&gt;
&lt;TD width=&quot;16%&quot;&gt;L-N&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;&amp;lt; 600V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD width=&quot;16%&quot;&gt;N-PE&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;&amp;lt; 1400V&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Lightning strike count&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;LCD counter&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;line entry and exit method&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;Incoming and outgoing lines&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;wiring method&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;Terminal wiring&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Installation method&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;wall-mounted installation&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;working environment&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;Temperature -40 ¡æ~+80 ¡æ, relative humidity ¡Ü 95%&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;Dimensions (length x width x height)&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;370mm&#215;250mm&#215;520mm&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD colSpan=2&gt;weight&lt;/TD&gt;
&lt;TD width=&quot;49%&quot;&gt;27kg&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/P&gt;
&lt;DIV align=center&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=2 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD height=28 width=&quot;12%&quot;&gt;model&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;11%&quot;&gt;Power supply capacity&lt;BR&gt;£¨KVA£©&lt;/TD&gt;
&lt;TD width=&quot;19%&quot;&gt;Nominal discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;/TD&gt;
&lt;TD width=&quot;23%&quot;&gt;Maximum discharge current&lt;BR&gt;£¨KA 8/20¦Ìs£©&lt;BR&gt;&lt;/TD&gt;
&lt;TD width=&quot;21%&quot;&gt;Overall dimensions&lt;BR&gt;Height x Width x Depth&lt;/TD&gt;
&lt;TD width=&quot;14%&quot;&gt;weight&lt;BR&gt;£¨KG£©&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;DDB-2B&lt;BR&gt;(Three phase)&lt;/TD&gt;
&lt;TD&gt;fifty&lt;/TD&gt;
&lt;TD&gt;sixty&lt;/TD&gt;
&lt;TD&gt;one hundred&lt;/TD&gt;
&lt;TD&gt;520&#215;250&#215;370&lt;/TD&gt;
&lt;TD&gt;twenty-seven&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;/DIV&gt;
&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200811/200811218729987.gif&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 278px; WIDTH: 470px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Electrical schematic diagram of DB-2B power lightning arrester&quot; src=&quot;/uploadfiles/200811/200811218729987.gif&quot; width=470 height=278&gt;&lt;/A&gt;&lt;BR&gt;DB-2B type power lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]K plug-in surge arrester </title>
           <link>http://www.91way.com/info_en/3575.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:39:06</pubDate>
           <comments></comments>
           <description>The K-type plug-in surge arrester is designed as a module, easy to install, and easy to operate for live maintenance&lt;BR&gt;Built in overcurrent and overheat, temperature controlled circuit breaker technology&lt;BR&gt;High quality zinc oxide varistors with independent intellectual property rights&lt;BR&gt;Low leakage current, fast response time, and low residual voltage&lt;BR&gt;Can be equipped with remote signaling interface and sound and light alarm, enabling remote monitoring&lt;BR&gt;Alarm indication: green (normal), red (fault)&lt;BR&gt;&lt;BR&gt;Technical parameters of K-type plug-in surge arrester:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE class=t style=&quot;WIDTH: 680px; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=680 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=&quot;31%&quot;&gt;model&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-D5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-D10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-C15&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-C20&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-B25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;TNR-B30&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Rated working voltage Un (V~)&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;two hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;220/380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;220/380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;220/380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;220/380&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;220/380&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Continuous operating voltage Uc (V~)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;two hundred and seventy-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;275/320&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;385/420&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;275/320&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;385/420&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;three hundred and eighty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;four hundred and twenty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Protection level Up (kV~)&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.7&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;¡Ü1.0&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.9&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;¡Ü1.2/1.4&lt;/TD&gt;
&lt;TD&gt;¡Ü1.0/1.4&lt;/TD&gt;
&lt;TD&gt;¡Ü1.5/1.6&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü1.2/1.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;¡Ü1.7/1.8&lt;/TD&gt;
&lt;TD&gt;¡Ü1.8&lt;/TD&gt;
&lt;TD&gt;¡Ü1.9&lt;/TD&gt;
&lt;TD&gt;¡Ü1.9&lt;/TD&gt;
&lt;TD&gt;¡Ü2.0&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Nominal discharge current (8/20 ¦Ì S) In (kA)&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;fifteen&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Maximum current capacity Imax (8/20 ¦Ì S) In (kA)&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;twenty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;thirty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;forty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;sixty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Response time t (nS)&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;DIV align=center&gt;£¼25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;working environment&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;DIV align=center&gt;-40 ~ +85&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;relative humidity&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;DIV align=center&gt;¡Ü95%(25¡æ)&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=left&gt;Connecting wire cross-sectional area (mm2)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý10&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý16&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý16&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý16&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Grounding wire cross-sectional area (mm2)&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý16&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD colSpan=2&gt;
&lt;DIV align=center&gt;¡Ý25&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;Alarm line cross-sectional area (mm2)&lt;/TD&gt;
&lt;TD colSpan=12&gt;
&lt;DIV align=center&gt;¡Ý 1.0&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;&lt;BR&gt;Product wiring:&lt;BR&gt;This product can be used for single and three-phase surge protection under different power supply systems through different combinations, especially for the 3+1 protection (three-phase+N-PE) commonly used in TT systems in small and medium-sized cities in China.&lt;BR&gt;&lt;BR&gt;External dimensions, installation track dimensions:&lt;BR&gt;The lightning arrester is installed using 35mm track profiles, and the external dimensions are shown in the figure&lt;BR&gt;&lt;BR&gt;Application:&lt;BR&gt;This product can be used for protection levels B, C, and D, and is suitable for lightning protection zones LPZ1-LPZ2 and LPZ3. TNR-D5 and TNR-D10 have a protection level of D, meeting the end protection requirements for electrical equipment. TNR-C15 and TNR-C20 have a protection level of C and are commonly used for lightning surge protection in building power supply systems, floor or indoor distribution boxes, and low-voltage switchgear cabinets. TNR-B25 and TNR-B30 have a protection level of B and are generally installed in the low-voltage main switchgear of building incoming lines.&lt;BR&gt;&lt;BR&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]XFD-T coaxial signal lightning arrester </title>
           <link>http://www.91way.com/info_en/3574.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:38:57</pubDate>
           <comments></comments>
           <description>XFD-T coaxial signal lightning arrester&lt;BR&gt;&lt;BR&gt;Application scope:&lt;BR&gt;Protection of computer networks, video signals, monitoring signals, and communication signals&lt;BR&gt;&lt;BR&gt;The main features of XFD-T coaxial signal lightning arrester are:&lt;BR&gt;Large flow capacity&lt;BR&gt;Frequency bandwidth&lt;BR&gt;The core components adopt internationally renowned brands with excellent performance&lt;BR&gt;Low insertion loss&lt;BR&gt;The standing wave ratio is small&lt;BR&gt;Reliable work&lt;BR&gt;Simple structure, easy to install and maintain&lt;BR&gt;&lt;BR&gt;Technical parameters of XFD-T coaxial signal lightning arrester:&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 100%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=1 width=&quot;100%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Working voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Nominal discharge current&lt;BR&gt;In(8/20¦ÌS)kA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Limit voltage V&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;Transmission rate Mbps&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Insertion loss dB&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;response time&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;connection form&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;TNR-T/BNC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;K/K&lt;BR&gt;K/J&lt;BR&gt;J/J&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;TNR-T/TNC&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;K/K&lt;BR&gt;K/J&lt;BR&gt;J/J&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;TNR-T/N&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;K/K&lt;BR&gt;K/J&lt;BR&gt;J/J&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;TNR-T/SMA&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;K/K&lt;BR&gt;K/J&lt;BR&gt;J/J&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;TNR-K/CC4&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü40&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;ten&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;¡Ü0.5&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;1nS&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;K/K&lt;BR&gt;K/J&lt;BR&gt;J/J&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;XFD-T coaxial signal lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]HY1.5W-0.28~0.8kV series zinc oxide lightning arrester </title>
           <link>http://www.91way.com/info_en/3122.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:38:48</pubDate>
           <comments></comments>
           <description>HY1.5W-0.28-0.8kV series zinc oxide lightning arrester&lt;BR&gt;&lt;BR&gt;
&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Place of use&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=228 colSpan=3&gt;
&lt;DIV align=center&gt;Low voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Product model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;HY1.5W-0.28/1.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV&gt;HY1.5W-0.5/2.6&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV&gt;HY1.5W-0.8/3.9&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of rated voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of nominal voltage of the system (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point three eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point six six&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Effective value of continuous operating voltage (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point two four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;zero point four two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point seven two&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;DC (U1mA) reference voltage not less than (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;zero point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;one point two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;one point eight&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD rowSpan=3 width=103&gt;
&lt;DIV align=center&gt;Maximum residual voltage peak value (kV)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under steep wave impulse current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under lightning impulse current&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;one point three&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;two point six&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;three point nine&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=108&gt;
&lt;DIV align=center&gt;Under the impact current of operation&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;-&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;2000 ¦Ì s square wave current capacity (A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;4/10 ¦Ì s peak impulse current (kA)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR&gt;
&lt;TD width=211 colSpan=2&gt;
&lt;DIV&gt;Maximum leakage current under 0.75 DC reference voltage (¦Ì A)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=84&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD width=72&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;A href=&quot;http://www.91way.com/upload2015/201501/20150117200923608.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 262px; WIDTH: 680px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Installation dimensions of HY1.5W-0.28~0.8kV series zinc oxide lightning arrester&quot; src=&quot;/upload2015/201501/20150117200923608.jpg&quot; width=680 height=262&gt;&lt;/A&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]Y3W,HY3W series low-voltage metal oxide lightning arrester </title>
           <link>http://www.91way.com/info_en/3046.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:38:39</pubDate>
           <comments></comments>
           <description>&lt;P align=center&gt;&lt;A href=&quot;/uploadfiles/200804/2008429222130409.jpg&quot; target=_blank&gt;&lt;IMG style=&quot;HEIGHT: 547px; WIDTH: 560px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Dimensions of Y3W and HY3W series low-voltage metal oxide lightning arresters&quot; src=&quot;/uploadfiles/200804/2008429222130409.jpg&quot; width=560 height=547&gt;&lt;/A&gt;&lt;BR&gt;&lt;BR&gt;Y3W, HY3W series low-voltage metal oxide lightning arrester&lt;BR&gt;&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]HY3WL1-0.8KV Composite jacket zinc oxide DC lightning arrester </title>
           <link>http://www.91way.com/info_en/2875.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:38:31</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 650px; BORDER-COLLAPSE: collapse&quot; cellSpacing=0 cellPadding=0 width=650 align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center width=&quot;None&quot;&gt;
&lt;TD width=132&gt;Lightning arrester model&lt;/TD&gt;
&lt;TD width=89&gt;Rated voltage of lightning arrester (kV)&lt;/TD&gt;
&lt;TD width=66&gt;System nominal voltage kV&lt;/TD&gt;
&lt;TD width=75&gt;Direct discharge voltage KV&lt;/TD&gt;
&lt;TD width=69&gt;Impulse discharge voltage KV&lt;/TD&gt;
&lt;TD width=89&gt;8/20WS impact residual voltage not exceeding KV&lt;/TD&gt;
&lt;TD width=76&gt;Leakage current not exceeding KV&lt;/TD&gt;
&lt;TD width=78&gt;Rectified voltage KV&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD&gt;HY3WL1-0.8/2.15&lt;/TD&gt;
&lt;TD&gt;zero point eight&lt;/TD&gt;
&lt;TD&gt;zero point six&lt;/TD&gt;
&lt;TD&gt;1.3-1.7&lt;/TD&gt;
&lt;TD&gt;two point one five&lt;/TD&gt;
&lt;TD&gt;two point one five&lt;/TD&gt;
&lt;TD&gt;fifteen&lt;/TD&gt;
&lt;TD&gt;one&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;HY3WL1-0.8KV composite jacket zinc oxide DC lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>
       <item>
           <title>[Low-voltage arrester]Y1.5W-0.28/1.3 type low-voltage lightning arrester </title>
           <link>http://www.91way.com/info_en/71.html</link>
           <author></author>
           <guid></guid>
           <category>Low-voltage arrester</category>
           <pubDate>2026-6-16 19:38:22</pubDate>
           <comments></comments>
           <description>&lt;TABLE style=&quot;WIDTH: 98%; BORDER-COLLAPSE: collapse&quot; cellSpacing=1 cellPadding=3 width=&quot;98%&quot; align=center border=1&gt;
&lt;TBODY&gt;
&lt;TR align=center&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Places where lightning arresters are used&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Lightning arrester model&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Rated voltage of lightning arrester kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;System nominal voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Continuous operating voltage kV (effective value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;DC (U1mA) reference voltage kV not less than&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;&lt;/DIV&gt;
&lt;DIV align=center&gt;Residual voltage under lightning impulse current KV (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;2000 ¦Ô s square wave current A (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;4/10 ¦Ô s impulse current kA (peak value)&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD&gt;
&lt;DIV align=center&gt;Maximum leakage current ¦Ô A at 0.75 DC reference voltage&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;
&lt;TR align=center&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;low pressure&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;Y1.5W-0.28/1.3&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point two eight&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point two two&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point two four&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;zero point six zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD align=center&gt;
&lt;DIV align=center&gt;one point three zero&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;twenty-five&lt;/DIV&gt;&lt;/TD&gt;
&lt;TD rowSpan=3&gt;
&lt;DIV align=center&gt;fifty&lt;/DIV&gt;&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;
&lt;P align=center&gt;&lt;BR&gt;Y1.5W-0.28¡«0.66kV&lt;BR&gt;&lt;BR&gt;&lt;IMG style=&quot;HEIGHT: 281px; WIDTH: 225px; FILTER: none&quot; border=0 hspace=0 alt=&quot;Y1.5W-0.28-0.66kV series low-voltage lightning arrester external dimensions&quot; src=&quot;/uploadfiles/200610/20061018123753734.gif&quot; width=225 height=281&gt;&lt;BR&gt;&lt;BR&gt;Y1.5W-0.28-0.66kV series low-voltage lightning arrester&lt;BR&gt;&lt;/P&gt;</description>
       </item>